TO: John Nelson ' ' -- ----- Interoffice Communication FROM: DATE: SUBJ: Tom Grumbles May 15, 1985 VISTA PETROLEUM SOLVENTS TECH DATA SHEETS Enclosed is draft text for the Safety and Handling and Storage and Transfer sections for subject Tech Data Sheet. Please replace those sections with this text. Thomas G. Grumbles Enclosure VVV 000015732 SAFETY AND HANDLING VISTA Petroleum solvents are volatile liquids, and their vapors can be readily ignited. Handling should be done only with adequate ventilation and care taken to avoid inhalation of vapors and repeated or prolonged contact with the skin. All contact with the eyes should be avoided. STORAGE AND TRANSFER VISTA NPSO and HPSO are classed as flammable liquids by DOT and OSHA. VISTA MR and LPA are classed as combustible liquids. Transportation, storage, and handling must be done in accordance with specific DOT and OSHA regulations governing these materials. Storage in carbon steel tanks is suitable. Conventional lines, pumps, hoses, and fittings are satisfactory for use. Normal precautions against corrosion of equipment from water leaks or condensation should be taken. THE DATA CONTAINED.......... etc. VVV 000015733 Vista Chemical Company Vista Petroleum Solvents Headquarters Vista Chemical Company 15990 N. Barker's Landing Road Post Office Box 19029 Houston, Texas 77224 Phone <713)531-3200 Telex 794557, TWX 910-881-7329 FAX (713) 531-3236 Domestic Sales Offices Eastern Region Park 80 Plaza East Saddle Brook, New Jersey 07662 Phone <201)845-3800 FAX <201)845-6807 Midwestern Region 222 Camden Court, Suite 120 Oak Brook, Illinois 60521 Phone <312)655-7070 FAX (312)655-7086 Southwestern Region 15990 N. Barker's Landing Road Pest Office Bor 19029 Houston, Texas 77224 Phone (713)531-3200 Telex 794557, TWX 910-831-7329 FAX <713) 531-3236 Western Region Smoketree Plaza 1450 N. Tustin, Suite 100 Santa Ana. California 92701 Phone (714)541-8449 FAX (714) 541-0567 International Sales Offices Vista Chemical Latin America S_A. 159S0 N. Barker'3 Landing Road PostOffice Box 19029 Houston, Texas 77224 Phone <713) 531-3200. Telex 794557 FAX (713) 531-3236 Vista Chemical Europe Hilton Tower Boulevard de Waterloo, #39 B1000 Brussels, Belgium Phono (32-2) 513-7490 Telex 24727 Cable: VISTACHEM, Brussels Vista Chemical Far East, Inc. Post Office Box 110 Xasumigaseki Building, 25th Floor Tokyo, Japan 100 Phone (81-3) 593-0611, Telex J29368 Cable: VISTACHEM, Tokyo FAX 011-813-593-0615 / t. i. VVV 000015734 Vista Chemical Company Vista Petroleum Solvents Description/Applications: NPSO Vista NPSO solvent is a high-purity solvent naphtha with a typical boiling range of 200-350 F and an aromatics level of ten percent. NPSO solvent is suggested for use as a vehicle for inks and coatings and in general applications for solvent naphthas. NPSO should pass California's Rule 66, which prohibits the discharge of photochemically reactive solvents. NPSO is also suitable as a feedstock for BTX units, naphtha steam crackers, and reformers. HPSO Vista HPSO solvent is a severely-hydrogenated solvent naphtha. It has extremely low levels of aromatics, sulfur, and nitrogen and a boiling range similar to Vista NPSO solvent. HPSO is suitable for ink and coating applications or where a low-aromatic naphtha is required. HPSO complies with California's Rule 66. Its high purity also suggests H PSO for use as a process solvent or product carrier where high purity and low odor are critical. MR Vista MR solvent is a high-purity hydrocarbon in the kerosene boiling range. It is colorless and has a mild odor, low viscosity, and a typical aromatics level of 15 percent. Vista MR solvent has extremely low sulfur and nitrogen contents. Vista MR solvent is suitable for use as a coatings vehicle, No. 1-K low-sulfur kerosene for heaters and lamps, drilling fluid base oil, and in other applications requiring a highly-refined kerosene. MR solvent is expected to comply with California's Rule 66 limiting the use of photochemically reactive solvents. LPA Vista LPA sol vent is a very high-purity aliphatic hydrocarbon solvent in the kerosene boiling range. It is a colorless liquid with a mild odor, low viscosity, and extremely low aromatics, sulfur, and nitrogen contents. LPA solvent is suitable for use in the applications listed above and also as a component in household products, agricultural chemicals, or as a chemical process solvent. LPA solvent qualifies for safe use under California's Rule 66 prohibiting the use of photochemically reactive solvents. LPA also qualifies for use in a wide variety of Food-related applications where a low level of polynuclear aromatics is essential. Solvents of this type are described in CFR 172.884,178.3650, and 178.3620. Further details can be found in the Technical Data Sheet for Vista LPA solvent. VVV 000015735 Technical Data for Vista Solvent Products Distillation Range, F (ASTM D-86) IBP 10 20 50 90 95 EP Aromatics, wfc.% Flash Point. F (Pensky-Martens) Color, Saybolt Water, ppm API Gravity Specific Gravity at 60/60F Bromine Number Sulfur, ppm Nitrogen, ppm Carbonyl as C = 0, ppm Aniline Point, F Kauri Butanol Value Viscosity, cSt 70 F 100 F MR 370 390 400 420 475 480 510 15 144 + 30 20 42 0.827 (<0.02) <1 <1 <10 145 33.5 2.17 1.63 LPA NPSO 370 200 395 250 405 258 430 273 475 294 480 300 518 350 0.1 10 144 + 30 20 44.1 < 70F + 30 27 55.5 0.806 0.757 <0.02 (< 0.02) <1 . <1 (f? 1.0 (10) 160 126 31.5 36 2.10 1.80 0.84 0.70 HPSO 200 250 258 273 294 300 350 0.1 < 70F + 30 27 57 0.75 <0.02 <1 <1 10 134 34 0.87 0.74 Estimated values are indicated in parentheses. All HPSO values are estimates. Safety and Handling: Exfcfcptforcombustibifrfey^theseproducts^ra^ent no extraohdijiary handling hazards>i5iorinalt good opel-ating procedures a?id*housekeepin^9h^uld ensure personnel safety, in any evenCno^rnal care shoulalaa^taken to avoi&^eoiitact with eyes or prolonged contact with skinfry>the solvent. THE DATA CONTAINED HEREIN ARE FOR GENERAL INFORMATIONAL PURPOSES ONLY. PLEASE REFER TO THE VISTA CHEMICAL COMPANY MATERIAL SAFETY DATA SHEET FOR SPECIFIC, COMPLETE INFORMATION REGARDING THIS PRODUCT. Storage and Transfer: (vents are classiR4as combustible liquiSs-and should be shippfcdsjn accordance witfr-DOT regulationsi>TiUe 49, Part 172, SubpiTrt&^C-shipping paperS^Q-marking and F->lacarding as directetkfcv Part 173.118(a). Handling should be in accordance with De^w^ment of Labor. Titre-S^j Section 1910.106. Storage in carbon steeH^nks is suitable, conventional lines, puntpsMioses and fittings arekzttigfactory for us> Normal precau^o*}s against corrosion ohs^ipment from water leaks or . condensation should be taken. ''Availability: Vista solvents are available in rail cars and tank trucks from Westlake, Louisiana. vvv 000015736 Vista Chemical Company Vista Petroleum Solvents / vvy 00001^737 Vista is a trademark of Vista Chemical Company. The above data are based on tests and experience which Vista Chemical Company believes reliable, and are supplied for informational purposes only. Vista Chemical Company and its subsidiary, Vista Polymers Inc., disclaim any liability for damage or injury which results from the use of the above data ana nothing contained therein shall constitute a guarantee, warranty, or representation (including freedom from patent liability) by Vista Chemical Company or Vista Polymers Inc. witn respect to the data, the product described or their use for any specific purpose, even if that purpose is known to Vista Chemical Company or Vista Polymers Inc. For detailed information regarding these products, please refer to the respective Vista Chemical Company or Vista Polymers Inc. Material Safety Data Sheet.