Document mqnan6KYNwvrv7qwzGYDZko14

Case: 43106-8 & subject Evaluation of the K^ Asbestos Screening Kit for QTC Use Bell Laboratories date. August 25, 1980 item j). Raioer C. P. Lichtenwainer MEMORANDUM FOR RECORD 4 4 Introduction Recently a method for the quick identification of asbestos incorporated Into a package called the "a Asbestos Test Kit" has been developed by a group working.at the National Institute For Occupational Safety and Health (NIOSH). The K^ Test Is a method for determining the presence of asbestos in samples of bulk material. Mr. David Rainer and Mr. Charles Lichtenwainer of the Bell Laboratories Environmental Health and Safety Department have conducted a study to evaluate the ease of use and reliability of the K^ Test as it applies to the needs of operating telephone companies. How the K^ Test Kit Works The K2 Test is a colorimetric test for magnesium (Mg +2 ) and Iron (Fe +2 ) and is not specific for asbestos. Magnesiuio^and iron are contained in all types of asbestos (Table 1). The Mg from chrysctile Is complex^ with p-nltrobenzene a^onaphthol and forms a blue color. The Fe from the aaphiboles is coaplexed with 1, 10-phenanthroline and forms a red color. A positive test is indicated by the formation of these colored complexes and indicates the possible presence2of asbestos. A positive test must be confirmed by means other than the K kit. Table 1: Classification of Asbestos TYFK swmnn Chrysctll* axpuibo.es Treaolitc Acclnollce Aachsptiylllee tao5iee Croctdnlttfr CCKPOSTTIOH CRYSTAL TRICIl*B 3Xg0*2Si02*2H2P eonoclintc 2C40-5XsO'851O2*H2O conocliaic 2CaO*4MgO-FeO-8Sl02-BjO f*cneclinic 7HgO-3StOH20 5.5Fe0.1.5EO*8SlC2*H2C orcForre-Vic mnorltnic Ha20- Ff203 3Tt0-3Si02-H20 conrclinic LLA 001651 2 The National Institute for Occupational Safety and Health (NIOSH), has reported chat in its test of 20 field samples, 52 samples or 745! were correctly identified by the Test. Eighteen samples, or 26%, gave false positive results. The lowest quantities of asbestos contained in the NIOSH samples were 3Z chrysotile and 1% amosite. Mi SCU ATuuwnwn 2 A "K Asbestos Test Kit" was purchased from Anatole J. Sipin Co., Inc. of New York, one of two manufacturers making the kit available to the public. The contents of the 1C kit was adapted wholesale from the NIOSH group and includes the exact NIOSH Issued directions (Appendix I). Six Insulation samples known to contain asbestos (5 chrysotile, 1 amphibole) and 2 prepared samples, one containing 1% by weight chrysotile and one containing 1% by weight amosite were tested using the KZ Kit. The instructions In the kit were followed directly (Appendix I). 2 On one occasion the K Kit was used in the field to try to determine the presence or absence of asbestos. Results The five samples known to contain chrysotile asbestos all gave a positive response to the magnesium test. All these samples contained more than 10% chrysotile. The results of the 1Z chrysotile by weight In a bulk sample were ambiguous because it could not be determined with certainty if a color change had occurred or not. A clear positive response was given for the 1% by weight amosite test. A clear positive response was also given for the amosite sample collected from the field. This sample contained more thaa 10% anosits. 2 The field trial for the K test was not successful. In this particular Instance, two operating coopany safety personnel who had used the kit under laboratory conditions used the kit in the field. Results of the three saoples tested were ambiguous and a color change could not be positively identified. An x-ray diffraction scan of the three samples shoved one contained about 10% chrysotile while two contained nc asbestos. Discussion Properly equiped Laboratory personnel familiar with chemicals and laboratory safety would probably not have too.nuch trouble using the KZ Kit. The instructions included with the K* Kit are not altogether clear but three trials were adequate to aquaint a trained laboratory technician with the cethods involved. LLA 001652 * - 3- The results of the 5 chrysotite tests performed were often very difficult to interpret. The main problem is that the magnesium reagent is purple and a positive test is indicated by a color change to blue. The aaphibole test was easier to interpret and an accurate positive identification was made at 1Z amosite by weight in a bulk sample. Results of the field testing of the K2 Kit were ambiguous. Some of the problems with field use of the Kit involve the use of items not always available in a field situation, such as: 1. a good light source is necessary, 2. running water is needed, 3. an adequate supply of distilled water is necessary, 4. counter space is needed, and 5. protective equipment such as goggles and impervious gloves and an apron must be worn. 2 No safety data sheets were included with the K Kit evaluated. ^ Another manufacturer is supplying safety data sheets with the & kit. Some of the chemicals included in the Kit are extremely dangerous and the following warning data is suggested for inclusion in kits distributed to OTC personnel. Sodium Hydroxide (NaOH) Corrosive to body tissue; mists and vapors may cause burns, eye hazard. Phosphoric Acid (HjPO^) Causes irritation to upper respiratory tract; contact may cause burns to the skin. Hydrochloric Acid (BC1) e.Causes irritation to skin, eyes and mucous membranes via oral and inhalation routes. b. Will react with water or steam to produce toxic and corrosive fumes. Hydrofluoric Acid (HF) a. Causes marked irritation of the eyes, nose and thro3t; acute lung damage; cumulative bone damage. b. Unlike HCL, HF is readily absorbed by the skin and cay cause severe corrosive effects and systemic effects. LLA 001653 # L Chemical goggles which completely cover the eyes should be worn as well as rubber gloves when handling these materials. Clothing should be protected by a plastic apron. Conclusions y The K kit is not recommended for use by OTC employees unless they are adequately trained in the use of the kit and laboratory safety. The hazards associated with improper use of the chemicals in the ti kit are severe and the possibility of misinterpretation of results are high by untrained personnel. when used in the laboratory by trained personnel using appropriate safety precautions the a kit was relatively easy to use although results of the chrystolite test were sometimes very difficult to interpret. The test for the amphiboles was accurate and easy to interpret even when concentrations were less than 10Z by weight. D. Rainer no UH-8691-,,,rcm CPL C. P. Lichtenwalner Cony to C.` Bernard - AT&T-l.L L. Williams Bill Benoit - Pacific Telephone R L. Beach - AT&T >. J. DeCapua J. H. Degen R. W. Stone, K.D. W. J. Schreibeis G. K. Wilke fling LLA 001654 RrF ' 1T-NCES 2 Kupel, Richard 1979. K Test ror Screening Asbestos Paper presented at Symposium on Asbestos tdertipi.acion and Measurement. Des Plaines IL. Available from: American Conference of Governmental Industrial Hygienists, Inc. P.0. Box 1937 Cincinnati, Ohio 45201. * LLA 001655 Appendix 1 Iron Test 1. To determine the presence of an iron interference, add a few drops cf Iron Reagent directly to the sample, If a reddish color appears, wash the sample before the test with acetic acid and sulfuric acid according to the procedure described below. Samples containing fiberglass or mineral wool are also washed with the acids. For greatest reliability it is best to perform the acid wash routinely. Acid Wash a. Place a small portion of the sample, about the size of a large pea, in a clean plastic beaker. b. Add 5 drops of acetic acid to the sample with a clean dropping pipet. c. Also add 5 drops of sulfuric acid to the sample with a clean dropping pipet. d. Mix the sample and acids well with a clean glass rod. Let the mixture stand for 5 minutes. e. Place a polyvinyl chloride membrane filter (iron test) on the perforated face of the disassembled Swinnex filter holder f. Empty the contents of the plastic beaker onto the membrane filter. g. Add the gasket and assemble the Swinnex filter holder. h. Fill a clean plastic syringe with 10 milliliters of de-ionized water, attach the syringe to the filter holder and empty the syringe to wash the filter. i. Repeat the wash 4 times for a total of SO ml. of water. j. Transfer the sample from the filter to the test plate and proceed with the iron test (alternatively, the entire menbrane filter can be transferred}. 2. Add a drop of Hydrofluoric Acid (HF) solution from a clean plastic pipet to the sample ana bust wexi. 3. Add S drops of Iron Reagent (Fe Reagent) and observe the development of a reddish color. 4. A. reddish color indicates Char assssccs (amosite or crocidol ice) rcay be present}. 5. Samples giving a positive iron indication (i.e. reddish color) may be sent to a laboratory for confirmation. C. Notes If both parts of the test give negative responses,, there is a low probability that any asbestos is present. Once the presence of nagnesiun and/or iron is indicated, further analysis, if needed, is done in the laboratory to confirm, identify the type, and quantitate the percentage oE asbestos. LLA 001656 Magnesium Test 1. To determine the presence of magnesium interferen.ee, add a few drops of Magnesium Reagent directly to tha sample with a clean (new or washed) dropping pipet. If a blue color appears wash the sample with glycerin, as described below, before the teat. Any sample known to contain plaster is also washed with glycerin. For greatest reliability it is best to J perform the glycerin wash routinely. ' Glycerin Wash a. Place a small portion of the sample, about the size of a large pea, in a clean plastic beaker. b. Add 5 drops of glycerin to the sample with a clean dropping pipet and mix well with a clean glass rod. c. Rinse the glass rod with a small amount of water into the beaker. d. Place a cellulose ester membrane filter (magnesium test) on the perforated face of the disassembled Swinnex filter holder. e. Empty the contents of the plastic beaker onto the membrane filter. f. Add the gasket and assemble the Swinnex filter holder. g. Fill a clean plastic syringe with 10 milliliters de-ionized water, attach the syringe to the filter holder and empty the syringe to wash the filter. h. Repeat the wash 4 times for a total of 50ml of water. i. Transfer the sample from the filter to the test plate and proceed with the Magnesium Test (alternatively, the entire membrane filter can be transferred). 2. Add a drop of Phosphoric Acid (H3PO4) from a clean plastic pipet to the sample and mix well by grinding the sample with a clean glass rod. 3. Add 2 drops of ION Sodium Hydroxide (ION NaOK) from a clean pipet to the ^ sample and mix well. 4. Add 5 drops of Magnesium Reagent (Mg Reagent) from a clean pipet to the sac-pie and stir briefly. Sore any color change. 5. Add 5 drops of Magnesium Reagent to the sample, as in (4) above, and observe the final color. 6. A blue color indicates the asbestos (chrysotile) ray be present. 7. Samples giving a positibe magnesium indication (i.e. blue color) may be sent to a laboratory for confirmation. If the magnesium tost is negative, the sample must be tested for iron. LLA 001657