Document mvrrO5vV2E6XGR4QdpLppRqd
' .... . _
_
WGK ANALYTICAL RESEARCH AND DEVELOPMENT REPORT
OTHER LOCATIONS
GENERAL OFFICE
, ...... . N No. 2457, May 16, 1974
- W. G. KRUMMRICH PLANT
T. Bell - Anniston T. Brown - Anniston
J. R. Savage - B2SL
(Copies sent to R.Munch, W.R.Richard - G.O. and V.R. Haupt - Anniston 5/28/74)
W. C.
A. E. K. E. G. G. A. J. R. File
Engmanr^
Leisy Boucher Johnson Hippe Kuster
'
TITLE*
Dept. '246 -Aroclors. Biphenyl Quality
PERSONNELS
L. H. Horcher (H. J. Horner)
PROBLEMS
Develop semi-routine method for determining methyl biphenyls in biphenyl. Analyze samples of biphenyl made from 'good' and high toluene benzene.
JUSTIFICATIONS
The.quality of benzene used for biphenyl production at Anniston may be of lower quality and could increase the methyl biphenyl level in the biphenyl. Methyl biphenyls are thought to affect stability of the Aroclors.
SUMMARY:
We developed a procedure using a Varian Model 1440 FID GC to analyze the biphenyl for the various impurities. We can detect impurities down to' 10 "ppm without any serious problems. Biphenyl samples produced with 'good' benzene and material made during the Anniston 'Toluene Test' (500 ppm) run were analyzed. Results of these samples, as well as chromatograms of a standard containing the probable impurities in biphenyl and of a typical sample are attached. The biphenyl produced during the 'Toluene Test' showed an increase in the methyl biphenyl by 1.5 to 3.5 times that in normal production.
Ref. WGK Notebook 16380-16393. ' 18246-18260.
dy
H. Horcher
CONFIDENTIAL
DSW 310122
CK ITT
l . ...
This report is the property of Monsanto Company and the recipient is responsible for its safekeeping
ond disposition. It contains confidential information of Monsanto Company which must not be reproduced, revealed to unauthorised persons or sent outs ids the company without proper authorisation.
This report is to be retained in o secure file or destroyed.
STLCOPCB4070109
AR-D Report No. 2457
Page 2
May 16, 1974
Details
I. Background
Past work has indicated that high methyl biphenyl levels in biphenyl cause stability problems in Aroclors. Benzene shortages may force our Anniston Plant to use lower quality benzene (higher in toluenes). A procedure is necessary to determine methyl biphenyls and other pertinent impurities in biphenyl. Recently Anniston made a production run using benzene containing 500 ppm toluene. We have received two samples taken from their biphenyl receivers, as well as samples of two cars loaded from the storage tank containing some of the biphenyl made during this period. These samples and several reserve samples from past production are to be analyzed to determine the change if any, in methyl biphenyl levels.
II. Method Development
In January of 1972 we did some analytical work on biphenyl quality. Based on this work we set up an instrument with conditions similar to those used at that time. A standard containing the major impurities found at that time was made up to check and optimize instrumental conditions. Oven temperatures, flowrates, split ratios and sample concentrations were varied until we felt we had good resolution of the pertinent components. A shortened version of the original column combination was sufficient.
Since the analysis requires that we analyze only the minor components of a sample that is essentially 99+% biphenyl, we employed the internal standard technique. Normal C-12 was chosen as the internal standard since it elutes before the components of interest and is well clear .of the solvent tail. None of the reagents with the exception of specially purified napthalene and biphenyl were pure. The reagents were all assayed to enable us to prepare a reasonably accurate calibration standard. The area correction factors _vs_n C^2 f tiapthalene, 2-, 3-, and 4-methyl biphenyl were determined. A factor for 2,3 dimethylnapthalene was also determined and used for all the mono and dimethylnapthalenes. A standard containing the probable impurities in biphenyl was run and a chromatogram is attached.
* ._
HI. Analytical Work
The samples were taken up in benzene (solvent) containing 503 ppm n C12 (internal standard). The sample solvent concentration was 11 on a w/w basis. Four samples of biphenyl made during the last quarter of 1973, the two Anniston biphenyl receiver samples and the two cars loaded after the recent 'Toluene Test' run were analyzed.in this manner. The results and a typical chromatogram are attached.
DSW 310123
STLCOPCB4070110
AR-D Report No. 2457
Page 3
May 16, 1974
IV. Conclusions
In all the samples from the Toluene Test the methyl biphenyl levels were higher than that produced in the last quarter of 1973.
The receiver samples were more than 3.5 times higher and the car samples which were diluted by the good biphenyl in storage were up by 1.5 times.
The impurity labeled as Unknown (1) which we tentatively identified by retention time as diphenyl methane increased somewhat but the increase was not as significant as the methyl biphenyls.
We can analyze biphenyl for methyl biphenyl on a spot basis. The instrument and columns are not available on a daily routine basis. We also need to determine the area correction factors more rigorously if the procedure is to be used routinely.
L. H. Horcher dy
(1) This unknown tentatively identified by retention time as diphenyl methane.
DsW 310124 STLCOPCB4070111
AR-D Report No. 2457
Page 4
May 16, 1974
RESULTS
Biphenyl Quality, Last Quarter 1973
Lot No. Date
AC-168 11/5/73
AC-156 10/4/73
AC-183 GATX 94513 (2)
12/8/73
11/27/73
Napthalene Unknowns 2 Methyl Mapthalene 1 Methyl Napthalene
2 Methyl Biphenyl Unknown (1) Di Methyl Napthalenes 3 Methyl Biphenyl 4 Methyl Biphenyl Unknown (High Boilers) Total Impurities Total Methyl Biphenyls
39 ppm 36
-' 8 121 430 18 904 179 -
1735 1204
12 ppm 7
-4 -
84 394
--
474 63 78
1116 621
14 ppm 29
5 4 157 537 -
948 120
-
1814 1225
19 ppm 5 9
14 260 776
23 821 150
-
2077 1231
Biphenyl Quality - 'Toluene Test'
Lot No. Date
GATX 93194 GATX 94529 5/3/74 (2) 5/8/74 (2)
Anniston Receivers 4/19/74(2) 4/26/74
Napthalene Unknowns 2 Methyl Napthalene 1 Methyl Napthalene 2 Methyl Biphenyl Unknown (1) Di Methyl Napthalenes 3 Methyl Biphenyl 4 Methyl Biphenyl Unknown(High Boilers) Total Impurities Total Methyl Biphenyls
14 -
23 208 656
10 1364
249 62
2586 1821
ppm
10 ppm 4 -
29 211 792
5 1587
307 6
2951 2105
16 -
2 12 173 799
ppm
.
2623 554
*7 4184 3350
17 ppm 120
-
11 209 816
2599
545 -
4317 3353
(1) This unknown tentatively identified by retention time
- as diphenyl methane.
-
(2) These results are the average of duplicate runs.
DSW 310125
STLCOPCB4070112
f if
i
5 1 .1! 91 SI M U Z l l 01
Chromatogram of material made during Toluene test
shh *jni/ 2^
&
- *---- -
*%%
0t?&fi>yu
- MeTttA*r jAfgBiQ
M7
`
._ _ f
AR-D Report No-. 2457
Page 5
May 16, 1974 DSW 310126
STLCOPCB4070113