Document n9jQOmKbvmj51Gm7okNo4QLnR
dBA
IMPERATIVE IIS
110
103
100
98
FIG 45-7 --Permissible (low nsk) noise exposures for interrupted noise The parameter is sound level dB(A) (the solid lines), and permitted expo sure cycles per day (the dashed lines)
is on intermittently during the work-day, the recommended allowable exposure time may be determined by consulting Fig 45-7, which shows the relationship between the duration of the "on-time" between the noise bursts (ordinate), and the allowable A-scale level The broken contours show the number of permitted exposure-cycles ("on-time"--"off-
time" combinations) per day, calculated for a working day of 480 minutes
Example If the A-scale level is 100 dB and the noise is habitually on ("on-time") for 10 minutes the recommended allowable "oFtime" between noise bursts is the ordinate value of the intersection of the 10 minutes and the 100 dB contour In this case it is approximately 16 minutes or approximately 15 exposure-cycles per day
Table 45-B shows both overall and octave band levels of three typical industrial noises Asterisks indicate octave bands most impor tant to hearing conservation
Control of Noise-Exposure
Environmental control
The environmental control of noise-exposure requires highly technical skills and should be undertaken only with the help of acoustical consultants There are a number of books written on this subject, see "Ref erences " Noise-exposure may be controlled at the source, by changing the path, and by protecting the receiver (Fig 45-8)
Reduction m amount of noise produced by the source This method is the most satisfactory for hearing conservation purposes, but it is not always practical or possible A reduction in the amount of noise produced by a machine or a machining process may be accomplished by
TABLE 45-B OCTAVE BAND ANALYSIS OF THREE TYPICAL INDUSTRIAL NOISES
Sound Pressure Level in dB, re 0 0002 dynelsq cm
Overall Level
37 5 to
75
Octave band (Hz)
75 150 300*
600*
1,200*
to to
to
to
to
150 300 600* 1,200* 2.400*
103 84 101 91
95 84
85 87 93 97 98 85 84 85 84
'Octave bands specified in the tentative heanng conservation level
93 85 84
95 81 86
2,400 to
4,800
97 80 88
4,800 to
9,600
87 82 84
1529