ASBESTOSPRAY CORPORATION High Temperature Insulation GENERAL SPECIFICATION FOR EXPOSED EQUIPMENT SUCH AS HEAT EXCHANGERS, STORAGE TANKS, VESSELS AND VESSEL FLASHING AT THE EAVE WHERE THE TOP IS NOT INSULATED. FLASHING AT THE EAVE: A steel angle shall bt welded continuously around the eave of the tank by others. It shall exceed the thickness of the insulation by at least % inch. APPLICATIONi Surface preparation The surface to be insulated with Asbestotpray High Temperature Fiber must be cleaned and free from all dust, grease (caked or fluid), paint and rust scales which could result in a false bond. This could lead to delamination and complete seoaration unless the insulation is reinforced by mechanical support.. SUPPORTS! Where the insulation thickness exceeds 2 inches and where the diameter of the vessel is more than 4 feet, mechanicol support in the form of welded pins or studs is recommended. These pins or studs can be used for hexagonal mesh, lacing or speed washers depending upon the individual conditions, finish and specifications of the owner, and can be from 12" O.C. on the bottom to 24" O.C. on the top of the unit insulated. FINISH; After Asbestospray High Temperature fiber has been applied and pressed to the proper density and thickness, regular 1 inch 20 gouge hexagonal wire mesh (galvanized or monel as specified) shall be wrapped around and laced according to standard practice. After the wire mesh has been applied and laced, two coats of approved mastic shad be applied. The first coot applied as a "mud" is troweled into and flushed with the wire mesh so that a uniform surface is achieved. The second coat shall be applied immediately after the initial set and while the first coat is still damp. The second coat shall be applied so that the minimum dry thickness shall be 1/8" on top of the wire mesh. Where possible fire hazard conditions exist, mastics carrying on Underwriter's label are recommended. Where acceptable or desired, the 20 gauge hexagonal mesh can be replaced with four (4) inch squares of hardware cloth. The 4" x 4" squotei of half inch hardware cloth are to be impaled onto the pin into the sprayed fibre insulation after it has been applied end before final pressing, so that the .haedmate .doth, -which w-if! -secured *by c speed clip, is covered by ot least one-quarter tl 4") inch of fibie which is to be applied ofter tne hardware cloth is in piace and secured. Where the logging or weatherproofing is not in contact with the insulation, the hardware cloth and speed clip can be applied after pressing, if it will not affect the appearance or durability of the coating. CEMENT TYPE FINISH (Heavy Duty) If a cement type finish it required, Atbesto-cote finishing cement shall be applied (sprayed or troweled) over the hexa gonal mesh to e minimum thickness of '4 inch over the Asbestospray fiber insulation. Where contraction and expansion ore such that if is liable to Induce cracking, the cement finish is to be scored with a cement finishers fool in squares approximately 4' x 4'. It is important to note thot scoring must be through the cement finish to the surface of the Asbestospray fiber. Additional protection con be secured by applying fiberglas reinforced masties or resins. ALUMINUM JACKET FINISH Where aluminum jackets ore tpecifleed for weather-proofing, it Is recommended that aluminum with factory applied moisture barriers be used. PLAINTIFF'S EXHIBIT wyimzio PLAINTIFF'S EXHIBIT ~1Q (30.601 CE0113793 CE/HI (F) 33952