Document mmENKBQR1amaOED89gzxRDXdQ

, w 15- /P'//'&<( r-i. ty Pfizer Inc. 235 East 42nd Street : New York, NY 10017 : S hi Product: LlhESTOhE - LUCERO ; . VALLEY MSDS Noi MINERAC, / MINOIO Revisicn: 02 Date: June, 1998 Naticnal Paint and Coatings Association Hazardous Material Identification Syst&m-"' HEALTH HAZARD 1 - Slight FLAhTIABILITY HAZARD 0 - Minimal FEACTIVITY HAZARD 0 - hfinimal . FERSONAL PROTE---1'C1 TIO\ Nt, E - Glasses, Gloves, Dust , Resp SECTION I. MATERIA- IDGNTIFICATICN Tr^/I^tet^^N^ne* lilHESTONE Description: Limestone;, Calcium Carbonate 1 Other Designations: Vicron 10-20, Vicrcn 15-15, Vicron 25-11, Micron 31-6, Vicrcn , , 41-8, Vicrcn 45-3. Vicron SO, Vicron 200, Marblewhite 326, Marblewhite 325, .Marblewhite1 200, Marblewhite 125, Marblewhite 80, Marblewhite 30, Marblewhite -16+-4G, Calcium Meal 30, Calcium Grits #6, Calcium Brits #9. Calcium Grits,v#69, Pcultry^BlenU, Viroc #1, Viroc #2, Viroc #3, Glass Limestone, Vical 5075, Vical 2000, Vical 3005, Vical 4000, Vical 4030, Marblemix CPS: 1317-65-3 Chemical Naiie: CaCOs htanufactuner: Pfizer Inc. 235 East 42nd Street New York, NY 10017 ""J; `: V;V;`; -Phone: (619)- 248--7334, (Lucerne, : Valley, CA Plant) ' .SECTION II. INBFEDIENT5 AMD HAZARDS ^ Ingredient Ftame: Limestone . CAS Waiter: / Percsit: 1 Exposure Limits: -hr:'- 1317-65-3 /. hVh'h;:' ...he;.- ' - ;:`h , ACGIH TLV: lO.mg/M35, . 'i , Total Dust . ` - 0SHA..PEL:. 5 mg/M*. JV:.,'.'; Respirable : ------ ------------ PPm Chromium (VI) - less thap 0.1 ppm ::> Lead 1 - "4-6 ppm These levels are "typical" .quantities andf:mayvchange slightly wiU^i'dif.ferent, lots.. The term "less than" indicates ('that' the'hsubstance .was:, detected,, airojnL was , Page 1 IM3fiEDie<TS AND HAZARDS continues an page 2 Page 1 ' , -` V, ' ` (1 , ` ;, ^>4*' '< `i: i CHARDO 01692 Material Safety Data Sheet Pfizer Inc. 235 East 42nd Street New York, NY 10017 Product; '.LIMESTONE - LUCERNE VALLEY tSDS No: MINERAL / MIN010 Revision: 02 Date: -June, 1983 INGREDIENTS AND HAZARDS continued from page 1 less than the quantifiable limit. Limestone contains crystalline silica at levels above 0.17. but less than 17,, levels are "typical" and may change; slightly with different lots. These SECTION III. PHYSICAL DATA, Appearance & Odor: White powder, no odor Water solubility (X): Insoluble ........ Specific gravity (HaO=l): 2.6-2,8 j______________ SECTION IV. FIRE AND EXPLOSION DATA Flash Point (method): Non-flammable Extinguishing Media: Nan-flammable. As appropriate for surrounding combustibles. Lhusual fire or explosion hazards: None Special fire-fighting procedures: None SECTION V. REACTIVITY DATA Material is stable Hazardous polymerization will not occur Chemical incompatibilities: Reacts with acid to liberate cartoon dioxide gas. Conditions to anxoid: None known" Hazardaus decampasitiXTt Praducts: None SECTION VI. HEALTH HAZARD INFORMATION Summary of risks: Calcium Carbonate is !a "Nuisance Particulate". , They "have a long,:, history of little adverse effect on lungs and do not produce significant organic ' disease or toxic effect when exposures are kept under reasonable control" (ACGIH TLV definition). May cause eye and skin irritation from abrasion. . Primary entry route(s): Inhalation and ingestion. Acute effects: Abrassiveness may cause eye and skin irritation. Page 2 ------ HEALTH HAZARD ItEORMATICN continues an page 3 ------ Page 2 CHARDO 01693 Material Safety Data Sheet ;Pfizar Inc. 235 East 42nd Street , New York, NY 10017 , Product: LIMESTOH LUCERIsE VALLEY ,, M3DS fto: MINERAL f MIN01Q fWisicn: 02 Date: June, 1980 l-EPLTH HAZARD IInFCR-IATICN continued from page 2 Orel lie effect(s): No known chrcnic health effects. First aid: Eye contact: Flush eyes with plenty, of water for at least 15 minutes. . If irritation\persists, ;.seek medical,attention.1 ; Skin ccntact: Wash from skin with mild soap and water. Inflation: Remove,from the exposure,area; Ingestion: Ingestion should not cause any significant health 1 problems.' If a large amount'is ingested and if conscious, give lange quantities of water to induce "vomiting. Get medical attention. ,' ' Limestone is not listed as a carcinogen by :IARC, NTF, OSHA, Or.ACGlH. Crystalline "" 'silica which may be present in quantities less, than 17. has been reviewed by, IARC. I PRC found limited: evidence for, .carcinogenicity, of, .crystalline silica, in humans .and sufficient evidence in experimental animals.1 SECTION VII. SPILL, LEAK PND DISPOSAL PROCEDURES Spill / Leak procedures; Those involved in clean-up of spills should use respiratory protection for airborne dust. , Vacuum or scoop up spilled material for recovery or disposal, avoiding dusting conditions and usinq good ventilation. Wetting the spill with a water spray may help to keep the airborne dust levels down. Waste management / Disposal: Calcium Carbonate is not considered to be a RCRA hazardous waste and may be disposed in a site suitable for industrial wastes. Refer to any local, State or Federal regulations for specific disposal information. Far transportation emergencies, call 0-EMTREC, 24 hour information service, 1-000--424--9300. SECTION VIII. 5FECIAL PROTECTION INFCRhATICN Personal protective .equipnent: : Gaggles: .Safety glasses or dust-tight goggles. Gloves: Leather or rubber gloves. Page 3 ------ EFSEIAL H-UIECIICN INFORfPTIOl continues on page 4 ------ Page 3 CHARDO 01694 , ..... _ Material Safety Data Sheet Pfizer Inc. ' '235 East 42nd Street : New York, NY 10017 Pmtrti LIMESTETvE -LUCERNE ,, VALLEY f*EDS tos MlfvERPL / HXn6iO Revisions 02 __ Date: June, 1988 SPECIAL PROTECTION IWTttTICN/ta)tinued from 'pageVS;; Respirator: If exposure limits are exceeded.;,'dust respirator should be used. / ' ' ' Workplace considerations: Vtentilaticn: Provide adequate exhaust ventilation to meet TLV^n^irejinmts^^ exhaust filter system may1 "'be required to avoid environmental \ ; contamination. Safety"statimsi , An eyewash station should be iSble to the area of use. v. SECTION IX, SPEEIAL FSECALTTICNS , Other precautions: Good industrial hygiene practice requires that employee exposure tie maintained be lew the recommended TLV. This is/preferapl y achieved thrrugh -thev.; .provision "of adequate ventilation where necessaijy.vWhere dust- cannot; be ccntrolled this way, personal respiratory txhstaztim/shSild^ ....... ........lr Whf Class.:; Not, regulated. Pnepared/revised 'by: M. G. Larsen January, 1989 11 : #;,1 > jty ' 1V'1' The data1 and recommsndatians presented herein''"are based upon.:aireview,:of_^izer1 files, published MSDS's, and standard tpxica1ogical> reference sources. Pfizer Inc. makes no guarantee or warranty, either express or implied as to the accuracy or completeness of these data and recommendations. Page 4 End of M5DS WINOIO; Page 4 CHARDO 01695