Document n9nG5j0Dv6NBzeqBoDV40z0mw
FOR COMPANY USE ONLY
TEST AUTHORIZATION AND
. dat f
TEST CONCLUSION NO. TA-C- 73-39S
July 17, 1973
PURPOSE OF TEST:
To demonstrate that a 50% increase in dryer capacity can
be obtained by adding a third rack and placing them parallel to air flow
instead of at right angles to it.
TEST DETAILS:
1. Box out one dryer door six inches to provide space for third rack.
2. Place three racks of material in this dryer parallel to air flow.
3. Dry a typical one-day dryer; i.e., 1-amino--2,4-dibromoanthraquinone in a two-rack and a new three-rack dryer. Compare the amount and dryness . of the material dried in a two-rack dryer versus three-rack dryer during a five-day period.
4. Repeat Step 3, using a two-day dryer, i.e., "Sevron" Yellow R, for a ten-day period.
RESULTS OF TEST : The test was successful. Five thousand one hundred and twelve pounds of 1-amino-2,4-dibromoanthraquinone was dried in the three-rack dryer versus 3,375 lbs. for the two-rack dryer. This was a 51% increase. The % moisture on all racks was nil. Six thousand five hundred and ten pounds of "Sevron" Yellow R was dried in the three-rack dryer versus 4,397 lbs. This is a 48% increase. The dryness of both the two-rack and three-rack were comparable.
RECOMMENDATIONS: Convert the remaining two-rack dryers to three-rack dryers.
DISTRIBUTION: J. Pohl H. Terss L. Files
H. Lake F. Laucius E. Lewis
J. R. McCloskey R. T. McNally J. A. Moffett M. S. Moores D. 0. Miller (3) E. fC. Nelson
J. D. Putnam (3) R. R. J. E. Kuty A.
CHIEF SUPERVISOR, OPERATIONS
AUTHORIZED BY:
SUPT.'; MANUFACTURING (OH DELEGATES)
/lu
CH. SUPVR., TECH. OB PLANT ASSIST.
DATE
SUPT,, "TECHNICAL OP ANY)
N32964
DATE
DUP050467612