Document mbjdmdeRm9JODejxrgaQMNRmg
Heating Systems lafenfc^-iron
UfilL-fflclAIN CQmPANY
General Sales Office: Michigan City, Indiana Distributors in all principal cities
WEIL-McLAIN CAST IRON OIL-FIRED BOILERS
HR Heavy Duty Boilers for horizontal rotary burners Special steel front plate and section sim plify rotary burner installation. Large fire box volume develops better combus tion conditions--high base eliminates., high brick foundation. These boilers are also available as all-fuel units.
Load range: steam 2,700-12,270 sq ft; water 4,450-19,630 sq ft.
BOILER FOR OIL AND OIL HEATING UNITS
Designed specifically for efficient oil burning. Long flue travel extracts maxi mum heat. I=B=R rated, ASMB con structed. Available in residential sizes as complete package units for forced hot water systems.
Load range: Steam 285-3,400 sq ft; water 525-5,505 sq ft.
WEH-McLAIN CAST IRON GAS-FIRED BOILERS
A complete line of jacketed gas-fired boilers for residential, commercial and industrial applications. Cast iron construction for long life. Special design features assure efficient fuel com bustion--longer fire travel through finned flues permits maxi mum heat absorption. A.G.A. approved for natural, mixed, manufactured or liquefied petroleum gases--ASME construc ted.
Load range: steam 260-12,950 sq ft; water 300-20,720 sq ft.
Type J Gas Boiler
Weil-McLain Snug Cast Iron Baseboards and Radiation
Snug Cast Iron Baseboard Panels provide a balanced combina
tion of radiant convected heat which assures uniform tempera
ture from floor to ceiling. Available in two heights--71/\ in. x
Snug Baseboard Panel 2% in. and 9jS in. x 2%[ in. Complete line of metal finishing accessories.
Solray Cabinet Radiators have attractive, easily cleaned cabinet top. Large wa
terways store heat for release when burner shuts off.
,
Raydiant Recessed Radiators are designed exclusively for recessing virtually iius
in the wall--completely unobtrusive. Junior Radiators offer modern slender-tube design--can be installed in open rece
if desired..
356
iJM
Aldrich Company ll
121 E. Williams St., Wyoming, Illinois
Boiler-Burner Units, Domestic and Commercial Oil Burners
The Aldrich line of vertical firetube steel boiler-burner units are ASME con structed and stamped, SBI rated and listed in rating book of Mechanical Con tractors Association. The Series, "D" units are available in ten sizes for hot water heating, steam heating and hot
water supply--oil or gas fired. Boiler shipped with round jacket, insulation, flue baffles, combustion chamber and
tankless coil (if required) factory in stalled. Burner, trim and controls packed in carton. The Aldrich Series "C"--Gulf Stream boilers are available in five sizes from 495 to 1260 sq ft water for hot water heating and hot water supply--oil or gas fired. The packaged units are furnished completely erected, pre-wired with equipment installed.
Aldrich boilers furnished as high deliverynDUhoono_mmi_tt__siwci_c_aa_!a_l_tr_eii_ennrvvhcnoieonpuanmept--raepatra+ltsii:)co--itnn,_.t_e_e__rf_fn_i_c_a_i_el_l_yn__tmgauaulnvdaWniezvceod
are available in wide range of sizes with outputs from 118 to 950 gph 100F rise. The Model E oil burner (0.5-4.0 gph) is available for domestic use and Model
DX (4.5-10.0 gph) and JU (8.0-19.0 gph) for commercial applications.
"D"
--------------------------
Boiler No. Net Rating SBJ Steam Sq Ft.................. Net Rating SBI Water Sq Ft................... Net Rating SBI Steam Btu/hr................
Net Rating SBI Water Btu/hr................ Gross Output--Btu/hr................................ Gross Input--Gas--Btu/hr........................
Firing Rate--Oil--gph................................. Tankless Coil Output--gpm................ Hot Water Heater (HSG) Output GPH
D-1301D-16QID-22QI D-280 3|0 400) 55o| 700
77000 , 87000 .115000 144000
1.1
3H
126C 168000 189000
252000 315000
2.5 4
D-360
900 1620 216000 243000 324000 405000 3.0
5
1D-450)D'530 D-610 D-730 D-890
1100 1300 1500 1800 2200
1980, .2340 2700 3240 3960
264000 312000 360000 432000 528000
297000 396000, 495000
3.7
5
351000
468000 585000
4.3 |
405000
540000 675000
5.0
4860001
648000 810000
6.0
594000
792000 990000
7,3
@ 100 Rise (40-H0F)..........................
Storage Capacity--Boiler Gal.....................
Heating Surface--Sq Ft ............................
Number of Flue Tubes............
135 28 191 16
300 385 475
73 94 98,
41 j 53
65
30| 34] 42
645 775 950 125 150 170
106 129 71
SERIES "G"--GLTLF STREAM SPECIFICATIONS
Boiler No. Net Rating SBI Water Sq Ft............................ Net Rating SBI Btu/hr...................................... Gross Output Btu/hr............................................. Gross Input--Gas--Btu/hr.................................. Firing Rate--Oil--gph............................................ Tankless Coil Output--gpm.............................. HotWater Heater (HSG; Output GPH @ 100
Rise (4OM40*F)..................................................... Storage Capacity--Boiler--Gallons................... Heating Surface--Sq Ft....................................... -
Number of Flue Tunes ..................
C-10 C-12 C-14 C-20 C-25
i495
74000
99000 120000
1.0 3
580 87000 115000
132000 1.1 3
720 995 108000 149000
144000 ,198000
165000 250000 1.35 2.0
3
1260 ,189000 252000 320000
2.5 4
118 135 170 235' 300
19 16 20
23 19 20
29 24 20
31 32
32
39 41
32
357
Gulf Stream Package