Heating Systems Specialties
Armstrong Machine Works
Representatives in Ail
851 Maple Street Three Rivers, Mich.
Principal Cities
Armstrong offers two types of traps for heating, air conditioning, and steam distri
bution service. Standard Inverted Bucket Traps, the
type originated by Armstrong, are non airbinding and self-scrubbing. They are used for low,'medium, and high pressure service where relatively little air must be handled along with the condensate. Their free-floating lever design makes it possible to open very large discharge orifices com pared with the size of the trap itself.
Armstrong Blast Traps are used where
large amounts of air must be vented quick
ly when steam is first turned on. They have several advantages over the conven- ' tional float and thermostatic trap.
1. The Armstrong Blast Trap has but a single orifice to be maintained tight against' the full pressure differential.
2. Positive action. The discharge valve in an Armstrong Blast Trap is either wide open or tight shut. Fast opening and fast closing prevent wire-drawing.
3. Handles dirt. There ate no dead spots in an Armstrong Trap in which dirt can settle and interfere with.the operation
of the trap.
Armstrong Machine Worths
Heating Systems Specialties
Part No. |
MATERIALS USED IN ARMSTRONG TRAPS
Name
| Material
/>.
I &2 3
4
5 6 7 8 9 10 It 12
13
Cap and Body... Scat........................ Guide Plate Pins. Valve..;................. Lever......................
Bucket. Retainer................. Gasket.................... Bolts and Nuts...
Thermic Vent.... Test Plug.............. Bucket Weight...
Cast Semi-Steel, 33.000 lb tensile strength Chrome Steel Stainless Steel 18-8 Chrome Steel Stainless Steel 18-6 Brass or Stainless Steel Stainless Steel 18-8
Compressed Asbestos 14 " Steel 90,000 lb minimum tensile Stainless Bi-metal and Stainless Steel Steel Castflron
Valve and Seat are heat treated after machining.
4. The wearing parts in all Armstrong Traps are identical in design, material, and precision workmanship with parts used in
Armstrong Forged Steel Traps for pres sures up to 1500 lb gage and total tempera tures of 850 F.
Armstrong Steam Trap Book. This 36 page book gives complete information on all sizes and types of Armstrong Traps. It also contains 17 pages of data on the subject of trap selection, installation, and
maintenance. A free copy will be mailed on request.
Cross-section of No. 200 ") and No.- 202 04') `raps for
straight-through connections.
ALL Armstrong traps are readily convertible into "Blast" type traps merely by using buckets equipped with the patented auxiliary thermic air vent. As shown in the above sketches, the mechanism for this vent consists of a stainless steel disc slotted to receive the end of a bi-metal strip. Different coefficients of expansion in the bi-metal cause it to bend down when cold and up when hot.. Normally, it is set to close at 212 deg, but it ca_n be set to close at higher temperatures. Capacity, 500 to 1500'cu ft of free air per hour depending on size of bucket.
Traj)S No. 200-203
Trap Size
[No. 200 ' No. 201
No. 202
No. 203
Pipe Connections........... List Price (Regular). . . List Pnce (blast 1 rap)
Telegraph Code (Blast Trap)...
B ............... C............... D............... E...............
Maximum Pressure, lb
Continuous discharge
5
capacity in lb of water i 15 per hour at pressure 2 20 indicated, For more
complete information see the Capacity Chart in Armstrong
50 ^ 70
Steam Trap Book.
125
Vi" $7.00 $8.50 Acacia Acaeette.
w/
6 / 41b 125
Vi' $7.00 $8.50 Acanthus Acanette w w
2" / 6 v."
41b 125
450 450 560 560 640 640 690 690 500 500 580 580 660 660 640 640 680 680
V." $7110 $8.50 (Juacia Ouacette 3%" 4W . 5"
6 Vs* 4 lb 125
450 560 640 . 690 500 580 660 640 680
y." $7.00 $8.50 Quanthus Quanette 3}4n 5hi"
w 6 Vs" 4 lb 125
450 560 640 690 500 580 660 640 680
1002
Trap Size
Pipe Connections................................
List Price (Regular).............................
List Price (Blast Trap).......................
Telegraph Code (Regular)..................
Telegraph Code (Blast Trap)............
Height................ DimensionB...........
Diameter................
" A .........
Wall Thickness
" C.............
Diameter of Bolts.................................
Number of Bolts....................................
Weight......................................................
Maximum Pressure...............................
Continuous discharge capacity in lb of water
per hour at pressure indicated. For more
complete information. see the Capacity Chart in the Armstrong Meam 1 rap Book.
5 10 15 o 20
5 30 8 50 70 _Q 100 -1 125
150 200 250
Traps No. 211-216
No. 211
No. 212
No. 213
'/zn $ 9.25 $10.75 Aspen Aspette
w 4'/"
w
6 %Ib
200
>/2"orV4? $15.00 $17.00 Birch Birette 8" 5n l/4n l/4n
8 IO/2lb
200
i/2ory4" $20.75
. $22.75 Walnut Walette
y$n 56" Vs*1 6
191b 250
830 950 1060 880 1000 840 950 860 950 810 860 900
1600 1900 2100 1600 2050 1900 2200 1800 2000 1500 1600 1680
2900 3500 3900 3500 4000 4100 3800 3600 3900 3500 3200 3500
1003
No. 214
1" $29.00 $31.50 Hemlock Hemlette l2/;n
w V %" 8
32 lb 250
4800 5800 6500 6000 6800 6300 6000 6200 6700 5700 5300 5700
No. 215
1 n or l/4 $38.00 $40.50 Larch
liLarette - 14"
%
Vi" 8 47 lb 250
7600 9000 10000 8500 9800 9000 9200 10400 10900 9500 9200 7000
No. 216
V/zn or 2M
$55.00 $60.00 . Tamarack Tamrette 163/4 io%
Vi" 12 801b 250
14500 17300 19200 18500 16000 18200 18300 16000 20000 18500 17500 19000