Document n9r4y66QdrBJgrmdggrZjz0Ba
Part A Response
Part A - to be submitted within 24 hours of the incident
Permit Number Name Of Operator Location Of Installation Time and date of the detection
BU5453IY AGC Chemicals Europe Ltd Hillhouse International, Thornton Cleveleys, Lancashire 01/04/2023 08:00 - 10:00
(a) Notification requirements for any malfunction, breakdown or failure of equipment or
techniques, accident or fugitive emission of a substance not controlled by an emission limit which
has caused, is causing or may cause significant pollution
To be notified within 24 hours of detection
Date and time of event
01/04/2023 08:00 - 10:00
Reference or description of the location of the event
Process gas release from Steam Pyrolysis 2 (SP2).
Description of where any release into the environment took place
Air emission, process gas release from SP2.
Substance(s) potentially released
Best estimate of the quantity or rate of release of substance(s)
Process gas containing: Tetrafluoroethylene (TFE) Chlorodifluoromethane (R22) Hexafluoropropylene (HFP) Trifluoroethylene (3FE) Difluoromethane (R32) Vinylidene fluoride (VDF) Initial estimate based on information available at the time of the release:
Substances released TFE R22 HFP
Difluoromethane
3FE VDF
kg 193.39 61.29 33.23
0.08 0.18 0.00
AGCCE will provide context of release in terms of permit limits and emissions from w/c 27/03/2023 within the Part B submission.
Measures taken, or intended to be taken, to stop any emission
To be reviewed following abnormal event investigation. Potential cause due to lowering of the level in SP2 cooling or caustic tower allowing gas to flow through the SP lute and into the waste acid tank.