Document mydM04v6nN8oGj1mDO2J2rzZ

Boilers Pacific Steel Boiler Corporation Manufacturers of Pacific Steel Heating Boilers, Pacific Circulating Tanks Waukegan, Illinois and Bristol, Pennsylvania pacific STEEL HEATING BOILERS Pacific Steel Heating Boilers are built for steam or hot water heating using soft coal, hard coal, oil, gas, or wood as fuel. For Burning Soft Coal Smokelessly They are constructed of steel accord ing to the A. S. M. E. Code for building low pressure steel heating boilers. Every joint and seam in the Pacific is electrically welded and e^tch boiler is built and tested to a pressure many times its normal working pressure un der the supervision of an inspector stationed in our plant by one of the largest insurance companies. Far Soft or Hard Coal, Gas or Wood ' Because of the compact design. Pacific Boilers often save from 25 to 4Q per cent of the boiler room floor space required by other steel firebox boilers, (see dimensions given on opposite page). The catalog ratings on Pacific Boilers are based on heating surface with steam at 2 lb. gauge pressure, hot water at 180 deg. at boiler. Any Pacific Boiler will carry its full rated load in direct cast iron radiation. Extra capa city must be allowed for exposed piping, storage tank, pipe coils or indirect radiators and for buildings, where normal temperatures below 70 deg. fahr. are to be maintained. For Burning Oil 604 Pacific Steel Boiler Corporation ______ ___________________ Boilers PACIFIC LOW WATER LINE DIRECT DRAFT AND SMOKELESS BOILERS Net Rating Diameter Smoke Conrec. Inches Diameter Stack Inches | Minimum Height Stack, Feet . || Grate Area. Square Feet Heating Surface, Square Feet | Size of Return, Inches || Length Overall 1 j Width Overall Height Boiler Length Base Width Base Height Base j Length for Aihpit Width for Aihpit | Depth for Ashpit | V- *u230o0_ce OX tS O2 'S'jj N CO 2291 2100 59'A 2292 2300 59>/2 2293 2500 591/2 2294 2700 59`A ms 2900 59Vi 7331 3500 68/2 2332 4100 68Vi 2333 4830 68/2 2334 3300 68/2 2401 6200 68 740? 7000 68 2471 7650 78 2472 8200 78 2473 8750 78 2474 9250 78 2321 10000 82 2327. 12000 82 2523 13000 82 2600 14000 90 2601 16000 90 2602 17000 90 2603 18600 90 2671 20000 98/i 2672 22000 98i/2 2673 24000 98/2 2674 26400 98V? 2731 2800C 106 2752 31000 106 2/33 3400C 106 8841 ' 120 8842 8843 ' 120 120 14 13 55 7.3 14 13 55 8.1 14 13 60 9.0 14 13 60 9.8 14 13 60 9.8 17 16 60 11.2 17 16 65 13.1 17 16 70 14.J 17 16 70 15.0 18 17 70 18.8 18 17 75 19.9 22 21 70 20.8 22 21 75 20.8 22 21 75 22.1 22 21 80 23.4 24 23 80 23.0 24 23 85 24.4 24 23 90 25 9 30 29 85 28.0 30 29 90 28.0 30 29 90 29.7 30 29 95 31.4 32 31 95 33.3 32 31 100 35.2 32 31 110 37.1 32 31 115 37.1 36 35 105 39.5 36 35 110 41.6 36 35 120 41.6 40 40 167 186 204 222 241 259 311 363 415 466 496 563 604 646 687 753 850 899 1022 1154 1219 1350 1467 1627 1786 1945 2073 2278 2482 53 53 53 53 53 63 63 63 63 63 63 84 84 84 84 84 84 84 84 84 84 84 84 10 5 10 5 10 5 10 5 12 6 12 6 SB 39 39 86'/, 39 S51 39 39 83l/j 43'/, 95'/, 43'/2 107i/S 43'/, l19'/2 43V, 118 50 124 50 108 58 114 58 120 i_58 126 58 122 62'/, 134 62'/, 140 62'/, 124'/2 70'/, !SB 70V, Wi 154'/. 70'A 143/2 78V? 155'A Wl 167VJ 1791/2 78'/, 157 86 169 86 181 86 162'/, 95/2 174'A 95'A 156'A Wx 71 52>/2 36 71 581/2 36 71 64'/, 36 71 70V, 36 71 76'/, 36 8l'/2 58'/, 4oy, 81V, . 82^2 4oy, 81 '/2 40*4 'SI'/, 94'/, 403/, SB ioo( 47 47 91 82'/2 54 91. 88'/; 54 91 54 91 100'/2 54 96 94>/i 59 96 106'A 59 96 112'/, 59 106 94'/2 67 IBB106 67 (06 67 106 1241/2 67 118 ll2'/3 753/2 UK118 75'/, 118 75'A 118 148'/! 75'A \m126 83'/, 126 83'A 126 148/2 83'A im140 W7 140 96Vi 140 l49'/i %'/, 12. 29 30 12 33 30 12 37 30 12 41. 30. 12 41 .30 12 41 3434 12 49 3434 12 53 34% 12 57 3434 12 61 41 12 65 41 12 57 48 12 57 48 12 61 48 12 65 48 . 12 57 53 12 61 53 12 65 53 12 61 61 . 12 61 61 12 65 61 12 69 61 15 65 691/2 15 69 69'/, 15 73 69V, 15 73 69'A 15 69 77V$ 15 73 .77'/, 15 73' 77>/5 18 18 - 16 2 Z U CO JL, 2 a -j O Pacific Boilers are constructed with smoke outlet at the rear and all of the tubes, both upper and lower banks, are cleaned or removed from the front of the boiler through the front flue doors. Space at rear of boiler is not necessary. . . .... Complete catalog showing all types and sizes Pacific Boilers will be furnished on request. 605