Document mmy46L612OX2V8RwM4L36Ld2O
424
Heating System*
JENKINS BROS.
100 Park Avenue, New York 17, N. Y. Bridgeport, Conn.; Boston, Philadelphia, Chicago, San Francisco, Atlanta
DO YOU HAVE THIS HELPER?
For dear, complete, easv-to-find data on valves and bow to select and use them, reach for this latest Jenkins Catalog.
From cover to cover this 296 page general catalog of Jenkins Valves was designed to give specifiers and buyers all the data they want. . . and FAST. It's the book to reach for FIRST when you need valves or valve information. Write for your copy.
Heating System* Sftdillla, Valve*
425
MARSH INSTRUMENT COMPANY
Division of Colorado Oil and Gas Corporation
Ma(CrsahnaIndas)trLutmde.,n8t40a7w1l0V3radlvSetC., o. Edmonton, Alberta
T)pnL "PU
5 *5
SpKkOnKlfllPC,
Tllinnie IIUHOIS
Branches in Principal Cities
HoRusottohnwBelrlaSntc.h, SPelactn. t1:51,121 Houston, Texas
Marsh products include: Pressure, Vacuum and Compound Gages; Dial Thermom
eters; Steam Traps; Vents; Packless Radiator Valves and Radiator Traps; Refrig eration Water Regulators; Refrigeration Testing Instruments; Solenoid Valves; Needle Throttling Valves.
Radiator Traps--Equipped with the famous Marsh phosphor
brotue diaphragm charged with volatile fluid. Extremely rugged,
but so sensitive it closes tight on steam and opens instantly to pass condensate and air at only a few degrees below closing
temperature. Highly efficient on pressures from below atmos pheric up to 25 psi. Other traps available for pressures up to 125 psi.
Pressure Ganges and Dial Thermometers--The respected
Marsh line covers every requirement for pressure, compound, altitude gauges, tber-altimeters and dial thermometers. Marsh
instruments are the product of nearly a century of experience. Sixes, ranges and case styles for all needs.
Marsh Radiator Trap and Packless Valve. Both are available in full range of
patterns
Packless Radiator Valves--Not just packless in name; in genious Marsh annular mechanical seal does away with pack
ing of any kind. Valves close on less than one turn. For either
steam or hot water. Maximum water pressure, 125 psi.
Float and Thermostatic Traps--De signed for complete removal of air and condensate from steam mains, branches and risers. Condensate discharged through
float operated valve at bottom; air through vent in top. Widerange of pres sure and capacity ratings. One of the many float and thermostatic traps is illus trated. Line also includes float traps.
Marsh Float and Thermostatic .
Trap.-
Inverted Backet Traps--Marsh quality
and performance in a trap for applica tions where the inverted bucket type is indicated.
Air Vents--Automatically remove air and gasses from tanks, coils or piping, liquid pump systems, and other similar applications. Float holds valve tightly closed when system is filled. Opens only when air accummulates. Has vacuum check which prevents return of air. Type illustrated is for working pressures up to 125 psi. Other types, including float and thermostatic types, for low pressure.
Marsh Inverted Bucket Trap.
Marsh No. 50 Air
Vent
Solenoid Valves--meet a wide range of
needs. Latest addition to line is the
"Masstteerr--mmite",. i.l.l.u..s..t..r.a..t.e...d..,....d.esigned to meet the need for positive-acting tight-
seating valves for many uses. Two types* direct actiin--g---c--o--nJd--u:*it --and grommet types
(conduit t.ype illustrated.) Two port sixes:
MI in. and w in. NPT. Ten orifice sixes:
3/64 in. through VL in. Wide range of
"'voltages: 12, 24, U$i208, 230 and`*460V,
a-c. Pressures from vacuum to 540 psi.
Underwriters' approved as safety valve.
Other Marsh Solenoid, both direct acting "Master-mite'*
and pilot operated, cover a broad rangeoi Solenoid Valve
requirements.
Conduit type
Marsh Ther-altimeter
Marsh Onnce-graduated
(Square and Round types)
retard gauge
Refrigeration Valves--Recent addition to the Marsh line of water regulating valves is the Type 56 pressure actuated regulator illustrated. It is adjustable' for both Refrigerant 12 and 22--adjustable from 60 to 270 psi--by simply twisting handy knurled cap on bottom. Although small and compact for installation in tight quarters, it has ample capacity for wide range of applications. Other Marsh Water Regulators, both temperature and pressure actuated, for practically every cooling or heating application.
Type 56 Water Regulator
Piping and Duet Thermometers--De signed expressly for piping, air ducts, vessels, kilns, ovens, etc. Unbreakable. Greater reading accuracy than glass tube thermometers. Complete line: 4 types; 7 ranges; 72 combinations to meet every condition. Big legible 3V4 in. and 4 in. dials easily tilted or turned to any reading angle. Direct mounted types are illus trated, but line also includes distant read ing types. Separable sockets make instal lation easy. Extension necks for insulated piping or ducts. Long stems in duct types place temperature-sensitive section where it should be for accurate indication.
Marsh Piping / Thermometer
Ask for catalog. Hie comprehen sive Marsh line is merely high lighted here. Ask for information covering yoor specific needs.
Marsh Duct Thermometer