Document mz847DbJBKp0Znk4aBgp4n3d

DATE: UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS 77 WEST JACKSON BOULEVARD CHICAGO, IL 60604 APR O4 2019 SUBJECT: FROM: CLEAN AIR ACT INSPECTION REPORT InSolution, LLC, Indianapolis, Indiana Charles Hall, Environmental Engineer ('... ~ AECAB (MN/OH) THRU: Brian Dickens, Section Chief AECAB (MN/OH) TO: File, InSolution, LLC, Indianapolis, Indiana BASIC INFORMATION Facility Name: InSolution, LLC Facility Location: 5157 East 64th Street, Suite A, Indianapolis, Indiana Date of Inspection: 25 March 2019 EPA Inspector(s): 1. Charles Hall, Environmental Engineer 2. Marie St. Peter, Environmental Engineer Other Attendees: 1. Aaron Emmert, Systems Analyst, Enviro-Max, Inc. 2. David Williams, Vice President, Enviro-Max, Inc. Purpose of Inspection: chloroflurocarbon reclaim Facility Type: chloroflurocarbon reclaimer Regulations Central to Inspection: 40 C.F.R. Part 82, Subpart F Arrival Time: 2:20 p.m. EDT Departure Time: 3:45 p.m. EDT Inspection Type: lZl Unannounced Inspection Announced Inspection 1 of2 OPENING CONFERENCE IZl Credentials Presented ~ CBI warning to facility provided The following ini:ormmion was obtained verbally from ATTENDEEtS), unless otherwise noted. Process Description: InSolution, LLC (INS) receives R-22 in reusable 30 or SO-pound cylinders. INS weighs the cylinder and tests the contents of the cylinder for refrigerant purity to be assured that no other refrigerants are mixed with R-22. INS then records the weight and purity. If the contents of the cylinder are found to be 100% R-22, INS then uses a Van Steenburgh JV-90 refrigerant reclaimer to remove contaminants including oil and moisture. INS then stores the reclaimed refrigerant in a labeled "Pure" 1000-pound process storage tank. If the contents of the cylinder are less than 100% R-22, INS empties the cylinder into a labeled "Mixed" 1000-pound product storage tank. INS is not equipped to separate refrigerants, and sends the "Mixed" tank to a qualified third party when the "Mixed" tank is full. When the "Pure" tank is full, INS collects and sends a sample to an outside testing laboratory. The site representatives provided a copy of a sample analysis report. It is attached. Ifthe sample passes all of the parameters including moisture content, acidity, chloride content, and purity, INS fills 30-pouud cylinders from the 1000-pound product storage tank for sale. TOUR INFORMATION EPA toured the facility: Yes Data Collected and Observations: were not taken during this inspection. Photos and/or Videos: were not taken during this inspection. Field Measurements: were not taken during this inspection. SIGNATURES Lead Inspector: Section Chief: 2 of2