VCH QUESTIONNAIRE
Please fill out one questionnaire for each plant site where VCM is stored or loaded/unloaded in T/C's.
1. Size of storage vessels? *1^0(2) at-----------220-------------- cubic meters.
Anbient temperature between
2. Storage temperature?
5 and 30 decrees C
/--
C
3. Distance from tank(s) to nearest residence?
Nearest village or community?
2000meters
2000meters.
4. Does prevailing wind blow towards a residential area? yes_______ no X
5. Have you done any vapor cloud dispersion modeling? yes_______ no X
6. Does your plant have an emergency plan which includes notification or warning the local community? yes no x
7. Have you made any changes in your operation or procedures
- since the Bhopal incident?
yes y no
8. Tank safety features:
a. Is tank(s) diked?
yes x
no
b. If a spill occurs, does VCM collect under vessel or is it
directed away to a basin?
under x away
c. What special features does diked area or basin have?
hard surfaced
covered
foam generationwater spray__x
pumpother (explain)
d. Is tank(s) sprinkled?
yes x no
e. Are flammable vapor detectors located where spill could
occur?
yes x no _______
f Are VCM area monitors located at tanks (for measuring ppm)?
yes X no ______
g. 4/85
Do level instruments have a redundant (second) backup?
yes X
no _______
CTL020071
Quest! nnair
Page 2
h. Do levels alarm at a control building which Is manned
around the clock?
yes ^
no
1. Does tank(s) have dual relief valves? yes
no X (single)
' j. Is there rupture discs under relief valve?
yes x
no _______
k. How is space between relief valve and rupture disc
monitored?
pressure gauge x open bleed valve
Pressure switch with alarm
other
l. Have you established a maximum fill level limit for your
tanks?
yes X
no _______
If yes, what is limit? ________ 80% (Note: Please state limit as percent of capacity)
m. Has tank(s) been internally inspected since original
installation date?
yes X no _______
If yes, please give age of tank and describe general
condition and anv problems (of a non-propriety nature) found . Tank was inspected in January 1985 at ten years of age with
no abnormal conditions being noted.
"
n. Any other safety features? Describe Each time the tank is filled the VCM is metered into the tank with a shutoff at a certain weight to be also a backup for the high level devices.
9. Pumps and lines:
a. Are bottom lines on tank equipped with remote operated
block valves (EBV's)?
yes x____ no
b. Do pumps have double seals?
yes X
no
c. Are pumps sealless?
yes
no ____
CTl020072
Questionnaire
Page 3
d. Are pumps all steel or wrought iron construction?
yes X
no____
e. Are pumps protected against a dead-headed condition (running with discharge valve blocked)? yes no___________ 2
If yes, how?__________ _____________________________________
f. Are pumps protected from a liquid blocked in condition? yes_______ no y
If yes, how? ______________________________________________
g. Are pipelines protected from liquid blocked-in condition?
yes x
no _______
If yes, how? Relief valve.__________ _______ ____
h. Are pipelines protected from hydraulic shock of sudden
valve closure?
yes_______ no x
i. What type gaskets are used in piping systems? Flat
asbestos type x retained type(such as flexltalllc) x
Uses both.
10. Tank car loading/unloading:
,,
Not applicable
a. Is the T/C area protected by water sprinkler? yes no
b. Are water monitor nozzles installed? yes no
c. Are flexible hoses used in the operation? yes no _______________
If yes, does the plant have a test program or procedure
for the hoses?
yes no
Please describe
CTL020073
Questionnaire
Page 4
d. Have you ever had a hose fail under VCM pressure? yes no _
e. How is overfilling prevented? Magnetic level float gauge. Load scale. Other
f . Is load/unload area diked for containing spillage? yes no
11. Do you ship or receive VCM by tank truck? yes
no X
12. Is the plant in the U.S .A.? X
outside the U.S.A.
Note:
This is being asked because U.S. Plants will have certain EPA required features whereas other countries may have different requirements. These distinctions will be used in the tabulations. Remember the survey is anonymous and no company will be identified.
CTL020074
DOW CHEMICAL U.S.A.
April 18, 1985
OYSTER CREEK DIVISION POST OFFICE BOX BB
FREEPORT, TEXAS 77541
C. A. Gellner Certain-Teed Corporation P. 0. Box 253 Sulphur, Louisiana 70663
VINYL CHLORIDE SAFETY ASSOCIATION QUESTIONNAIRE
Attached is a questionnaire concerning safety considerations in the storage and loading or unloading operations for vinyl chloride. Please have your plants fill in the data and return to me no later than Duly 15, 1985. From these I will work-up the data in tabular form to present at Tampa in September.
All companies who submit data will get a complete set of the survey results.
The questionnaires will be anonymous and no company names will be associated with the data. This will allow your company to determine how it compares to the overall industry with respect to VCM storage, loading and unloading.