Document mmNwKRX24rQ8QKpbgKbwKwv50
Fil* COO*
To** Name
S* C. Enders
From-- Nam*
L. Redmond
Subject:
Asbestos
Mg jChPoartmtnt
Friction Products
Department
Industrial Hygiene
Dust
Oivision
Chemical
Division
Personnel
Oat*
February ]7. 1972
Wam/OKico
CIMS Number
Trenton Chemical
Plftnt/OfliC*
CIMS Numenr
Highland Park
As requested by Mr. E. R. Lombard, samples were collected on February 7, 1972. to determine asbestos dust concentra
tions created by vacuum cleaning brake shoe grinding and packaging operations performed in the Friction Materials Building. Laboratory results reported as fiber counts are listed on the attached data sheet.
Discussion
The threshold limit value for asbestos dust was established at 5.0 fibers per milliliter greater than 5 microns in length.
As indicated on the data sheet, airborne asbestos dust con centrations ranged from 0.8 to 1.8 fibers per milliliter of air. Thus, a satisfactory condition was indicated. The utilization of the Parker Vac 35 vacuum cleaner did not create excessive dust concentrations at the time of the survey.
Attachment
cc: W. F. Bavinger
R. F. Bowers
W. T. Diehl
D. L. Eschelbach
R. T. Gaskill
W. L. Knapp. M.
T.
* j.
Lang
E. R. Lombard
R. D. McIntosh.
F. E. Repucci
J. G. Shepherd
N. A. Trombley
av m.*n
TV^*
Louis Redmond Industrial Hygienist
Data Sheet Trenton ChemicaL Friction Materials Building
V7 / 7 ^
Asbestos Dust Concentrations
-Location
Threshold limit value
Bay A-8. brake shoe grinder #5 breaching zone
Bay C-8 . packaging disc brakes. breathine zone
Fibers per MilliLiter of Air 5.0
1.8
1 .7
Operating Parker Vac 35 vacuum cleaner near weigh up anc automatic hoist areas, breaching zone.
0.8
The samples were obtained with vinyl mecricel filters and a Monetaire Pump.
m-my ta.-n