Document mZXpR3ZE4X8jNoz8xp40x04O

> < Vi. c y -/ Re s p iritor Commit tee 1 n dus t ria 1 Hy giene Commit tee April 23, 1979 1 RECEIVED l // APR 26 1979 ^r f I. MEDICAL DIVISION a y^ !J' < To: From: Resp iritor Coordina to rs D. T . Lefferts, Building \ V. 1 09 A ' f * . DISPOSABLE RESP1RATORS Since returning to Chambers Works, I have reviewed many respirator approval requests. Many have been written, but a few have been handled by telephone. More often than not, the request centered on the 3M No. 8710 disposable respirator. I believe some general c1 arification is in order. The 3M Company markets several NI OSH-approved disposable respira tors as weii as several resp i rucors not having N I 0 3H-a iua 1 . T:.e unapproved (net disapproved) respirators are for use for the comfort of the wearer. These unapproved respirators are for such applications as: Protection from angoyance from grass seeds, pollen, soap powder, blood, bacteria, hair, wood slivers, etc. Protection from annoyance from foul, vapors and gases encountered by morticians, stockyard workers, sewer and sanitation workers, etc. - -Protection from annoyance from "nuisance" or "inert" particulates at less than exposure limit concentrations. The NIOSH-approved No. 8710 respirator is approved for fiberous particulates and for particulates whi ch cause pneumoconiosis and for nuisance particulates. Some materials which are in these ap proval categories are: Silica Silicates (Talc, Kaolin, Bentonite, Fuller's Earth, Mica, Cement) Coal ' __G raohite i* Asbestos T --sucrose Diatomite, Tripoli, 617 DUP 0904982 121330 SC-DP-05885 April 23, 1979 Respirator Coordinators DISPOSABLE RESPIRATORS Starch . Titanium Dioxide Aiuminum Oxide The JK No. 8710 is not approved for toxic materials, carcinogens or irritants. For most dry particulates which do not fall in the approval for the No. 8710, the 3^ No. 9900 can be used. The No. 9900 has ap proval for toxic dusts which have exposure limits of not less than 0.05 mg/m3. In general, dusts which have not effect of causing pneumoconiosis 3M No. 9900. Of course, the No. cations of the No. 8710 as well. been judged to have the sole are the prime challenges of the __ 9900 can be used for all appli If protection from mists is required, the 3N No. 9910 is the approved disposable respirator. Neither the No. o7i0, No. 5900 nor No. 9310 is approved for yoie, vapors or fumes. This means, mists with significant vapor pres sure* (other than water) are not applicable. Examples of approved mists other than aqueous solutions are glycerine and polyglycols. I am continuing to review the usage of disposable respirators as well as the developing data on their applicability and will keep you up to date on these. DTI:amb DUP 0904983 121531