Document mm6MNZeRV0ZqoYq1jX2wgejpJ
Insulation
United States Gypsum Company
General Offices: 300 W. Adams Street, Chicago, 111.
Batt
INSULATION PRODUCTS Decorative
. Structural
RED TOP* INSULATION WOOL
WEATHERWOOD TILE--Available in 12 X 12, 12 x 24, 16 x 16 and 16 x 32
inches in A and 1 inch thicknesses. Colors
are Blendtex (gray and tan blends) and Hilite (ivory).
Red Top Ball
RED TOP MINERAL WOOL BATTS
"k" Valve .27 Btu's
Made for standard (16 in. or 24 in. O.C.) framing in two thicknesses, Medium (Approx. 2 in.) and Thick (Approx. 3 in.). Lengths are either 24 in. or 48 in. Batts are provided with an efficient vapor barrier paper providing nailing flanges for easy application. Adequately packed to insure material will arrive at the job in good condition.
WEATHERWOOD PANELTILE-- Hilite color available in 12 x 24 and 16 x 32 inches in inch thickness. Blentex colors available in 12 x 24 and 16 x 32 inches. Tile sizes 12 x 24 and 16 x 32 inches can be
mill cross scored to represent A inch Tile
Dimensions. All tile have fitted edges.
Structural
Decorative
Decorative
WEATHERWOOD* PLANK--Manu factured in widths of 8, JO, 12 and 16 inches and in lengths 6, 8, 10 and 12 feet--
inch thick. The fitted edges (see cut) conceal nails and seal against dust and air infiltration. WEATHERWOOD Plank is made in Blendtex (gray and tan blends) and Hilite (ivory) colors. When combined in variations of shades and width, Weatherwood Plank produces maximum values in both insulation and decoration.
WEATHERWOOD SHEATHING-- Asphalt coated. 2 feet x 8 feet x inches thick, with tongue and grooved long edges for horizontal application. Also available in 4 x 8, 4 x 9, 4 x 10 and 4 x 12
feet in either A inch or 25^2 inches thick
ness with square edges for vertical ap plication.
WEATHERWOOD BUILDING BOARD--4 feet wide, made in lengths
6, 7, 8, 9, 10 and 12 feet, A, and 1 inch
thick in either ivory- or gray tan colors. Applied by nailing; effectively insulates, strengthens and decorates.
WEATHERWOOD INSULATING
LATH--18 x 48 inches x A and A inch
thick with V joint on long edges. Gives an excellent plaster bond and also acts as a cushion for plaster with sound deadening qualities.
Tile and Plank Fitted Edge Reg. U. S. Pat. Off.
Heat Loss Factors
The heat loss factors shown on the opposite page indicate the comparative in sulation value of various insulating treat ments included in common construction systems.
United States Gypsum Company
Insulation
NOTE: These figures apply to 1 story buildings. To get figures for 2.story homes add 20 per cent to the values below for the wall constructions and divide by one*half for floor and ceiling constructions- It i9 important to use correct factor due to variations in the ratio of wall and window areas.
WALLS
Basie Construction--Frame Wood Siding Wood Sheathing 2 * 4's Rocklath & Plaster
No Wool Adding Red Between Top Wool
Studs r 2' 3'
Basic Construction Substituting in Above Basic Const. a. *3' WW Sheathing b. JA' WW Plaster Base c.(J#WW Plaster Base <L I' WW Plaster Base e. *3fj' WW Sheathing and
/,' WW Plaster Base f. <Am WW Bldg. BdM THe or
g. Vf Bldg. Bd.. or Tile n. Gyplap Sheathing L Va* Sheetrock j. Cypiap Sheathing and
Vi* Sheetrock
.248 .120 .083 .064
.186 .183 .157 .143
105 .076 .059 ,101 .076 .059 .094 .069 .055 .088 .067 .054
.147 .090 .068 .054
.187 .160 .310 .260
.104 .077 .059
.095 ,07(1 056 135 .09(1 .068
.IB .085 .064
.330 .136 .091 .069
WALLS
Bask Construction--Brick Veneer 4' Brick Wood Sheathing
Roeklath 6c Raster
No Wool Between
Studs
Adding Red Top Wool
1' 2* y
Bask Construction SubstitutinginAbove BasicConst. a.%'WW Sheathing b. WW Raster Base
WW Plaster Base <L 1' WVW Plhasstter BBawse e. WW Sheathing and
/,' WW Plaster Base
f'.* RaiJ^ BU` ^ T*le "
WW Bldg. Bd. or Tile Gyplap Sheathing 1. V2 Sheetrock j. Gyplap Sheathing and Vj Sheetrock
.270
.202 .200 .178 .157
.162
.215 .167 .350 .288
.368
.125 .085 .065
.111 .078 .061 .107 .077 .060 .102 ,073 .058 .094 .070 .055
.095 .070 .055
.112 ,079 .061 .104 .075 .059 .178 087 066 .130 .088 .066
.142 .093 .069
WALLS
Basic Construction 8' Brick Wall-4' Face Brick and 4' Common Brick--No interior finish
No Wool Adding Red Between Top Wool**
Studs*
Basic Construction
.500
Adduisto Above Baric Const.
a. .JA'Plaster
.480
b. Rocklath and Plaster (Furred) .300 .143 .093 .069
c. 'A' WW Plaster Base and Pi.
(Furred)
.220 .121 .084 .064
<L VS WW Plaster Base and PL
(Furred)
.190 .112 .079 .061
e. 1' WW Plaster Base and PL (Furred)
.160 .101 .073 .058
f. ^WW Bldg. Bd.. Tile or
.230 .124 .085 .065
g. ^WW Bldg. B<L. Tile or
.200 .115
062
h. 1' WW Bd., Plank or TOe
.170 .104 .075 .059
i. Vi# Sheetrock Furred
.320 .146 .095 .070
*Based on Furring Strip **Based on Full Dimension
WALLS Basie Construction--Plywood Rywood on Wood Studs Va' Outride--'A' Inside with one Air Space Over %'
No Wool Adding Red Between Top Wool
yStuds 1' 2'
Basic Construction
SubstitutinginAboveBaric Const a. JWW Bldg. Bd. TOe or
b. 3/4' WW Bldg. Bd. or Tile e. 1' WW Bldg. Bd. or Tile d. 3/a' Sheetrock e. Yi* Sheetrock f. Adding to bask construction
*56' WW Sheathing
.431 .151 .095 .074
.275 .230 .196 .430 .413
.126 .087 .065 .115 .081 .062 .106 .076 .060 .151 .095 .074 .148 .095 .074
.218 .113 .080 .061
CEILINGS
Bask Construction y^Rocklath and Vi"
No Wool Adding Red Between Top Wool
Joists I' r y
Basic Construction Substituting in AboveBasic Const. a. *A' WW Plaster Base & Plaster b. WW Plaster Base & Raster
c. I* WW Raster Base 6c Plaster d. W WW Bldg. Bd- Tile or
Plank. No Plaster e. /4' WW Bldg. Bd. or TOe
.Wf. l/2' W1 W Bldg. Bd. or Tile
tya' Sheetrock V2' Sheetrock
.610
.329 .290 .213
.356 .268 .220 .670 .635
.169 .116 .080
136 091 .068 .128 .087 .066 .110 .079 .061
.139 .092 .067 .124 .086 .065 .113 .080 .062 ,174 .118 .089 .170 .115 .079
Bask Cobstraction
Adding to Above Bask Const.
a. Vi* WW Bd. on bottom of joists___
b. Vi' WW Bd. on bottom erf joists
e. 1' WW Bd. on bottom of joists
FLOORS
Baric Construction Maple or Oak Flooring on Yellow Pine SubFlooring
No Wool Joists
Adding Red Top Wool
1' 2* y
.340 .138 .091 .068
.180 .102 .075 .059 .158 .094 .070 .055 .141 .088 .066 .053
Above calculations based on data from A.S.H.V.E. Guide--1942.
1271