Document mmkLxOYGeyDODLJOwGKoZjooO

Difr&tstv Bell Laboratories subject Environmental Measurements of Potential Asbestos Exposure to New York Telephone Employees Working at Yankee Stadium, Bronx, New York Case 48106-3 48087-1 date: May 12 1978 irom: V. R. Cohen R. Deitchman PLAINTIFF'S EXHIBIT MEMORANDUM FOR RECORD SWB-189 Potential asbestos exposure from flaking ceiling insul ation is a concern of New York Telephone employees working at Yankee Stadium, Bronx, New York. The entire clubhouse ceiling of the stadium was sprayed with Insulating material where New York Telephone employees have a storeroom, monitor the television - telephone interface, install and service telephones, and occasionally run cable for add itional telephone capacity. The Bell System Services Group at Bell Laboratories had performed an industrial hygiene evaluation on October 17, 1977.* Mr. V. B. McGuire, Supervisor-Safety of New York Telephone, requested two additional evaluation be made using more sensitive ana lytical techniques and during actual ball game conditions. Summary General environmental sampling and bulk sample collection was performed at Yankee Stadium, Bronx, New York on April 14, and 18, 1978 to evaluate New York Telephone employee exposure to asbestos. Analysis of the bulk spray insulation material indicates no asbestos fibers were present. Asbestos, in the platelet form, is present in the bulk material (10 percent from Cctober 1977 analysis) but, it is asbestos fibers that represent the health hazard. Air sampling with analysis by light and scanning electron microscopy indicate low levels of any fibers present with no detectable asbestos fibers. Memorandum for Record: Environmental Measurements of Asbestos Exposure tc New York ToV rh'-no Employees '.Corking at. Yankee Stadium, Bronx, New Yor,:, November 10, 1977. CONFIDENTIAL 003819 2 Re c oirnne ndat ions The recommendations are: 1. New York Telephone Employees working in Yankee Stadium should be informed of the results of this investigation. 2. The management of Yankee Stadium should be informed of the analytical results of the flaking ceiling insulation in the clubhouse area. Procedures Asbestos samples were collected using the procedures outlined by the National Institute for Occupational Safety and Health (NIOSH) and the Occupational Safety and Health Administration (OSHA). The procedure involves collection of the fibers on a small filter cassette with later analysis using phase contrast microscopy. Additional parallel samples were collected in the same manner for further analysis by scanning electron microscopy. These filters were sealed and shipped to EMV Associate, Rockville, Maryland where the analysis was performed. The light microscopy simply identifies all fibers greater than 5 microns (pm) with an aspect ratio of 3:1. Using scan ning electron mici'oscopy with energy dispersive X-ray analysis, only asbestos fibers are counted. Air was pulled through the filters using battery powdered sampling pumps manufactured by MSA and Bendix at 2.0 Jl/min. The pumps were calibrated using the soap bubble flowmeter technique. Bulk samples were taken by removing a small section of the spray insulation and placing it into a envelope. This procedure was completed after environmental sampling so the disturbance of the ceiling insulation would not contaminate the general air sampling. The material was sealed and shipped to EMV Associates, Rockville, Maryland for analysis. The bulk material was analyzed by scanning electron microscopy (SEM) with energy dispersive x-ray analysis (EDXA). This analytical technique involves fiber identification by the scanning electron microscope then using the energy dispersive x-ray analyzer to determine composition for positive identification of fiber type. CONFIDENTIAL 003820 3 Results Table I presents the analysis of the bulk spray Insulation performed by EMV Associates. Their results indicate no asbestos fibers were found In the bulk material. The results of bulk sample analysis performed last fall by ES Laboratories in Marlton, New Jersey showed some of the spray insulation to contain ten percent asbestos in the mineral phase. The SEM analysis by EMV Associates is designed to look more critically at fibers. Thus, the most probable cause of this difference in results (ten percent versus not detectable) is that the asbestos is in the platelet form and thus, non-fibrous. It is the asbestos fibers that present the significant health hazard. Another possible explanation of this difference is the composition of the spray Insulation is variable, but this possibility is unlikely since several samples from different locations were analyzed. Airborne asbestos levels measured on April l1!, 1978 are shown in Table II. These measurements were made during a set-up day for the telephone-television Interface. The light microscopy result shows a small number of fibers are present but, using SEM asbestos fibers were detectable at the 0.005 fiber per cubic centimeter level. Table III presents the airborne asbestos levels on April 18, 1978 during a ball game at Yankee Stadium. The results represent a similar situation as on April 14, 1978. V. R. Cohen Industrial Hygienist R. Deitchman Industrial Hygienist Copy to ----------------- - R. L. Beach - ftt?,tTM'co" F0Jm. N. J. DeCapua - AT&T V. B. McGuire - NY Tel W. J. Srhreibeis - BTL C. H. Steinmetz, M. D., - NY Tel R. W. Stone, M. D., - AT&T G. M. Wilkening - BTL Wood - NY Tel T" 2, 003821 Table I. Analysis of Bulk Spray Insulation Material Taken at Yankee Stadium, Bronx, New York.* April 18, 1978 Location of Sample Results of SEM*1 and EDXA2 Analysis of Sample Room B173 ceiling 99-9% fibrous glass and gypsum (no asbestos fibers detected) Room 524 ceiling 99`9* fibrous glass (no asbestos fibers detected) Hallway outside Room B173 celling 99.9% fibrous glass (no asbestos fibers detected) Floor outside Room B173 99.9% fibrous glass (no asbestos fibers detected) * Analysis performed by EMV Associates, Rockville, Maryland 1 Scanning electron microscopy 2 Energy dispersive x-ray analysis CONFIDENTIAL 003822 -5- Table II. Airborne Asbestos Levels Measured at Yankee Stadium, Bronx, New York, April 14, 1978 Location Duration (minutes) Concentration (fibers/cc) Area Sample Room B174 (NY Tel A2AT Transmission Equipment Room) Area Sample Room B174 129 129 0.08 BDL2 (0.005) Area Sample - Room B173 (NY Tel Supply Room) 115 BDL (0.005) OSHA Standard 480 2.00 1 LM = Light Microscopy 2 BDL = Below Detectable Limit 3 SEM = Scanning Electron Microscopy Method of Analysis LM*1 SEM3 SEM LM CONFIDENTIAL 003823 -6- Table III Airborne Asbestos Levels Measured at Yankee Stadium, Bronx, New York April 18, 1978 Location Duration (minutes) Area Sample Room B173 (NY Tel Supply Room) 255 Area Sample 0 Room B173 250 Area Sample - Room B174 (NY Tel A2AT Transmission Equipment Room) 127 Area Sample Room B174 12H Area Sample Room B174 140 Area Sample Hallway outside B173 on cable rack 187 OSHA Standard iJ8G Concentration (fibers/cc) 0.07 BDL(0.005)2 0.07 BDL(0.005) BDL(0.005) 0.05 2.00 Method of Analysis LM1 SEM3 LM SEM SEM LM LM 1 LM = Light Microscopy 2 BDL * Below Detectable Limit 3 SEM = Scanning Electron Microscopy CONFIDENTIAL 003824 Bell Laboratories 600 Mountain Avenue Murray Hill, New Jersey 07974 Phone (201) 582-3000 January 17, 1978 Mr. V. B. McGuire New York Telephone 1095 Avenue of the Americas New York, N.Y. 10036 Dear Mr. McGuire: The two samples from the IBM plant in Endicott, New York you sent to Mr. J. M. Degen at AT&T Safety with your letter of December 12, 1977, have been analyzed for asbestos. Environmental Science Laboratories of Marlton, New Jersey found chrysotile asbestos In both samples using x-ray diffrac tion for the sample analysis. The results were as follows: Sample Description $ Chrysotile Asbestos Suspended Ceiling, Bldg. 14-3 25 Sprayed insulation above suspended ceiling, Buildg. 14-3 20 Any release of particles from these materials could cause an asbestos exposure. If you have any further questions about the analysis please give me a call. Sincerely Charles P. Lichtenwalner Copy to R. L. Beach - (AT&T) J. M. Degen }- (AT&TX{ THIS COPY ton U. J. Schreibcis R. W. Stone, K.Z - (AT&T G. M. Wilkening 003825 Bell Laboratories 600 Mountain Avenue Murray Hill, New Jersey 07974 Phone(201)582-3000 January 6, 1978 Mr. N. Wood New York Telephone 1095 Avenue of the Americas - Rm. New York, N.Y. 10036 2621 Dear Norm: The two air filter samples and one bulk sample from 24 Railroad Avenue, Greenwich, Connecticut have been analyzed for asbestos. The bulk sample was analyzed by x-ray diffraction which showed the sample was composed almost entirely of chrysotile asbestos. The two air filters were analyzed using the NI0SH specified method of counting all fibers greater than 5um in length using phase contrast microscopy. The results were as follows: Sample Air Volume Fibers/100 Fields Fibers/ml #1 (Basement) 135* 2 .02 #2 (Commercial 120 2 .02 Office) If you have any questions about the analysis, please do not hesitate to call. Sincerely MH-78P5-CPL-cj C. P. Lichtenwalner Copy to R. L. Beach }3- AT&T <6 THIS COPY FOR N. DeCapua - AT&T W. J. Schreibeis R. W. Stone - AT&T G. M. Wilkening CONFIDENTIAL 003826