Document n906vgXj4pgGKe4GEeKVk5r98
162
CHAPTER 8
1956 Guide
Table 6.
Approximate In Air at
Limits of Ordinary
Flammability Temperatures
of Single Gases and Pressures*
and
Vapors
Gas ob Vapor
Lower Limit Percent by
Volume
Upper Limit Percent by
Volume
Closed Cupb Flash Point
Fahrenheit
NBFU
CLASSIFI CATION0
Acetyldehyde -- Acetone............... Acetylene........... AUyl alcohol....... Ammonia..........
Amyl alcohol. ... Amyl chloride. .. Amylene.......... Benzene (benzol) Benzyl chloride..
4.0 2.5 2.5
57 12.8 80
2.5 15.5
26'6
II
II
1.2 100 in
1.6 1.6 1.3 1.1
7.1 6.8
"ii 1
140 m
Butane............... Butyl acetate -- Butyl alcohol Butylene........... Carbon disulfide
1.8 1.4
8.4 15.0
"84 in
1.7
2.0 1.2
9l7 50
-22 I
Carbon monoxide,.. .. Crotonaldehyde........... - Cyclohexane................ Cyclopropane............... Decane.........................
Dichloroethylene (1, 2) 'Diethyl seienide.......... Dioxane....................... Ethane...................... . Ether (diethyl)...........
Ethyl acetate............. Ethyl alcohol.............. Ethyl bromide............ Ethyl celioeolve.......... Ethyl chloride............
Ethylene........... ................... Ethylene dichlonde............. Ethyl formate...................... Ethyl nitrite--.................. Ethylene oxide.....................
Furfural (125 O.................. Gasoline (variable) . .... -- Heptane........ ...................... Hexane.......... .................. Hydrogen cyanide...............
12.5 2.1 1.3 2.4 0.67
9.7 2.5 2.0 3.1 1.8
2.2 3.3 6.7 2.6 4.0
2.7 6.2 2.7 3.0 3.0
2.1 1.4-1.5
1.0 1.2 5.6
74.2 15.5 8.4 10.5 2.6
12.8
22^2 12.5
11.5 19.0 11.3 15.7 14.8 28.6 15.9 16.5 50 80
7.4-7.6 6.0 6.9 40.0
55l
115 57 "54 -49 28 54 i04 -58
56 -4 -31
140 -50
25 -15
n
I
in n
II I
n
II
in
1
IIII
IIII III
Hydrogen.................... Hydrogen aulnde. -------- ... Illuminating gas (coal gas).. Isobutyl alcohol................... Isopentane............................
Isopropyl acetate................. Isopropyl alcohol................. Methane............................... Methyl acetate..................... Methyl alcohol.....................
Methyl bromide...................| Methyl butyl ketone........... Methyl chloride.......... ......... Methyl cyclohexane............. Methyl ethyl ether..............
Methyl ethyl ketone........... Methyl formate................... Methyl propyl ketone.......... Natural gas (variable)......... Naphtha (benzene).............
Naphthalene........................ Nonane................................ .Octane........ ......................... Paraldehyde..................... - Pentane................................
4.0 4.3 5.3 1.7 1.3
1.8 2.0 5.0 3.1 6.7
13.5 1.2 8.2 1.1 2.0
1.8 5.0 1.5 4.3 1.1
0.9 0.83 0.95 1.3 1.4
74.2 45.5 33.0
15.0 15.5 36.5 14.5
8.0 18.7 ioli
9.5 22.7
8.2 13.5 6.0
2.9 3.2 7^8
82
43 53
i4
52
"25 -35
30 -2
2CM10 176 88 56
in
I
II
11 1 II I III III III II
Air Contaminants
163
Table 6. Approximate Limits of Flammability of Single Gases and Vapors
In Air at Ordinary Temperatures and Pressures* (Concluded)
Gas or Vapor
Lower Limit Percent by
Volume
Upper Limit
Percent by Volume
Closed Cupb Flash Point
Fahrenheit
NBFU
CLASSIFI
CATION0
Propane................................ Propyl acetate..................... Propyl aloohol..................... Propylene............................. Propylene dichloride........... Propylene oxide................... Pyndine............................... Toluene (toluol).................. Turpentine........................... Vinyl ether.......................... Vinyl chloride...................... Water gas (variable)............ Xylene (xylol).......... ..... '..
2.1 1.8 2.1 2.0 3.4
2.0 1.8 1.3 0.8 1.7
4.0 6.0 1.0
10.1 8.0 13.5 11.1 14.5
22.0 12.4 7.0
27.6
21.7 70
6.0
58 II 59 U 60 II 74 III 40 II 95 III
63 II
* Adapted from: Fireand Explosion Hazards of Combustible Gases and Vapors, by G.W. Jones; Chapter 13, Industrial Hygiene and Toxicology, edited by F. A. Patty (Intexscience Publishers, 1948); Properties of Flammable Liquids, Gases and Solids (Associated) Factory-Mutual Fire Ins. Cos., January (1940); and National Fire Codes for Flammable Liquids, Gases, Chemicals and Explosives--1945 (National Fire Protec tion Association).
b Closed cup refers to the equipment used in flash point determinations. 0 From Standards for Storage, Handling and Use of Flammable Liquids (National Board of Fire Un derwriters, No. 30, July 1954)..., _
vestigators frequently experience difficulty in obtaining dust suspensions of uniform dispersion, and this should be kept in mind when comparing results from several sources.14
Minimum explosive concentrations of airborne dusts already tested range from 0.01 to 0.5 oz per cubic foot, or 10 to 500 grams per cubic meter of air. Maximum pressures generated have been reported as high as 500 psi, although they are more likely to be of the order of 50 psi. Investiga tions on the flammable characteristics of dusts are currently made at 0.1 and 0.5 oz. per cubic foot.15-21
ATMOSPHERIC POLLEN
Properties of pollen grains discharged by weeds, grasses and trees and responsible for hay fever, are of special interest to designers of air cleaning equipment (see Allergic Disorders in Chapter 7, and Air Cleaning, Chap ter 34). Whole grains and fragments transported by the air range chiefly between 10 and 50 microns in size, but some have been measured as small as 5 microns, and others over 100 microns in diameter. Ragweed pollen grains are fairly uniform in size within the range of 15 to 25 microns. Pollen grains can be removed from the air more readily than the particles of dust prevalent in outdoor air or produced by dusty processes, since the latter predominate in the range of 0.1 to 10 microns in size.
Most grains are quite hygroscopic and therefore vary in weight with the humidity. Illustrations and data on individual pollen grains are available n the botanical literature.22 - 23 24 Geographical distribution of plants known to produce hay fever is also recorded.26- 26
The quantity of pollen grains in the air is generally estimated by exposing an adhesive-coated glass plate outdoors for 24 hr, and then counting cali brated areas under the microscope. Methods are available for determinlng the number of grains in a measured volume of air,26- 2728 but their greater accuracy has not caused them to replace the more simple gravity slide method used for most pollen counts. Counting technics vary some what, but the daily pollen counts reported in local newspapers during the