Document n9qbGm5GbqgDJXQ98KaE2a9p6
Air System Equipment Fans and Blowers
Hartzell Propeller Fan Go.
DIV. OF CASTLE HILLS CORP.
Piqua, Ohio
Engineering Offices In Principal Cities
PROPELLER TYPE FANS Standard fans (shown) in single-propeller, two-propeller and multi-blade models, diameters from 12 in. to 60 in. Also LoNoise Fans, 24 in. to 60 in., and a special high pressure fan which operates efficiently against pressures as high as 3_jn. water gauge. All can be supplied in direct-drive, belt-drive, pulleydrive or extension shaft construction--ring or panel mounted. Cast aluminum-alloy propellers.
I
i i
I
VANEAXIAL BLOWERS
For use in duct systems, against very heavy pressures. Directdrive in six sizes, 18 in. to 42 in. Belt-drive in 10 sizes, 12 in to 54 in. Air deliveries to 88,000 cfm. Special high-temperature models move air at elevated temperatures; and air containing mild acids and alkalies, without danger of premature failure of belts and bearings. All-welded construction. Dynamicallybalanced cast aluminum alloy impellers.
I
;.s>
DUCT FANS
Standard duct fans are prefabricated duct sections which can easily and quickly be bolted into place in any duct system. Direct or belt-drive, 12 in. to 60 in. Bi-Pass Duct Fan has motor in tunnel out of air stream; for high temperature applications (up to 550 F with special heavy duty construction) and for moving corrosive fumes.
REVERSIBLE FANS
Move air in either direction with the same high efficiency.'Can be reversed manually or automatically. For many cooling'and drying processes and for ventilating jobs where intake may be desired under some conditions and exhaust under other condi tions. Available in 28 in, 36 in. and 44 in. fans diameters, in duct section or double-ring construction.
ROOF VENTILATORS
The Vertijet (shown) or the Automatic Airjet attain unusual efficiency and economy through extreme simplicity of design. Lids open automatically when the fan is on, close weather tight when it goes off. Other ventilators include a Rotary Ventilator and a new Reversible Roof Ventilator which also meets all the requirements for a blackout unit.
OTHER HARTZELL VENTILATING EQUIPMENT: Centrifugal blowers, man and materials cooling fans, intake air units, unit heaters, aluminum and plastic adjust able-pitch fans for cooling tower and heat exchanger applications and mine ventila tion.
1392
m
Air System Equipment cSnuug^Fim..
ILG Electric Ventilating Co.
2880 North Crawford Ave., Chicago 41, 111.
Offices in more than 40 Principal Cities
ILG PROPELLER FANS, CENTRIFUGAL FANS, ROOF VENTILATORS
Tested and rated by NAFM, PFMA and ASHVE code.-Capacities guaranteed.
Type "X" Ex plosion Proof
Fans carry UL certification of suitability for all
Class 1, Croup D hazardous appli
cations.
Type
"TA*'
Tubeaxial Duct
Fans for pres
sures up to 0.6 in.
Easily installed
duct section for
vertical or hori
zontal use.
ILG DIRECT-CONNECTEDSELF-COOLED MOTOR PROPELLER FANS--Exclu
sive self-cooling feature: motor covered for protection against corrosive and con taminating exhaust air, but cooled by a vent, the entrance of which is outside the
exhaust area. Motor never "gums up" from contact with foul air . . . saves on power costs . ^ . practically no maintenance required. Direct drive assures permanent align
ment. Exceptionally quiet operation. Wide range of sizes.
Volume Blower Type "B" left--Small
volume, low pressure, quiet running. Cast
iron base. Universal discharge positions, 7 capacities.
Volume Blower Type "P" left--For exhausting dust, fumes, vapors. Four discharge positions, 7 capacities.
ILG DIRECT-CONNECTED CENTRIFUGAL FANS, NEW AIRFOIL TYPE BC above, far left--Motor load is constant for wide range of volume and static pressure changes. Direct drive design with motor partially recessed, 10 sizes. Belt-drives in 12 sizes.
TYPE LSQ--Direct-connected propeller fan type featuring low silhouette, low maintenance and high capacity, 5 sizes up to .6 in. static pressure.
TYPE RVS--Centrifugal fan type, ideal for low volume requirements. 9 sizes up to .5 in. static pressure. 17 in. high above curb. Optional without dampier, Type RAS, 13 in. high above curb.
PRV POWER ROOF VENTILATORS--Centrifugal fan type, shown above left, lor exhaust from vertical flues or duot systems. Direct drive, self-cooled motor. IN on-overloading, backward curved wheel. 10 sizes. Up to l)t> in. Static Pressure.
1393
; *