Document mmq75jr2QKM4MkXLQzRYRGVG0

Sample Area Choccolocco Creek. 1. ntle above Uwy 71 bridge In Talladega County near Anniston, AL Dennison Slough Wilson Reservoir, AL Sample Composition 2 Coldfish 4 Ctumnel Catfio.lv 4 Gizzard Shad 1 Rcdoar Sunfioh 4 Larnemouth Baso 3 Car 6 Gizzard Shad 3 Lavf'C'jnouth Bars 3 Redear Sunfish C.0 4S1 \ Ci i *1^ cl PCI)';; (uy/^m) 10.1.5/1242 1254 10.5 78.8 0.26 7.00 *S,0 (rO, O ukolc MGNi 090284 Methods Preparation of Samples The fish were collected by state and federal field crews and stripped frozen to Duluth. The fish in eacli sample were homogenized as a composite and given laboratory numbers consecutively fron 1 to 58. Sub-samples weighing 30 gms and 20 gras were exhaustively ex tracted with a Soxhlet extractor using a 1:1 mixture of hexane and methylene chloride. The 20 gm sample extract was concentrated and placed on a 20 gm Florisil column. The PCBs and related chemicals were eluted with 250 ml hexane, and the extract was concentrated to 100 ml for Initial EC screening. The 30 gm sample was concentrated to 100 rog/ml lipids in methy lene chloride for cleanup by gel permeation chromatography. The extract was cleaned up by sequential elution of 5 ml aliquots on a bed of SX-2 Bio Reads (Bio Rad Laboratories) using methylene chloride as a solvent. The combined fractions containing the TCBs were passed through n column containing 15 gm Cclite 545 Impregnated with 9 mis of 1:1 l^SO^ and fuming U2SO4 (30% SO3). The extract was concentrated to 1-3 1 for screening with FID gas chromatography and then GC/MS analysis. ' Electron Capture CLC Analysis The extracts of the 20 gm tissue samples were analyzed for PCBs using n Hewlett Packard 5700A gas chromatograph equipped with a Model 3352B Laboratory Data System, an automatic sampler, and linearized MONS 090285 2 argon-methane detector^ The. column was a 6 ft. x 1/8 inch (O.D.) glass column pa cited with 80/100 mash. Cos Chron Q coated with 4 percent/ 6 percent SE-30/OV-210. The column temperature was programmed from 160C to 220C at 2C/min. followed by an 8 min. hold at 220C. The chromatograms were interpreted by a program prepared by tyc. Frank Puglfsi of the Environmental Research Laboratory - Duluth in which 10 reference FCB peaks were monitored. Eight reference peaks corresponded to PCBs found in Aroclor 1016 and Aroclor 1242, and eight peaks corresponded to PCBs found in Aroclor 1254. The program estimated the quantity of either Aroclor 1016 or 1254 based on the individual peak areas and then determined the mean and standard deviation of the respective mixtures based on all reference peaks found. Peaks with areas more than twice the standard deviation were considered contami nated by an Interfering chemical and were eliminated front the PCB estimate of the mixture. At least 4 of the 8 reference peaks were required to be present before an estimate of the PCB mixture was reported as an recognizable PCB mixture. CC/HS Analysis the extract of the 30 gm tissue samples were first screened using a flame ionization detector (FID) and then by GC/KS using identical GI.C conditions. The column was a 6 ft. x i/8 in. (O.D.) glass column packed with 80/100 mesh Gas Chrom Q coated with 3 percent OV-101. The temperature was programmed from 100C after a 5 min. hold to 225C at 4C/mtn. ' HONS 090286 The GC/.MS analysis was performed on a Varian Hat Ctl-5 mass spectrometer interfaced with. a Varian 6021 data system. Spectra were acquired repetitively every 7 seconds during the gas chromato graph elution and, after mass conversion on the 620i computer, were transmitted to a Varian 620L computer for data formating and analysis The screening of the GC/MS data was accomplished by selecting ions in the mass spectra of chemicals of interest and searching all of the spectra for the GC peaks where these ions occur most intensely The most rapid screening of this data is the mass chromatogram which Is simply a plot,of the intensity (heigh) of the characteristic Ion* or mass, as a function of GC retention time which is storod In the computer as the spectrum number (i.e. one spectrum every seven seconds). This produces a new "gas chromatogram" in which peaks are observed only if a chemical is present that has the selected charac teristic ions. MQNS 090^87