Document mmkLxOYGeyDODLJOwGKoZjooO
Difr&tstv
Bell Laboratories
subject
Environmental Measurements of Potential Asbestos Exposure to New York Telephone Employees Working at Yankee Stadium, Bronx, New York
Case 48106-3 48087-1
date: May 12 1978 irom: V. R. Cohen
R. Deitchman
PLAINTIFF'S EXHIBIT
MEMORANDUM FOR RECORD
SWB-189
Potential asbestos exposure from flaking ceiling insul ation is a concern of New York Telephone employees working at Yankee Stadium, Bronx, New York. The entire clubhouse
ceiling of the stadium was sprayed with Insulating material
where New York Telephone employees have a storeroom, monitor the television - telephone interface, install and service telephones, and occasionally run cable for add itional telephone capacity. The Bell System Services Group at Bell Laboratories had performed an industrial hygiene evaluation on October 17, 1977.* Mr. V. B. McGuire, Supervisor-Safety of New York Telephone, requested two additional evaluation be made using more sensitive ana lytical techniques and during actual ball game conditions.
Summary
General environmental sampling and bulk sample collection was performed at Yankee Stadium, Bronx, New York on April 14, and 18, 1978 to evaluate New York Telephone employee exposure to asbestos. Analysis of the bulk spray insulation material indicates no asbestos fibers were present. Asbestos, in the platelet form, is present in the bulk material (10 percent from Cctober 1977 analysis) but, it is asbestos fibers that represent the health hazard. Air sampling with analysis by light and scanning electron microscopy indicate low levels of any fibers present with no detectable asbestos fibers.
Memorandum for Record: Environmental Measurements of Asbestos Exposure tc New York ToV rh'-no Employees '.Corking at. Yankee Stadium, Bronx, New Yor,:, November 10, 1977.
CONFIDENTIAL
003819
2
Re c oirnne ndat ions
The recommendations are:
1. New York Telephone Employees working in Yankee Stadium should be informed of the results of this investigation.
2. The management of Yankee Stadium should be informed of the analytical results of the flaking ceiling insulation in the clubhouse area.
Procedures
Asbestos samples were collected using the procedures outlined by the National Institute for Occupational Safety and Health (NIOSH) and the Occupational Safety and Health Administration (OSHA). The procedure involves collection of the fibers on a small filter cassette with later analysis using phase contrast microscopy. Additional parallel samples were collected in the same manner for further analysis by scanning electron microscopy. These filters were sealed and shipped to EMV Associate, Rockville, Maryland where the analysis was performed. The light microscopy simply identifies all fibers greater than 5 microns (pm) with an aspect ratio of 3:1. Using scan ning electron mici'oscopy with energy dispersive X-ray analysis, only asbestos fibers are counted.
Air was pulled through the filters using battery powdered sampling pumps manufactured by MSA and Bendix at 2.0 Jl/min. The pumps were calibrated using the soap bubble flowmeter technique.
Bulk samples were taken by removing a small section of the spray insulation and placing it into a envelope. This procedure was completed after environmental sampling so the disturbance of the ceiling insulation would not contaminate the general air sampling. The material was sealed and shipped to EMV Associates, Rockville, Maryland for analysis. The bulk material was analyzed by scanning electron microscopy (SEM) with energy dispersive x-ray analysis (EDXA). This analytical technique involves fiber identification by the scanning electron microscope then using the energy dispersive x-ray analyzer to determine composition for positive identification of fiber type.
CONFIDENTIAL
003820
3
Results
Table I presents the analysis of the bulk spray Insulation performed by EMV Associates. Their results indicate no asbestos fibers were found In the bulk material.
The results of bulk sample analysis performed last fall by ES Laboratories in Marlton, New Jersey showed some of the spray insulation to contain ten percent asbestos in the mineral phase. The SEM analysis by EMV Associates is designed to look more critically at fibers. Thus, the most probable cause of this difference in results (ten percent versus not detectable) is that the asbestos is in the platelet form and thus, non-fibrous. It is the asbestos fibers that present the significant health hazard. Another possible explanation of this difference is the composition of the spray Insulation is variable, but this possibility is unlikely since several samples from different locations were analyzed.
Airborne asbestos levels measured on April l1!, 1978 are shown in Table II. These measurements were made during a set-up day for the telephone-television Interface. The light microscopy result shows a small number of fibers are present but, using SEM asbestos fibers were detectable at the 0.005 fiber per cubic centimeter level.
Table III presents the airborne asbestos levels on April 18, 1978 during a ball game at Yankee Stadium. The results represent a similar situation as on April 14, 1978.
V. R. Cohen Industrial Hygienist
R. Deitchman Industrial Hygienist
Copy to
----------------- -
R. L. Beach - ftt?,tTM'co" F0Jm.
N. J. DeCapua - AT&T
V. B. McGuire - NY Tel
W. J. Srhreibeis - BTL
C. H. Steinmetz, M. D., - NY Tel
R. W. Stone, M. D., - AT&T
G. M. Wilkening - BTL
Wood - NY Tel
T" 2, 003821
Table I. Analysis of Bulk Spray Insulation Material Taken at Yankee Stadium, Bronx, New York.*
April 18, 1978
Location of Sample
Results of SEM*1 and EDXA2 Analysis of Sample
Room B173 ceiling
99-9% fibrous glass and
gypsum (no asbestos
fibers detected)
Room 524 ceiling
99`9* fibrous glass (no
asbestos fibers detected)
Hallway outside Room B173 celling
99.9% fibrous glass (no
asbestos fibers detected)
Floor outside Room B173
99.9% fibrous glass (no
asbestos fibers detected)
* Analysis performed by EMV Associates, Rockville, Maryland 1 Scanning electron microscopy 2 Energy dispersive x-ray analysis
CONFIDENTIAL
003822
-5-
Table II. Airborne Asbestos Levels Measured at Yankee Stadium, Bronx, New York, April 14, 1978
Location
Duration (minutes)
Concentration (fibers/cc)
Area Sample Room B174 (NY Tel A2AT Transmission Equipment Room)
Area Sample Room B174
129 129
0.08 BDL2 (0.005)
Area Sample -
Room B173 (NY Tel Supply Room)
115
BDL (0.005)
OSHA Standard
480
2.00
1 LM = Light Microscopy
2 BDL = Below Detectable Limit
3 SEM = Scanning Electron Microscopy
Method of Analysis
LM*1
SEM3 SEM
LM
CONFIDENTIAL
003823
-6-
Table III
Airborne Asbestos Levels Measured at Yankee Stadium, Bronx, New York
April 18, 1978
Location
Duration (minutes)
Area Sample Room B173 (NY Tel Supply Room)
255
Area Sample 0 Room B173
250
Area Sample -
Room B174 (NY Tel A2AT Transmission Equipment Room)
127
Area Sample Room B174
12H
Area Sample Room B174
140
Area Sample Hallway outside B173 on cable
rack
187
OSHA Standard
iJ8G
Concentration (fibers/cc) 0.07
BDL(0.005)2 0.07
BDL(0.005) BDL(0.005)
0.05
2.00
Method of Analysis
LM1
SEM3 LM
SEM SEM
LM
LM
1 LM = Light Microscopy 2 BDL * Below Detectable Limit 3 SEM = Scanning Electron Microscopy
CONFIDENTIAL
003824
Bell Laboratories
600 Mountain Avenue Murray Hill, New Jersey 07974 Phone (201) 582-3000
January 17, 1978
Mr. V. B. McGuire New York Telephone
1095 Avenue of the Americas New York, N.Y. 10036
Dear Mr. McGuire:
The two samples from the IBM plant in Endicott, New York you sent to Mr. J. M. Degen at AT&T Safety with your letter of December 12, 1977, have been analyzed for asbestos.
Environmental Science Laboratories of Marlton, New Jersey found chrysotile asbestos In both samples using x-ray diffrac tion for the sample analysis. The results were as follows:
Sample Description
$ Chrysotile Asbestos
Suspended Ceiling, Bldg. 14-3
25
Sprayed insulation above suspended ceiling, Buildg. 14-3
20
Any release of particles from these materials could cause an asbestos exposure.
If you have any further questions about the analysis please give me a call.
Sincerely
Charles P. Lichtenwalner
Copy to
R. L. Beach
- (AT&T)
J. M. Degen
}- (AT&TX{ THIS COPY ton
U. J. Schreibcis
R. W. Stone, K.Z - (AT&T
G. M. Wilkening
003825
Bell Laboratories
600 Mountain Avenue Murray Hill, New Jersey 07974 Phone(201)582-3000
January 6, 1978
Mr. N. Wood New York Telephone 1095 Avenue of the Americas - Rm. New York, N.Y. 10036
2621
Dear Norm:
The two air filter samples and one bulk sample from
24 Railroad Avenue, Greenwich, Connecticut have been analyzed for asbestos. The bulk sample was analyzed by
x-ray diffraction which showed the sample was composed almost entirely of chrysotile asbestos. The two air
filters were analyzed using the NI0SH specified method of counting all fibers greater than 5um in length using phase contrast microscopy. The results were as follows:
Sample
Air Volume
Fibers/100 Fields
Fibers/ml
#1 (Basement)
135*
2
.02
#2 (Commercial
120
2
.02
Office)
If you have any questions about the analysis, please do not hesitate to call.
Sincerely
MH-78P5-CPL-cj
C. P. Lichtenwalner
Copy to R. L. Beach
}3- AT&T <6 THIS COPY FOR
N. DeCapua
- AT&T
W. J. Schreibeis
R. W. Stone
- AT&T
G. M. Wilkening
CONFIDENTIAL
003826