Document n9J2VKj7QRJYw83MQyzOmpZmz

M jd / D^* c ETHYL CORPORATION INTER-OFFICE To : T. R. Robinson, M.D, Address : BRP From : J. D. Watts Subject : Vinyl Chloride Monomer Survey Hydrocarbon Area Address ; BRT/BRP Date : Nov. 14, 1975 As part of the comprehensive survey, an industrial hygiene evaluation was made of the airborne contaminants associated with the production of vinyl chloride monomer. Summary and Recommendations The environmental sampling scheme indicates that the levels of vinyl chloride monomer (VCM) are usually below the OSHA standard of 1.0 ppm on a time weighted basis. Furthermore, only five of 21 samples collected (24%) exceeded the action level of 0.5 ppm. Also, the levels of many other hydrocarbon contaminants (the spectrum from methyl chloride to perchloroethylene) were well below their re spective standards. The highest VCM concentrations were localized on the ground floor of the #2 EDC plant (compressor P23A) and in the rundown tank area. From an environmental standpoint and under restrictive operating conditions (production rates less than 50% of maximum), there appears to be no hygienic problem and thus, no additional control measures are recommended. Description of Process - Recognition Vinyl chloride monomer is used predominantly in the manufacture of polyvinyl chloride but is also utilized as an intermediate in the production of 1,1,1 trichloroethane. It is manufactured by the cracking of 1,2 dichloroethane (EDC) as shown in the following reaction Cl, CH2C1CH2C1 + heat -------- --------- ^ CHC1 = CH2 + HC1 EDC VCM The gas mixture from the furnace is quenched, partially condensed, and fractionated into VCM product, by-product HCl, and recovered EDC for recycle to the process. Seven employees are potentially exposed to this cancer-suspect agent including the following operator job codes: control room (2), compressor house, tower, furnace cracking, tank car loader, and process attendant. The compressor house man and loading operator are potentially exposed to the higher VCM concentrations due to the collection of quality control samples and disconnecting tank car lines. EC 4327 Nov. 14, 1975 Page 2 Evaluation Samples were collected at fixed station points (#2 EDO plant, control room, VCM/HCl column, and rundown tank area) at a sample rate of approximately 1.5 liters/minute. The hydrocarbon contaminants were adsorbed on activated charcoal with subsequent analysis by gas chromatography. The survey results are shown in the following appendix. JDW:sp cc: H. M. Taylor Enclo. u. D. Watts Industrial Hygienist APPENDIX VCM Plant Survey Results AREA: #2 EDC Plant (North) Component TLV (ppm) Benzene Butane Carbon Tet Chloroform 1,1 DCE EDC Ethyl Cl Methyl Cl Methylene Cl Per Propane Toluene 1,1,1 TCE Tri 10 10 25 100 50 1000 100 200 100 100 350 100 VCM Vinylidene Cl Unk^ Unk2 Unk3 1 10 Weather Conditions Sampling Dates and Concentrations (ppm) 8/29 10/7 10/8 10/21 0.02 0.11 < 0.04 0.07 0.12 0.16 0.53 0.03 0.15 0.21 0.01 0.24 0.24 0.09 0.07 5.4 0.24 0.09 0.06 0.06 0.13 4.45* 0.18 PC, 850 ESE-E Cloudy, 70o, NW 1.06 0.24 0.16 0.06 0.34 0.02 0.035 < 0.03 1.26 0.05 0.27 < 0.02 < 0.01 1.8 0.01 < 0.005 0.01 0.13 0.49 0.05 X X X Cloudy-PC, 75,variable Clear, 76, S EC 4329 II APPENDIX VCM Plant Survey Results AREA: #2 EDO Plant (Ground Floor) Date Location 10/7 South Compressor P28A 10/8 Middle Compressor P28-C-P28D Component Benzene EDC Ethyl Cl Methyl Cl Per Propane Tri VCM Vinylidene Cl Concentration < 0.04 6.8 0.27 0.08 0.06 0.085 0.095 0.78 0.06 Butane EDC Ethyl Cl Methyl Cl Per Propane Toluene Tri VCM 0.07 1.83 0.25 0.16 0.04 0.45 0.01 0.04 0.175 F.C 4330 Ill AREA: #2 EDC Plant Component 10/7 Benzene Butane EDC Ethyl Cl Methyl Cl Methylene Cl Per Propane Toluene Tri Unk VCM Vinylidene Cl < 0.04 6.64 0.31 0.085 0.06 0.37 0.08 0.42 0.02 10/8 0.075 3.7 0.33 0.19 0.04 0.97 0.02 0.03 0.24 0.02 10/17 0.13 1.06 0.26 0.32 0.07 5.08 0.01 X 0.12 Location Between Compressor House & Production Unit EC 4331 IV AREA: Control Room Component 10/9 Benzene Butane Carbon Tet Chloroform 1,1 DCE EDC Ethyl Cl Methyl Cl Methylene Cl Per Propane Toluene 1,1,1 TCE Tri VCM Vinylidene Cl Unk 0.08 0.8 1.8 1.85 0.06 0.03 < 0.025 0.05 0.15 Weather Conditions 10/14 10/17 10/21 0.21 0.14 0.4 0.63 0.22 0.02 0.15 0.09 2.26 0.02 0.51 0.11 0.03 X Clear-PC, 80, E-SE 0.04 0.56 0.4 3.06 0.14 36.2 0.05 0.135 0.04 X Cloudy, 70 WNW-MW 0.23 0.185 0.06 2.37 < 0.06 0.11 35.2 0.04 0.26 0.05 0.19 < 0.01 X Clear, 76, S 433? V AREA: VCM/HC1 Column Component 10/9 Butane 1,1 DCE EDC Ethyl Cl Methyl Cl Methylene Cl Per Propane Toluene 1,1,1 TCE Tri VCM Vinylidene Cl Unk 0.05 0.31 0.34 0.20 0.03 1.06 0.03 0.05 0.57 10/14 0.03 0.02 0.06 0.29 0.25 0.01 0.24 0.07 0.24 X 10/17 0.25 0.03 0.30 0.295 0.06 0.28 0.59 0.06 0.22 0.04 X 10/21 0.15 0.23 0.07 0.03 0.24 0.07 0.09 0.03 0.01 0.07 0.12 X PC a4333 VI AREA: VCM Rundown Tanks Component Butane Carbon Tet 1,1 DCE EDC Ethyl Cl Methyl Cl Methylene Cl Per Propane Toluene 1,1,1 TCE Tri VCM Vinylidene Cl Unk 10/9 0.05 0.66 0.31 0.10 0.02 0.03 < 0.02 0.07 1.98* 10/14 0.06 0.22 0.05 0.01 0.06 0.55 0.11 0.01 0.06 0.08 0.08 X 10/17 0.31 10/21 0.16 < 0.01 0.06 0.29 0.03 0.17 { 0.03 0.12 0.01 0.25 0.07 0.02 0.05 0.05 < 0.01 X 0.075 0.01 0.01 0.02 2.75* X EC 4334