Document mbjdmdeRm9JODejxrgaQMNRmg

Heating Systems lafenfc^-iron UfilL-fflclAIN CQmPANY General Sales Office: Michigan City, Indiana Distributors in all principal cities WEIL-McLAIN CAST IRON OIL-FIRED BOILERS HR Heavy Duty Boilers for horizontal rotary burners Special steel front plate and section sim plify rotary burner installation. Large fire box volume develops better combus tion conditions--high base eliminates., high brick foundation. These boilers are also available as all-fuel units. Load range: steam 2,700-12,270 sq ft; water 4,450-19,630 sq ft. BOILER FOR OIL AND OIL HEATING UNITS Designed specifically for efficient oil burning. Long flue travel extracts maxi mum heat. I=B=R rated, ASMB con structed. Available in residential sizes as complete package units for forced hot water systems. Load range: Steam 285-3,400 sq ft; water 525-5,505 sq ft. WEH-McLAIN CAST IRON GAS-FIRED BOILERS A complete line of jacketed gas-fired boilers for residential, commercial and industrial applications. Cast iron construction for long life. Special design features assure efficient fuel com bustion--longer fire travel through finned flues permits maxi mum heat absorption. A.G.A. approved for natural, mixed, manufactured or liquefied petroleum gases--ASME construc ted. Load range: steam 260-12,950 sq ft; water 300-20,720 sq ft. Type J Gas Boiler Weil-McLain Snug Cast Iron Baseboards and Radiation Snug Cast Iron Baseboard Panels provide a balanced combina tion of radiant convected heat which assures uniform tempera ture from floor to ceiling. Available in two heights--71/\ in. x Snug Baseboard Panel 2% in. and 9jS in. x 2%[ in. Complete line of metal finishing accessories. Solray Cabinet Radiators have attractive, easily cleaned cabinet top. Large wa terways store heat for release when burner shuts off. , Raydiant Recessed Radiators are designed exclusively for recessing virtually iius in the wall--completely unobtrusive. Junior Radiators offer modern slender-tube design--can be installed in open rece if desired.. 356 iJM Aldrich Company ll 121 E. Williams St., Wyoming, Illinois Boiler-Burner Units, Domestic and Commercial Oil Burners The Aldrich line of vertical firetube steel boiler-burner units are ASME con structed and stamped, SBI rated and listed in rating book of Mechanical Con tractors Association. The Series, "D" units are available in ten sizes for hot water heating, steam heating and hot water supply--oil or gas fired. Boiler shipped with round jacket, insulation, flue baffles, combustion chamber and tankless coil (if required) factory in stalled. Burner, trim and controls packed in carton. The Aldrich Series "C"--Gulf Stream boilers are available in five sizes from 495 to 1260 sq ft water for hot water heating and hot water supply--oil or gas fired. The packaged units are furnished completely erected, pre-wired with equipment installed. Aldrich boilers furnished as high deliverynDUhoono_mmi_tt__siwci_c_aa_!a_l_tr_eii_ennrvvhcnoieonpuanmept--raepatra+ltsii:)co--itnn,_.t_e_e__rf_fn_i_c_a_i_el_l_yn__tmgauaulnvdaWniezvceod are available in wide range of sizes with outputs from 118 to 950 gph 100F rise. The Model E oil burner (0.5-4.0 gph) is available for domestic use and Model DX (4.5-10.0 gph) and JU (8.0-19.0 gph) for commercial applications. "D" -------------------------- Boiler No. Net Rating SBJ Steam Sq Ft.................. Net Rating SBI Water Sq Ft................... Net Rating SBI Steam Btu/hr................ Net Rating SBI Water Btu/hr................ Gross Output--Btu/hr................................ Gross Input--Gas--Btu/hr........................ Firing Rate--Oil--gph................................. Tankless Coil Output--gpm................ Hot Water Heater (HSG) Output GPH D-1301D-16QID-22QI D-280 3|0 400) 55o| 700 77000 , 87000 .115000 144000 1.1 3H 126C 168000 189000 252000 315000 2.5 4 D-360 900 1620 216000 243000 324000 405000 3.0 5 1D-450)D'530 D-610 D-730 D-890 1100 1300 1500 1800 2200 1980, .2340 2700 3240 3960 264000 312000 360000 432000 528000 297000 396000, 495000 3.7 5 351000 468000 585000 4.3 | 405000 540000 675000 5.0 4860001 648000 810000 6.0 594000 792000 990000 7,3 @ 100 Rise (40-H0F).......................... Storage Capacity--Boiler Gal..................... Heating Surface--Sq Ft ............................ Number of Flue Tubes............ 135 28 191 16 300 385 475 73 94 98, 41 j 53 65 30| 34] 42 645 775 950 125 150 170 106 129 71 SERIES "G"--GLTLF STREAM SPECIFICATIONS Boiler No. Net Rating SBI Water Sq Ft............................ Net Rating SBI Btu/hr...................................... Gross Output Btu/hr............................................. Gross Input--Gas--Btu/hr.................................. Firing Rate--Oil--gph............................................ Tankless Coil Output--gpm.............................. HotWater Heater (HSG; Output GPH @ 100 Rise (4OM40*F)..................................................... Storage Capacity--Boiler--Gallons................... Heating Surface--Sq Ft....................................... - Number of Flue Tunes .................. C-10 C-12 C-14 C-20 C-25 i495 74000 99000 120000 1.0 3 580 87000 115000 132000 1.1 3 720 995 108000 149000 144000 ,198000 165000 250000 1.35 2.0 3 1260 ,189000 252000 320000 2.5 4 118 135 170 235' 300 19 16 20 23 19 20 29 24 20 31 32 32 39 41 32 357 Gulf Stream Package