Document mqDjX6Jp6LgDYywpJqZ7K80md
A .I.A . FILE NO. 2 3 -L N .A.H .B. IN D E X NO . 3 4 0
Improved Best all Firestop is a Qypsum wallboard reinforced with specific amounts of in combustible ghss fibers and unexpanded vermiculite. Under heat this results in a thermal stabilized core which provides increased fire protection, blow, through greater glass fiber reinforcement, Firestop's fire resistance has been further increased, as shown by the chart on the back of this sheet. The higher glass fiber content also gives increased strength and better nailing qualities.
Bestwall Firestop in various assemblies carries ratings of 45 minutes to 3 hours fire resistance. These ratings meet Building Code requirements for interior wall and ceiling construction in buildings of all types, from wood frame to highly incombustible, and for various occupan cies of residential, public, and commercial character.
Extra glass fiber content gives greater protection, additional flexural strength to minimize breakage in handling and installation, and better nailing qualities Various assemblies provide 45 minutes to 3 hour fire protection No joint treatment of any kind is required to obtain fire resist nt ratings One of the lowest cost 2 hour fire resistive incombustible floor and ceiling assem blies available Large, lightweight panels handle easily Official Fire Hazard Classification by U.L. 10-15 Flame-spread U.L. Label Service Symbol appears on twin mounting tape binding each bundle of two pieces Vi" or %" "Besrwall Firestop Type 'X'" is marked frequently along the center so that Firestop is easy to identify when in place.
Bestwall Firestop is recommended where fire resistance is desired, and/or for Building Code Requirements of 45 minutes to 3 hours for interior wall and ceiling con struction in residential, commercial and public buildings.
W,Thickness:
%"
Length: 6' to 16' (in even feet)
Width: 4' (2' on order)
Edges: Tapered or Square (Tongue and Groove backer only)
Packaging: Twin Mounted, end taped
Application: Horizontal application is recommended
for new improved Firestop. Start application in upper corner, working across and down. Either cut openings
out of full panels or plan joints to occur on the studs nearest the center of the openings. No joint treatment
or further surface treatment of any kind is required.
Nails
Wallboard Nail Spacings
Thickness
Walls Ceilings
5d--1%" long-
Vz" 5d Cooler 7"
15/64" head--13Vz ga.
6d--1%" long14" head--13 ga.
%" 6d Cooler 7"
Drywall Screws
Vi" or %" Length 12" Varies
6" 6"
SGP 0025281
(over)
A.I.A. FILE NO. 2 3 -L N .A.H .B. IN D EX N O . 3 4 0
GP-65260E
/GEORGIA-PACIFIC BESTWALlJ GYPSUM DIVISION PAOU, PENNSYLVANIA 1S301
GP-65260E
FIRE RESISTANCE RATINGS POSSIBLE WITH BESTWALL FIRESTOP
CONSTRUCTION
PARTITIONS: 2' x 4'Wood Studs: 16" O.C. Load bearing except when noted "N''.
Nailable Steel Stud: Load 8earmg 3%" 24" O.C.
Non Load Bearing \%" 24'O.C. 3 V 24' O.C. 2 V2" 24" 0 C 2Vi" 24" O.C 3Vr" 24" O.C 3 V 24" O.C. IV 24" O.C. 2 Vi" 24" O.C
3 V 24" O.C. 3V24BO.C. 3V 24* O.C. 3 V 24" O.C.
THICK- WEIGHT NESS LB/SQ.FT.
WALL SURFACE
FIRE RESISTANCE
RATING 1
TEST REF.
4V 4V 4V bVi"
4 %" 5 Vi" 6V 5V (N) -
5.2 5.9 6.0 --
7.0 9.5 12 0 85 13.4
V Bestwall Firestop. Both sides Vi* Bestwall Firestop, Both sides Vi" Bestwall Firestop. Both sides, with Mineral Wool in stud space 3/a" Bestwall Firestop, 2 layers both sides
Vb" Bestwall Firestop, Both sides V Bestwall Firestop, 1 layer one side, 2 layers other side V Bestwall Firestop. 2 layers each side Vb" Bestwall Firestop, over V?" sound deadening board both sides ye" Bestwall Firestop, 2 layers each side staggered studs
30 Mm. 45 Min. 1 Hr. 1 Hr.
1 Hr. Wi Hr.
2 Hr. 1 Hr. 2 Hr.
EST. u.l. #1 BMS 92 U.L. #6
u.l. ms EST. T-194 T-3006 EST.
5V
5.4
Vb" Bestwall Firestop. 1 layer nailed one side, 1 layer on resilient
1 Hr.
EST.
furring other side
53/b"
54
V Bestwall Firestop, 1 layer nailed one side, 1 layer on resilient
1 Hr.
T 3127
furring other side plus fiber glass insulation m stud space
6" 8.1 yB" Bestwall Firestop, 2 layers one side, 1 layer on resilient
1 Vi Hr.
EST.
furring other side
(N) 4'/a" 6Va"
6.5 6.5 11.5
ye" Bestwall Firestop. 1 layer each side Vs" Bestwall Firestop, 1 layer each side Vb" Bestwall Firestop. 2 layers each side
1 Hr. 1 Hr. 2 Hr.
T-209 U.L. #2 EST.
BLDG.COD APPROVAL
-- B*. C B*. C
-- ABC
--
A, C -- -
A, C*
ABC AB --
2 Vb* 4V 3`Vje*
3V
5 V?" 5 Vi"
3V
5" 4 Vi"
6V
6V 6"
6V
5.4 6.0 4.2
--
8.1 81
8.4
10.4 6.0
10.4
1 1.0 8.8
11.1
Vb" Bestwall Firestop, 1 layer each side
1 Hr.
Vb" Bestwall Firestop, 1 layer each side
1 Hr.
Vi" Bestwall Firestop over Vie" Noise Stop Board one side, Vi"
1 Hr
Bestwall Firestop other side, fiber glass insulation in stud space
Vb" Bestwall Firestop, 1 layer each side, face layer Eternawall
1 Hr.
(movable partition)
ys" Bestwall Firestop, 1 layer one side, 2 layers other side
1 V2 Hr.
Vb" Bestwall Firestop, 1 layer one side, fiber glass insulation in
1 Vi Hr.
stud space, 2 layers other side
Vb" Bestwall Firestop, 1 layer one side, fiber glass insulation in stud Pfi Hr.
space, 1 layer Va* Bestwall Firestop over l"core board other side
Vb" Bestwall Firestop. 2 layers each side
2 Hr.
Vi" Bestwall Firestop, 2 layers each side
2 Hr.
ys" Bestwall Firestop. 2 layers each side, Eternawall face layer (movable partition)
Vb" Bestwall Firestop. 2 layers each side ys' Bestwall Firestop, 2 layers one side, 1 layer over Vi" fiber
glass board other side Va" Bestwall Firestop, 2 layers each side, fiber glass insulation
in stud space
2 Hr.
2 Hr. 2 Hr.
2 Hr.
T-231 6 T-201 6 T-3500
T-2898
EST. T-3126
EST.
T-2557 T-32 1 8
T-2406
EST. EST.
EST.
A. C* AB --
A -- A
~ A A, 8*. C*
ABC
--
--
Metal Faced Non Load Bearing
Steel Faced Wall Elwin G. Smith & Co Inc. Steel Faced Wall
(Walcon Corp ) Aluminum & Steel Unit Part.
(R.C. Mahon Co.) (R.C. Mahon Co.) (R.C Mahon Co ) Steel Faced Wall (H.H. Robertson Co )
Semi-Solid: Gypsum Stud Non Load Bearing
-
-- -- --
-
2V 4V
-
-- -
-
7.2 7.9
Solid Gypsum Board
Double Solid Gypsum Board
EXTERIOR WALL: S.E. Galv. Panels 2" x 4" Wood Studs: 16" 0 C.
2%" 6" 4" 5" 5" 5"
--
FLOOR & CEILING:
Ceiling
Wood Joists 16" O.C.
Finished floor on rough subfloor
9.1
95 13.4 13.4
_
-
11.4 13.0 13.0 12.0 16.0
Steel Bar Joists 24" O.C. 2" Concrete Floor on Metal lath centering
With 2Vi" Concrete Floor
STEEL COLUMN Fire Proofing
Ceiling
34.2 32.0 33 9 34.1
38.5 39.3 38.0
-
-- -- --
Vi" Bestwall Firestop, 4 layers
Vi" Bestwall Firestop, 4 layers
Vi Bestwall Firestop, 5 layers Vi" Bestwall Firestop, 4 layers V?" Bestwall Firestop. 2 layers each side Vi" Bestwall Firestop, 5 layers
Vi" Bestwall Firestop. 2 layers each side
Bestwall Hummer System "B" Vb" Bestwall Firestop. 1 layer each side 1" x 6" Rib 24" O C. V Bestwall Firestop over Vi" Sound Deadening Board each side
of 2Vi" x 3" Gypsum Rib 24" O.C.
Vb" Bestwall Firestop each side 1' Core Board
Vb" Bestwall over Vi" Bestwall Firestop, each side 1* ribs Vb" Bestwall Firestop, 2 layers each side 1" Rib Vs" Bestwall Firestop. 2 layers each side 1" Rib
Vb" Bestwall Firestop, 1 layer each side iy4" x 6" Gypsum Rib with exterior Stran-Wall (S E. Panel)
Interior. Ve" Bestwall Firestop. Exterior; Vi" gypsum sheathing and wood siding or other
Interior: yB" Firestop, 2 layers. Exterior. Vi Bestwall Gypsum
Sheathing 2" x 8" T & G and 4" brick wall
Vi* Bestwall Firestop Vi" Bestwatl Firestop Vi" Bestwall Firestop applied to resilient metal furring 24" O.C. Vb" Bestwall Firestop Ve" Bestwall Firestop 2 layers with resilient furring channel 24"
O.C between layers
VBn Bestwall Firestop nailed or screwed to metal furring 16" O C. Vb" Bestwall Firestop, metal furring 24" O.C. Vi" Bestwall Firestop, metal furring 24" O.C. Vb" Bestwall Firestop, metal furring 24" O.C.
Vi" Bestwall Firestop, metal furring 24" O.C. VB" Bestwall Firestop, metal furring 24" 0 C. Vb" Bestwall Firestop "120'' ceiling tile, metal grid 24" O.C. Vb" Bestwall Firestop "120" ceiling tile, metal grid 24" O.C.
yB" Bestwall Firestop. 1 layer Vs" Bestwall Firestop, 2 layers V Bestwall Firestop. 3 layers Va" Bestwall Firestop, 4 layers
2 Hr.
2 Hr.
2 Hr. 2 Hr. 3 Hr. 3 Hr.
2 Hr.
1 Hr.
1 Hr.
2 Hr.
Wi Hr. 2 Hr. 3 Hr.
1 Hr.
1 Hr.
2 Hr.
45 Mm. 1 Hr. 1 Hr. 1 Hr.
2 Hr.
1 Hr. 1 Hr. Wi Hr. Wi Hr.
2 Hr. 2 Hr. 2 Hr. 2 Hr.
1 Hr. 2 Hr 3 Hr. 4 Hr.
U.L. #12
U.L. #10
U.L.#9 U.L. #5 U.L. #8 U.L. #7
U.L. #8
C* C*
c* c*
c*
U.L. #10
T-3128
EST.
U.L. U.L.#7 U.L. #5
T-3039
T-99 BMS 191192 U.L. #23
ABC
A
A\ B* ABC ABC
--
--
U.L. #1
U.L. #46 U.L. #33 U.L. #1
C
A. B*. C* A, B*. C
AB
U.L. #217 A. C*
U.L. #2
U.L. #19 U.L. #17 U L. #13
ABC
A*, C A*. B*. C
a*, e*, c*
U.L #237 A*. B*. C*
U.L. #69
ABC
U.L. #208 ABC
T-2104
ABC
EST.
U.L. #8 U.L. #18 EST.
A A, C* A, C*
A
Fire Hazard Classification --Official Underwriters' Tests.
W and
Bestwall Firestop, 10-25 (LABELED)
For all 45 min. and 1 hour ratings Vs" plywood (underlayment grade. T86) over building paper, over Vi" structural interior plywood (with exterior glue grade- CD) may be used over the wood joists with other ceilings as detailed.
Appl'ed for Approval--1965 1 Official Underwriters' Tests have proven joint finishing is not required for
the rating in assemblies of Firestop. Under "Model Building Code Approvals" A. refers to International Conference of Building Officials; B. refers to Southern Building Code Congress; C. refers to
Building Officials Conference of America. Additional Approvals requested.
LABEL SERVICE SYMBOL FOR Vz BESTWALL FIRESTOP
FIRE HAZARD CLASSIFICATION
Flame Spread Fuel Contributed Smoke Developed
FIRE RESISTANCE CLASSIFICATION
FLOOR AND CEILING
Design No. 2 Design No. 1
Design No. 33 Design No 46
Design No. 17
Design No 237
30 Min. 45 Min
1 Hr. 1 Hr. IV2 Hr. 2 Hr.
WALLS AND PARTITIONS
Design No. 1 Design No. 4 Design No. 5
Design No. 8 Design No 9 Design No 10
45 Min. 1 Hr. 2 Hr. 2 Hr. 2 Hr. 2 Hr.
Design No. 12 Design No. 7 Design No 8
2 Hr. 3 Hr. 3 Hr.
COLUMN PROTECTION Design No. 21 4 Hr.
FIRE HAZARD CLASSIFICATION
Flame Spread Fuel Contributed Smoke Developed
15 15
0
LABEL SERVICE SYMBOL FOR W BESTWALL FIRESTOP
FIRE RESISTANCE CLASSIFICATION
FLOOR AND CEILING
Design No. 69 Design No 217 Design No. 13 Design No. 2 Design No. 1
2 Hr. 2 Hr. l>/2Hr. 1 Hr. 1 Hr.
COLUMN PROTECTION
Design No 18
3 Hr.
Design No. 8
2 Hr.
WALLS AND PARTITIONS
Design No. 5 Design No. 7
Design No. 23 Design No. 5 Design No. 10
3 Hrs. 2 Hrs.
2 Hrs. 1 Hr. 1 Hr.
The lobel Service symbol of Underwriters' Laboratories, Inc., which oppeors on the twin mounting tope, binding each bundle of two pieces, is the method pro vided by Underwriters' Laboratories, Inc., to identify gypsum wallboard which has been produced under the label Service. And especially important to archi tects ond building inspectors, the front of each sheet is marked: "Vs" or 1/2" Bestwall Firestop Type X" so thof it's easy to identify when in place-
GEORGIA-PACIFIC/ [bestwall] GYPSUM DIVISION
S INDUSTRIAL BLVD. PAOL1, PENNA. 19301
SGP 0025282