Document n9moLEg8aVm4jmzEpyDKON2O1

INTERNAL. CORRESPONDENCE UNION CARBIDE PLASTICS COMPANY RIVER ROAD, BOUND BROOK. NEW JERSEY Mr. G. J. Rizoak/k. A. DeOoudres c.p.r Union Chrt>lde Plasties Company I.cciio. Bound Brook, 3ew Jersey C..r Mr. V. OdIcLou-^i/c. Martino Mr. E. F. Jenny Mr. B. C. xmc.Mr. R. Peek/E. Legist/A. SOreiyi 0l>H January- 30, 1961 Aotwerlaf Miir 4of* . Sublet Development Run Report BW5A-40B5 Brown 135 Batch 2 3*9** So. 669 Report by? E. ? Stuhr Pete of Run; January 20, 1961 fTortuct nail 2?*SA-15S?5 Brown 135j soft ,;rade, 500 lbs. Unit: mu r/3; Department Oik-3 Followed by: E. I'-. Stuhr and V. Oolelouah 3*9k Author an*! Date; A. TSzemss; January 19, 19SI Customer ana Use: Samples -.`or Hares and Cutler Hrewuer; heavy duty industrial electrical equipment. Is thVr- first run ol* product; Yes Will transfer te requested t So Recoaamdafelant la view of the poor impact strength, a second batch of material should 'lib produced using e lower ratio of boll weight to raw tnlx weight end cutting back the mllllhg cycle from three hours to fcvc hours. . Discussion: ' This material Is e hid> heat resistant-hi<gb impact strength molding material slEllar to, but having better properties than BMZ-5250. 33te Improved properties are attributed tc the use of e hicpheool *S" modified, one-step resin.,. .BKHA-2512. The renin for this sun vac coarse crushed io the Department 014-3 Orundler Crusher. A 97$ resin-3$ aliens mix was prepared and ball milled for two hours In Mill iJ3, Department 014-3....the pulverized resin van identified as BRJJA-402O. . A 50C pound ran cdx was prepared using the following fonule: B3KA-4C20' (Pulv. Resin) 1%1-132-A (fine Stearate) PIJ-J3-AA (Brown Dtaber) KJJ-1QI-AS (Rod I^e) RM-li'-O (long- fiber ohbestos) 32.00$ 2.25$ 2.50$ 0.25$ 63.00$ usm SC-EEI-0715 UCASB00917952 -2- Dervelopneat Run Report BffiA-4025 Brovn 135 Die nix vas charged into Mill #3, OlU-3, which conrtaload 1700 pounds of balls, and vac allied ftxr 3 bouro. The flolBhed material vaa then packed out to drums. The plasticity was within specifications (CCT 25-3 secs*), and the appearance was excellent. However, the Impact strength was too low (.662 and .692 rt-lba/lneb of notch), and consequently no further testing was done....Impact strength should have been approximately ,900 or blgier. It is suspected that the low Impact strength was caused by one or both of the following conditions, both of which would tend to break-up the asbestos fibers and consequently aanse low Impact strength. 1. Too blg> a ratio of ball weight to raw mix weight.3*4 to 1 In this run. 2. Too long a mining cycle....3 hours In this ran. A second rue will oe scheduled for the week of January 30. A ball weight to raw mix wel.^it ratio of 2.to 1 will be used and the mllline cycle will be cut to two hours. EPS :03a E. ?. Stuhr, Jr. UCASB00917953