Document mqomzwZ4g6vM5RO6mmBLo4GBB

JUIIIU . '` Canada limited --^--.' ' J A Overing-------;--------------- rcoM TORONTO/ Ontario DATE subject October 5, 1971 SANTICIZER 711 RcrERENCE Monsanto Oakville TO J H Brydon - Montreal cc: D Press and the writer made a call to observe a trial on SANTICIZER 711 re GM's T9012, based on the results obtained by lab work in Oakville and St Louis,, J G Edmiston H F Dixon L D Presi J Lilly W Schalk M Medgessy R V Todd T Corpe G Moore R A Fenn A Curry J Overing G Bradley File - Chem Toront Montre St Loe Oakvil It . II II II Toront Montre These trials were conducted as in the report of Sept. 15/71/ with the exceptions listed below. 1. OPALON 670 resin was used instead of the 20 parts Esso 366/80 parts Esso 369. The reason was that Oakville has a lipping problem when using the 80/20 blend that they can rectify with OPALON 670. >v. 2. Temperatures on the drop mill were raised: Front Roll Raised 5F ,. Back Roll " ... 10F % ' Also, the offset roll on the calefl&er was raised 10F 3. Formulation containing S-711 contained no stearic acid. The S-1160 using new and old alfol 610 alcohol ran well. The extruder (from the mixing extruder) looked well plasticized and smooth/ not dry and gritty as mentioned in the previous report. Similarly/ the banks on the calender were smooth and fluid. The trial using S-711 (v.Tithout stearic acid) gave an excellent produc' as well, with no evidence of holes or comet tails. Again, the extrudate and feed mill stock appeared wet and fluid. No sticking was observed on the calenders, with the absence of stearic acid. It was noted that the Banbury drop time using S-1160 (new alcohol) was recorded at 2 minutes, 20 seconds + 5 SECONDS. With S-711 it was recorded at 2 minutes, 10 seconds*/- 5 seconds. * It appears that the utilization of a higher molecular weight resin (in both cases) allowed a more complete fusion to occur in the banbury; also, the absence of stearic acid in the S-711 formulation helped to gain a more fused product. .............. 2 DSW 587626 STLCOPCB4092962 To: J H.Brydon Re: S-711 2 Oct 5/71 RUNNING CONDITIONS D514E (S-711 without Stearic Acid) Set Actual D514F (S-1160 - New Alcohol) Set Actual Banbury Drop 310F 315F 310'f 315F Drop Mill Frront Roll 340 Back Roll 340 345 345 340 340 350 350 Extrudate 320 320 Feed Mill Front Roll Back Roll 325 . 320 335 330 325 320 330 330 Calender Offset Roll Top Roll Middle Roll . Bottom Roll 330 325 330 330 325 325 325 325 ?| 330 325 330 330 X 315 310 305 300 A run was made (10 batches) using the 1%0/20 blend of Esso Resin and S-711. This was identical to the formulation Oakville; had experienced hole problems with in production, except that no stea acid was added. The product manufactured showed no evidence of pin holes. Some sticking appeared on thecalenders during start-up, but this was cleared up when it was decided to add 0.15 parts of stearic acid. This small addition did not effect the quality of the fin ished product (no holes). This test did tend to conclude that the pin hole problem was a result of underfused stock, due to not enough shear being put into the product. Be removing the stearic acid, one was able to develop more work by the processing equipment.. _ JO/ema DSW 587627 STLCOPCB4092963