Document mp7rE0MXbJd40GjoNbkBb1ODZ

c --c vtetj'(>* AVOID VERBAL INSTRUCTIONS FROM_ BLDG./ROOM _ >Q~7- GstVS.KT/^C=. SUBJECT. pa mi on OMattftM. n - mm mi mm T0- VO r\S, BLDG./ROOM. sv*\ \v\-:s ^.9. CouvOoVEfe-- COPY. t^~'V>\V1PV\ Y1-- DATE Ai-A % r ~Hx: --W\\QdWT '^TVNC^I^ \N\OW\C^ \o> Mve:'^ V=- i v^cJZs^f ^ <^vw\ P^vfvsi S. cxro ok> 'PV31Si?S.Te>s. YAftTEvii Pr<L. . fc UUUT)1T6T5 C o (>*-x To vW> S ECU 004 P c_ V* * n UNION CARBIDE CORPORATION TECHNICAL CENTER SOUTH CHARLESTON. WEST VIRGINIA MEMORANDUM June 22, 1982 RECEIVED JUN zafgsz p. hefneh TO: COPY: FROM: SUBJECT: "SEE ATTACHED DISTRIBUTION LIST" Mr. G. M. Ever Itt Mr. J. C. Hovlous Mr. P. R. Schweppe Mr. L. S. Slaughter Mr. W. G. Ashbaugh/D. W. Moody, Jr./C. C. Neely Non--Asbestos Compressed Non-Metal lie Gasketing Materials Salesmen calling on us and advertisements in the literature have been extolling the virtues of non-asbestos compressed non-metalilc gasketing materials as a universal replacement for the compressed asbestos gasketing that we have used for many years. We wish to caution you that the non-asbestos compressed non-metal IIc gaskets have not been proven in our services. More over, limited testing of these gasketing materials In our materials laboratory has indicated that from a chemicaI-res 1 stance standpoint they are inferior to compressed asbestos gaskets and have a lower maximum temperature limit. In addition, we have not tested the non-asbestos gaskets from a mechanical stand point; therefore, we have no data concerning their sealabillty, bolt load re quirements and other Information of a mechanical-desIgn nature. Compressed asbestos gaskets are still widely available and generally cost less than the newer non-asbestos gaskets being offered as their replace ment. We should continue to use the compressed asbestos gaskets approved In our standards and specifications for process vessels and piping. Approved com pressed asbestos gaskets are listed In COP-1 for Pressure Vessels and PPF-1* for Piping. In the event that compressed asbestos gaskets are not available for a specific Installation,' the approved substitution for standard pipe sizes would be a GRAFOIL gasket. GRAFOIL Is available In several forms, including tape, GHE (metal inserted), and splralwound with a GRAFOIL filler. We recom mend that you check with the Process Vessel Design group or the Piping Technology group in Central Engineering If there is any question regarding the proper sub stitution of GRAFOIL for an asbestos gasket, in many instances, it is important to insure that the substituted gasket has the same thickness as the asbestos gasket originally specified. UCC 011616 Page Two June 22, 1382 Although there appears to be no immediate prospect of asbestos gaskets disappearing from the market, it is important for us to obtain infor mation on the non-asbestos gaskets being offered as their replacements. For this reason, we encourage testing of these substitute gaskets in low-hazard piping and vessels where the penalty for failure would be low. Services such as water, nitrogen, air, low pressure steam and ethylene glycol might be can didates for such testing. We recommend that you consult with your local cor rosion and materials engineer before you do any testing of the substitute gaskets and keep him advised of the results. The corrosion and materials en gineers will collect Information on the substitute gaskets for possible future use. In summary, don't be misled by the claims being made for non asbestos compressed non-metal I|c gaskets offered as substitutes for the ap proved compressed asbestos gaskets specified In our standards and specifications Except for specific testing for the purpose of collecting data on these sub stitute gaskets, do not use them. They are untried and unproven in our services Limited testing has shown that they have poorer chemical resistance and lower maximum service temperatures than compressed asbestos. Compressed asbestos is still widely available and generally costs less than the substitute gaskets. WGA:DWM,JR:CCN/gp Attachment (Distribution List) Neely UCC 011617