Document mbzEELZdJwOzeO0GwMpED5qLd
35189
PLAINTIFF'S
I EXHIBIT CAP-69
July 7, 1964
J. M. Voith, A. G. Postfach 168 St. Poelten AUSTRIA
and
American Elin Corporation Eleven Broadway New York 4, New York
Gentlemen:
Subject: CAPCO Your Reference EV-2230 and Letter of June i, 1964
1. Blower for asbestos dust removal 7-1 /2 HP* 3450 RPM motor, 440 V, 3 Ph., 60 Cy., TEFC.
2. Bucket elevator leading to Kcllergang - 1-1/2 HP, 3 ph'., 60 Cy., 440 V, 1600 RPM, TEFC Frame 145 O. E. (Note: Actual HP 75, not 7.5 as per letter.)
3. Blower for transporting wet asbestos to silo - 20 HP, 3450 RPM, 440, V, 3 Ph., 60 Cy., TEFC motor.
.f
4. Belt conveyor for transporting asbestos from silo to scales, 1-1/2 HP. 3 Ph., 60 Cy., 440 V, 1800 RPM, TEFC Frame 145 O.E.
5. Redlers, transporting cement and silica dour to scales, 2 each 5 HP, 1800 RPM, TEFC. 3 Ph., 60 Cy., 440 V. Frame 215 G.E.
6. Pressure water pumps for the pipe machine, 2 each 40 HP, TEFC, 440 V, 3 Ph., 60 Cy., 3410 RPM, Frame 364VS G.E.
HER 0009540
-2 Item it question: Will it bo O.K. to pipe discharge of blower for transporting asbestos back to air intake at double screw feederf thus making a closed system of the fibre transporting circuit? Your opinion on this question will be appreciated.
Sincerely yours S. D. Weaver
HER 0009541