730 CHAPTER 69 1962 Guide And Data Book Table 4 .... Refrigerant Line Capacities for Refrigerant 500 (Tons of Refrigeration Resulting in a Line Friction Drop Per 100 Ft Equiv. Pipe Length Corresponding to 2 F (AT) Change in Sat. Temp)' lino Size Typo l Copper, OO Suction tine** Svcfion Temp, F --40 -20 0 20 40 A7-0.58 AP-045 AT- 1.19 AT- F.A3 AP-2.T7 H 0.12 0.19 0.31 0.4S 0.7 M 0.32 0.52 0.82 1.29 2.0 iw 1.67 2.64 4.1 lH 1.17 1.72 3.02 4.77 7.4 iH 1.83 2.99 4.69 7.42 11.5 2H 3.81 6.24 9.8 15^5 24.0 2H 6.82 11.16 17.5 27.7 43.0 3H 18.2 28.6 45.1 70.0 3% 26.5 41.6 65.8 102.0 4 hi 23.6 38.7 60.9 96.2 149.0 SH 40.0 65.5 102.7 162.5 252.0 Discharge Lino** 4.59 Saturated Suction Temp -40 0.7 1.3 3.4 7.1 12.1 20.0 0 0.8 1.5 4.0 8.314.1 23.3 40 1.0 1.8 4.8 10.0 17.0 28.0 42.8 75.0 121.4 177.2 257.0 500 87.6 141.5 206.5 300.0 60.0 105.0 170.0 248.0 360.0 liquid Lines line Site Type l Copper, OO Condenser to Receiver Velocity = 100 fpm Kncnnnj fo System* Ar-I f AP-2.3 H H -K `IKH IK 2K 3H 3H 4H 2.3 10.8 23.2 120.5 156.5 2.8 5.1 13.6 28.0 50.0 80.0 165.0 295.0 475.0 NOTES: * (1) Basis of Table: 105 F Condensing Temp, 2 F AT per 100 ft Equivalent Length (except liquid Lines). (2) For other AT's and Equivalent Lengths, L, line Capacity (Tons) (100 Actual AT Loss Desired = Table Tons. X TT X Table AT Loss (3) For other Tons and Equivalent T-mgtha in a given pipe (Actual Tons \** Table Tons / (4) Values baaed on 105 F Condensing Temp. For capacities at other condensing temp, multiply table value by line capacity multiplier: Lane Suction Lines Discharge lines Condensing Temperature, F 80 90 100 105 110 120 1.16 1.09 1.03 1.00 0.97 0.91 0.84 0.90 0.96 1.00 1.04 1.12 (5) For the Equivalent Change in saturation temp for various 1in pressure drops in psi refer to Fig. 3. Fig. 3 .... Temp Equivalent (AT) of Pressure Drop (Refrigerant 500) (Text continued from p. 7S7) at --40 F suction with Refrigerant 12 the pressure drop equivalent to 2 F deg change in saturation temperature is about H psL This means that low temperature lines must be sired for a very low pressure drop or accept the penalty of higher equivalent temperature losses, with resultant loss in equipment capacity. Where a reduction in pipe sire is necessary to provide suf ficient gas velocity to entrain oil up vertical risers at partial loads, greater pressure drops will be imposed at full load. These can usually be compensated for by oversixing the hori zontal and downcomer lines to keep the total pressure drop within the desired limit. Discharge Lines. It is important to minimis the pressure loss in hot gas lines because losses in these lines increase the required compressor horsepower per ton of refrigeration and decrease the compressor capacity. It is usual practice not to exceed a pressure drop corresponding to one degree change in saturation temperature for ammonia and one or two de grees for other refrigerants. This is equal to about 3.3 psi for ammonia, 2 to 4 psi for Refrigerant 12 and 3 to 6 psi for Refrigerant 22. The effect of excessive suction and hot gas line pressure drops on compressor capacity and horsepower is illustrated uj Table I, using Refrigerant 12. Pressure drop is kept to a minimum by generously sizing the lines for low friction losses, but still making sure that refrigerant line velocities are sufficient to entrain and carry Refrigerant Piping Systems--General 731 Table 5 .... Refrigerant line Capacities for Refrigerant 717 (Ammonia) (Single or High Stage Applications) (7am of Smfrigetutiee m o Line Friction Drop par 100 ft CquircJestt Fipe length Commanding to I F (AT) Change in Saturation Tamp) tin# Size IFS SCH H 80 M 80 H 80 80 lK 40 iK 40 2 40 2H 3 4 5 6 8 10 12 40 40 40 40 40 40 40 ID -40 AP-0J2 3.24 4.83 9.34 15.0 26.9 56.1 102.0 160.0 338.0 605.0 975.0 Suction Lows* Suction Temperature F -20 AP-0-52 0 AP *0.78 20 AP-1.08 2.11 5.57 8-75 16.4 26.0 46.0 94.5 172.0 280.0 570.0 1030.0 1660.0 3.46 8.90 13-70 26.2 42.2 73.9 151.0 272.0 445.0 908.0 1640.0 2640.0 2.58 5.14 13.4 20.2 39.4 62.5 111.0 226.0 408.0 662.0 1355.0 2430.0 3940.0 40 AP-I.49 3.75 7.50 19.4 29.4 . 57.3 91.2 162.0 327.0 592.0 958.0 1960.0 3555.0 5680.0 Discharge lines* AP-3J liquid Lines line Size IFS SCH Condenser to Roceiros Velocity =100 fpm AP-3.3 3.63 7.98 15.9 41.2 57.5 118.9 187.2 338.2 676.0 1228.0 1986.0 4120.0 K K IK IK 2 2H 3 4 5 6 8 10 12 80 80 80 40 40 40 40 40 ^40 40 40 40 40 ID 13.5 24.9 41.5 86.2 117.2 193.5 276.0 425.0 736.0 29.7 66.7 130.0 281.0 439.0 1004.0 1599.0 2341.0 5750.0 NOTES: * (1) Baas of Table: 100 F Condensing Temperature, IF AT per 100 It Equivalent Length. Discharge and liquid Lines baaed on 0 F Suction. (2) For other aT's and Equivalent T^ngthn, L, line Capacity (Tons) _ ., _ / 100 Actual AT Loss Desired \*-M V L, Table AT Loss / (3) For other Tons and Equivalent Lengths in a given pipe L, t;/ Actual Tons \1 AT - Table AT X 100 XV Table Tons / (4) Values baaed on 100 F condensing temp. For capacities at other condensing temp, multiply table value by line capacity multiplier: line Suction Lines Discharge Lines Condensmg-Temperature, F 70 80 90 100 1.0 1.0 1.0 1.0 0.70 0.80 0.90 1.0 (5) For the Equivalent Change in saturation temp for various tine pressure drops in psi, refer to Fig. 4. (6) Tabulated data developed from ARI data.1 Fig. 4 .... Temperature Equivalent (AT) of _ Pressure Drop (Ammonia) oil along at all loading conditions (except for ammonia sys tems). Basis of Refrigerant Line Capacity Tables Tables 2 to 6 show capacities of refrigerant lines for am monia and Refrigerants 12, 22 and 500 at specific pressure drops. For ammonia, the tables are based on the tons of refrigera tion capacity of a line resulting in a line friction drop per 100 ft of equivalent pipe length corresponding to 1 F deg (AT) change in saturation temperature. For the other refrigerants, the tables are based on a 2 F deg equivalent loss, except for liquid lines. Correction factors'are provided for sizing lines at other losses. (See Table 7.) Pressure drops have been given in terms of degrees because of the genera] acceptance of this convenient method of pipe sizing throughout the industry. The corresponding pressure drops in psi may be determined from Figs. 1 to 4, located' below the capacity tables. The refrigerant line capacity tables for ammonia, and Refrig erants It and tt single or high stage applications are taken from data of the Air-Conditioning and Refrigeration InstituteThey are based on calculations using the Weisbach-Darcyformula and Darcy friction factors from a Moody chart. Capacity tables for