Document n9Xkevrqm18L4Oo1BBJVj15x8
PLAINTIFF'S FJCHIBJT
Inlar Office
Personnel and Organization staff
Hr. M. E. Lindsey, Safety Engineer Sh&ronville Plant
ec R. D. Byrom S. Grendel, M.D.
R. M. Hric
Subject: Asbestos
23 August 1983
Referencea: l) Volume 29, Code of Federal Regulations, 1910.1001 2) IRAM Industrial Hygiene Bulletin Ho. 1*, 4a, 4b
As requested, the samples which you submitted to the Industrial Hygiene Laboratory on 12 July 1983 were analysed for asbestos content. This was in response to concern expressed by plant Heat Treat Department employees that exposure to air
borne dust of these materials might present an asbestos inhalation hazard.
Test results, as shown on the attached data sheet, reveal that three of the six samples contain significant amounts of asbestos. These results along with a copy of the OSHA asbestos standard regulations should be shared with powerhouse employees, pipefitters and pipeooverers with potential exposure to the asbestoscontaining material, and the Onion Health and Safety Representative.
.
Exoessive exposure to airborne asbestos fiber and dust may cause seriouB irrevers ible adverse health effects many years after exposure. These include asbestosis, a progressively disabling lung disease, and cancer of the respiratory tract and of the chest and abdominal cavities. The long latency period between exposure and when disease may develop emphasizes the importance of preventive industrial hygiene control methods.
Steps must be taken to assure that employees with potential exposure to asbestos
are aware of these health effects and that proper precautions are taken to
eliminate asbestos fiber inhalation. These include wet methods of dust suppres
sion, use of effective respirators, vacuuming, local exhaust ventilation, debris
containment, and protective clothing.
.
If there are questions regarding this report or industrial hygiene control methods for asbestos, please call us at 33-78935*
3b Attachment
Libardo Latorre, Industrial Hygienist Senior Industrial Hygiene Services Employee Health Services
8006 0091
SCF-FORD-3361
PRODUCED BY FORD
XNDOSTRIAL HYGIENE SERVICES ENVIRONMENTAL HEALTH AFFAIRS
EMPLOYEE HEALTH SERVICES
Sharonville Transmission Department 280, Heat Treat, Pusher No, 7
Laboratory Number
83-1319 83-1320
83-1321 83-1322
83-1323 83-1324
Sample Source
Peroent Asbestos
Debris vest side of furnace
12Jf Chrysotile
Radiant tube gasket
ND*
Door gasket entranoe end
9056 Chrysotile
Debris east side of furnace
ND*
Pipe wrapping from overhead
ND*
Flat gasket material stock No. 68-40-510 8056 Chrsotile
ND* = None detected, detection limits one peroent.
ANALYSIS} Central Laboratory Services by Polarized Light Microscopy with dispersion staining. EPA interim method.
ANALYST} K. H. Berry, ABIH Certification No. 1531
8006 0092 PRODUCED BY FORD