Document mqaB315600d6LoOEdjD8mombd

776_________ , Chapter 46" - _______.________ 1945 Guide per gallon of water heated 100 F. The value of 4 allows for transmission losses, etc. There are two ways in common use of estimating the hot water require ments of a building; first, by the number of people and second, by the number of plumbing fixtures installed. Where the'number of people to be served is known or can be reasonably estimated, the data in Table 1 may be used. . Example 1. From Table 1, a residence housing five people would have a daily requirement of 5 X 40 = 200 gal per day, and a maximum hourly demand of 200 X = 28.5 gal. The heater should have a storage capacity of 200 X H *= 40 gal and a heating capacity of 200 X M -- 28-5 gal per hour. - . The conditions given in Example 1 may be cited as average. If is possible to vary the storage and heating capacity by increasing and Table 1; Estimated Hot Water Demand per Person for Various Types of Buildings Type of Bududing Res., apts., hotels, etc. Office buildings Factory buildings Restaurants $0.50 meals $1.00 meals $1.50 meals Restaurants 3 meals per day Restaurants 1 meal per day Hot Water Required at 140 F Max. Hourly Demand in Relation to Day's Use Duration of Peak Load Hours Storage Capacity in Relation to Day's Use Heating Capacity in Relation to Day's Use x40 gal per person per day 4 H -K 2 gal per person per day 2X X a5 gal per person per day . 1% X 1.5 gal per meal 2.5 gal per meal 4.5 gal per meal Ko Ko Ho 8 X Ko .H 2 % X decreasing one over the other. Such a condition is. illustrated in Ex ample 2. Example B. Assume an apartment house housing 200 people. From the data in Table 1: Daily requirements = 200 X 40 = 8000 gal. Maximum hours demand 8000 X H = 1140 gal. Duration of peak load = 4 hours. Water required for 4-hour peak = 4 X 1140 = 4560. If a 1000 gal storage tank is used, hot water available from the tank = 1000 X 0.75 = 750. Water to be heated in 4 hours = 4560 -- 750 = 3710 gal. Heating capacity per hour = = 930 gal. If instead of a 1000 gal tank, a 2500 gal tank had been installed, the required heating capacity per ,hour wou,ldj.be 4--56:--0--------(^2-5--0--0----X----0--.-7--5- )- = c67_1, ga,l. Table 2 may be used to determine the size of water heating equipment from the number of fixtures. To obtain the probable maximum demand multiply the total quantity for the fixtures by the Demand Factor in line 11. The heater or coil should have a water heating capacity equal ___Hot Water Supply----------- ------777' to this probable maximum demand. The storage tank should have a capacity equal to the probable maximum demand multiplied by the storage capacity factor in line 12. Example 8 will illustrate the procedure.1 Example 3. Determination of heater and storage tank size for an apartment building from number of fixtures. 60 lavatories........... 30 bath tubs______ 30 showers...... 1____ 60 kitchen sinks.__ 15 laundry tubs----- X 2 = 120 gal per hour X 20 = 600 gal per hour X 75 = 2250 gal per hour X 10 = 600 gal per hour X 20 = 300 gal per hour Possible maximum demand__ ........ ..... .................................... = 3870 gal per hour Probable maximum demand................................. = 3870 X 0.30 = 1161 gal per hour Heater or coil capacity.... ........................................................... =1161 gal per hour Storage tank capacity............... ............................... = 1161 X 1.25 = 1450 gal. Table 2. Hot Water Demand per Fixture for Various Types of Buildings Gallons of water per hour per fixture, calculated at a final temperature of H0 F ApartMEET House Club Gth- nasiuh Hodpetal Hotel Indus trial Plant Omra Build ing Private Resi School dence YM. CJ>. 1. Basins, private lavatory-- 2 2 2 2 2 2 2 2. Basina, public Iavatory___ 4 6 8 6 8 12 6 I ffalhtnhn 4. Dishwashers 20 20 30 20 20 30 -- 15 50-150 50-150 50-200 20-100 5. Foot basins.:.. 3 .3 12 3 3 12 .... 6. Kitchen sink... ....... _... . 10 20 20 20 20 7. Laundry, stationary tube.__ 20 28 .... 28 28 8. Pantrv sink 6 10 10 10 _. 9. Showers ... 75 150 225 75 75 225 10. Sion Rink 20 20 20 30 20 15 11. Demand factor 0.30 0.30 0.40 0.25 0.25 0.40 0.30 12. Storage capacity factor* __ 1.25 0.90 LOO 0.60 0.80 1.00 2.00 22 2 15 8 20 30 15 20-100 20-100 3 3 12 10 10 20 20 28 5 10 10- 75 225 225 15 20 20 0.30 0.40 0.40 6.70 1.00 1.00 .Ratio of storage tank capacity to probable maximum demand per hour. METHODS OF HEATING WATER Hot water may be heated either.by the direct combustion of fuel, by an intermediate carrier such as steam or hot water, or by electrically heated surfaces. The simplest method is to have the fire on one side of a metalt barrier and water on the other. In such a method if the water surfaces' of heat transfer are small, and if the water carries a heavy proportion of precipitable salts, the water passages may soon clog and then bum out. A familiar example of such trouble is the water back of the firebox in the kitchen stove or the pipe coil inserted into the firebox of a warm air furnace or small boiler. The . critical water temperature at which the lime, magnesia, etc. collect on hot surfaces, varies with the character and proportions of the solids, but generally such deposits are not a serious trouble with water temperatures lower than 140 F. Coal-burning direct-fired water heaters may be constructed of cored cast-iron sections or of steel. In some cases the external appearance of