Document mprgydNKO0yVkM8Z2Ne1gkrVQ

, A i-iak. ACIDS TECHNICAL DIVISION VICTORIA PLANT TO : PROM : M. P. HAUSMAN ^.t-lSIARREN | ax' CC : T. L C. H W. A A. H Acid Babowic z Sohurtz Nickolaus I/H Pile 507.048 November 30, 1984 ASBESTOS PERIPHERY MONITORING - OP 5/5A SUMMARY Pour periphery samples were taken in the Acid Powerhouse Area while removing old asbestos insulation from three equipment pieces (desuperheater storage tank, deaerator heater and deaerator storage tank) on the 4th floor. All four samples were less than the 8 hr. TWA and the maximum asbestos exposure limits, thereby indicating the selected rope-off area was satisfactory. The samples were obtained using the NIOSH analytical Method PsCAM 239. The fiber counting analyses were performed by Clayton Environmental Consultants, Inc. of Southfield, Michigan. . DOCUMENTATION This memo with the attached tables and figure must incorporated in the Area I/H notebook. We suggest that the be reviewed with personnel working in the area. be data MONITORING RESULTS The monitoring data are summarized in Table I, the weather conditions in Table II and the sampling locations in Figure 1. The sampling was taken at a fixed location at the periphery of the work area for the entire time the job was being conducted. Samples #2 S #3 were downwind of the work area and would be expected to contain a higher asbestos loading. Sample #3 was the highest of the 4 samples at 0.16 fibers/cc for the equiv. 8 hr. exposure vs. 0.5 fibers/cc 8 hr. TWA limit. JCW/ms Attachments ViUW'l DUP 0814644 DU 009928 H>cwCOi DU 009929 O c -o o 00 <Jt>k utn DATE 10/6/84 N M M N N M N ft m M H It 10/7/84 M TIME 1 800 1 830 1 900 1 930 2000 2030 2100 21 30 2200 2230 2300 2330 2400 0030 0100 TABLE XI WINO DIR. MPH 1 30 1 70 1 70 1 72 1 70 1 70 1 70 1 70 1 68 1 66 0 1 60 1 58 1 48 1 50 1 50 16 14 10 10 9 9 8 9 8 8 8 8 8 8 8 TEMP 82 82 81 80 80 80 80 78 77 77 76 76 75 75 75 REL HUM 67 69 72 74 80 85 86 88 88 90 92 93 93 93 93 DUP 0814646 DU 009930 -LOCATION OF flPH ASBESTOS SAMPLING OCT. 1 9 8 4 DU 009931 mm malm s afe-^sim tiifcl11 CC: J. F. Hignite November 7, 1977 TO: W. P. LEDET Cl. H. NICKOLAlffO^ L. F. GETZ - 13 FRCM: L. T. FREELAND INDUSTRIAL HYGIENE FOR SHOPS $ SERVICES The program was developed with Andy Nickolaus and Lionel Getz and should cover the various aspects required to monitor personnel exposure. The programs will run concurrently and should be complete by the third quarter '78. The programs include -1) ORGANIC VAPORS a) Varsol and Kerosene Vapors Both solvents required because of solvent properties. Initial survey will be an area survey using the Century Portable G.C. Areas will include Central Shops, Transportation, Garage, and HMD, "Alathon", Acids Shops - time permitting. The results of survey will dictate if personnel monitoring is required. b) Methylene Chloride Use Century G.C. for an area monitor to determine preliminary exposure. May want to use Drager Tubes but must be careful with interferences. c) Paint Solvents The present practice-is to use a respirator to protect from Imron and/or zinc chromate. This is adequate but may need data if solvent exposure levels change (TDI and others). DU 009932 2) ASBESTOS No data currently exists on exposure or background levels. Mist carefully review sampling method. Select outside contact laboratory for analysis - consult with Haskell and ESD prior to selection. Program includes both area and personnel monitoring -- including Arthur Bros. Area monitoring for asbestos to include the following -Acids, Alathon, Nylon Plant Shops and construction sites. 3) METALS a) Zinc The fume study is complete and Mechanical is aware of results further monitoring not required for at least a year. b) Nickel No data available but will use same type sampling program as used with zinc. Will not separate nickel dust, oxide, or salts in first sampling but rather establish total nickel level when working with nickel. If exposure is low, no further sampling will be required. c) Silica Used in sandblasting and filter aid. Suggest a few area samples when unloading filter and may be sufficient. This represents a very low priority item. d) Silver and Cadmium Lionel is following this to find the Cadmium content of silver solder. A few samples may be sufficient to show if levels are acceptably low. e) General Programs If any metals are detected in significant quantities, a general area sampling program would be started. The analysis could be conducted by Columbia Scientific Industries (CSI), Austin, using neutron activation analysis. This service will provide good information on typical metal exposure levels. Measurement of respirable versus non-respirable particulates may be helpful. Would not conduct any of the general program items unless required by previous sampling information. DU 009933