AMERICAN STANDARD
r
20 THROUGH 750 HORSEPOWER for oil--gas--combination gas-oil
HIGH or LOW PRESSURE STEAM or WATER
45 00004$
Bulletin 96-12-96A
I
CoSYngM 1965 by A*ne*,cn Su-Jira Inc
S-M woducl
,, , conl.nCn, .Wort .1
r*l*rrd t* mill niMniti) <h*rtf*| of mr>f kind
nett
,,,M ,,
Kewanee has been building various types of heat generating equipment for over 100 years. During that time we have discussed heat and process steam requirements with thousands of contractors, engineers, and architects. We now have more Kewanee boiler units in service than any two com petitors combined. From these users, installers, and specifiers, we have found that more than basic fundamentals are required to satisfy the needs and desires of today. We have designed the Kewanee Scotch Generator to fill these needs.
FOR EXAMPLE:
MOST USERS WANT Vhe boiler, burner, controls, end accessories under the single responsibility of one reputable manufacturer. The Kewanee Scotch Generator *s a com pletely packaged, factory-assembled unit--designed, engi neered. built and serviced by the largest manufacturer of air conditioning, heating and ventilating equipment.
MOST USERS WANT to use locally available, low-cost fuels to generate heat. Available fuels vary widely in heat content and burning characteristics--from viscous residual oil lo stable light oils--from liquified petroleum gas to by product or manufactured gas. The Kewanee Scotch Gen erator burner is specially designed for any commercially available liquid or gaseous fuel that the customer specifies.
MOST USERS WANT modern architectural design with small space requirements. Building cost and appearance demands minimum space for boiler equipment in addition to the elimination ol unsightly smokestacks. The Kewanee Scotch Generator combines a compact three-pass scotch design with forced draft firing for minimum floor space requirements and only a stub vent to discharge products of combustion.
MOST USERS WANT maximum. not minimum, safety of operation. Compliance w.th local and nalional codes means that equioment conforms only to minimum safety standards. The Kewanee Scotch Generator provides, as a standard for all units, safety features that exceed all mini mum requirements. Kewanee safety features include elec tronic flame safeguard, updraft gas flow, pre and post purge of combustible gases, dual operating limit controls and dual gas valves for maximum customer protection.
MOST USERS WANT to burn the least possible amount of fuel. Boiler unit efficiency depends on how well the fuel is burned and how effectively the boiler heat transfer surfaces absorb the heat. The Kewanee Scotch Generator utilizes efficient forced draft burner equipment to promote combustion and extract the maximum energy from each pound of fuel consumed Large furnace tube and water-back design provide a greater ratio of primary to secondary heating surface Primary heating surface transfers more heal per square foot than secondary surfaces because it is ex posed to the radiant heat of the flame as well as hot gases.
MOST USERS WANT maximum service life without major costly repairs. Unless preventive measures are in corporated into fhe basic design of the boiler, expansion and contraction set up destructive forces within the unit. The most detrimental of these forces is the stress put upon components by temperature differential. That is the variance in heat intensity from one point to another within a single part or component. The Kewanee Scotch Generator pro vides separate rear tube sheets at the end of the first and third passes, thereby reducing stresses which contribute to metal fatigue and resultant early failure.
MOST USERS WANT freedom from frequent replace ment of parts which burn out crack, or deteriorate with use. Healing surfaces (steel backed by water) have a greater resistance to deterioration than metal baffles, re fractories. or seals whjch require periodic repair and replacement. The Kewanee Scotch Generator water-back design requires refractory only in the burner combustion zone--no refractory, no baffles, no seals are necessary in the rear ol the boiler.
MOST USERS WANT easy maintenance. Since all equip ment requires oiling, checking, and cleaning, ease of maintenance is an important consideration. The Kewanee Scotch Generator features "one-man" maintenance. Motors and controls may be checked from floor level. Large front and rear openings provide easy access to boiler tubes without disconnecting or removing any controls or components.
MOST USERS WANT a quality product backed by national testing standards. "Kewanee--The Standard of Ouality in the Industry"--is our hallmark of excellence. Kewanee Scotch Generators meet or exceed ASME and UL standards, and are constructed to meet any customerspecified insurance or local code requirements.
MOST USERS WANT local service facilities and replace ment parts. Down-time for repairs, whether on space heat ing. or process applications, must be held to e minimum by having qualified servicemen and ample pads stock readily available. The Kewanee Scotch Generator is backed by 170 local service outlets that furnish start up and 90-day free service after installation, and maintain a stock of repair parts for continued equipment service.
These ere some of the often overlooked features that you--the user, the con tractor, or specifier--have told us you want and need. Combining all of these features into e balanced design has required years of practical field experience. If you measure these "balanced design" features against those offered by others, we are confident your choice will be ... KEWANEE.
A5 000051
K EWAN EE'
Scotch /
/
/
/
1 LARGE FURNACE TUBE . . . provides abun dant votome tor complete combustion and a greater proportion of primary beating surface. Assures quiet operation.
2 THREE PASS DESIGN . . . provides lull 5 square feet ot heating surface per horsepower.
3 FIRE TUBES ... set in tube sheets, roller expanded, not welded, tor permanent teak proof lit,
4 TOP REAR OUTLET . . . ideally located lor stub stack application.
5 WATER-BACK DESICN . . . eliminates refractory battles and seals. Increases primary heatingsurface
6 REAR TUBE SHEETS . . . separate lube sheets at the end of first and third passes.
7 FRONT AND REAR ACCESS OPENINGS . . . for use of inspection and duning.
8 LARGE STEAM SPACE . . j combined with abundant unbroken disengaging aru, large water content, and integral steam separator assures steady water line and dry quality stum.
9 SHELL . . . extra heavy qual^y plate for strength an..................
'To INSULATION . . . completely insulate mineral or glass fiber on lull drtumfertnc* of shed.
11 JXlttCT-----factory installed heavy puge
enameled steelwlili esi "
"
openings.
12 STURDY STEEL SKIDS . . . otters ease in handl ing and balanced weight distribution.
13 LARGE WATER CONTENT . . . results in less fuel dollar loss in off-cycle and guarantees adequate reserve for fluctuating system demands.
14 SAFETY CONTROLS . . . high safely limits, burner modulating controls . . . factory mounted and wired.
^CONTROL CABINET . . . master programming anUlame safeguard relays, switching relays, motor retie starters, numbered terminal strips, indieating lights . . . mounted and wired in heavy
l> aIt steel, dust-proof cabinet.
^
fitS 000052
i features
B-A.3L,^3STCED
DESIQ-UST
THREE PASS DESIGN
The amount and location of heating surface is of major importance in determining boiler efficiency Although the arrangement of this heating surface into 2. 3 or 4 passes has no effect on efficiency in a well-designed boiler, the number of passes does determine over all dimensions, baffling reQunements and flue gas pressure drop which, in turn, determines fan motor requirements.
The Kewanee Scotch Generator Three Pass Design provides ample well-designed heating surface with a high ratio of primary to secondary heating surface for highest operating efficiency.
Three Pass Design also permits a top rear smoke outlet ideally located for stub stack application and minimum interference with piping and controls Compact proportioned overall dimension permits installation m limned space. Low gas pressure drop through the boiler reduces electrical power costs.
HIGH QUALITY WELDED STEEL BOILER
The Kewanee Generator is formed
from heavy quality steel, joined
@ (ASME)
by deep penetration welds. Qual
ity control begins with the in-
- ' speclion of raw materials, which must conform with rigid speci
fications. and is maintained step by step, throughout the con
struction of each individual unit. Every Kewanee Generator is
inspected, tested, stamped, and a data sheet issued attesting to
the fidelity of workmanship and material of the pressure vessel
and ns components Physical and operational characteristics of
the unit are certified to meet, or exceed. ASME Code requirements.
High pressure shells are x-rayed ar.d stress relieved.
WATER HEATING COILS
Standard Kewanee "Kl" (instantaneous) and "KT" (tank) coils are available tor tew pressure units
ONE SOURCE RESPONSIBILITY The enure generator is listed by Underwriters Laboratory (UL). The complete unit is the responsi bility of one manufacturer. This responsibility in cludes boiler, burner, controls, and accessory equipment.
SEPARATE REAR TUBE SHEETS A rear tube sheet for each gas temperature zone prevents internal stresses which may occur in a single lube sheet exposed to wide temperature differences. This feature prevents short circuiting of hot gases and by-passing of fire tubes with the resultant high stack temperatures.
EASY MAINTENANCE Large access openings in rear combustion chamber and smokebox make rear tube sheets readily accessible for inspection. Large insulated gas-light front doors permit easy inspection of front tube sheet and cleaning of tubes without disturbing burner components, fuel or power connections.
PROVED DEPENDABILITY-PEAK PERFORMANCE Modern concept based on experienced engineering--advanced design and top quality construction--assure highest efficiency, faithful performance, long dependable service. Ratings are con servative-five square feet of fireside heating surface per horse power--provides adequate reserve capacity. Firing raies are carefully maiched to heating surface. Flame size and shape are matched to furnace dimensions. These combined features assure minimum operating efficiency of 80%.
GREATER PRIMARY HEATING SURFACE Totil square feel of heating surface is less important than total effectiveness of heating surface. One square foot of primary heating surface is 4 to 15 times as effective as one square foot of secondary heating surface
PRIMARY
SECONDARY
Brand "A"
:m
Brand ~B~ Brand ~C~
m
Kawanaa Scorch Generator
i
V Kewanee provides more "high value" heating surface . . more 'effective" heating surface than offered by the three other major competitive brands on the market today
WATER COOLED BACK The rear combustion chambc .s entirely submerged in water... no refractory to deteriorate either from chemicals in fuel or from expansion and contraction . . . reduces costly maintenance and repairs . . . absorbs heal rather than reflecting heat on critical tube sheet areas.
Updraft water back design is more expensive to build, but costs the user less. Eliminates regular refractory repairs . . . eliminates baffle leakage which results m lower operating efficiency.
#5 000053
5
KEWANEE4
Kewanee Scotch Generators are available for oil. gas. or combination gas/oil firing Each Kewanee Forced Draft Burner is custom engineered for the generator it fires, assuring long, dependable and economical service. Two series of Kewanee Burners cover the entire range of boiler capacities and fuels.
On Units 20 through 150, for light oil (No. 2 CS12-48) the Oil burners jre of the high pressure mechanical atom izing type, complete with motor; fan; oil pump; nozzle; ignition assembly (direct spark on Units 20 thru 50. gasetectnc on Units 60 thru 150); oil filter; combustion controls and relays necessary for automatic operation. Oil piping is ready for field connection to oil supply.
On Units 60 through 750. for No. 6 or lighter oil. the oil burners are of the low pressure air-atomi2ing type, com plete with motor; fan; air and oil assemblies: nozzle: gas-electric ignition; oil filter; combustion controls and relays necessary for automatic operation. Oil piping is ready for field connection to oil supply.
The air-oil assemblies include air compressor; oil pump; motors; and all necessary accessories to provide the fine oil atomization required for clean, efficient oil firing. A thermostatically controlled electric oil heater maintains uniform oil temperature to compensate for varying vis cosities of residual oils
GAS BURNERS
Gas burners are of the multiport flame retention type, complete with motor; fan; gas-electnc ignition: dual automatic gas valves; manual gas valve: gas pressure regulator: combustion controls and relays necessary for automatic operation Gas piping is ready for field connection io gas supply.
GAS-OIL BURNERS
Gas-oil combination burners include the features of both the gas burners and oil burners in a single unit. No burner modifications to change fuels--just a flip of a switch.
A5 000054
EXCLUSIVE COMBINATION HEAD
Exclusive design of burner firing head provides quiet, stable combustion of gas or oil at all inputs. The annular gas ports and vaned air diffuser assure complete mixing of gas and air for stable operation under wide variations of gas pressure and other conditions without objec tionable noise or pulsation
Swirling high velocity secondary air supply assures intimate mixing of fuel and air for clean, efficient firing.
MAXIMUM SAFETY
Dual automatic main gas valves provide added pro tection against valve leakage. Dual high limit controls.
low water cut-off and safety relief valves provide added protection against, excessive temperature or pressure and low water conditions. Boiler passages are purged of possible accumulation of combustible gases both before and after each firing cycle. An electronic flame safeguard continuously monitors pilot and main flame combustion sequence.
CONTROL CABINET
Electronic flame safeguard and programming system; switching relays; necessary magnetic starters, numbered terminal strips; indicating lights for major operations and fuel selector switch--all are mounted and wired in a heavy gauge steel, dust proof control cabinet. Wiring is ready for connection to source of power.
MODEL DESIGNATION CHART
Construction Design Output Rating
fue|
r l w t_t
T_JT
Desiin Pressure-low Pressure Q-1
High Pressure - H
Healing Medium-Water (*W^ Steam 5
Uml Output-Gross horsepower rating desurvate
5 Grade of Oil--Nr Alomiiing Burnet Number el U.S. Com! Std. Gride
Oil Firing--*11 Grides of Oil 0 Git fi tint--*11 hoe* f Cm -^G^
EXAMPLE IW-700-G05 is standard low pressure hot water 200 horsepower generator equipped for combination gas and No. 5 oil firing.
45 000065
7
KEWANEE*
Standard Equipment j Optional Equipment
ALL UNITS
]. ASME Cod* Boiler 2. Three-pass Scotch Boiler Design with Water Beck
3. Tull length Skid Type But 4. Gaj-Tight Construction
5. Pyrex Observation Ports (front l rear j
6. Access Opening (front C rear) 7. Boiler ExpandtdJiiebeTTJ&wlJ)ail^200;254'-Units250-750) 8. Top Vent (Unitf60-7M); Bear Vent (UnftFSO^Oi
9. Metal Jacket kith Mineral Fiber Insulation
10. lifting loops 11. Eiplosion Relief Obet^*
1 J
1. Flue Gas Temperature Gauge
2. Other Than Standard Voltages 3. Circuit Breaker
4. Alarm Bell 5. Instantaneous or Tank Type Water Coils
(low Pressure Units) 6. Controls tor FM 7. Controls for FIA 8. One-Year Service Period
12. Forced Draft Burner Assembly---------------- --
13. Operating High limit Control
14. Safety High limit Control
15. Firing Sequence: On-Off (Units 20-50) High-low-Ott (Units 60-80) Modulating (Units 100-750)
16. Modutrol Motor to Control Air-Fuel Supply (Units 60-750)
17. Control Voltage--115 v,, 60 cy,, I ph. (Includes Reduced Voltage Transformer Where Required)
18. Control Cabinet including: Electronic Flame Safeguard and Programming Control; Control Circuit Fuse; Control Circuit Transformer (Units 40-750); Control Circuit Switch; Burner Switch; DC Voltmeter or Microammeter (Units 60-750); Manual Potentiometer (Modulating Unit! Only s; Indicating Lights; Numbered Terminal Strip; Color Coded Wiring; Engraved Name Plates; and Necessary Relays and Magnetic Starters
19. Listed Standard and Selected Optional Equipment Mounted, Piped. Wired, Ready for Field Connection to Fuel, Water, Steam and Electricity. (Exceptions: Items shipped separately lo prevent shipping damage.)
20. Factory Fire-Test
21. Starting Service (Startup and 90 days service)
STEAM UNITS
1. No. 157 Combination Water Column, low Water Cut-Off, and Pump Control
.2 Safety Valves
3. Steam Gauge
4. Water Glass Gauge and Try Cocks
5. Manhole (Units 80-750) 6. Quick-Opening and Slow-Opening Blow-Off Valves (High Pressure Units)
7. Drain Valve (low Pressure Units>
1. No. 193 Combination Water Column, low Water Cul-Oft, Pump Con trol end Alarm Switch
2. NO. 51-2 Combination Low Water Cut-ON, Water Feeder and Alarm Switch (low Prtssurt Units)
3. Second low Water Cut-ON
4. Injector (High Pressure Units)
5. Higher than Standard Steam Working Pressure -Units 60-750i
1. No. 63 low Water Cut-Off
2. Relief Valves
3. Pressure Gauge
4. Thermometer
5. Drain Valve
HOT WATER UNITS
1. No. 51-2 Combinilion Low Water Cut-ON, Water Feeder and Alarm Switch
2. Second Low Water Cut-Off 3. Higher than Standard Water Working Pressure (Units 60-750
GAS UNITS 20-50
1. Multiple-Jet Flame Retention Type Gis Burner
.2 Ul Gas Control Group including; Automatic Operating Gas Valve, Auto
matic Safety Gas Valve, Gas Pressure Regulator, Gas Cock, Gas Pressure Gauge
3. Gas-Electric Ignition Assembly
4. Flame Rod Flame Detector
1. High-Low-OH Firing Sequence (Units 40-50) 2. Modulating Firing Sequence (Units 40-50 > 3. lead Sulphide Flame Detector 4. Gas Controls for Other Than Standard Pressures 5. Ges Controls for Local U'ility Requirements
5. On-Ofl Firing Sequence
6. Air Flow Salely Switch
,050 00 o-5 6
20-750 Blip
Standard Equipment
Optional Eequipment
GAS UNITii 60-750
1. Annular Port flame Retention Type Gat Burner
2. Ul Gat Control Group including: Automatic Motorired Gat Valve, Auto matic Safely Gat Valve. Gat Pressure Regulator, Gat Volume Control Valve with Adjustable Cam Operator; Lubricated Plug Gat Cock, Gat Pretsure Gauge
3. Gas-Electric Ignition Assembly
1. Modulating Firing Sequence (Units SO-SO) 2. Gas Controls for Other Than Standard Pressures 3. Cat Controls for Local Utility Requirements
4. Lead Sulphide Flame Detector
5. Air Flow Safety Switch
6. Firing Sequence: High-Low-OII with Low Fire Start (Units 60-80. Modulating with Low Fiye Start (Units 100-750)
PRESSURE ATOMIZING OIL UNITS 20-50
1. Mechanical Pressure Atomizing Oil Burner for No. 2 Oil 2. Two Stage Oil Pump Assembly Oirect-coupled to Burner Motor 3. Oil Nozzle (Dual on 40-501 4. Oil Solenoid Valve
1. High-Low-ON firing Sequence (Units 40-50; 2. Modulating Firing Sequence i Units 40-501 3. Lead Sulphide Flame Detector
5. Direct Spark Electric Ignition Assembly
6. Photocell Flame Detector
7. Firing Sequence: On-Off with Fixed Fire (Units 20-30) On-Off with Low Fire Start (Units 40-50)
1 Oil Filter (not mounted1
PRESSURE ATOMIZING OIL UNITS 60-150
1. Mechanical Pressure Atomizing Oil Burner for No. 2 Oil 2. Two Stage Oil Pump Assembly Mounted on Boiler Skid 3. Variable Flow Oil Nozzle
1. Modulating Firing Sequence (Units 60-801 2. Oil-Electric Ignition Assembly
4. Oil Solenoid Valve 5. Oil Metering Valve 6. Gas-Electric Ignition Assembly
7. Lead Sulphide Flame Detector 8. Air Flow Safety Switch
9. Firing Sequence: High-Low-Off with Low Fire Start (Units 60-801 Modulating with Low Fire Start (Units I00-I50i
ID. Oil Filter mot mounted;
AIR ATOMIZING OIL UNITS 60-750
1. low Pressure Air Atomizing Oil Burner for No. 6 and Lighter Oil
2. Oil Pump Assembly Mounted on Boiler Skid. For Constant Not Oil Circu lation (Ns. 5 16 Oil i or Intermittent Operation (No. 2 6 4 Oih
3. Air Unit Consisting of: Air Compressor: Air Pressure Regulating Valve; Motor; Inlet Air Filter; Air Proving Safety Switch; Air Pressure Gauge;
4. Air-Oil Nozzle
1. Modulating Firing Sequence (Units 60-80; 2. Oil-Electric Ignition Assembly 3. Remote Circulating Oil Pump
5. Oil Solenoid Valve
6. Oil Metering Valve with Adjustable Cam Operator
7. Gas-Electric Ignition Assembly
8 Lead Sulphide Flame Detector 9. Air Flow Safety Switch.
10. Firing Sequence: High-Uw-Off with Low Fire Start (Units 60-80). Modulating with Low Fire Start (Units 100-750)
11. Thermostatically Controlled Electric Oil Heater (No. 4, 5 6 6 Oil).
12. Boiler Mounted Oil Heater (No. 6 Oil Units). Safety Type Below-Water-
Line Heater with Pump Control (Water Units); Steam Heater with Modulating Valve and Trap (Steam Units)
13. Oil Strainer (not mounted i
COMBINATION GAS-OIL UNITS
1. Manual fuel Changeover Switch in Conlrol Cabinet
ff5 000057
9
KEWANEE SCOTCH GENERATOR
DIMENSIONAL DRAWINGS
60 HP thru 750 HP
fiS 00005S
typical
'O-EJSTER-A.TOPl--------------SPECIFICATIONS
The contractor shall furnish and instill--------------Model No.--------------Kewanee Scotch Coneritsr (i) lor (No. (7) (4) 0) (6) oil), (gas), or (conbination gas-No. (2) (4) ($) 0) H) firing. Tho wits ski* bo ol threepaa scotch design with water-cooled rttr and two posses oI firetubes, and shall bo
constructed in octsrdMco with the A5M Code lor (IS lbs. stum) (JO lbs.
water) (ISO lbs. steam).
Tho unit(s) shall havo a gres output rstirtg el net ka thao--(MBh) (Bhp).
A refractory linad accaa openinf wit* pyres observation port shal bo provided to permit entry into the rear combustion chamber. Access to hibo shoots and firetubes lor inspection or eleanini shad bo provided without disconnecting any luel piping or electrical wiring. Unit shall bo el gas-tight construction throughout Hue doors shad bo gasketed and lined with insulating refractory.
Units shall be provided with lifting loops and factory installed enameled steel jacket with mineral liber insulation.
All tubes shall be set with roller expander al each end. No welding of tubes to the tube sheets nor use of refractory baffling to piovidt the second or third pass will be permitted.
Units shall be assembled and wired, with burner, controls, trim, and skid type base installed tl Ihe factory.
Fuel burning equipment shall he lotted draft type: Factory assembled, wired, mounted, end tested. The entire unit shall bur the Underwriters' Laboratories label and shall be ready (or field connection to power and fuel supply. Equip ment shall include forced draft Ian with air damper; dual controls (limit and operating); flame sensing device; snd control cabinet containing electronic llame safeguard and programmer, control circuit switch, necesury switching relays, indicating lights foe major operations, numbered terminal strip, colotcoded wiring and engraved nameplates.
All motors shall be for........rolls......... ..cycle.phase operation. Controls shall be US volt, 60 cycle, single phase. Magnetic motor starters with thermal over load protection and a step-down control circuit transformer shall be pro vided in the control cabinet when other than 115 rolt motors are specified.
Fuel burning equipment shaft be set and adjusted by a factory-authorized representative to burn........... .. G.P.H. of No. (7) (4) 0) (6) oil (and) (or) ..................C.F.H. of.... ...........Blu/cu. ft. (natural) (manufactured) (U P.) gas having a............... sp. gr. with__________ inches W.C. pressure it inlet of burner manual gas cock. Unit efficiency, based on flue gas analysis, shall be not less than 80%.
AW: Spied] jot tltintdt if ovtr 2.500 ft ttontuknt
Owner's representative shall be present to receive instructions in care and maintenance of Ihe unit at the time it is started up by the service representative. Contractor shall provide a free service period of 90 days after startup.
AW Select ippheith puiftipit ktbw tecotHet to hut inimit tile. Tin lollowtn] ecchtm to UL ttooitememt Spied] Miaul email d fU u fU muni, ot nil/tct to tpteul fora/ utdtt] rtioiremeots.
FOR GAS UNITS 20-50
Gas burner shall be ol the multiple-jet flame retention type including i main gar control group consisting of an automatic operating gas valve, automatic safely gas valve, gas pressure regulator and gas cock; gas-electric ignition assembly consisting ol a 6.000 rolt ignition transformer, automatic gas valve, gas pressure regulator and gas cock; air-flow safety switch; llame rod flame detector; and all necessary controls lor "on-olf" type ol operation.
FOR GAS UNITS 60-750
Gas burner shall be of the annular port flame retention type mefuding a main gas control group consisting o4 an automatic motorized (u valve, automatic safely gas valve, gas volume control valve with adjustable cam operator, gas pressure regulator, gas gauge, and gas cock: gas-electric ignition assembly consisting ol a pitot burner, 6,000 ro* ignition transformer, automatic gas valve, gas pressure regulator, and gis cock; air (tow safety twitch; lead sulphide name detector; low fire interlock; and all necesury controls snd hnkage for (modu lated) (two-position) firing with proved tow fire start Fuel-air control shall provide (modulated) (two-position) regulation of Ihe air damper and the gas volume control valve by means ot a modutrol motor.
FOR PRESSURE ATOMIZING OIL UMTS 20-50
Oil burner shall be of Ihe mechanical pressure itomizing type for No. 7 oil wiih a two-stage oil pump direcl connected to the blower motor. Burner shall include oil atomizing nozzles; oil solenoid valve; 10.000 volt ignition transformei; photocell llame delector; snd ail necesury controls lor "on-oll" type ol operation.
FOR PRESSURE ATOMIZING OIL UNITS 60-150
Oil burner shall be of the mechanical pressure Itomizing type lot No. 2 oil with a two-stage oil pump assembly mounted on the boiler skid. Burner shall include oil atomizing nozzle; oil solenoid valve: oil control valve; gas-electric ignition assembly with pilot burner. 6.000 rolt ignition transformer, automatic gn valve, gas pressure regulator and gas cock; sir flow ulely switch; lead sulphide flame detector; low fire infertock; and all necesury controls and linkage lor (modulated) (two-position) (inng with proved tow lire start. Fuelair control shall provide (modulated) (two-position) regulation ol the air damper and the oil control valve by means ol a modutrol motor.
FOR AIR ATOMIZING OIL UNITS 60-750
Oil burner shall be ol Ihe air atomizing type tor No. (2) (4) (5) (6) oil with an
air unit cansistini of air compressor, air pressure regulating valve, motor inlet sir fitter, air proving safety switch, and air gauge. An oil pump assembly with putts, sttimet ud tthef vafvt shall be mounted on the boiler shid. Burner shall mdbde air-oil atomizing nozzle; oil solenoid valve; oil metering valve with adjustable am operator; thermostatically controlled electric oil heater (oan hi hi. 2 mil); gas-electric ignition assembly consisting of a pilot burner, 6009 rolt ignition transformer, automatic gas valve, gas pressure regulator and gas cock; air flow stfefy switch; lead sulphide flame detector; low fire interlock; and all necessary controls and linkages (modulated) (two-position) firing with prorod low fir* start Fuel-air control shad provide (modulatedj (two-position) regula tion ot the sir damper and the oil control valve by means of a modutrol nutor. (Oil turMg equipment for No. S oil shall induM factory mounted and piped (baffled u-lube oil preheater) (safety type oil preheater) complete with neces sary temperature control for (betow-water fine water operation) (slum operation). A control shal) be provided tor No. 5 and 6 oil to permit continuous operation of oil pump and oil prehulers when burner is not running).
hott: Spied] til tut kmiof tjtwn to Pt aid.
FOR COMBINATION GAS-PRESSURE ATOMIZING OIL UNITS 20-50
Gas-oil burner shall consist of a combination multiple-jet flame retention type gas burner and mechanical pressure atomizing oil burner tor No. 2 oil including all necessary controls (or "on-olf" type of operation. Gas controls shall include a main gas control group consisting ol an automatic operating gas valve, auto matic safety gas valve, gas pressure regulator and gas cock; gas-electric ignition assembly consisting of s 6,000 volt ignition transformer, automatic gas vilve. gas pressure regulator and gas cock; air (low safety switch; and llame rod llame detector. Oil controls shall include a two-stage oil pump direct connected to the Mower motor; oil atomizing nozzles; oil solenoid valve; 10,000 volt ignition transformer; and photocell (lame detector. Changeover from one fuel to the
other shall be accomplished by means ol s manual fuel selector switch in the burner-mounted control cabinet No changes in linkage, burner position, or mechanical adjustment shall be necesury when changing fuels. The fuel selector switch shad provide, through the combustion control relay, proper
ignition timing lor the fuel being burned.
FOR COMBINATION GAS-PRESSURE ATOMIZING OIL UNITS 60-150
Gas-o<l burner shall consist of a combination annular port flame retention type gas burner snd mechanical pressure atomizing oil burner for No. 2 oil including all necesury controls for (modulated) (two-position) type Of operation with proved low fire start Gas controls shall include a main gas control group con sisting of an automatic motorized ps valve, an automatic ufety gas valve, gas volume control valve with adjustable am operator, gas pressure regulator,
gas pup, and gu cock. Oil controls shall include a two-stage oil pump assem bly; oil atomizing nozzle; oil solenoid valve; oil control valve. Controls for both fuels shah indude a toad sulphide flame detector; air flow ufety switch; tow fire interlock; snd gas-electric ignition assembly consisting of a pilot burner, 6000 voft igmTion transformer, automatic gas valve, gas pressure regulator and gas cock. Fuel-air control shall provide (modulated) (two-position) regulation ol the air damper, the gas volume control valve and the oil control valve by means of a modutrol motor. Chargeovet from one fuel to the other shall be accomplished by means of a manual fuel selector switch in the control cabinet No changes in hnkage, burner position, or mechanical adjustment shall be necessary when changing fuels. The luel selector switch shall provide, through the combustion control relay, proper ignition timing (or Ihe fuel being burned.
FOR COMBINATION GAS-AIR ATOMIZING OIL UNITS 60-750
Gas-oil burner shall consist of a combination annular port llame retention type
gas burner and air atomizing oil burner lor No. (2) (4) (5) (6) oil with ill
necessary controls lor (modulated) (two-position) type ot operation with
proved tow fire start Gas controls shall include a main gas control group con
sisting of an automatic motorized gas valve, automatic ufety gis valve, gis
volume control valve with adjustable am operator, gas preuure regulator,
gas gaup and gas cock. Oil controls shall include an air unit consisting si an nr
compressor, air pressure regulating valve, motor, inlet air litter, check valve,
sir proving ulety switch, air gaup; an oil pump assembly and relief valve
mounted os the boiler skid; sir-oil atomizing nozzle; oil solenoid valve; oil
metering valve with adjustable am operator; thermostatically controlled
electric oil heater fomi lot ho. 2 pit). (Oil burning equipment lor No. 6 oil shall
include factory mounted and piped (baffled u-tube oil preheaten (safely type
oil preheated complete with necesury temperature control lor (below-witer
line water operation) i steam operalion). A control shall be provided lot No. S
and 6 oil to permit continuous operation of separate oil pomp mi oil preheale rs
when burner is not running', hoti: Sptttlj oil rani Aeanno system to Pi out Con
trols for both fuels shall include lead sulphide flame detector; air How ulety
switch; low lire interlock; and gas-electric ignition assembly consisting of a
pilot burner, 6000 voft ignition trsnslormer, automatic ps valve, gas pressure
regulator and gas cock. Fuel-air conlrol shall provide fmoduialedi (two posi-
lion regulation of Ihe air damper. Ihe gas volume conlrol valve, and Ihe oil
metering valve by means of a modutrol motor. Changeover from one luel to Ihe
ether shall be accomplished by means ol a manual luel selector switch in the
control cabineL No chanps in linkap. burner position, or mechanical adjust
ment shat be necesury when changing fuels. The fuel selector switch shall
provide, through the combustion control reliyjrooer ignition liming tor Ihe
fuel being burned
Q()0 0&9
12
The Hat Transfer Products Department of AmericanStandard provides one dependable source for all of your heat transfer needs and requirements. Industry leadership is strived for and maintained through the utilization of time-tested equipment design, research facilities, coor dinated engineering service, years of practical experience a (. and aftar-the-sale responsibility. Product specialists ari always ready to assist you regardless of the simplicity or complexity of your heat transfer requirements.
AMERICAN STANDARD
rr. I
Join the ranks of some of the world's most discriminating buyers who have been satisfied with American-Standard heat exchanger and boiler products. You are certain to find similar satisfaction whether you're a user, contractor, or specifier. Also, you can benefit from our experience as countless others have -- 100 years of boiler know-how and 50 years of progress in the heat exchanger industry.
^AMERICAN l J4STANDARD
HEAT TRANSFER PRODUCTS DEPT. Uecortiv* Office. 0*1roil. Michifin 483#
iwllotin 96-12 96A SM 6~68 Bl