September 22, 1976
Results of VC1 Personnel Monitoring Cross Check Program h by
Richard D. Hardesty, Paul M. Zakrisk? and John M. Whitney
DISTRIBUTION
L. B. Crider
- ALTC
E. G. DeCapita - ALTC
R. W. McKay
- ALGC
D. J. Oesrosier s- ALGC
D. 3. F-chrock - Calvert City
E. E. Atkins
- Calvert City
C. D. McCrosky - Henry
A. W. Otto
- Henry
D. W. Robb
** Long Beach
C. W. Ball
- Long Beach
S. S. Michels - Louisvi1le
R. R. Taylor
- Louisvi1le
W. A. Reed
- Pedricktown
D. W. Wright
- Pedricktown
C. Reid
- Niagra Falls
J. P. Gregroire - Shawinigan
cc: E. B. Katzenmeyer, Jr. R. W. Strassburg 0. F. Beckmeyer J. A. Klupar A. W. Clements R & D Fi1es
THE B. F. GOODRICH CO.
OCT 5 197 &
RESEARCH LIBRARY
T
T00f>62?!
Results of VC1 Personnel Monitoring Cross Check Program "4
(
The results of the vinyl chloride Bendix flasher tube cross check program #4 show that 7 out of 10 labs are within 30fc of the theoretical calculated loading. Three labs, Shawinigan, Henry, and ALGC (Oesrosiers) are 60fc or lower. Niagara Falls had trouble with their flasher and didn't report test results.
TABLE I
Summary of Cross Check #4 Results
Laboratory
Average % Recovery
Standard Deviation
Long Beach Manufacturing Services
(Whitney)
Calvert City Brecksville Louisvi1le ALTC
Pedricktown Shawinigan
ALGC Henry
113.0 103.0
91.8 88.7 88.4 72.4 70.0 59-949.1 42.7
3-06 11.06
4.44 2.77 1.96 3*95 9.06 2.99 2.46 2.56
Table !1; (at end of report) is the complete listing of all results, it is clear from this table that the variation in results between tubes within a lab is far less than between labs. This indicates that the greatest effect on variability is measurement at each lab rather than a random error throughout the samples. in other words, the effect of (1) shipping to a particular lab, (2) running on a particular GC, and/or (3) using a certain calibration factor is much more significant than variations in loading or individual pecularities of each tube. Finally, the date of analysis seems to have less effect also, since Calvert City was the last to analyze their tubes and yet showed $2% recovery.
The cross check tubes were loaded 5 at a time from a 53 ppm gas cylinder. The VC1/ air mixture went through a regulator, SS tubing, rotameter, teflon tubing, and the 5 port manifold. See Diagram I . No vacuum source was used; the VCl/air was blown through the PMCC tube. While the tubes were being loaded, a soap film bubblemeter was connected to the exit stream of each tube and a flow reading made. At the end of a set time, (6 minutes), the five tubes were removed and capped. The theoretical loading was calculated according to the following formula:
cc soap film traveled 60 sec 6 min 53 ppro
sec
X I min X
X 391.2
Ug loading
ts:
After all PMCCs were loaded, they were all mixed together and then six tubes chosen at random for each plant. This was done to hopefully eliminate any extraneous effects
due to time of loading, position in manifold, etc.
20066.
Tt
2- -
The standards for the 8recksviI1e lab were prepared .in the same way except the 5 port manifold wasn't used. The teflon tubing from the rotameter was connected directly to an individual tube. The flow and total loading time was varied to achieve different loadings. Loadings were also made from a 508 ppm tank as well as the 53 ppm tank. The calibration curve obtained is linear, indicating the stated tank values are probably correct and that the loading variations in flow rate and time are quantitative.
At this time we aren't sure why we don't show 100$ recovery at Brecksville. Since PMCC tubes were used to calibrate the instrument, theoretically the recovery should have been 100$. We are looking into this problem further. Appartently there was a difference in our method of loading I vs. 5 tubes or something else. In any case the closeness of (within lab) results vs. lab to lab results shows that the loading is much more consistent than the analysis.
We will immediately send another set of tubes to Shawinigan, ALGC, and Henry to try and correct their percent recovery.
&
jb
DIAGRAM I VC1 Loading Arrangement
5 Port Manifold +
C
1/8" Stainless Steel
Jy + ------- ^ Bendix Tube
1/8" Teflon
53 ppm VC1 Tank
COOGGCZZ
-3-
TABLE II
Lab Results Cross Check #4
Laboratory
Tube #
Measured Loadlnq (uq)
% Recovery
ALTC
80 70.79
3-9 61.27 3-3 46.84
7 22.01 T-I 55.3*
67 38.07
66.2 74.4
73.7 77.2
73.5 69.3
BRDC 8/23
3-14
43 T-15
68
2
68.21
29.95
57-69 45.08 67-36
89.5 95.8
88.0 90.2 88.4
BRDC 8/31
T-20
35 50 88 3-20
74.00 65.69
56-99 102.36
70.59
86.2
87.3 87.5 87-3 86.8
.
Pedrlcktown 8/31
3-6 T-I9
31 79 26 86
43.1 71.9 31.0 48.8
56.9 42.3
79-9 73.1 71.7 52.8
71.8 70.8
Long Beach 9/1
T-2 T-8
T-17 21
39 77
115.9 80.8
88.3 48.6
89.7 52.4
110.3 >10.0
111.5 118.0 114.8 113-4
Louisvilie
42 44
3-11 12
75 19
32.87 34.79 76.04
48.79 47.79 34.51
87.3 86.2
88.5 90.4 87.0
91-1
ALGC 8/30
3-2 T-10
87 15 38
30
29.965
42.355 19.785
47.757 33.273 35.210
* Overall average of Brecksville results.
49.6
67.9 44.8
69.3 51-3 51.4
Average % Recovery
72.4
90.4 (88.7)* 87.0
. 70.0
113-0
88.4
49.1
Standard Deviation
3.95
3.15 (2.77)*
.53
9.06
3.06
1.96
2.46
tMOSSCZZ
-4-
Laboratory
Tube #
Henry
90 3-16
3-17 10 36
T-14
Manufacturing Services (Whitney)
35 28
T-3 48
3-3
Shawinigan 9/7
37 56
59 72 81
3-5
Calvert City
T-18
3-4 T-5 T-12
60 3-18
TABLE II (continued)
Measured Loadinq (uq)
% Recovery
21.81
30.79 31.73 11.57 24.77 4J.78
40.8
46.5 39.5 41-7 43.1 44.5
12.94 14.40 16.26 14.11 34.48
90.5 103.5 110.6 94.6
117-3
39.5 36.6 38.0 41.4 21.4
33-9
63.22 65.22 77.61 65.55 47.32 106.42
62.8 60.0 63.6 59.8 57.9 55.6
90.2 96.3 86.6 87.1 94.7 96.0
Average %
Recovery 42.7
103-3
59-9
91.8
Standard Deviation
2.56
11.06
2.99
4.44
SOOGSC2Z
T