Document mBO6EVq5OwkpdLd1EznRRYVNJ

Exhibit CRA-10 Hardbound Catalog, Crane Ltd. (UK), "Boilers, Radiators, and Radiator Accessories," - Catalogue No. 33, dated July 1938 * CRANE RADIATORS, BOILERS AND RADIATOR ACCESSORIES CATALOGUE No. 33 JULY 1938 CRANE LTD. Telephone ROYAL 1212 HEAD OFFICE 45-51 LEMAN STREET, E.l Telegrams CRANELON, TELEX LONDON LONDON SHOWROOMS: 118 WIGMORE STREET, W.l BRANCHES BIRMINGHAM, BRISTOL, GLASGOW, MANCHESTER WORKS IPSWICH CRANE CRANE FOREWORD HIS catalogue includes several additions to the range of heating Tequipment produced by Crane Ltd. The aerial photograph opposite depicts the Ipswich Factory where Crane Radiators, Boilers, Valves, Malleable Fittings, etc., are manufactured. This Factory contains one of the most up-to-date and efficient foundries for the manufacture of Boilers and Radiators. Although it is only eight years since the manufacture of these two pro ducts was commenced, after years of careful planning and research, it is noteworthy that in all quarters Crane Radiators and Boilers are accepted as at least equal in design and workmanship to any others obtainable. The aim of Crane Ltd. is to offer to their patrons heating goods which shall be a credit to their installations and provide an opportunity to stimulate sales by giving customers entirely new, outstandingly better product at no higher price. , CRANE BOILERS AND RADIATORS are not only employed by all the large Heating Engineers but are continually supplied to such public bodies as H.M. Office of Works, the Admiralty, the War Office, the London County Council, etc. In addition, some world-famous buildings have been, wholly or in part, equipped with Crane Radiators and Boilers. They are also regularly exported in large quantities to various parts of the British Empire and many foreign countries. In this catalogue is offered a complete range of heating specialties as commonly used in modern heating and hot water systems, but in some sections additional sizes and types are depicted in our General Catalogue which also includes goods in general use for Steam, Sanitary, Gas and Oil pipelines. ' ORDERS AND ENQUIRIES for prices or technical information should be addressed to Head Office, 45-51 Leman Street, London, E.l, rather than to the Factory, which involves delay. 3 CRANE CRANE RADIATORS HERE are sound reasons for the widespread acceptance that has Tbeen accorded Crane Radiators by Architects and Engineers. Amongst these reasons, the following SEVEN are especially noteworthy:-- I. The provision of the Crane patented deflecting Shield. 2. Strength, due to adequate and even metal thickness, solid metal feet, adequate sized nipples, etc. 3. Maximum radiant heat output, owing to the scientific design of the section of the waterway. 4. Conservative heating surface ratings and transmission ratings. 5. Standardised and easily remembered dimensions making for convenience and time saving by both designers and erectors. 4. High legs as Standard allowing adequate space beneath radiator for cleaning and sufficient height to connect to valves with ease. 7. Hospital Radiators and supports that are outstandingly "easy- clean" and smoothly cast. In addition to the foregoing the following details of the manufacturing processes demonstrate the extreme care that is taken to provide the best possible Radiator:-- MACHINING. Sections are machined on specially designed patented tapping and screwing machines which bore, screw and face both sides of the section at one set-up, thus ensuring perfect alignment. TESTING. Not only is every section tested to 100 lbs. pressure before machining, but the assembled Radiator is likewise tested to the same pressure. Certificates of Test can be furnished if desired. WASHING. Every Crane Radiator is washed internally and externally in boiling water before painting in order to remove all grease, sand and other impurities which would not only spoil the appearance but injure Valves, Traps and other Fittings in the pipe line. PAINTING. Crane Radiators are painted before leaving the factory with an exclusively developed paint capable of withstanding high tem peratures without deteriorating, and also serving as an excellent priming coat to all the usual forms of decoration. Often one coat of Decorator's paint can be saved by the use of Crane Radiators having this factory grey primary paint. 4 fry'" CRANE l Pattern AS c d* E Heating Water Maximum Content size 6.T.U. G Surface lbs. Tappings Trans, per per per top and sq. ft. section sq. ft. bottom 100" Diff. 2 Column .. 18 24 30 15* 12* 21* I8| 27* 24* 4 i- 2* 2* 7 i* i* 185 4 Column .. 18 24 30 36 15* 12* 21* 18* 27* 24* 33* 30* 4 I* 2* 5* 2* 2* 7 i* 170 6 Column .. 18 15* 12* 24 21* 18* 2* 3* 30 27* 24* 4 - 8* 2* 4* 7 i* 160 36 33* 30* 5 Window .. 13 n* 8* 3 Hospital.. 18 15* 12* 3 13* 2* 2* a 24 21* 18* 4 3 2 1 8 1-2 i* 158 1 185 30 27* 24* 5* Hospital 18 15* 12* i* i* 24 21* 18* 30 27* 24* 4 5* 2* 2 2* 1-5 i* 158 36 33* 30* 3 7* Hospital 18 15* 12* i* Wall 24 30 36 .. 18 21* 18* 27* 24* 33* 30* 16 4 2* 7* 2* 1-6 3* 5 i* 151 i 24 -- 22 -- 2 16 6* 7 1 30 28 8* Concealed -- II 8* ___ 3* 2 i* 7 1 Copper .. 24 21* 18* 3 171 ___ 30 27* 24* 4 5* 2 2* 1-3 36 33* 30* 2 1 136 * All " Pall Mall " Radiators excepting 2 Col., and Hospital, excepting 3 in. wide can be supplied with 6 in. high legs. The STANDARDISATION of the dimensions of Crane Radiators will be noted from the above, simplifying labour in the office, and on the job. All kinds and heights of radiators (excepting Window), dimension D is the same. All kinds and heights of " Pall Mall *' Radiators, dimension G is the same. All internal nipples are I* in. size, excepting for Wall, 3 in. Hospital, Copper Radiators and Concealed Radiators, which have I in. nipples. All outside tappings are right-hand pipe thread. Inside threads, flow end section, are right-hand for " Pall Mall " and Hospital, and left-hand for Wall. Inside threads, return end section, are left-hand for "Pall Mall" and Hospital, and right-hand for Wall. Concealed Radiators may be either. Air Vent, or Airlet Plug, is situated on return end section. 5 i L. CRANE THE TWO COLUMN For Corridors and Bedrooms, or wherever radiators of only a small heating surface are required, the Two-column " Pall Mall " Radiator will be found most suitable. The Two-column is also suitable where even distribution of heat is to be obtained by means of long Radiators, and can be supplied without feet for sup porting on Wall Brackets. i I i I "PALL MALL" FOR WATER OR STEAM f 6 L THE TWO-COLUMN, 2i- in. wide CRANE Number of Sections 4 5 6 7 8 9 10 II 12 13 14 15 16 17 18 19 20 2! 22 23 24 25 Length, 2* in. per section 9 ii* 13* 15* 18 20* 22* 24* 27 29* 31* 33$ 36 38* 40j 42* 45 47* 49* 51* 54 56* 30in. Height 1$ $q. ft. per section Heating Surface PRICE C s. d. 5* 10 2 * 12 8 8 15 2 9* 17 9 10* i 0 3 12 1 2 10 13* 1 5 4 14* 1 7 ii 16 i 10 5 17* 1 12 II 18* 1 15 6 20 1 18 0 21* 2 0 7 22* 2 3 1 24 2 5 7 25* 2 8 2 26* 2 10 8 28 2 13 3 29* 2 15 9 30* 2 18 4 32 3 0 10 33* 3 3 4 24-/n. Height I sq. ft. per section Heating Surface PRICE s. d. 4 7 II 5 9 II 6 M II 7 13 10 8 15 10 9 17 10 10 19 10 II 1 1 9 12 1 3 9 13 1 5 9 14 7 9 15 I 9 8 16 1 II 8 17 I 13 8 18 1 15 8 19 17 7 20 i 19 7 21 2 1 7 22 2 3 7 23 2 5 6 24 2 7 6 25 2 9 6 Number of Sections *Lengtht 2 in. Per section 18-in. Height * sq. ft. per section Heating Surface PRICE s. d. Legless Radiators are 2J in. less in height than when with feet. 4 5 9 Hi 3 63 3* 7 10 6 13* 4* 9 5 7 15* 5* 10 II 8 9 18 20* 6 12 6 6* 14 1 10 22* 11 24* 12 27 7* 15 8 8* 17 2 9 18 9 13 29* 9* 0 4 14 31* 10* 1 II 15 33* II* 3 5 16 36 12 5 0 17 38* 12* 6 7 18 40* 13* I 8 2 19 42* 14* 9 8 20 21 45 47* 15 I II 3 15* I 12 10 22 49* 16* I 14 5 23 51* 17* I IS II 24 54 18 I 17 6 25 56* 18* I 19 I * Add I in. to length for bushings. Radiators are supplied for water unless ordered for steam. When ordered for steam, outlet bushing is supplied tapped eccentrically unless otherwise ordered. Radiators are fitted with Air Vent Plug unless ordered for steam. CRANE THE FOU R CO LUM N A radiator of graceful lines yet of sound and sturdy construction. When wall space and floor area call for a radiator neither too long nor too wide, the desired amount of heating surface is often best supplied by the Four-column " Pall Mall " Radiator. "PALL MALL" FOR WATER OR STEAM Four-column radiators can be supplied with 6 in. legs. Prices on page 32. 8 THE FOUR-COLUMN, 51 in. wide Number of Sections ^Length, 2J in. per section 36-in. Height sq. ft. per section Heating Surface PRICE s. d. 4 9 13* 1 14 5 Mi 16* I 68 6 13* 19* 1 12 0 7 15* 23* 1 17 4 8 18 26* 228 9 20* 280 10 22* 33 2 13 4 l( 24* 36* 2 18 7 12 27 39* 3 3 11 13 29* 42* 393 14 31* 46* 3 14 7 15 33* 49* 3 19 il 16 36 52* 453 17 38* 56* 4 10 7 18 40* 59* 4 15 M 19 42* 62* 513 20 45 66 5 6 7 21 47* 69* 5 II II 22 49* 72* 5 17 2 23 51* 75* 626 24 54 79* 6 7 tO 25 56* 82* 6 13 3 Number Sections Hengfh, 2* in. per section 24-in. Height 2-fo sq. ft. per section Heating Surface PRICE s. d. 4 9 8* 15 10 5 II* (1 (9 10 6 13* 13* 1 39 7 15* 15* 1 79 8 18 17* t It 8 9 20* 19* 1 15 7 (0 22* 22 1 19 7 II 24* 24* 236 12 27 26* 276 13 29* 28* 2 115 14 31* 30* 2 15 5 15 33* 33 2 19 3 16 36 35* 3 33 17 38* 37* 3 72 18 40* 39* 3(12 19 42* 41* 3 15 1 20 45 44 3 19 1 2( 47* 46* 430 22 49* 48* 470 23 51* 50* 4 10 II 24 54 52* 4 14 II 25 56* 55 4 18 10 CRANE 30-in. Height sq. ft. per section Heating Surface PRICE s. d. 10* 13* 16* 18* 21* 24* 27 29* 32* 35* 37* 4u-i% 43* 45* 48* 51* 54 56* 59* 61* 64* 67* 18 12 17 III 1 16 20 0 6 0 6 0 6 25 29 2 14 2 18 33 37 0 6 0 6 0 6 3 12 3 16 41 45 4 10 4 14 0 6 0 6 0 6 4 19 0 536 580 5 12 6 18-in. Height l sq. ft. per section Heating Surface PRICE s. d. 6 II 7 7* 14 6 9 17 4 10* 1 0 3 12 1 3 2 13* 1 6 1 15 1 8 II 16* 1 II 9 18 1 14 8 1?* 1 17 7 21 2 0 6 22* 2 3 4 24 2 6 3 25* 2 9 2 27 2 12 1 28* 2 14 II 30 2 17 10 31* 3 0 9 33 3 3 7 34* 3 6 6 36 3 9 5 37* 3 12 4 * Add I in. to length for bushings. Legless Radiators 2| in. less in height than when with feet. Radiators are supplied for water unless ordered for steam. When ordered for steam, outlet bushing is supplied tapped eccentrically unless otherwise instructed. Radiators are fitted with Air Vent Plug unless ordered for steam. 9 CRANE THE SIX COLUMN Only 8f inches wide, the Sixcolumn is a concentrated unit providing an unusual amount of heating surface per section. It fulfils the requirements of large rooms where available wall space is limited and unduly long or too many radiators are not desirable. PALL MALL" FOR WATER OR STEAM 10 THE SIX-COLUMN, 81 in. wide Number Sections *Length, 2 in. per section 36-m. Height 5 sq. ft. per section Heating Surface PRICE s. d. CRANE 30-/n. Height 4fly sq. ft. per section Heating Surface PRICE s. d. 4 9 20 1 12 4 1 74 5 nf 25 204 20* 1 14 2 6 13* 30 285 24* 2I0 7 15* 35 2 16 6 28* 2 7 10 8 18 40 347 32* 2 14 8 9 20* 45 3 12 8 36-& 316 10 22* 50 409 41 3 84 II 24} 55 4 8 10 45* 3 15 2 12 27 60 4 16 II 49* 420 13 29} 65 5 4 II 53* 4 8 10 14 31} 70 5 13 0 57* 4 15 8 15 33* 75 61 1 61* 5 26 16 36 80 692 65* 594 17 38* 85 6 17 3 69* 5 16 2 18 40* 90 754 73* 630 19 42} 95 7 13 5 77* 6 9 10 20 45 100 816 82 6 16 8 21 47} 105 897 86* 736 22 49} 110 8 17 8 90* 7 10 4 23 51} 115 959 94* 7 17 2 24 54 120 9 13 10 98* 840 25 56} 125 10 li 102* 8 (0 10 Number of Sections *Length 2* in. per section 24-/n Height 3-fly sq. ft. per section Heating Surface PRICE s. d. 18-in. Height 2-fa sq. ft. per section Heating Surface PRICE s. d. 4 9 12* 1 30 9* 17 9 5 II* 16 1 89 II* 1 22 6 13} 19* 1 14 6 13* 1 67 7 15} 22-fy 203 16* Ml 1 8 18 25* 260 18* 1 15 6 9 20} 28* 2 119 20* 1 19 II 10 22* 32 2 17 6 23 24 4 II 24} 35* 333 25* 289 12 27 390 27* 2 13 2 13 29* 41* 3 14 9 29* 2 17 7 14 31* 44* 406 32* 32 1 15 33* 48 463 34* 366 16 36 51* 4 12 0 36* 3 10 II 17 38* 54* 4 17 9 39* 3 15 4 18 40* 57* 5 36 3 19 9 19 42} 60* 593 43* 442 20 45 64 5 15 0 46 488 21 47} 67* 609 48* 4 13 1 22 49} 70* 666 50* 4 17 6 23 51} 73* 6 12 3 52* 5 20 24 54 76* 6 18 0 55* 5 64 25 56} 80 739 57* 5 10 10 * Add I in. to length for bushings. Legless Radiators 2f in. less in height than when with feet. Radiators are supplied for water unless ordered for steam. When ordered for steam, outlet bushing is supplied tapped eccentrically unless otherwise instructed. Radiators are fitted with Air Vent Plug unless ordered for steam. 11 CRANE Number of Sections 13-in. Height 2sq. ft. per section *Length, 2* in. per section Heating Surface PRICE s. d. 49 1A, 5 II* 13 I 10 1 6 13* 15* 1 16 2 7 I5i 18* 222 8 18 20* 283 9 20* 2 14 3 10 22* 26 3 0 A n 24J 28* 3 6A 12 27 31* 3 12 A 13 29* 33* 3 18 A !4 31* Jb-fV AA5 Number of Sections 13-m. Height 2-fr sq. ft. per section *Length, 2* in. per section Heating Surface PRICE s. d. 15 33* 39 A 10 5 16 36 41* A 16 6 17 38* 44* 526 18 40* 46* 586 19 42* 49* 5 14 6 20 45 52 6 0 6 21 47* 54* 667 22 49* 57* 6 12 7 23 51* 59* 6 18 7 24 54 62* 7A8 25 56* 65 7 10 8 * Add I in. to length for bushings. Radiators are supplied for water unless ordered for steam. When ordered for steam, outlet bushing is supplied tapped eccentrically unless otherwise instructed. Radiators are fitted with Air Vent Plug unless ordered for steam. CRANE BRACKETS and STAYS for "PALL MALL" RADIATORS Dimensions of Standard Brackets give I in. from back of radiator to finished wall surface. For Two-column Radiators. Brackets can also be supplied for I in. clearance. Orders should state if this last pattern is required. The illustration shows a Two-column "Pall Mall" Radiator supported on Wall Brackets. MEASUREMENTS AND PRICES. For Radiators Dimensions in inches PRICES Fig. 804 Fig. 805 Fig. 806 Fig. 808 A B C D E Bracket Bracket Top Stay Top Stay (build in) (screw on) (build in) (build in) Pall Mall 2-Col. ... 10 H 5 3i -19 -19 -17 -/ii* Pall Mall 4-Col. ... 13 5i 8s -19 -19 -{7 -/ii* Pall Mall 6-Col. ... 16 7i j II 5 1/1* I/I* -n -/H* Fig. 807 top stay with back plate for screwing to wall, price 7d. 13 CRANE THE CRANE INVISIBLE SHIELD Patent Number 354051 A SIMPLE DEVICE THAT PROTECTS WALLS AND HANGINGS. Front view showing how Crane Invisible Deflecting Shields are inserted. ! The Invisible Shield consists of pressed steel plates which slide down specially cast grooves in the sections and form a metal curtain that fits snugly between each column, from top hub to the bottom of the castings, on the side of the radiator next to the wall; it makes little change in the radiator's appearance yet greatly increases its effectiveness. Instead of permitting the heated air to rise straight up, it deflects it outward into the room, where most required. Thus it protects walls and plaster, largely eliminates blackened areas above a radiator, and guards against damage to draperies. Furthermore, the Crane Shield has the notable effect of increasing the temperature of the air from the floor line up to about five feet above the floor, between which levels the heat is most required. This increase of temperature is gained at the expense of the temperature of the air below the ceiling. Therefore, for the same conditions of comfort to the occu pants of the room, there is an appreciable saving in fuel consumption. Every Pall Mall radiator, except the Two-column, can be equipped with the Invisible Shield at the slight additional cost of 3d. per radiator section for " Pall Mall " Radiators. In the case of Radiators fitted with Deflecting Shields and required with blind nipple, customers should state whether flow is at right- or left-hand when radiator is in position. Deflecting Shields should be ordered at the same time as the Radiators, and are fitted before despatch. : . 1 > t ' ' '. k F CRANE CRANE SHIELD AND BAFFLE PLATES Patent Number 363777 tI The Crane Shield'and Baffle fitted to a Radiator with a fresh air inlet is particularly adaptable to Office and School Buildings, especially as a means of tempering the incoming air to rooms having a system of extract ventilation. By reason of the induced or "stack" effect, the efficiency of the radiator is increased. The baffle is less expensive than the old style baffle plates, and moreover does not destroy the graceful lines of the radiator, furthermore it increases the radiant heat value. The baffle is easily removed for cleaning if desired. Price 6|d. per radiator section for "Pall Mall" Radiators for both Shield and Baffle. Crane Shield and baffles should be ordered at the same time as the radiators, and are fitted before despatch. Cast Iron Plates for extending Shield and Baffles to floor line, where air inlet is through floor instead of wall, can be supplied on request for "Pall Mall" Radiators only. Price -/4 one side per section, -/6 two sides per section. 15 L CRANE THE HOSPITAL RADIATOR 3" WIDE The 3-in.-wide Crane Hospital Radiator is designed for Schools, Hospitals and other situations where easy-clean Radiators of narrow width are desired. The air space between the Sec tions is I in. and the thickness of the Section I in. Supplied with feet (standard height only) or without feet. 16 ia pi . -3'u-j3t- 24iurn i CRANE THE HOSPITAL RADIATOR, 3 in. wide Number of Sections *Length, 2 in. per section 30-/n. Height sq. ft. per section Heating Surface PRICE s> d. 24-in. Height 1 sq. ft. per section Heating Surface PRICE s. d. 4 8 5* 10 0 4 82 5 10 6* 12 6 5 to 2 6 12 7* 15 0 6 12 2 7 14 9* 17 6 7 14 3 8 16 10* 1 00 8 16 3 9 18 II* 1 27 9 18 3 10 20 13 I 5 1 10 i 0 4 11 22 14* 1 77 II 1 24 12 24 15* 1 10 I 12 1 4 5 13 26 16* 1 12 7 13 1 65 14 28 18* 1 15 | 14 1 8 5 15 30 19* 1 17 7 15 I 10 6 16 32 ' 20* 20 1 16 i 12 6 17 34 22* 227 17 1 14 6 18 36 23* 25 1 18 i 16 7 19 38 24* 277 19 1 18 7 20 40 26 2 10 i 20 2 0 8 21 42 27* 2 12 7 21 228 22 44 28* 2 (5 1 22 2 4 8 23 46 29* 2 17 7 23 269 24 48 31* 30 | 24 2 8 9 25 50 32* 3 28 25 2 10 9 Number of Sections Length, 2 in. per section 18-in. Height i sq. ft. per section Heating surface PRICE s. d. 4 5 8 10 6 12 7 14 8 16 9 18 to 20 3 69 3* 8 5 4* 10 1 5* It 9 6 13 5 6* 15 I 7* 16 10 11 22 8* 18 6 12 24 9 101 13 26 9i 1 f 10 14 28 10* 1 3 6 15 30 Hi 1 5 2 16 32 12 1 6 10 . 17 34 12* 1 8 7 18 36 13* 1 10 3 19 38 14* i it n 20 40 15 1 13 7 21 42 15* 1 15 3 22 44 16* 1 IS II 23 46 17* 1 18 8 24 48 18 2 0 4 25 50 18* 2 2 0 Add I in. to length for bushings. Radiators are supplied for water unless ordered for steam. When ordered for steam, outlet bushing is supplied tapped eccentrically unless otherwise ordered. Radiators are fitted with Air Vent Plug unless ordered for steam. Legless Radiators are 2f in. less in height chan when with feet. 17 B i ( CRANE THE HOSPITAL RADIATOR 5r WIDE FOR WATER OR STEAM The Crane Hospital Radiator is designed for those situations where scrupulous cleanliness is desired. Both the contours and the smoothness of the castings render the Radiator perfectly easy to clean. The air space between sections is Ij- in. and the thickness of section If in. Supplied with or without feet. Hospital Radiators can be supplied with 6 in. legs. Prices on page 32. 18 CRANE THE HOSPITAL RADIATOR, 5? in. wide Number of Sections *Length, 2f in. per section 36-in. Height 3 sq. ft. per section Heating Surface PRICE s. d. 4 10* 12 i i 7 5 13* 15 1 6 II 6 15* 18 1 12 4 7 18* 21 1 17 9 8 21 24 2 3 1 9 23* 27 2 8 6 10 26* 30 2 13 II 1 i 28* 33 2 19 4 12 31* 36 3 4 8 13 34* 39 3 10 i 14 36i 42 3 15 6 15 39* 45 4 0 10 16 42 48 4 6 3 17 44* 51 4 It 8 18 47* 54 4 17 0 19 49f 57 5 2 5 20 52* 60 5 7 10 21 55* 63 5 13 2 22 57* 66 5 18 7 23 60* 69 6 4 0 24 63 72 6 9 4 25 65* 75 6 14 9 30-in. Height sq. ft. per section Heating Surface PRICE s. d. 10 19 3 12* 1 4 1 15 1 8 11 17* 1 13 9 20 1 18 6 22* 2 3 4 25 2 8 2 27* 2 13 0 30 2 17 10 32* 3 2 8 35 3 7 5 37* 3 12 3 40 3 17 1 42* 4 III 45 4 6 9 47* 4 116 50 4 16 4 52* 5 1 2 55 5 6 0 57* 5 10 10 60 5 15 7 62* 6 0 5 Number of Sections Length, 2* in. per section 24-in. Height 2 sq. ft. per section Heating Surface PRICE s. d. 18-in. Height l sq. ft. per section Heating Surface PRICE s. d. 4 10* 5 13* 6 15* 7 18* 8 21 9 23* 10 26* II 28* 12 ,, 31* 13 34* 14 36* 15 39* 16 42 17 44* 18 47* 19 49* 20 52* 21 55* 22 57* 23 60* 24 63 25 65* 8 16 3 6 13 5 10 ! 0 4 7* 16 10 12 1 4 5 9 1 02 14 1 8 5 10* 1 3 6 16 1 12 6 12 1 6 10 18 1 16 7 13* 1 10 3 20 2 0 8 15 1 13 7 22 2 4 8 16* 1 16 II 24 2 8 9 18 2 0 4 26 2 12 10 19* 2 3 8 28 2 16 II 21 2 7 0 30 3 0 n 22* 2 10 5 32 3 5 0 24 2 13 10 34 3 9 1 25* 2 17 2 36 3 13 2 27 3 0 7 38 3 17 2 28 3 3 11 40 4 I 3 30 3 7 3 42 4 5 A 31* 3 10 8 44 4 9 5 33 3 14 0 46 4 13 5 34* 3 17 4 48 4 17 6 36 4 0 8 50 5 I 7 37* 4 4 1 * Add lin. to length for bushings. Legless Radiators are 2J in. less in height than when with feet. Radiators are supplied for water unless ordered for steam. When ordered forsteam, outlet bushing is supplied tapped eccentrically unless otherwise instructed. Radiators are fitted with Air Vent Plug unless ordered for steam. 19 CRANE------------------------ THE HOSPITAL RADIATOR 7i" WIDE T FOR WATER OR STEAM Designed for situations where scrupulous cleanliness is desired, but the length of available space for the Radiator is limited. Both the contours and the smooth ness of the castings render the Radiator perfectly easy to clean. The air space between sections is If in. and the thickness of section If in. Supplied with or without feet. Hospital Radiators can be supplied with 6 in. legs. Prices on page 32. 20 JL CRANE THE HOSPITAL RADIATOR, 7i in. wide Number of Sections 4 s 6 7 8 9 10 II 12 13 14 J5 16 17 18 19 20 21 22 23 24 25 *Length, 2f in. per section 10} 13} 15} 18} 21 23} 26} 28} 31} 34} 36} 39} 42 44} 47} 49} 52} 55} 57} 60} 63 65} of Sections 4 5 6 7 8 9 10 n 12 13 14 15 16 17 18 J9 20 21 22 23 24 25 2} HI. per section 10} 13} 15} 18} 21 23} 26} 28} 31} 34} 36| 39} 42 44} 47* 49} 52} 55} 57} 60} 63 65} 36-in. Height 3-ft sq.ft, per section Heating Surface PRICE s. d. 14* 18* 1 67 1 13 3 22* 25* 29* 33* 37 1 19 II 266 2 13 2 2 19 10 365 40* 44* 48* 51* 55* 3 13 3 19 46 4 13 4 19 2 9 5 1 9 59* 62* 66* 70* 74 56 5 13 5 19 66 6 13 4 0 8 4 0 77* 81* 85* 88* 92* 6 19 7 763 7 12 M 7 19 7 863 24-in. Height 2-ny sq. ft. per section Heating Surface PRICE s. d. 9* 12 19 6 1 45 14* 16* 19* 21* 24 1 93 I 14 2 1 19 0 2 3 11 289 26* 28* 31* 33* 36 2 13 2 18 33 38 3 13 8 6 5 4 2 38* 40* 43* 45* 48 3 18 0 4 2 11 479 4 12 8 4 17 6 50* 52* 55* 57* 60 525 573 5 12 2 5 17 1 6 1 II 30-in. Height 3tV sq. ft. per section Heating Surface PRICE s. d. 12* 15* 1 3 II 1 9 10 18* 21* 24* 27* 31 1 15 10 2 1 10 279 2 13 9 2 19 9 34* 37* 40* 46* 359 3 118 3 J7 8 438 497 49* 52* 55* 58* 62 4 15 51 57 5 13 5 19 7 7 6 6 6 65* 68* 71* 74* 77* 655 6 115 6 17 5 734 794 l8-n. Height 1sq. ft. per section Heating Surface PRICE s. d. 7* 16 2 9 1 02 10* 12* 14* 16* 18 14 18 1 12 1 16 20 2 3 3 3 4 19* 21* 23* 25* 27 24 28 2 12 2 16 30 5 5 5 6 6 28* 30* 32* 34* 36 34 38 3 12 3 16 40 6 7 7 7 8 37* 39* 41* 43* 45 448 489 4 12 9 4 16 9 5 0 10 * Add 1 in. to length for bushings. Legless Radiators are in. less in height than when with feet. Radiators are supplied for water unless ordered for steam. When ordered for steam, outlet bushing is supplied tapped eccentrically unless otherwise instructed. Radiators are fitted with Air Vent Plug unless ordered for steam. 21 CRANE---------------------------------------------------------------------------------------------------------- BRACKETS and STAYS for HOSPITAL RADIATORS Registered Designs Nos. 772462, 772463 Hospital Radiators need Easyclean Brackets and Stays. These are available with Crane Hospital Radiators. Dimension "F" can be ad justed between 4| in. and 6 in. permitting Radiators to be fixed at any distance from wall between l in. and 3^ in. for the 3" wide, 2 in. and 3^ in. for the 5f in. wide, and between 2 in. and 3 in. for the 7^ in. wide Radiator. A Stay similar to Fig. 813 is supplied for screwing to wall to the fixed dimension "A": described_as Fig. 814. \jr=r> For Hospital Radiators 3 in. wide 5 in. wide 7* in. wide Dimensions in inches PRICES fi Fig. 809 Fig. 810 Fig. 81 i Fig. 812 Fig. 813 Fig. 814 A C Bracket Bracket Top Stoy Top Stay Top Stay Top Stay (build in) (screw on) (build in) (screw on) (build in) (screw on) 33 Mi 8j- -19 -19 1/3 1/3 -17 -17 a 13 91 -19 -19 1/5 1/5 -17 -17 5i 16 Hi l/li l/li 1/5 1/5 -17 -17 22 CRANE RADIATOR BRACKETS FOR H.M.O.W. AND COUNTY COUNCIL REQUIREMENTS ADJUSTABLE TOP PATTERN Fig. 825 Figs. 825/6 Top Brackets permit of an adjustment of one inch, both horizon tally and ver tically when fixing radia tors. Fig. 826 Type of Radiator Pall Mall, 2 Col. ... ,, ,, 4 .......... ,, ,, 6 ,, ... Hospital, 3" wide ,, sy ,, 7-g" ,, Space, Wall to back of Radiator 2" 2" 2" 2" 2" 2" Height from centre of Wall portion to centre of top hub x44|/""/ min., > I'*J144j1\'">" max. m 11 XX48 "" >> O~|'4LX8"" 4 > 14 > PRICE each 2/3 2/3 2/10 2/3 2/3 2/10 SUSPENDED ADJUSTABLE PATTERN Fig. 827 Fig. 827. Suspended Brackets permit considerable Radiator movement due to pipe work expansion. The vertical adjustment is 3" and the space from wall to back of Radiator is 2" for all types. PRICE Complete as illustrated ... 8/4 per set. For all types of Pall Mall and Hospital Radiators. The height and type of Radiator and centres of build-in portion must be stated when ordering. See page 25 for adjustable Brackets for Wall Radiators. 23 CRANE THE WALL RADIATOR FOR WATER OR STEAM Number *Lengths of 16 in. Sections per section 30-in. Height 8* sq. ft. per section Heating PRICE Surface s. d. 24-in. Height 6 sq. ft. per section Heating PRICE Surface s. d. 18-in. Height 5 sq. ft. per section Heating PRICE Surface s. d. 1 16 8* 15 II 6* 12 10 5 98 2 32 16* 1 | | 10 13* 1 5 8 10 19 3 3 48 24J 2 7 8 20 1 18 6 15 1 8 11 4 64 33 3 3 7 26f 2 II 5 20 1 18 7 5 81* 41* 3 19 6 33* 3 4 3 25 2 8 2 6 96J 49* 4 15 5 40 3 17 1 30 2 17 10 7 M 13* 57# 5 II 3 46* 4 9 II 35 3 7 5 8 |-I28| 66 6 7 2 53* 5 2 9 40 3 17 1 9 145* 74* 7 3 1 60 5 15 7 45 4 6 9 10 f!6l* 82* 7 19 0 66| 6 8 6 50 4 16 4 * Add I in. for plugs and bushings, f Includes hexagon nipples. Crane Wall Radiators are assembled with I in. right and left-hand screwed nipples, and are despatched assembled up to four sections. Radiators of five sections and over are despatched in two or more portions, together with the necessary hexagon right and left nipples for assembly. Height ................................................................30 Distance between centres of top and bottom tappings................................................................ 27-ff Width ................................................................ 2 ins. 24 21-rf 2 ins. 18 15-H 2 All Radiators are fitted with Air Vent Plugs unless ordered for steam. 24 i j------ WALL RADIATOR BRACKETS CRANE "'f f Prices of Brackets for Wall Radiators, all heights:-- Fig. 800 Top Stays, screw on ... -/4j each Fig. 806 ,, ,, build-in............... ~/7 ,, Fig. 807 ,, ,, screw on ... -/7 ,, Fig. 801 Bottom Brackets, screw on -/5-j ,, Fig. 802 Brackets, built-in ........ --/I0 ,, Fig. 803 Two-piece Brackets, screw on -/8 per pair Fig. 820 Adjustable Top Bracket, screw on........................... -/!! each One section radiators can be supported with one pair of Fig. 803 Brackets. Two Bottom Brackets, Fig. 801, and one Top Stay, Fig. 800, are advised for Radiators up to four sections in length, and three Brackets and two Top Stays for Radiators of five sections and longer. It will be noted that Fig. 800 Top Stay fits between the sections and is practi cally invisible when In position. Dimensions of all Brackets and Stays provide for 2 ins. from wall to centre of Radiator. Fig. 802 Brackets can be supplied for 2\" centre to special order, for use with Figs. 806 and 807 stays. Overall proj'ection of Radiator from wall, with standard fixing, 3 ins. 25 J CRANE CRANE CONCEALED RADIATOR (Patent applied for) RADIATOR IN CABINET with front removed HEATING SURFACE: 1 sq. ft. per section. LENGTH: 2" per section, plus I3 PRICE: 2/3 per sq. ft. SUPPORTING BRACKETS DIMENSIONS AND PRICES Enclosure Width A B c L H Fig- Fig- Fig. Fig. 990 *991 995 996 4" 3" 41' 3f 8i" I3F -19 -/I0 -19 -19 x" 4i" 4T 3" 6" 4r 8i" I3|" -19 -/I0 -19 -19 51" 41' A" 3" 8" X" I0i" 4f" I2i" -19 -/II l/li l/li r A" 3" 7r 5i" Hi" 4|" II" -19 I/- l/li l/li * For four standard width enclosures only. 26 CRANE CABINETS, FRONT PANELS & GRILLES CABINETS Complete enclosure with the front removable. Standard enclosure is furnished with open inlet and slotted outlet grille, but louvred or other alternative designs can be supplied. This simple metal cabinet, appropriately decorated, will harmonise with any decorative scheme. Made in four heights--18", 24", 30" and 36". Two widths--6" overall and 8". FRONT PANELS Number of Sections length of Radiator ins. Cabinets Overall Length Ins. Fronts and Grilles Recess Length Length of Front Ins. Ins. 6 13* 7 8 15* 17* 18* 9 10 19* 21* 22$ 19* 23* 24* 27* 11 12 23* 25* 26$ 13 14 27* 29* 30$ 15 31* 31* 35* 34* 16 33* 17 18 35* 37* 38* 19 20 39* 41* 42* 39* 43* 44* 47* 21 22 43* 45* 46* 23 24 47* 49* 50* 25 51* 51* 55* 54* 26 53* 27 28 55* 57* 58* 29 30 59* 61* 62* 59* 63* 65* It is recommended that the use of long cabinets (for Radiators longer than 24 sections) be avoided if possible. Removable metal front panel with open inlet and slotted outlet grille. Usually applied flush with plaster and made to over lap recess at top and sides and is provided with screw holes for securing to wood grounds. If opening is formed in wood skirting, lower edge is supplied plain. HEIGHTS Recess 18", 21", 24", 27", 30", 33", 36", 39". Front 19*", 22*", 25*", 28*", 31*", 34*", 37*", 40*". GRILLES The grille overlaps the outlet opening and is provided with screw holes for securing to wood grounds. Access doors furnished on application only and can be furnished at either or both ends of grille panel, Height--8". Lengths--As for fronts. NOTE. The Standard Sheet Metal Enclosures illustrated above are not an essential of the Crane Concealed Radiator, which admirably lends'itself to concealment behind marble, polished slate, plaster-board, plywood, etc. Prices on application. 27 x r CRANE CONCEALED RADIATOR Outputs in B.Th.U.s per hour with Gravity Hot Water at 160 F. Room temperature 65 F.* Number of Sections 6 7 8 9 10 M 12 13 14 i5 16 17 IB 19 20 21 22 23 24 25 26 27 28 29 30 Overall Length Inches 13* 15* 17* 19* 21* 23* 25* 27* 29* 31* 33* 35* 37* 39* 41* 43* 45* 47* 49* 51* 53* 55* 57* 59* 61* Heating Surface Actual 7* 8* 10 II* 12* 13* 15 16* 17* 18* 20 21* 22* 23* 25 26* 27* 28* 30 31* 32* 33* 35 36* 37* 4*" width enclosure 6" width enclosure 8 " width enclosure 9" width enclosure Height in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" 970 1135 1295 1460 1620 1780 1945 2105 2270 2430 2590 2755 2915 3080 3240 3400 3565 3725 3890 4050 4210 4375 4535 4700 4860 1060 1240 1415 1595 1770 1945 2125 2300 2480 2655 2830 3010 3185 3365 3540 3715 3895 4060 4240 4415 4590 4770 4945 5125 5300 1145 1335 1530 1720 1910 2100 2290 2485 2675 2865 3055 3245 3440 3630 3820 4010 4200 4395 4585 4775 4965 5155 5350 5540 5730 1230 1435 1640 1845 2050 2255 2460 2665 2870 3075 3280 3485 3690 3895 4100 4305 4510 4715 4920 5125 5330 5535 5740 5945 6150 1210 1415 1615 1820 2020 2220 2425 2625 2830 3030 3230 3435 3635 3840 4040 4240 4445 4645 4850 5050 5250 5455 5655 5860 6060 1310 1525 1745 I960 2180 2400 2615 2835 2050 3270 3490 3705 3925 4140 4360 4580 4795 5015 5230 5450 5670 5885 6105 6320 6540 1410 1645 1880 2115 2350 2585 2820 3055 3290 3525 3760 3995 4230 4465 4700 4935 5170 5405 5640 5875 6110 6345 6580 6815 7050 1490 1735 1985 2230 2480 2730 2975 3225 3470 3720 3970 4215 4465 4710 4960 5210 5455 5705 5950 6200 6450 6695 6945 7190 7440 1255 1465 1670 1880 2090 2300 2510 2715 2925 3135 3345 3555 3760 3970 4180 4390 4600 4805 5015 5225 5435 5645 5850 6060 6270 1360 1590 1815 2045 2270 2495 2725 2950 3180 3405 3630 3860 4085 4315 4540 4765 4995 5220 5450 5675 5900 6130 6355 6585 6810 1480 1730 1975 2225 2470 2715 2965 3210 3460 3705 3950 4200 4445 4695 4940 5185 5434 5680 5930 6175 6422 6670 6915 7165 7410 1585 1850 2110 2375 2640 2905 3170 3430 3695 3960 4225 4490 4750 5015 5280 5545 5810 6070 6335 6600 6865 7130 7390 7655 7920 1320 1540 1760 1980 2200 2420 2640 2860 3080 3300 3520 3740 3960 4180 4400 4620 4840 5060 5280 5500 5720 5940 6160 6380 6600 1450 1695 1935 2180 2420 2660 2905 3145 3390 3630 3870 4115 4355 4600 4840 5080 5325 5565 5810 6050 6290 6535 6775 7020 7260 1550 1805 2065 2320 2580 2840 3095 3355 3610 3870 4130 4385 4645 4900 5160 5420 5675 5935 6190 6450 6710 6965 7225 7480 7740 1620 1890 2160 2430 2700 2970 3240 3510 3780 4050 4320 4590 4860 5130 5400 5670 5940 6210 6480 6750 7020 7290 7560 7830 8100 * Increase by 6% for 60 F. room temperature. See separate Folder for Outputs at intermediate heights. CRANE CRANE CONCEALED RADIATOR Outputs in B.Th.U.s per hour with Accelerated Hot Water at 170 F. Room temperature 65 F.* Number of Sections 6 7 8 9 10 II 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 26 29 30 Overall Length Inches 13* 15* 17* 19* 21* 23* 25* 27* 29* 31* 33* 35* 37* 39* 41* 43* 45* 47* 49* 51* 53* 55* 57* 59* 61* Heating Surface Actual 7* 8* 10 II* 12* 13* 15 16* 17* 18* 20 21* 22* 23| 25 26* 27* 28* 30 31* 32* 33* 35 36* 37* 4*" width enclosure 6" width enclosure 8 ' width enclosure 9 " width enclosure -{eight in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" 1100 1280 1465 1645 1830 2015 2195 2380 2560 2745 2930 3110 3295 3475 3660 3845 4025 4210 4390 4575 4760 4940 5125 5305 5490 1195 1395 1590 1790 1990 2190 2390 2585 2785 2985 3185 3385 3580 3780 3980 4180 4380 4575 4775 4975 5175 5375 5570 5770 5970 1290 1505 1720 1935 2150 2365 2580 2795 3010 3225 3440 3655 3870 4085 4300 4515 4730 4945 5160 5375 5590 5805 6020 6235 6450 1385 1615 1850 2080 2310 2540 2770 3005 3235 3465 3695 3925 4160 4390 4620 4850 5080 5315 5545 5775 6005 6235 6470 6700 6930 1360 1590 1815 2045 2270 2495 2725 2950 3180 3405 3630 3660 4085 4315 4540 4765 4995 5220 5450 5675 5900 6130 6355 6585 6810 1470 1715 I960 2205 2450 2695 2940 3185 3430 3675 3920 4165 4410 4655 4900 5145 5390 5635 5880 6125 6370 6615 6860 7105 7350 1585 1850 2110 2375 2640 2905 3170 3430 3695 3960 4225 4490 4750 5015 5280 5545 5810 6070 6335 6600 6865 7130 7390 7655 7920 1675 1955 2230 2510 2790 3070 3350 3625 3905 4185 4465 4745 5020 5300 5580 5860 6140 6415 6695 6975 7255 7535 7810 8090 8370 1410 1645 1880 2115 2350 2585 2820 3055 3290 3525 3760 3995 4230 4465 4700 4935 5170 5405 5640 5875 6110 6345 6580 6815 7050 1530 1785 2040 2295 2550 2805 3060 3315 3570 3825 4080 4335 4590 4845 5100 5355 5610 5865 6120 6375 6630 6885 7140 7395 7650 1670 1945 2225 2500 2780 3060 3335 3615 3890 4170 4450 4725 5005 5280 5560 5840 6115 6395 6670 6950 7230 7505 7785 8060 8340 1780 2080 2375 2675 2970 3265 3565 3860 4160 4455 4750 5050 5345 5645 5940 6235 6535 6830 7130 7425 7720 8020 8315 8615 8910 1490 1735 1985 2230 2480 2730 2975 3225 3470 3720 3970 4215 4465 4710 4960 5210 5455 5705 5950 6200 6450 6695 6945 7190 7440 1630 1905 2175 2450 2720 2990 3265 3535 3810 4080 4350 4625 4895 5170 5440 5710 5985 6255 6530 6800 7070 7345 7615 7890 8160 1740 2030 2320 2610 2900 3190 3480 3770 4060 4350 4640 4930 5220 5510 5800 6090 6380 6670 6960 7250 7540 7830 8120 8410 8700 1825 2130 2430 2735 3040 3345 3650 3950 4255 4560 4865 5180 5470 5775 6080 6385 6690 6990 7295 7600 7905 8210 8510 8815 9120 * Increase by 5% for 60 F. room temperature. See separate Folder for Outputs at intermediate heights. CRANE -4 J r CRANE CONCEALED RADIATOR Outputs in B.Th.U.s per hour with Low Pressure Steam at 215 F. Room temperature 65 F. Number of Sections 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Overall Length Inches 13* 15* 17* 19* 21* 23* 25* 27* 29* 31* 33* 35* 37* 39* 41* 43* 45* 47* 49* 51* 53* 55* 57* 59* 61* Heating Surface Actual 7* 8* 10 II* 12* 13* 15 16* 17* 18* 20 21* 22* 23* 25 26* 27* 28* 30 31* 32* 33* 35 36* 37* 4*" width enclosure 6" width enclosure 8 " width enclosure 9 " width enclosure Height in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" Height in inches 18" 24" 30" 36" 1740 2030 2320 2610 2900 3190 3480 3770 4060 4350 4640 4930 5220 5510 5800 6090 6380 6670 6960 7250 7540 7830 8120 8410 8700 1900 2220 2535 2855 3170 3485 3805 4120 4440 4755 5070 5390 5705 6025 6345 6655 6975 7290 7610 7925 8240 8560 8875 9195 9510 2050 2395 2735 3080 3420 3760 4105 4445 4790 5130 5470 5815 6155 6500 6840 7180 7525 7865 8210 8550 8890 9235 9575 9920 10260 2200 2570 2935 3305 3670 4035 4405 4770 5140 5505 5870 6240 6605 6975 7340 7705 8075 8440 8810 9175 9540 9910 10275 10545 11010 2160 2520 2880 3240 3600 3960 4320 4680 5040 5400 5760 6120 6480 6840 7200 7560 7920 8280 8640 9000 9360 9720 10080 10440 10800 2335 2725 3110 3500 3890 4280 4670 5055 5445 5835 6225 6615 7000 7390 7780 8170 8560 8945 9335 9725 10115 10505 10890 11280 11670 2515 2935 3350 3770 4190 4610 5230 5445 5865 6285 6705 7125 7540 7960 8380 8800 9220 9635 10055 10475 10895 11315 11730 12150 12570 2650 3095 3535 3980 4420 4860 5305 5745 6190 6630 7070 7515 7955 8400 8840 9280 9725 10165 10610 11050 11490 11935 12375 12820 13260 2240 2610 2985 3355 3730 4105 4475 4850 5220 5595 5970 6340 6715 7085 7460 7835 8205 8580 8950 9325 9700 10070 10445 10815 11190 2430 2835 3240 3645 4050 4455 4860 5265 5670 6075 6480 6885 7290 7695 8100 8505 8910 9315 9720 10125 10530 10935 11340 11745 12150 2645 3085 3530 3970 4410 .4850 5290 5735 6175 6615 7055 7495 7940 8380 8820 9260 9700 10145 10585 11025 11465 11905 12350 12790 13230 2825 3295 3770 4240 4710 5180 5650 6125 6595 7065 7535 8005 8480 8950 9420 9890 10360 10835 11305 11775 12245 12715 13190 13660 (4130 2360 2750 3145 3535 3930 4325 4715 5110 5510 5895 6290 6680 7075 7465 7860 8255 8645 9040 9430 9825 10220 10610 11005 11395 11790 2590 3025 3455 3890 4320 4750 5185 5615 6050 6480 6910 7345 7775 8210 8640 9070 9505 9935 10370 10800 11230 11665 12095 12530 12960 2760 3220 3680 4140 4600 5060 5520 5980 6440 6900 7360 7820 8280 8740 9200 9660 10120 10580 11040 11500 11960 12420 12880 13340 13800 2890 3375 3855 4340 4820 5300 5785 6265 6750 7230 7710 6195 8675 9160 9640 10120 10605 11085 11570 12050 12530 13015 13495 13980 14460 See separate Folder for Outputs at intermediate heights. , --------------------------------------------------------------------------------------------------- ------- CRANE CRANE THE COPPER RADIATOR For combined heating and domestic installations in soft water districts where the use of Cast Iron Radiators might discolour the water, the Copper Radiator is offered. Soundly constructed of Copper Tubes with gun metal headers, the Crane Copper Radiator is of attractive appearance. THE COPPER RADIATOR, Sf in. wide Number Length of 2 in. Sections per section 36-/n. Height 3 sq. ft. per section Heating Surface PRICE s. d. 48 5 10 6 12 7 14 8 16 9 18 10 20 II 22 12 24 13 26 14 28 15 30 16 32 17 34 18 36 19 38 20 40 21 42 22 a 23 46 24 48 25 50 12 5 i? 0 15 7 8 9 18 8 18 6 21 10 8 3 24 II 18 0 27 13 7 9 30 14 17 6 33 16 17 3 36 17 17 0 39 19 6 9 42 20 16 6 45 22 6 3 48 23 16 0 51 25 5 9 54 26 15 6 57 28 5 3 60 29 15 0 63 31 4 9 66 32 H 6 69 34 4 3 72 35 14 0 75 37 3 9 30-jn. Height 2* sq. ft. per section Heating Surface PRICE s. d. 10 S 13 4 12} 7 1 8 15 8 10 0 I7i 9 18 4 20 II 6 8 22* 12 15 0 25 14 3 4 27} 15 II 8 30 17 0 0 32* 18 8 4 35 19 16 8 37} 21 5 0 40 22 13 4 42} 24 | 8 45 25 10 0 47} 26 18 4 50 28 6 8 52} 29 15 0 55 31 3 4 57} 32 N 8 60 34 0 0 62} 35 8 4 24-in. Height 2 sq. ft. per section Heating Surface PRICE s. d. 8 5 34 10 6 9 2 12 7 15 0 14 9 0 10 16 10 6 8 18 ii 12 6 20 12 18 4 22 14 4 2 24 15 10 0 26 16 15 10 28 18 I 8 30 19 7 6 32 20 13 4 34 21 19 2 36 23 5 0 38 24 10 10 40 25 16 8 42 27 2 6 44 28 8 4 46 29 14 2 48 31 0 0 50 32 5 10 Prices of Radiators include Polished and Lacquered finish as illustrated. Extra for Nickel Plating ... ,, ,, Chromium Plating .. 2/3 per sq.ft. 3/-............. * Add I in. to length for bushings. Legless Radiators 2f in less in height than whenwith feet. Radiators are tapped in. for air cock for water. Maximum size of connections, I in, 31 CRANE 7 RADIATOR SUNDRIES PEDESTALS Fig. 830 111 ill PRICES per Set of Four. 1 in. ........................... 2 in....................................... 3 in. ........................... 4 in. ........................... s. d. 20 22 2n 2 ii HIGH LEGS "Pall Mall" (excepting 2-column) and Hospital Radiators (excepting 3 in. wide), can be supplied with 6 in. legs (floor to centre of bottom tappings) if required. Price, per Radiator, 4/6 (if with centre leg section, 6/9). BLIND BOTTOM NIPPLE ' Radiators can be furnished with blind nipple at bottom between supply and second section or second and third sections. Please state on order. Price, per Radiator for 1" or l" nipples ............... ... ... 6d. CRANE RADIATOR FITTINGS Plugs, Cast Iron ............... Bushings ............................ Nipples, Mall. Iron ............... Manilla Paper Washers ... Bellite Washers ............... ... ... RADIATOR TOOLS 1" Price, each 3d. > 5d. M > 4^d. Price, per doz. 6d. > 1/6 ir 4d. 6d. 5d. 6d. 1/6 Fig. 834 Length in inches ............... ... 12 19 24 36 Fig. 831 Nipple Wrench for l nipples 1/9 -- 2/6 3/3 each Fig. 832 ,, ,, ,, I ,, -- 3/3 -- 3/3 ,, Fig. 833 Key Wrench, 10/3 each. Fig. 834 Plug and Bushing Wrench--1|" For Pall Mall, 5f" and 7" Hospital 8/- ,, . 1" For Wall, Concealed, and 3" Hospital 7/6 ,, 32 CRANE RADIATOR DETAILS STANDARD TAPPINGS (See separate list for Concealed Radiator details). Unless otherwise ordered all Radiators are supplied tapped as under: Heating Surface Hot Water Steam 1 to 12 sq. feet .. .. 13 to 30 sq. feet .. .. 31 to 50 sq. feet .. .. 51 and over .......................... VZ" \" \Y* 23f xyx 1Ji" x i" 1" x f" * Except for Wall 3* Hospital and copper Radiators, the maximum tapping for which is 1 In the absence of instructions radiators will be assumed to be for Hot Water. Radiators are despatched bushed top and bottom opposite ends in the absence of other instructions, but if required otherwise the connections should be described as under: . ORDERING END SECTIONS When ordering end sections, please state whether with or without feet, if for water or steam and whether flow end or return end. Inner screwing of flow sections is right hand and return sections left hand, excepting for Wall Radiators which are the reverse. Con cealed Radiators may be either. TESTING All radiators are twice tested to 100 lb. hydraulic pressure before leaving the factory. It is not recommended, however, that Radiators for Steam heating be used with a steam pressure exceeding 20 lb. (30 lb. for Concealed Radiators.) PAINTING. Radiators are painted at the Foundry one coat of grey protective paint which serves as a priming coat and will usually save one coat of decorators' paint. DESPATCHING LONG RADIATORS Six-Column and 5fin.or7 in. Hospital Radiators longer than 20 sections, Four-Column, Two-Column, 3 in. Hospital, and Window Radiators longer than 25 sections, and Con cealed Radiators longer than 36 sections will ordinarily be despatched in two or more portions. All Radiators with feet, of 25 sections and longer, will be supplied with centre leg section. Wall Radiators longer than 4 sections are likewise sent in portions. Please state on order if nipple wrenches are required (see page 32). 33 C CRANE CRANE HEATING BOILERS RANGE. The Heating Boilers described in the ensuing pages are suitable for all classes of buildings and include additional to previous lists a new design Carlton Boiler and a No. 4 series "Whitehall" Boiler. RATINGS. The ratings in British Thermal Units per hour are based on the Boiler heating surface multiplied by the usual constant of 4,400 B.Th.U. per square foot of Boiler heating surface. Ratings in square feet of Cast Iron Radiation are based on 160 B.Th.U. per square foot of Radiator surface, and in accordance with general practice are gross values. A deduction for pipe losses, etc., should be made to obtain the nett. FUEL CAPACITIES. The fuel capacities shown represent the capacity of the firebox up to the level of the centre line of the firing door. TAPPING DETAILS. All screwed connections on Crane Heating Boilers are tapped British Standard Taper Pipe Thread. For details of the tappings, see pages 37 and 78. SMOKE PIPES. All smoke outlets for Crane Heating Boilers are full area and to receive Pipes made to British Standard Specification No. 41. Boiler smoke outlets are Sockets. BOILER FORWARDING. "Carlton" Boilers are despatched with the sections assembled but all "Whitehall" Boilers are forwarded with sections unassembled. Crates for Whitehall Jackets only are returnable if delivered to our Works carriage paid within 7 days. ERECTING INSTRUCTIONS. Erecting instructions are sent with every Boiler but spare copies can be had on request. ENLARGING "WHITEHALL" SECTIONAL BOILERS. Any "White hall" Boiler may be extended up to the limit of the catalogue capacity by the addition of new sections which may be fitted either at the front or the rear. In the absence of other instructions, sections and nipples only are despatched; customers should state if they require new tie rods, damper rods and jacket extension pieces. 34 CARLTON BOILER CRANE HE "Carlton" Boiler is regarded as the most successful effort to Tprovide a Boiler combining a satisfactory appearance with an effective output. When supplied in vitreous enamel finish the Boiler is per fectly in keeping in a breakfast room, entrance hall, or other similar living room, yet internally, the arrangement of the heating surfaces is the acme of efficiency. This efficient design and the undermentioned exclusive features likewise contribute in producing "the Boiler that has set a new standard":-- PATENT DESIGN HE "Carlton" Boiler embodies the Crane TPatent controlled water travel feature which directs a rapid water circulation over the fire box crown, thus achieving maximum heat transfer and prolonged life of the Boiler. (Patent No. 354545). WATER-COOLED GRATE BARS 'lHE water-cooled Tgrate bars not only increase efficiency and reduce the formation of clinker but eliminate the continual expense of re newing burnt-out fire bars. Reveals the waterway top, the flues through which the gases travel before reaching the chimney, the water-cooled fire-bars and the water-way beneath the ash-pit. LOOSE SOLID GRILL BARS OOSE solid grill bars can be supplied instead L, of water-cooled if it is desired to convert to special systems of firing later. Showing how "Con trolled Water Tra vel" is attained by baffles directing the water flow over the fire box crown. PRE-HEATED SECONDARY AIR AXIMUM combustion of the fuel and gases Mis obtained by the entrance of secondary air above the fire bed: this air supply is under control and pre-heated by the special design of door and baffle. - 35 CRANE----------------------------------------------------------------------------------------- ACCURATE MACHINING AND STRENGTH VEN metal thickness, strength and accurate machining, all are found in Ethe "Carlton" Boiler. The more than usually adequate metal thickness ensures a wide margin of safety for all possible conditions and guards against fire box corrosion. The surfaces of all sections are ground true to give smoke-tight joints. STOKING PERIODS ADEQUATE fuel capacities are provided to avoid the necessity for too frequent stoking, and so that the boiler can easily be kept alight throughout the night hours. LOW RETURN TAPPING HE exceptionally low level of the main return enables radiators to be Tfixed at the same level as the Boiler. OIL FIRING HE design of the "Carlton" Boiler is especially Tsuitable for oil firing, for which purpose the boiler can be supplied without the watercooled grate bars. ROOM MODEL AND BASEMENT MODEL HE "Carlton" Boiler is supplied in two styles, Tthe Room Model and the Basement Model, the latter for the Heating Chamber, Basement or Scullery, without the moulded top and floor ash tray which are supplied with the Room Model. Bosses for Mountings are provided on the Base ment Model, and in the other case it is assumed the mountings will be attached to the pipework in inconspicuous positions. JACKETS Room Model with Jacket. Green or brown vitreous enamelled. I ACKETS are machine made of the highest quality sheet steel and included I in the price is the moulded base illustrated. The Room Model has an J uninsulated sheet steel Jacket enamelled the same colour as the Boiler when enamel finish is ordered, but the Jacket used with the Basement Boiler is a really efficient heat conserver, being lined with asbestos on sides, top and back. 36 HOT WATER SUPPLY N conjunction with a Crane Indirect ICylinder, the "Carlton" Boiler is most suitable for providing domestic hot water in addition to the radiator heating. The Boiler is provided with two separate flow tappings and an additional tapping can be provided on either side of the boiler for the return from the Indirect Cylinder. CRANE FIVE DIFFERENT STYLES HERE are no less than five styles in Twhich the "Carlton" Boiler is regu larly supplied. I. Room Model, black finish. 2. Room Model, with platework vitreous enamelled plain green or plain brown and boiler body finished in heat resisting paint to match. 3. Room Model with jacket, all vitreous enamelled mottled grey, plain green, or plain brown as standard. ' Plan view showing the efficient arrangement of heating surfaces, and the adequate waterways. The corrugated surfaces of the front and back of the fire box give increased transmission and addi tional strength. 4. Basement Model, black finish. 5. Basement Model, with asbestos lined galvanized sheet steel jackets. (Sizes 108 and 109 are not supplied in Room Model finishes.) TAPPING DETAILS O. 10 "Carlton" Boilers, 107 and Nlonger are provided with additional returns on both sides of second sec tion without extra charge and the arrangement of flow and return tap pings illustrated in the diagram, viz., flows and returns at opposite ends, is recommended with boilers longer than six sections. If it is thought necessary to connect to the rear section one return requiring a low level of tapping, then another return should preferably be connected to the second section of the boiler. ' CRANE THE NEW CARLTON Registered Design No. 829725 BOILER RATING AND CAPACITIES No. B.Th.U.s per hour Heating Power C.i. Radiation sq. ft. (gross) External Surface* B.Th.U.s per hour Boiler Heating Surface sq. ft. Fuel capacity cu. ft. Grate area sq. ft. Water Content gallons 3 32,500 205 2,800 7-40 0-87 0-70 4-5 4 42,000 265 3,000 9-55 105 0-80 5-2 5 51,500 325 3,300 11-70 1-35 1-05 5-9 6 61,000 385 3,600 13.85 1-65 1-30 6-6 PRICES Room Model Basement Model No. Boiler s. d. Jacket s. d. Vitreous Enamel Finish extra+ (Grey Mottle) s. d. Boiler^ s. d. Insulated Galvanized Steel Jacket', s. d. Stoking Tools s. d. 3 756 1 16 200 736 296 90 4 8 14 6 1 50 230 8 12 6 2 13 0 90 5 10 3 6 1 86 260 10 1 6 2 16 6 99 6 II 12 6 1 12 0 290 II 10 6 300 99 * Without Jacket. t Exposed portions of boiler and jacket enamelled same colour. Prices are for Mottled Grey: plain Dark Green, Dark Brown 25% extra: Cream and Black 50% extra. | Extra for Ash Tray, if required, 2/-. || Lined with sheet asbestos. Both Room and Basement Models can be supplied unjacketed, enamelled plain Green or Brown, Boiler in heat-resisting enamel, Platework in vitreous enamel, at the above enamelling prices. 38 CRANE THE NEW CARLTON BOILER Boiler No. 3 4 5 6 A Overall Length 201" 22" 25" 28" DIMENSIONS B Length of Boiler Smoke Pipe Size 121" 14" 17" 20" 41" 4|" 5" 5" Tappings at Back Flow* Returnf Two 2" Two 2" Two 2" Two 2" One 2" One 2" One 2" One 2" * One additional FLOW tapping 2" Size is provided on top of rear section of Basement Model only. Front section (Basement Model only) is provided with j'.and f" tappings for Thermometer and Safety Valve. f Additional 15" RETURN tappings can be furnished at either side to special order, 1/6 each nett extra. Damper Regulator when supplied operates check draught on right-hand side of smoke hood. Boilers can be supplied with smoke outlet looking upwards or to the back. The former are supplied unless otherwise instructed. Smoke outlets are sockets. All boilers are delivered with sections assembled. Dimensions and Prices of Smoke Pipes and Fittings shown on pages 96 and 97. See pages 100-106 for MOUNTINGS. 39 CRANE-------------------------------------------------------------------------------- THE NEW CARLTON OPEN FIRE Registered Design No. 829726 BOILER No. 30F 40F 50F 60F B.Th.U.s per hour Heating Power C.l. Radiation sq. ft. (gross) External Surface B.Th.U.s* per hour 32,500 42,000 51,500 61,000 205 265 325 385 3,000 3,200 3,500 3,800 Grate Area sq. ft. 0-70 0-82 1-06 1-30 Fuel Capacity cu. ft. 0-87 1 -05 1 -35 1 -65 Water Content Gallons 4-5 5-2 5-9 6-6 No. 30F 40F 50F 60F Boiler s. d. 75 8 14 10 3 II 12 6 6 6 6 Room Model Jacket $. d. PRICES Vitreous Enamel Finish extrat (grey mottled) s. d. 11 15 18 1 12 6 0 6 0 200 230 260 290 Basement Model Boileri s. d. insulated Galvanized Steel Jacketjj s. d. 73 8 12 10 1 II 10 6 6 6 6 29 2 13 2 16 30 6 0 6 0 Stoking Tools s. d. 90 90 99 99 * Without Jacket. + Exposed portions of boiler and jacket enamelled same colour. Prices are for Mottled Grey: plain Dark Green and Dark Brown 25% extra. t Extra for Ash Tray, if required, 2/-. || Lined with sheet asbestos. Both Room and Basement Models can be supplied unjacketed, enamelled plain Green or Brown, Boiler in heat-resisting enamel, Platework in vitreous enamel, at the above enamelling prices. 40 T ------------------------------------------------------------------------------- CRA N E THE NEW CARLTON BOILER Boiler No. A Overall Length B Length of Boiler c Smoke Pipe Size Tappings Flow* Room Basement Return Both Models 30F 40F 50F 60F 21" 22" 25i" 28i" I2F 14" 17" 20" 5" 5" 53" 53" H" Two 2" One 2" 4j" Two 2" One 2" 5" Two 2" One 2" 5" Two 2" One 2" One 2" One 2" One 2" One 2" * Basement Boiler is regularly supplied in addition with the two 2" flows on face of back section plugged. Additional \j" RETURN Tappings con be furnished at either side to special order at 1/6 each nett extra. Front section (Basement Model only) is regularly provided with and tappings for Thermometer and Safety Valve respectively. Damper Regulator when supplied operates on check draught on right hand side of smoke hood. Boilers are supplied with Smoke Hood with outlet pointing upwards or to back. The former is supplied unless otherwise instructed. Smoke outlets are sockets. All Boilers are delivered with sections assembled unless otherwise instructed. Dimensions and Prices of Smoke Pipe and Fittings shown on pages 96 and 97. See pages 100-106 for MOUNTINGS. 41 CRANE THE CARLTON BOILER ROOM MODEL WITH ENAMELLED JACKET BASEMENT MODEL WITH ASBESTOS LINED JACKET RATING AND CAPACITIES No. B.Th.U.s per hour Heating Power C.h Radiation sq. ft. (gross) *External Surface B.Th.U.s per hour 03 32,000 200 04 41,000 250 05 50,000 310 06 59,000 370 07 68,000 425 2,800 3,000 3,300 3,600 3,900 Boiler Heating Surface sq. ft. 7-25 9-35 11-35 13-40 15-45 Fuel Capacity cub. ft. 0-73 0-84 1-11 1-36 1-62 Grate Area sq. ft. 0-63 0-75 0-97 1-21 1-44 Water Content gallons 5-85 6-25 7-10 7-95 8-75 PRICES Boiler S. d. Room Model jacket s. d. Vitreous Enamel Finish Extrai s. d. Basement Model Boilerl 5. d. Insulated Galvanized Steel Jacket1 s. d. Stoking Tools s. d. 03 776 1 09 1 17 10 75 0 292 90 04 8 13 6 1 40 210 8 II 3 2 12 6 90 05 9 19 6 1 73 242 9 17 6 2 15 10 99 06 II 5 6 1 10 6 274 II 3 9 2 19 2 99 07 12 II 6 1 13 9 2 10 6 12 10 0 326 99 * Without jacket. f Exposed portions of boiler and Jacket enamelled same colour. Prices are for Mottled Grey: plain Dark Green and Dark Blown 25% extra: Cream and Black 50% extra. + Extra for Ash Tray, if required, 2/- jj Lined with sheet asbestos. Both Room and Basement Models can be supplied unjacketed, enamelled plain Green or Brown, Boiler in heat-resisting enamel, Platework in vitreous enamel, at the above enamelling prices. 42 i CRANE THE CARLTON BOILER SERIES No. O Boiler No. 03 04 05 06 07 A Overall Length 20i" 22" 25" 28" 31" DIMENSIONS* B Length of Boiler Smoke Pipe Size 12F 134" 161" 191" 221" 5" 5" 5" 5" 5" Tappings at Back Flow* Returnf Two 2" Two 2" Two 2" Two 2" Two 2" One 2" One 2" One 2" One 2" One 2" * One additional FLOW tapping Ij" Size can be furnished on top (Basement Model only) to special order, I /6 nett extra. Front section (Basement Model only) can be provided with and f" tappings for Thermometer and Safety Valve to order. f Additional l-j" RETURN tappings can be furnished at either side to special order, 1/6 each nett extra. All boilers tapped f" at front for Damper Regulator and plugged when Regulator not required. Boilers can be supplied with smoke outlet looking upwards or to the back. The former is supplied unless otherwise instructed. Smoke outlets are sockets. All boilers are delivered with sections assembled. Dimensions and Prices of Smoke Pipes and Fittings shown on pages 96 and 97. See pages 100-106 for MOUNTINGS. 43 CRANE THE CARLTON BOILER RATINGS AND CAPACITIES No. B.Th.U.s per hour Heating Power C.l. Radiation sq. ft. (gross) External Surface* B.Th.U.s per hour Boiler Heating Surface sq. ft. Fuel Capacity cu. ft. Grate Area sq. ft. Water Content gallons 104 70,000 105 85,500 106 101,000 107 116,500 108 132,000 109 147,000 440 535* 630* 730 825 920 5,200 6,100 7,000 7,900 8,800 9,700 15-90 19-40 23-00 26-50 30-00 33-50 1-61 2-09 2-58 3-04 3-53 4-00 1 -01 1 -32 1-63 1-94 2-25 2-56 9-35 10-79 12-23 13-67 15.12 16-57 PRICES Room Model Basement Model No. Boiler Jacket Vitreous Enamel Finish Boiler+ Insulated Galvanized Stoking Tools extra+ Steel Jacket s. d. s. d. $. d. s. d. s. d. s. d. 104 13 5 4 105 15 16 0 106 18 6 8 107 108 20 _17 4 109 ` 1 16 22 28 2 14 9 9 6 6 -- -- 2 15 32 38 3 15 6 0 6 0 -- -- 13 0 15 9 17 19 20 8 23 18 25 7 0 6 0 6 0 6 32 36 3 10 3 15 3 19 43 0 4 8 0 4 8 99 99 14 3 14 3 14 3 14 3 * Without Jacket. t Exposed portions of boiler and jacket enamelled same colour. Prices are for Mottled Grey: plain Dark Green and Dark Brown 25% extra: Cream and Black 50% extra. $ Extra for Ash Tray, if required, 2/6. || Lined with sheet asbestos. Both Room and Basement Models can be supplied unjacketed, enamelled plain Green or Brown, Boiler in heat-resisting enamel, Platework in vitreous enamel, at the above enamelling prices. 44 CRANE THE CARLTON BOILER DIMENSIONS* * * Boiler No. AB Overall Length of Length Boiler c Smoke Tappings D Pipe Size Flow* Returnf 104 26|" I4|" 71" 3f' 6" Two 2" One 21" 105 291" I7f" 71" 3" 6" Two 2" One 21" 106 33-g" 201" 71" 6" Two 2" One 21" 107 371" 241" 9" 1" 7" Two 2" One 21" 108 40f" 271" 9" 1" 7" One 21" One 21" 109 44" 30f" 9" H18 " 7" One 21" One 21" * Basement Boiler (all sizes) is regularly supplied with 2-j" flow on top of rear section and the two 2" flows on face of back section plugged. Additional 2" FLOW Tappings can be furnished at either side to special order at 2/- each nett extra. f Additional 2" RETURN Tappings can be furnished at either side to special order 2/- each nett extra except where returns are provided free (see page 37). Front section (Basement Model only) is regularly provided with 1* and " tappings for Thermometer and Safety Valves respectively. All Boilers tapped J" at front for Damper Regulator and plugged when regulator not required. No. 107 and 109 can be supplied with 6" smoke hood if specified on order, but 7" is advised for these sizes. (No. 107 has 6" smoke pipe when supplied as Room Model.) Boilers are supplied with Smoke Hood providing outlet pointing upwards or to back. Smoke outlets are sockets. All Boilers are delivered with sections assembled unless otherwise instructed. Dimensions and Prices of Smoke Pipe and Fittings shown on pages 96 and 97. See pages 100-106 for MOUNTINGS. 45 CRANE-------------------------------------------------------------------------- THE CARLTON BOILER ' SERIES Np. 10--OPEN FIRE 1 ROOM MODEL WITH ENAMELLED JACKET No, B.Th.Us, per hour Heating Power C.i. Radiation sq. ft, (gross) *External Surface B.Th.U.s per hour 104 70,000 105 85,500 106 101,000 107 116,500 440 535 630 730 5,200 6,100 7,000 7,900 Grate Area sq, ft. 1 -01 1 -32 1 -63 1 -94 PRICES* Fuel capacity cu. ft. 1 61 2 09 2-58 3 04 * Without Jacket. t Exposed portions of boiler and Jacket enamelled same colour. Prices are for Mottled Grey: plain Dark Green or Dark Brown 25% extra. Cream and Black 50% extra. $ Extra for Ash Tray, if required, 2/6. ]| Lined with sheet asbestos. Both Room and Basement Models can be supplied unjacketed, enamelled plain Green or Brown, Boiler in heat-resting enamel, Platework in vitreous enamel, at the above enamelling prices. 46 CRANE THE CARLTON BOILER SERIES No. 10 Boiler No. A6 Overall Length of Length Boiler c 104 26*' 14*' 105 291" 17*' 106 33** 201" 107 37*' 24i" w 7717"" 9" DIMENSIONS D Smoke Pipe* Size 3*' 6" 31" 6" 31" 6" H" 7" Tappings F/owt Room Basement Two 2" Two 2" Two 2" Two 2" One 21" One 21" One 21" One 21" Return Both Models One 21" One 21" One 21" One 21" * No. 107 has 6" Smoke Pipe when supplied as Room Model. t Basement Boiler is regularly supplied in addition with the two 2" flows on face of back section plugged. Additional 2" FLOW and RETURN Tappings can be furnished at either side to special order. Price 2/- each nett extra, except where returns provided free (see page 37). Front section (Basement Model only) is regularly provided with 1" and f* tappings for Thermometer and Safety Valve respectively. Damper Regulator operates on check draught on right-hand side of smoke hood. Boilers are supplied with Smoke Hood providing outlet pointing upwards or to back. Smoke outlets are sockets. All Boilers are delivered with sections assembled unless otherwise instructed. Dimensions and Prices of Smoke Pipe and Fittings shown on pages 96 and 97. See pages 100-106 for MOUNTINGS. 47 CRANE THE CARLTON BOILER WITH OVEN (Patent allied for) FOR RURAL SCHOOLS, WORKS, CANTEENS, Etc. The Carlton Boiler, fitted with oven, is very effective for warming milk or keeping food hot, but is not intended for cooking. The oven is insulated on the top and sides and is provided with two cast iron shelves and guides. Supplied unjacketed only. RATINGS AND PRICES No. B.Th.U.s per hour Heating Power C.l. Radiation sq. ft. (gross) Boiler* Vitreous Enamel Stoking Finish extraf Tools s. d. s. d. s. d. 104 70,000 440 20 10 0 2 15 6 99 105 85,500 535 22 19 6 320 99 106 101,000 630 25 9 0 386 14 3 107 116,500 730 27 18 6 3 15 0 14 3 108 132,000 825 30 8 0 416 14 3 109 147,000 920 32 17 6 480 14 3 * Black finish. Bright parts chromium plated 3/- extra. f Supplied unjacketed, enamelled (plain, not mottled) Green or Brown, Boiler Body and Oven in heat-resisting enamel paint, Platework in vitreous enamel. 48 r ------------------------------------------------------------------------CRANE THE CARLTON BOILER WITH OVEN Boiler No. 104 105 106 107 108 109 A Overall Length 28" 31*' 34* 37*' 41" 44*" DIMENSIONS* B Length of Boiler Smoke Pipe Size I4|" ' 17*' 20*' 24* 27* 30* 6" 6" 6" 6" 6" 6" Tappings at back Flow Return Two 2" Two 2" Two 2" Two 2" Two 2" Two 2" One 2* One 2* One 2* One 2* One 2* One 2* * Dimensions C, D, E, F and G are 60", 41", 185", 16" and 2f" respectively. Additional 2" FLOW and RETURN Tappings can be furnished at either side to special order at 2/- each nett extra, excepting where returns are provided free (see page 37). All Boilers tapped f" at front for Damper Regulator and plugged when regulator not required. Thermometer and Safety Valve should be fitted on Flow-pipe. All Boilers are delivered with sections assembled unless otherwise instructed. Dimensions and Prices of Smoke Pipe and Fittings shown on pages 96 and 97. See pages 100-106 for MOUNTINGS. 49 D CRANE CRANE GAS-FIRED BOILERS FOR CENTRAL HEATING OR INDIRECT HOT WATER SUPPLY I i SPECIFICATION: Boilers are fitted with a complete set of Barber-Duoflam Gas Burners with Pilot Jet and Cock. The equipment includes: Sizes 03G to I07G--Grey Mottled Enamelled Jacket; Size I08G-- Galvanized Insulated Steel Jacket, with Grey Mottled Enamelled Platework; Boilers size 14G upwards have Asbestos Lined Jacket finished in two-tone Green. Solid fire-bars are included throughout for the purpose of supporting the burners and possible con version to coke firing. Mountings include: Thermostat and Thermostat Valve with nickel plated copper tube connections, Gas Governor, chromium plated Gas Cocks on branches to burners. CONVERSION TO SOLID FUEL Boilers are so supplied that they can be converted to solid fuel firing simply by removal of the burner and sheet metal baffles, and the substitution of the standard clinker door for the special lower platework illustrated. For sizes of pipe connections and flue outlets, refer to ordinary solid fuel boilers. CRANE GAS-FIRED BOILERS FOR CENTRAL HEATING OR INDIRECT HOT WATER SUPPLY No. 03G 04G 05G 06G 07G I04G 105G I06G I07G I08G I4G I5G I6G 17G 24G 25G 26G 27G 28G 35G 36G 37G 38G 39G 3I0G 47G 48G 49G 4I0G 41IG 4I2G 4I3G 4I4G 4I5G 4I6G Rating B.Th.U.s per hour Heating Power Gas Consump C.l, Radiation tion, cubic feet sq. ft. (gross) per hour* 32,000 41,000 50,000 59,000 68,000 . 63,000 77,000 91,000 105,000 119,000 93,000 117,000 141,000 165,000 163,000 205,000 247,000 289,000 331,000 322,000 389,000 456,000 523,000 590,000 657,000 629,000 721,500 814,000 906,500 999,000 1,091,500 1,184,000 1,276,500 1,369,000 1,461,500 200 255 310 370 425 395 480 570 655 745 580 730 880 1,030 1,020 1,280 1,540 1,800 2,060 2,000 2,430 2,850 3,280 3,690 4,100 3,930 4,500 5,100 5,670 6,240 6,850 7,400 8,000 8,550 9,100 80 103 125 148 170 158 193 228 263 298 233 293 353 413 408 513 618 723 828 805 973 1,141 1,309 1,477 1,645 1,572 1,804 2,035 2,266 2,497 2,729 2,960 3,191 3,422 3,654 Size of Gas Supply 11i1" 3/' 43" 1" 2." 3.7/ 2." 1" >r ir iirr i\vv V 2" 2" 2" 2" 2" 2" 2 2Y 3" 3" 3" 3" 3" Vice L s. d. 17 n 19 10 21 19 23 12 25 13 0 0 0 0 0 27 6 0 30 7 0 34 8 0 39 0 0 41 5 0 33 7 39 12 43 5 49 16 0 0 0 0 53 14 59 8 69 4 77 13 87 17 0 0 0 0 0 92 16 101 5 124 3 137 16 148 8 161 9 0 0 0 0 0 0 163 0 0 182 0 0 201 0 0 221 0 0 240 0 0 259 0 0 278 0 0 297 0 0 316 0 0 335 0 0 * Based on 500 B.Th.U.s per hour calorific value of gas. Automatic Air Supply Control Valve, for Boilers No. I4G--No. 4I6G, 3 10 0 extra. It is recommended that the gas supply be one size larger than the size above indicated. Room Thermostat 1 18 6, Clock Control, details on application. Prices for Conversion Sets for existing Crane Boilers on application. The calorific value, supply pressure and the specific gravity of the gas supply should be mentioned when ordering. 51 CRANE i| 1 I ! THE WHITEHALL SECTIONAL BOILER (,Patent No. 354545) . HE "Whitehall" jacketed Sectional Boiler depicted above, for hot water, burns coke, anthracite or oil, and is manufactured in sizes to fit buildings of all types: "Whitehall" Boilers are abreast of the latest developments. These Boilers, made in our Ipswich Works, offer to the heating trade easier, more economical assembly, a better installation and an opportunity to stimulate sales by giving customers entirely new, outstandingly better products at no higher price. To the public is offered better heating efficiency and consequent fuel saving; the durability of fine engineering and a compact, neat beauty helping to abolish the ugly "stoke-hole" of the past. 52 CRANE WHITEHALL BOILERS EXCLUSIVE POINTS OF IMPROVEMENT HE efficient transfer of heat from fuel to the heating medium is Tthe primary consideration in designing a boiler. Crane designers have accomplished this by the following three EXCLUSIVE features:-- (tr) Controlled WATER TRAVEL. (>) Increased "CEILING" Heating Surface. (c) Restricted area high velocity gas flues. By these and other means every effort has been made to extract the maximum heat units from the fuel consumed so as to give lowest possible flue outlet temperatures. CONTROLLED WATER TRAVEL HIS outstanding feature is the direction of the water in the Tboiler over definite paths to absorb the maximum amount of heat. . Water rising up each leg is turned across the top of the combustion chamber by baffles. Here it rises through a passage formed by the inner sides of the first pass flues where the stream is divided and flows outwardly to each side of the boiler. It then rises to the top of the section and through the nipple ports to the flow outlets. Areas of water passages are proportioned to suit water flow. Consequently the major proportion of the water circulating through the boiler is directed over that most vulnerable part of the Boiler, the furnace crown, resulting in the highest rate of trans mission and tending to reduce "steaming" and the possible formation of scale. Secondly, the water passing over these most efficient heating surfaces travels a greater distance and at a higher rate of flow, with a scrubbing action that breaks TMs.diaBraml visualizes the Controlled 49 Water Travel as shown m the Nos. 2,3, down insulating film. and 4 "Whitehall" Sectional Boilers. 53 crane----------------------------------------------------------------------------------------- INCREASED "CEILING" HEATING SURFACE N the Nos. 2, 3 and 4 Boilers the elongated gas flues of both the O first and second pass present a maximum of "ceiling" heating surface, those horizontal surfaces at the top of the flues which being above the flue gases absorb greater heat than the side walls. There is approximately 50 per cent, more "ceiling" heating surface in Whitehall Boilers than in other similar boilers. Diagram illustrating the large proportion of "ceiling" heat ing surface. SCIENTIFICALLY DESIGNED GAS FLUES LUES of restricted area not only result Fin higher velocity gas flow giving increased transmission, but the whole area of each is traversed by the hot gases, instead of just the centre as with large sluggish flues. PREHEATED SECONDARY AIR NOTHER noteworthy feature is the provision made A to ignite the gases given off above the firebed by means of a preheated supply of secondary air applicable either to firing with a thin fire or when the boiler is banked. The air supply which is under control by means of hit and miss regulators passes twice over the baffle deflectors, thus absorbing the maximum heat and preventing the outer baffle from being burned through and becoming preheated at the same time. WATER COOLED GRATES ATER cooled grate bars, provided on all sizes of "Whitehall" Boilers, W assist in obtaining maximum efficiency and reduce the forma tion of clinker. They also save the building owner the expense and annoyance of continually renewing burnt out firebars. Boilers can be supplied fitted with loose grill bars, if a future change over to oil or an automatic stoker is contemplated. ATTENDANT'S WORK IS MADE EASIER ENDING has been made easier in a number of ways. The broad Tflat surfaces of gas flues have less tendency to collect efficiency impairing soot, and they afford ready access for cleaning. The smoke damper with positive indicator on front of boiler has a locking spring which holds it in position when adjusted. 54 ------------------------------------------------------------------------------------- CRANE MANUFACTURING PRECISION MEANS A NEATER, BETTER JOB, AND LOW COST INSTALLATION TILL more EXCLUSIVE features which demonstrate the superiority of CRANE "WHITEHALL" BOILERS:-- New Patented method of Assembly reduces labour and installation costs by one-third. (Patent No. 415007.) Flat surfaces of all sections are accurately ground by specially designed machines to give a tight, true fit. Putty groove gives added safeguard against air or gas leakage. All doors and dampers have accurately ground flat surfaces which permit them to shut tight, without air or dust leaks. Corresponding parts are interchangeable. Fittings secured to Boiler by means of loose bolts easily removed, instead of studs likely to break off. All Boilers assembled at Factory and tested hydraulically before despatch. Two-tone green jacket ^which effectively insulates and gives the Crane Boiler the appeal of beauty. HITEHALL Boilers are provided with Jackets which are a Wmarked advance on those obtainable elsewhere. Consulting and Heating Engineers have in the past preferred plastic asbestos, desiring an efficiently insulated boiler, although acknowledging the superior appearance and convenience of the sheet metal casing. Crane jackets conserve heat as much as does l^in. thickness of plastic asbestos, for the top, sides and back of the boiler are first protected with a I in. thick slab of high efficiency asbestos, guaranteed not to char or powder, and encasing this a machine-made steel jacket, tastefully finished in colour, giving permanence and a worth-while finish. HE jacket has been planned for exactness in fit and ease of installation. TAfter the boiler is installed and tested, the panels are simply set in place and four screws at the top corners inserted and tightened. The jacket need never be marred in making adjustments. To meet the requirements of those who wish for a metal casing only, without insulation, a competitive jacket of galvanized sheet steel is also offered but the insulated jacket is recommended. Jackets can be supplied for the Nos. 2, 3 and 4 " Whitehall " Boilers fixed in battery form. 55 THE No. I WHITEHALL BOILER FOR SOLID FUEL (with water cooled Firebars) RATINGS No. Boiler Heating Surface sq. ft. Heating Power C.l. Radiation sq. ft. (gross) B.T/i.U.s per hour Fuel Capacity cu. ft. 14 23-5 15 29-5 16 35-5 17 41 -5 18 47'5 650 815 975 1,140 1,300 104,000 130,000 156,000 182,000 208,000 2-6 3-5 4-4 5-3 6-2 Grate Area sq. ft. 2-32 3-10 3-90 4-68 5-47 Woter Content galls. 15-8 19-2 111 26-1 29-6 Number No. Sections B.Th.U.s per hour 14 4 15 5 16 6 17 7 18 8 104,000 130,000 156,000 182,000 208,000 PRICES Boiler s. d. 19 2 22 II 26 1 29 10 33 0 0 6 0 6 0 Stok/ng Too/s s. d. 19 0 19 0 113 1 13 1 40 Insulated Jacket in Colour s. d. 3 II 41 4 II 51 5 II 0 0 0 0 0 Non-insulated Galvanized Jacket s. d. 2 13 31 39 3 17 44 9 6 3 0 9 Stoking Tools and one " size emptying cock sent with boiler unless otherwise instructed. Extra Intermediate Sections with Nipples for extending Boiler ... each 3 9 6 Prices for new tie rods and damper rods on application. Jacket extension pieces, non insulated ...................................... per section ,, ,, ,, insulated.................................................. ,, 90 13 3 The No. I "Whitehall" Boiler can be supplied with or without loose grill bars instead of water cooled grates for Automatic Stoker Firing. Ratings and Prices on pages 66 and 74. CRANE THE No. I WHITEHALL BOILER FOR SOLID FUEL (Patent No. 354545) DIMENSIONS Number Length of Smoke No. of Boiler Pipe Sections A Size Screwed Tappings* Flows on 7of>t Returns at Side 14 4 22" 8" One 3" One 3" 15 5 28" 8" One 3" One 3" 16 6 34" 8" Two 3" Two 3" 17 7 40" 8" Two 3" Two 3" 18 8 46" 8" Two 3" Two 3" See page 80 for dimensions of ashpit * Indicates the number of tappings included in price. See page 78 for standard positions of tappings. f 2" tapping can be provided on top of rear section for open vent or flow Price 2/- net In addition all boilers have one 2" and two I" tappings for mountings and two l" for emptying. Special intermediate sections can be supplied with 3" screwed horizontal flow, height from floor to centre 35J". Customers should send sketch with order indicating desired position of tappings. Measurements and Prices of Boiler Fittings shown on pages 98 and 99. 57 THE No. 2 WHITEHALL BOILER FOR SOLID FUEL (with water cooled Firebars) RATINGS No. Boiler Heating Surface sq. ft. Heating Power C.l. Radiation sq. ft. (gross) B.Th.U.s per hour 24 40-0 25 50-7 26 61-4 27 72-1 28 82-8 29 93-5 1,100 1,390 1,690 1,980 2,280 2,570 176,000 223,000 270,000 317,000 364,000 411,000 Fuel Capacity cu. ft. 4-20 5-55 6-90 8-25 9'60 10-95 Grate Area sq. ft. 3-40 4-48 5-56 6-64 7-72 8-80 Water Content galls. 28-8 35-1 41-4 47-7 54-0 60-3 PRICES No. Number of Sections B.Th.U.s per hour Boiler s. d. Stoking Tools s. d. Insulated Jacket in Colour s. d. Non-lnsuloted Galvanized Jacket s. d. 24 4 176,000 30 13 0 19 0 5 2 0 3 14 6 25 5 223,000 36 9 6 19 0 5 14 0 4 4 0 26 6 270,000 42 6 0 1 1 3 6 6 0 4 13 6 27 7 317,000 48 2 6 1 1 3 6 18 0 5 3 0 28 8 364,000 53 19 0 1 4 0 7 10 0 5 12 6 29 9 411,000 59 15 6 140 820 620 Stoking Tools and one f" size emptying cock sent with boiler unless otherwise instructed- Extra Intermediate Sections with Nipples lor extending Boiler each 5 16 6 Prices for new tie rods and damper rods on application. Jacket extension pieces, non-insuiated ......................................per section II 0 ,, ,, ,, insulated ...................................... ,, 13 9 The No. 2 "Whitehall" Boiler can be supplied with or without loose grill bars instead of water cooled grates for Automatic Stoker Firing. Ratings and Prices on pages 68 and 74 THE No. 2 WHITEHALL BOILER FOR SOLID FUEL (Patent No. 354545) DIMENSIONS No. Number of Sections Length of Boiler A Smoke Pipe Size Screwed Flanges* Flows on Topt Returns at Side 24 4 25 5 26 6 27 7 28 8 29 9 23}" 29r 35jr" 4ir 47*" 53r 8" One it!' One 4" 8" Two 4" Two 4" 8" Two 4" Two 4" 8" Three 4" Three 4" 10" Three 4" Three 4" 10" Three 4" Three 4" See page 80 for dimensions of ashpit. * Indicates the number of tappings included in price. See page 78 for standard positions of tappings. f 2" tapping can be provided on top of rear section for open vent or flow. Price 2/- nett. In addition all boilers have one 2" and two I" tappings for mountings and two l" for emptying. On special order, two 4" flanged return connections can be provided on face of back r section; dimensions on diagram above. Special intermediate sections can be supplied with 4" flanged horizontal flow, height from floor to centre 445-". Customers should send sketch with order indicating desired position of tappings. A battery of two or more Boilers of the same length may be enclosed in a single jacket, centre to centre of Boilers 32". 59 r CRANE THE No. 3 WHITEHALL BOILER FOR SOLID FUEL (with water cooled Firebars) * No. Boiler Heating Surface sq. ft. Heating Power C.l, Radiation sq. ft. (gross) B.Th.U.s per hour Fuel Capacity cu. ft. Grate Area sq. ft. Water Content galls. 35 78-18 2,150 344,000 10-7 6-53 66-9 36 94-32 2,590 415,000 13-2 8-06 78-6 37 110-45 3,040 486,000 15-7 9-59 90-3 l 38 126-60 3,480 557,000 18-2 11-12 102-0 39 142-73 3,930 628,000 20-7 12-65 113-7 310 158-87 4,370 699,000 23-2 14-18 125-4 311 175-00 4,810 770,000 25-7 15-71 137-1 312 191-13 5,260 841,000 28-2 17-24 148-8 PRICES No. Number of Sections B.Th.U.s per hour Boiler s. d. Stoking Tools s. d. 35 5 344,000 54 6 0 1 26 36 6 415,000 62 7 0 1 2 6 37 7 486,000 70 8 0 1 6 0 38 8 557,000 78 9 0 1 6 0 39 9 628,000 86 10 0 1 II 6 310 10 699,000 94 II 0 1 II 6 311 II 770,000 102 12 0 1 13 6 312 12 841,000 110 13 0 1 13 6 Insulated Jacket in Colour d. 740 846 950 10 5 6 II 6 0 12 6 6 13 7 0 14 7 6 Non-lnsulated Galvanized Jacket s. d. 56 61 6 16 7 10 85 90 9 15 10 9 6 3 0 9 6 3 0 9 Stoking Tools and one size emptying cock sent with boiler unless otherwise instructed. Extra Intermediate Section with Nipples for extending Boiler ... each 8 I 0 Prices for new tie rods and damper rods on application. Jacket extension pieces, non-insulated .......................... ... per section 16 0 ,, ,, ,, insulated.................................................. ,, 10 0 The No. 3 "Whitehall" Boiler can be supplied with or without loose grill bars instead of water cooled grates for Automatic Stoker Firing. Ratings and Prices on pages 70 and 74. 60 L THE CRANE No. 3 WHITEHALL BOILER FOR. SOLID FUEL (Patent No. 354545) DIMENSIONS Number Length of Smoke No. of Boiler Pipe Sections A Size Screwed Flanges*t Flows on 7op Returns at Side 35 5 36 6 37 7 38 8 39 9 310 10 311 II 312 12 34" 10" Two A" Two 4" 41" 10" Two 4" Two 4" 48" 10" Two 4" Two 4" 55" 12" Three 4" Three 4" 62" 12" Three 4" Three 4" 69" 12" Three 4" Three 4" 76" 12" Three 4" Three 4" 83" 12" Three 4" Three 4" See page 80 for dimensions of ashpit. The No. 3 "Whitehall" has Universal Smoke Hood. * 5" Screwed Flanges for Flows and Returns can be supplied if required. f Indicates the number of tappings included in price. See page 78 for standard positions of tappings. 2" tapping can be provided on top of rear section for open vent or flow. Price 2/- nett. In addition all boilers have one 2" and two I" tappings for mountings and two |A" for emptying. On special order, two 4" flanged return connections can be provided on face of back section. Dimensions as diagram above. One or more special intermediate sections can be supplied with horizontal flow con nection with 4" or 5" screwed flange. Customers should send sketch with order indicating desired position of tappings. A battery of two or more Boilers of the same length may be enclosed in a single jacket, centre to centre of Boilers 42". 61 I ^ ----------------------------------------------------------- CRANE THE No. 4 WHITEHALL BOILER i RATINGS Boiler Heating Heating Power No. Surface C.l. Radiation sq. ft. sq. ft. {gross) B.Tfi.U.s per hour Fuel Capacity cu. ft. 47 148 4,060 650,000 20-19 48 170 4,680 748,000 23-43 49 192 5,290 846,000 26-67 410 215 5,900 944,000 29-91 411 237 6,510 1,042,000 33-15 412 259 7,130 1,140,000 36-39 413 282 7,740 1,238,000 39-63 414 304 8,350 1,336,000 42-87 415 326 8,960 1,434,000 46-11 Grote Area sq. ft. 11-92 13-86 15-80 17-74 19-68 21-62 23-56 25-50 27-44 Water Content galls. 136 154 172 190 208 226 244 262 280 PRICES No. Number of Sections B.Th.U.s per hour Boiler s. d. Stok/ng Tools $. d. insulated Jacket in Colour s. d. Non-insulated Galvanized Jacket. s. d. 47 7 650,000 93 5 0 1 80 II 5 0 830 48 8 748,000 106 17 0 1 80 12 7 0 8 17 9 49 9 846,000 120 9 0 1 12 6 13 9 0 9 12 6 410 10 944,000 134 | 0 1 12 6 14 II 0 10 7 3 411 II 1,042,000 147 13 0 1 14 0 15 13 0 112 0 412 12 1,140,000 161 5 0 1 14 0 16 15 0 II 16 9 413 13 1,238,000 174 17 0 1 14 0 17 17 0 12 II 6 414 14 1,336,000 188 9 0 1 14 0 18 19 0 13 6 3 415 15 1,434,000 202 1 0 1 14 0 20 1 0 14 1 0 Stoking Tools and two I" size emptying cocks sent with boiler unless otherwise instructed. Extra Intermediate Section with Nipples for extending Boiler ... each 13 12 0 Jacket extension pieces, non-insulated...................................... per section 18 0 ,,,, ,, insulated ...................................... ,, 14 0 The No. 4 "Whitehall" Boiler can be supplied with or without loose grill bars instead of water cooled grates for Automatic Stoker Firing. Ratings and Prices on pages 72 and 74. 62 CRANE THE No. 4 WHITEHALL BOILER FOR SOLID FUEL (Patent No. 354545) DIMENSIONS Number Length of Smoke No. of Boiler Pipe Sections A Size Screwed F anges* f Flows on Top Returns at Side 47 7 48 8 49 9 410 10 411 II 412 12 413 13 414 14 415 15 48" 55" 62" 69" 76" 83" 90" 97" 104" 14" Two 4" Two 4" 14" Two 4" Two 4" 14" Three 4" Three 4" 14" Three 4" Three 4" 14" Four 4" Four 4" 14" Four 4" Four 4" 16" Four 4" Four 4" 16" Four 4" Four 4" 16" Four 4" Four 4" See page 80 for dimensions of ashpit. The No. 4 "Whitehall" has.Universal Smoke Hood. * 5" Screwed Flanges for Flows and Returns can be supplied if required. t Indicates the number of tappings included in price. See pages 78 and 79 for standard positions. 2" tapping can be provided on top of rear section for open vent or flow. Price 2/- nett. In addition all boilers have one 2" and two 1^" tappings for mountings and two l" for emptying. On special order, two 4" flanged return connections can be provided on face of back section. Dimensions as diagram above. . One or more special intermediate sections can be supplied with horizontal flow con nection with 4" or 5" screwed flange. Customers should send sketch with order indicating desired position of tappings. A Battery oftwoormore Boilers of the same length may be enclosed in a single jacket. Centre to centre of Boilers, 52". 63 CRANE-------------------------------------------------------------------- THE WHITEHALL BOILERS FOR AUTOMATIC STOKER FIRING 1 HE outstanding features of the design of the "Whitehall" Sectional TBoiler render it peculiarly suitable for firing by a mechanical stoker. The illustration shows a well-known type burning a low-price Bituminous Coal in conjunction with a "Whitehall" Boiler. The advantage of the elongated two-pass gas flues, obtainable only in Crane boilers, is apparent. Ratings, capacities, and prices are as on pages 66 to 73; minimum length of Boiler, 5 sections. Enquiries should state the make of Stoker it is proposed to instal. "Whitehall" Boilers are suitable for firing by means of any of the well-known Automatic Stokers. 64 CRANE THE WHITEHALL BOILER FOR OIL BURNING HE Crane "Whitehall" Boilers are especially suited for Oil Burning. TIn the Nos. 2, 3, and 4 "Whitehall" Boilers the gases cannot pass direct from the burner to the chimney. The elongated two-pass flues ensure the longest possible travel for the gases and the machine-faced, smoke-tight joints of the sections effectively prohibit short circuiting. In fact all of the advantages already described on pages 52 to 54 likewise fully apply to the Oil Burning Boiler. In addition the ample and even thickness of the metal in the sections is of greatest value in resisting corrosion and ensures long life. The Boiler is ordinarily supplied without water-cooled grates. Provision is made for supporting ordinary firebars if it is desired to change to solid fuel. Prices of "Whitehall" Oil Burning Boilers are without firebars and include front plate to suit all well known Burners The top hung door is fitted with a sight hole of fireproof glass having protector inside. The Damper is fitted with locking device for setting in any desired position and no damper control rod is therefore supplied with the Boiler. A f" boss is provided on the smokehood for flue-stat or gauge. 65 E CRANE THE No. I WHITEHALL BOILER FOR OIL BURNING OR AUTOMATIC STOKER SERIES " L *' & H SERIES "L " (With Jacket) FOR OIL BURNING Front plate to suit Burner RATINGS SERIES "LS" (Without Jacket) FOR AUTOMATIC STOKER Front ashpit panel to suit Stoker No. 14 L 15 L & 15 LS 16 L & 16 LS 17 L & 17 LS 18 L & 18 LS 19 L & 19 LS $Boiler Heating Surface sq. ft. 21-0 26-5 32-0 37-5 43-0 48-5 Heating Power C.l. Radiation sq. ft. (gross) fCorobust/on Space cu. ft. 625 790 950 1,110 1,275 1,440 3* 6* n Si B.Th.U.s per hour 100,000 126,000 152,000 178,000 204,000 230,000 *Burner Capacity lbs. Oil per hour 7-0 9-0 10-8 12-7 14-5 16-4 f Above normal grate level. * Based on 14,000 B.Th.U.s net per lb. of fuel oil per hour. | Represents Heating surface without water cooled grates. Number No. ' of Sections 14 L 15 L & 15 LS 16 L & 16 LS 17 L & 17 LS 18 L & 18 LS 19 L & 19 LS 4 5 6 7 8 9 PRICES B.Th.U.s per hour 100,000 126,000 152,000 178,000 204,000 230,000 Boiler s. d. 18 6 21 II 24 15 28 0 31 4 34 9 9 3 9 3 9 3 Insulated Jacket in Colour s. d. 3 II 41 4 II 51 5 II 61 0 0 0 0 0 0 Non-insulated Galvanized Jacket s. d. 2 13 31 39 3 17 44 4 12 9 6 3 0 9 6 Extra Intermediate Sections, with nipples .......................... each 3 4 6 ii 66 4 CRANE THE No. I WHITEHALL BOILER FOR OIL BURNING OR AUTOMATIC STOKER (Patent No. 354545) DIMENSIONS No. Number of Sections Length of Boiler A Length of Com bustion Chamber Smoke Pipe D Size Screwed Flanges* Flows on Top Returns at Side 14 L 15 L & 15 LS 16 L & 16 LS 17 L & 17 LS 18 L & 18 LS 19 L & 19 LS 4 5 6 7 8 9 22" 28" 34" 40" 46" 52" 17V 23*" 29*" 35*" 41*" 47*" 8" One 3" One 3" 8" One 3" One 3" 8" Two 3" Two 3" 8" Two 3" Two 3" 8" Two 3" Two 3" 8" Three 3" Three 3" See page 80 for dimensions of ashpit. * Indicates the number of tappings included in price. See page 78 for standard positions of tappings. In addition all boilers have one 2" and two I" tappings for mountings and two I*" for emptying. Special intermediate section can be supplied with 3" screwed horizontal flow, height from floor to centre 35J". Customers should send sketch with order indicating desired position of tappings. Measurements and Prices of Boiler Fittings shown on pages 98 and 99. 67 A CRANE THE No. 2 WHITEHALL BOILER FOR OIL BURNING OR AUTOMATIC STOKER SERIES ** L" & "LS RATINGS SERIES " LS " (Without Jacket) FOR AUTOMATIC STOKER Front ashpit panei to suit Stoker No. $Boiler Heating Surface sq. ft. Heating Power C.l. Radiation sq.ft. (gross) f Combustion Space cu.ft. BJh,U.s per hour *Burner Capacity ibs. OH per hour 24 L 37-0 1,110 6 177,000 12-7 25 L & 25 LS 46-5 1,390 8 222,000 16-0 26 L & 26 LS 55-0 1,670 10 267,000 19-0 27 L & 27 LS 64-5 1,950 12 312,000 22-3 28 L & 28 LS 74-0 2,230 14 357,000 25-5 29 L & 29 LS 83-5 2,510 16 402,000 28-7 210 L & 210 LS 93-0 2,790 18 447,000 32-0 211 L & 211 LS 102-5 3,080 20 492,000 35-0 j- Above normal grate level. * Based on 14,000 B.Th.U.s net per lb. offuel oil per hour. | Represents Heating surface without water cooled grates. No. 24 L 25 L & 25 LS 26 L & 26 LS 27 L & 27 LS 28 L & 28 LS 29 L & 29 LS 210 L & 210 LS 211 L & 211 LS Number of Sections 4 5 6 7 8 9 10 II PRICES B.Th.U.s per hour Boiler s. d. 177,000 222,000 267,000 312,000 357,000 402,000 447,000 492,000 29 18 35 4 40 10 45 16 SI 2 56 8 61 14 67 0 0 0 0 0 0 0 0 0 Insulated Jacket in Colour s. d. 52 5 14 66 6 18 7 10 82 8 14 96 0 0 0 0 0 0 0 0 Non-insulated Galvanized Jacket s. d. 3 14 6 440 4 13 6 530 5 12 6 620 6 116 7 10 Extra Intermediate Sections, with nipples ........................ each 5 6 0 68 CRANE THE No. 2 WHITEHALL BOILER FOR OIL BURNING OR AUTOMATIC STOKER (Patent No. 354545) No. Number of Sections Length of Boiler A Length of Combustion Chamber D Smoke Pipe Size Screwed Flanges* Flows on Top Returns at Side 24 L 25 L & 25 LS 26 L & 26 LS 27 L & 27 LS 28 L & 28 LS 29 L & 29 LS 210 L & 210 LS 211 L & 211 LS 4 5 6 7 8 9 10 II 23*" 29*" 35*" 41*" 47*" 53*" 59*" 65*" 18*" 24*" 30*" 36*" 42*" 48*" 54*" 60*" 8" One 4" One 4" 8" Two 4" Two 4" 8" Two 4" Two 4" 8" Three 4" Three 4" 10" Three 4" Three 4" 10" Three 4" Three 4" 10" Three 4" Three 4" 10" Three 4" Three 4" See page 80 for dimensions of ashpit. * Indicates the number of tappings included in price. See page 78 for standard positions of tappings. ' In addition all boilers have one 2" and two \" tappings for mountings and two I*" for emptying. Two 4" flanged return connections are provided on face of back section and coupling headers supplied free of charge (see page 81). Special Intermediate section can be supplied with 4" flanged horizontal flow, height from floor to centre 445-". Customers should send sketch with order indicating desired position of tappings. A battery of two or more boilers of the same length can be enclosed in a single jacket centre to centre of boilers 32f". 69 CRANE THE No. 3 WHITEHALL BOILER FOR OIL BURNING OR AUTOMATIC STOKER SERIES "L" & 'LS" SERIES "L" (With Jacket) FOR OIL BURNING Front plate to suit Burner No, 35 L & 35 LS 36 L & 36 LS 37 L & 37 LS 38 L & 38 LS 39 L & 39 LS 310 L & 310 LS 311 L & 311 LS 312 L & 312 LS 313 L & 313 LS 314 L & 413 LS $BoilerHeating Surface sq.ft. 73-2 88-4 1036 118-8 134-0 149-2 164-4 179-6 194-8 210-0 RATINGS SERIES " LS " (Without Jacket) FOR AUTOMATIC STOKER Front ashpit panel to suit Stoker Heating Power C.l. Radiation sq. ft. (gross) 2,160 2,610 3,060 3,510 3,960 4,410 4,860 5,310 5,760 6,210 tCombustf'on Space cu. ft. 12 14* 17* 20} 23 25* 28* 31 33* 36 B.Th.U.s per hour *Burner Capacity lbs. Oil per hour 346,000 24-7 418,000 29-3 490,000 35-0 562,000 40-0 634,000 45-3 706,000 ' 50-4 778,000 55-6 850,000 60-7 922,000 66-0 994,000 71-0 f Above normal grate level. * Based on 14,000 B.Th.U.s net per lb. of fuel oil per hour. $ Represents Heating surface without water cooled grates. No. 35 L & 35 LS 36 L & 36 LS 37 L & 37 LS 38 L & 38 LS 39 L & 39 LS 310 L & 310 LS 311 L & 311 LS 312 L & 312 LS 313 L & 313 LS 314 L & 314 LS Number of Sections 5 6 7 8 9 10 II 12 13 14 PRICES B.Th.U.s per hour 346,000 418,000 490,000 562,000 634,000 706,000 778,000 850,000 922,000 994,000 Boiler s. d. 53 0 0 60 19 6 68 19 0 76 18 6 84 18 0 92 17 6 100 17 0 108 16 6 116 16 0 124 15 6 Insulated Jacket in Colour s. d. 740 846 950 10 5 6 II 6 0 12 6 6 13 7 0 14 7 6 15 8 0 16 8 6 Extra Intermediate Sections, with nipples .......................... each Non-insulated Galvanized Jacket s. d. 566 613 6 16 0 7 10 9 856 903 9 15 0 10 9 9 II 4 6 II 19 3 7 19 6 70 CRANE THE No. 3 WHITEHALL BOILER FOR OIL BURNING OR AUTOMATIC STOKER (Patent No. 354545) DIMENSIONS No. Number of Sections Length of Boiler A Length of Combustion Chamber D Smoke Pipe Size Screwed Flanges* Flows on Top Returns at Side 35 L & 35 LS 5 34" 29*" 36 L & 36 LS 6 41" 36*" 37 L& 37 LS 7 48" 43*" 38 L & 38 LS 8 55" 50*" 39 L& 39 LS 9 62" 57*" 310 L & 310 LS 10 69" 64*" 311 L & 311 LS II 76" 71*" 312 L & 312 LS 12 83" 78*" 313 L & 313 LS 13 90" 85*" 314 L & 314 LS 14 97" 92*" 10" Two 4" Two 4" 10" Two 6" Two 4" 10" Two 4" Two 4" 12" Three 4" Three 4" 12" Three 4" Three 4" 12" Three 4" Three 4" 12" Three 4" Three 4" 12" Three 4" Three 4" 12" Three 4" Three 4" 12" Three 4" Three 4" See page 80 for dimensions of ashpit. The No. 3 Whitehall has Universal Smokehood. _ * Indicates the number of tappings, included in price. See page 78 for standard positions of tappings. In addition all boilers have one 2" and two I" tappings for mountings and two I*" for emptying. Two 4" flanged return connections are provided on face of back section and coupling headers provided free of charge. (See page 81). Customers should send sketch with order indicating desired position of tappings. A battery of two or more boilers of the same length can be enclosed in a single jacket centre to centre of boilers 42". 71 CRANE THE No. 4 WHITEHALL BOILER FOR OIL BURNING OR AUTOMATIC STOKER SERIES L" & "LS" SERIES "L" (With Jacket) FOR OIL BURNING Front plate to suit Burner RATINGS SERIES "LS" (Without Jacket) FOR AUTOMATIC STOKER Front ashpit panel to suit Stoker No. ^Boiler Heating Power Heating Surface C.l. Radiation sq. ft. sq. ft. (gross) tCombust/on Space cu. ft. B.Th.U.s per hour *Burner Capacity lbs. Oil per hour 47 L & 47 LS 48 L & 48 LS 49 L & 49 LS 410 L & 4)0 LS 411 L & 41! LS 412 L & 412 LS 413 L & 413 LS 414 L & 414 LS 415 L & 415 LS 416 L & 416 LS 417 L & 417 LS 136-1 156-6 177-1 197-6 218-1 238-6 258-7 279-2 299-7 320-2 340-7 4,030 4,640 5,240 5,850 6,450 7,060 7,670 8,270 8,880 9,490 10,090 22-5 26-2 29-9 33-6 37-3 41-0 44-7 48-4 52-1 55-8 59-5 645,000 742,000 839,000 936,000 1,033,000 1,130,000 1,227,000 1,324,000 1,421,000 1,518,000 1,615,000 45 52 59 66 73 80 87 94 101 108 115 t Above normal grate level. * Based on 14,000 B.Th.U.s net per lb. of fuel oil per hour. $ Represents Heating surface without water cooled grates. PRICES No. Number of Sections B.Th.U.s per hour Boiler Insulated jacket in Colour Non-insulated Galvanized ' Jacket s. d. s. d. s. d. 47 L & 47 LS 7 645,000 88 10 0 11 5 0 48 L & 48 LS 8 742,000 101 10 0 12 7 0 49 L & 49 LS 9 839,000 114 10 0 13 9 0 410 L & 410 LS 10 936,000 127 10 0 14 II 0 411 L & 411 LS II 1,033,000 140 10 0 15 13 0 412 L & 412 LS 12 1,130,000 153 10 0 16 15 0 413 L & 413 LS 13 1,227,000 166 10 0 17 17 0 414 L & 414 LS 14 1,324,000 179 10 0 18 19 0 415 L & 415 LS 15 1,421,000 192 10 0 20 1 0 416 L & 415 LS 16 1,518,000 205 10 0 2! 3 0 417 L & 417 LS 17 1,615,000 218 10 0 22 5 0 Extra Intermediate Sections, with nipples .......................... 83 8 17 9 12 10 7 n2 11 16 12 11 13 6 14 I 14 15 15 10 0 9 6 3 0 9 6 3 0 9 6 13 0 0 72 THE No. 4 WHITEHALL BOILER FOR OIL BURNING OR AUTOMATIC STOKER (Patent No. 354545) DIMENSIONS No. Number of Length of Boiler Length of Combustion Chamber Smoke Pipe Sections A Size 47 L& 47 LS 7 48" 42f" 48 L & 48 LS 8 55" 49r 49 L & 49 LS 9 62" 56r 410 L & 410 LS 10 69" 63|" 411 L&4II LS II 76" 70!" 412 L & 412 LS 12 83" 77!" 413 L& 4(3 LS 13 90" 84!" 414 L & 414 LS 14 97" 91!" 415 L& 415 LS 15 104" 98!" 416 L & 416 LS 16 III" 105!" 417 L & 417 LS 17 118" 112!" 14" 14" 14" 14" 14" 14" 16" 16" 16" 16" 16" Screwed i /onge$*t Flows on Top Returns at Side Two 4" Two 4" Three 4" Three 4" Four 4" Four 4" Four 4" Four 4" Four 4" Four 4" Four 4" Two 4" Two 4" Three 4" Three 4" Four 4" Four 4" Four 4" Four 4" Four 4" Four 4" Four 4" See page 80 for dimensions of ashpit The No. 4 Whitehall has Universal Smokehood. * 5" screwed flanges for Flows and Returns can be supplied if required, f Indicates the number of tappings included in price. See pages 78 and 79 for standard positions. In addition all boilers have one 2" and two l" tappings for mountings and two I!" for emptying. Two 4" flanged return connections are provided on face of back section and coupling headers provided free of charge. (See page 81.) Customers should send sketch with order indicating desired position of tappings. A Battery of two or more Boilers of the same length may be enclosed in one jacket, centre to centre of boilers 52!". 73 CRANE WHITEHALL BOILERS SERIES "LW" WITH LOOSE SOLID FIREBARS INSTEAD OF WATER COOLED GRATES FOR SUBSEQUENT CONVERSION TO OIL BURNING OR AUTOMATIC STOKER FIRING No. Boiler Heating surface sq. ft. B.Th.U.s per hour CJ. Radiation sq. ft. Boiler s. d. Stoking Tools s. d. Insulated Jacket in Colour s. d. Non-insulated Galvanized Jacket s. d. 14 LW. 15 LW. 16 LW. 17 LW. 18 LW. 19 LW. 21-0 26-5 32-0 37-5 43-0 48-5 93,000 117,000 141,000 165,000 189,000 213,000 24 LW. 25 LW. 26 LW. 27 LW. 28 LW. 29 LW. 210 LW. 37-0 46-5 55-0 64-5 74-0 83-5 93-0 163,000 205,000 247,000 289,000 331,000 373,000 415,000 35 LW. 36 LW. 37 LW. 38 LW. 39 LW. 310 LW. 311 LW. 312 LW. 313 LW. 73-2 88-4 103-6 118-8 134-0 149-2 164-4 179-6 194-0 322,000 389,000 456,000 523,000 590,000 657,000 724,000 791,000 858,000 47 LW. 48 LW. 49 LW. 410 LW. 411 LW. 412 LW. 413 LW. 414 LW. 415 LW. 416 LW. 140-0 161-0 182-0 203-0 224-0 245-0 266-0 287-0 308-0 329-0 616,000 708,000 801,000 893,000 986,000 1,078,000 1,171,000 1,263,000 1,356,000 1,448,000 580 730 880 1,030 1,180 1,330 1,020 1,280 1,540 1,810 2,070 2,330 2,590 2,010 2,430 2,850 3,270 3,690 4,110 4,530 4,950 5,360 3,850 4,430 5,010 5,580 6,160 6,740 7,320 7,890 8,470 9,050 17 12 20 15 23 18 27 1 30 4 33 5 0 0 0 0 0 0 28 17 34 2 39 7 44 12 49 17 55 2 60 7 0 0 0 0 0 0 0 50 13 58 8 66 3 73 18 81 13 89 8 97 3 104 18 112 13 0 0 0 0 0 0 0 0 0 87 18 100 14 113 10 126 6 139 2 151 18 164 14 177 10 190 6 203 2 0 0 0 0 0 0 0 0 0 0 19 19 11 11 14 14 0 0 3 3 0 0 3 II 41 4 II 51 5| 61 0 0 0 0 0 0 19 19 11 11 I4 14 14 0 0 3 3 0 0 0 52 5 14 66 6 18 7 10 82 8 14 0 0 0 0 0 0 0 12 12 16 16 1 II 1 II 1 13 1 13 1 13 6 6 0 0 6 6 6 6 6 740 846 950 10 5 6 II 6 0 12 6 6 13 7 0 14 7 6 15 8 0 18 I8 1 12 1 12 1 14 1 14 1 14 1 14 1 14 1 14 0 0 6 6 0 0 0 0 0 0 II 5 12 7 13 9 14 II 15 13 16 15 17 17 18 19 20 1 21 3 0 0 0 0 0 0 0 0 0 0 2 13 31 39 3 17 44 4 12 9 6 3 0 9 6 3 14 44 4 13 53 5 12 62 6 II 6 0 6 0 6 0 6 56 6| 6 16 7 10 85 90 9 15 10 9 II 4 6 3 0 9 6 3 0 9 6 83 8 17 9 12 10 7 II 2 | | 16 12 II 13 6 14 1 14 15 0 9 6 3 0 9 6 3 0 9 Series "LW" Whitehall Boilers have no waterway across front section opening and Nos. 2,3 and 4 Boilers are provided with a special connecting header at back. (See page 81.) The Boilers are easily converted for Oil Burning or Automatic Stoker Firing by the removal of front platework and firebars and fitting with the requisite front. The damper rod can be removed and damper locking feature substituted. 74 >r' .V WHITEHALL BOILERS FOR LOW PRESSURE STEAM With Mild Steel Steam Drum which ensures dry steam and effectively checks priming Boiler is fitted with a size Fusible Plug as required by the Factory Act. 75 CRANE WHITEHALL BOILERS With water cooled grates and for hand firing. For low pressure steam up to and including 15 lb. per sq. in. working pressure. Drum tested 30 lb. No, B.Th.U.s per hour Heating Power C.t, Radiation sq. ft. Overall Height Height to Water Level Price s. d. 15 130,000 16 156,000 17 182,000 18 208,000 25 223,000 26 270,000 27 317,000 28 364,000 29 411,000 35 344,000 36 415,000 37 486,000 38 557,000 39 628,000 310 699,000 311 770,000 312 841,000 47 650,000 48 748,000 49 846,000 410 944,000 411 1,042,000 412 1,140,000 413 1,238,000 414 1,336,000 415 1,434,000 416 1,532,000 510 610 710 810 870 1,055 1,240 1,420 1,605 1,340 1,620 1,900 2,180 2,450 2,730 3,010 3,290 2,600 3,000 3,400 3,780 4,170 4,550 4,950 5,350 5,750 6,100 .61" 61" 61" 61" 71" 71" 71" 71" 71" 841" 841" 841" 841" 841" 841" 841" 841" 97" 97" 97" 97" 97" 97" 97" 97" 97" 97" 50" 44 10 0 50" 50 0 0 50" 55 10 0 50" 61 0 0 56" 62 10 0 56" 71 0 0 56" 79 10 0 56" 88 0 0 56" 97 10 0 68" 87 0 0 68" 100 0 0 68" 113 0 0 68" 127 10 0 68" 139 15 0 68" 152 15 0 68" 167 17 0 68" 183 0 0 78" 146 0 0 78" 166 5 0 78" 183 15 0 78" 203 0 0 78" 225 10 0 78" 245 15 0 78" 268 5 0 78" 289 10 0 78" 311 0 0 78" 333 0 0 Price includes steam mountings, comprising water gauge, pressure gauge, safety valve, draw off cock, and automatic damper regulator. See page 107 for price of Automatic Boiler Feeder. Price of stoking tools and jackets as on page 74. 76 ------------------------------------------------------------------------------------ CRA N E WHITEHALL BOILERS FOR SPECIAL SYSTEMS In addition to the standard boilers illustrated on the foregoing pages, Whitehall Boilers are frequently supplied for other methods of firing. The exclusive advantages of the controlled water travel, and also the two-pass flues which prohibit short-circuiting the products of combustion to the chimney, cause the Whitehall Boiler to be much in demand, especially for various gaseous forms of combustion. The following are some examples of special systems which can be quoted for: GAS FIRED STEAM BOILERS The Whitehall Boilers for low pressure steam can readily be supplied gas fired. Quota tions will include the appropriate controls, either pressure operated or electrically operated as required. When sending specification, please state required working pressure, and if electrical controls are required, the voltage. OIL FIRED STEAM. BOILERS Many successful installations of this boiler have been effected and enquiries are invited. Again, working pressure and details of the electrical supply should be stated. WHITEHALL BOILERS FOR PULVERIZED FUEL The design of the flues of the Nos. 2, 3, and 4 Whitehall Boilers render the boiler particularly suitable for this form of firing. The illustration shows one of a large group of factory installa tions, but this method of firing is equally suitable for cinemas and blocks of flats. BOILER ASSEMBLIES LONGER THAN STANDARD Whitehall Boilers are frequently called for in longer assemblies than those listed in the foregoing pages. No difficulty arises in supplying boilers as long as 18 or 19 sections. Here again, the design of the boiler makes it appropriate for these conditions. Prices and Outputs on Application. ' I 77 t i T CRANE WHITEHALL BOILER TAPPING DETAILS HE number of Tappings included in the price of the "Whitehall" Boilers and standard Tpositions for Tappings are shown below. The positions may be varied to suit customers' requirements, although the standard positions as under are advised to avoid delays. Additional flow and return tappings can be provided on all but front and rear sections. Rl and R2 are alternative positions for the third return tapping. HE EfaE: EE rh IE 1R2 Bll ? _ ' IRt Ril I ~ ' IR? Rl I rv ^~p~ tsz is= It is recommended that as far as possible flows and returns should be ; o at the opposite ends of the Boiler, This applies to normal connections as well as when returns are con nected to the rear of the boiler as depicted on the next page. The front sections of all Boilers are tapped for mountings as follows:--see above drawings of Boilers:-- Emptying, 2--1" on face. Damper Regulator, 2" on top, in centre. Safety Valve, I" for Nos. I and 2 Boilers, Ifor No. 3 Boiler, and l" for No. 4 Boiler, on left. (Additional tapping of same size can be provided on right if desired. Price 1/6 nett) The second sections of Boilers ordered with Damper Regulator are tapped I" for thermometer. 78 CRANE WHITEHALL BOILER TAPPING DETAILS Standard connections are.--No. I Boiler, bosses tapped 3" (bushed down if required); Nos. 2, 3, and 4 Boilers, counter flanges tapped up to 4" B.S. Pipe Thread (No. 3 and 4 tapped 5" to order). To special order 4" returns can be provided in the face of rear section of Nos. 2, 3, and 4 Boilers. See pages 59, 61, and 63. Special intermediate sections can be supplied having horizontal flow outlet on side of Boiler. See pages 57, 59, 61, and 63. Extra tappings (where obtainable) on top, side or back of Boiler are charged as follows:-- On No. I Boiler, extra 3" flow or return tappings ... Price, each tapping, 3/-nett On Nos. 2, 3, and 4 Boilers, extra 4" (or 5" on No. 3 and 4) tapped flanges Price, each tapping, 5/- nett OPEN VENT PIPE A tapped boss can be provided on top of rear section for open vent pipe up to 2" size Price 2/6 nett REAR RETURNS When return tappings are used on the rear of the Boiler (obtainable on Nos. 2, 3, and 4 Boilers) the flow outlet should be as near the front of the boiler as possible, and at least as far forward as the third section. An/ additional flows should likewise be as near to the front of the boiler as possible. Not only is more efficient heat transfer secured but overheating of individual sections avoided. The diagram above indicates the application of the foregoing and also the standard tapping arrangement for boilers with rear returns. See page 81 for particulars of cast-iron headers. 79 4 CRANE THE WHITEHALL BOILERS BASE AND ASHPIT DIMENSIONS 1 N ashpit should be provided with all "Whitehall" Boilers for solid fuel and where Aheight is not limited a raised base as shown above is recommended for oil-burning boilers also, in order to protect the feet of the sections from damp and to allow ashpit door to open freely. The top of the base should be rendered perfectly level and smooth. Boilers for Auto matic Stoker firing should have 4*" or 6" high base. DIMENSIONS IN INCHES I No. of Sections A 6 cD 4 29 17 28 14 No. 1 5 35 23 28 14 6 41 29 28 14 BOILER 7 47 35 28 14 8 53 41 28 14 9 59 47 28 14 4 30 18 36 22 5 36 24 36 22 6 42 30 36 22 No. 2 7 48 36 36 22 BOILER 8 9 54 60 42 48 36 36 22 22 10 66 54 36 22 II 72 60 36 22 5 42 26 48 29* 6 49 33 48 29* 7 56 40 48 29* No. 3 8 63 47 48 29* 9 70 54 48 29* BOILER 10 77 61 48 29* II 84 68 48 29* 12 91 75 48 29* 13 98 82 48 29* 14 105 89 48 29* 7 57 41 58 36 8 64 48 58 36 9 71 55 58 36 10 78 62 58 36 No. 4 II 12 85 92 69 76 58 58 36 36 BOILER 13 99 83 58 36 14 106 90 58 36 15 113 97 58 36 16 120 104 58 36 17 127 III 58 36 80 .......................... .................................... ...........-- 1 -------------------------------------------------------------------------CRA N E WHITEHALL BOILER SUNDRIES BACK RETURN HEADERS Fig. 970/1/2. Plain. Fig. 974/5/6. With tapped boss as drawing FLOW AND RETURN HEADERS Fig. 978/9/80. With 5" outlet flange. Fig. 982/3/4. With 5" outlet flange and boss as drawing. When ordering state if required with flange looking up as drawn or to the rear as shown dotted. Fig. 987/8/9. Headers connecting flanged outlets of two alternate sections of Nos. 2, 3 and 4 Boilers. Outlet flanges are to British Standard Table "D" particulars. For Prices of Counter flanges--see page 139 DIMENSIONS AND PRICES* Fig- Size for No. Whitehall Boiler A fi C D E F Price 970 4" for No. 2 971 4" ,, ,, 3 972 4" ,, ,, 4 ... 24#' 52" Si" _ _ 31/- ... 33" 5r 53." -- -- -- 34/- ... 431" 5r 5J24." -- -- -- 36/- 974 4" ,, .. 2 975 4" ,, .. 3 976 4" 4 ... ... ... 24#" 33" 43*' 5Ci3T* JC43" C3" 5f" -- sr -- _ -- -- _ 33/- -- 36/-- 38/- 978 4" ,, ,, 2 979 4" ,, ,, 3 980 4" .. 4 ... 24*' C3" 53// _ _ _ 38/- ... 33" 5F 5r -- -- -- 41/... 431" sr sr -- -- -- 43/- 982 4" ,, ,, 2 983 4" ,, ,, 3 984 4" ,, ,, 4 ... ... 24#' 33" 5C?3"" sr _ 52* -- __ -- _ 40/- -- 43/- ... 431" 5J24." SJ4i" -- -- -- 4S/- 985 For No. 3 or No. 4 986 987 For No. 2.............. 988 ,, No. 3 or No. 4 989 tt __ __ __ 5" 2|" 6" 50/-- -- -- 5" 21" 5" 50/-- -- -- 4" 12" 5" 46/-- -- -- 5" 14" 5" 46/--- -- -- 5" 14" 6" 46/- *Fig. 970/1/2 supplied free of charge with series "L," "LS" and "LW" Whitehall Boilers Nos. 2, 3 and 4 Difference in price will be charged on these boilers when other Headers are supplied. 81 F CRANE BOILER SUNDRIES SPANNERS AND ASSEMBLY TOOLS FOR CRANE HEATING BOILERS NEW CARLTON AND No 0 CARLTON 1--2" Key Spanner l-H" ,, ,, i-r .. 1--2" Hex. Plug Ring Spanner 1--*" Standard Box Spanner 1--1 lb. Hammer 1--|" Assembly Tool Price per set ... . 2!/- No. 1 WHITEHALL 1--Whitworth Box Spanner 1--rf" & Double Ended Spanner 1--%" Fig. 840 Wrench 1--lj" Key Spanner for C'sunk Plug 1--2 lb. Hammer Price per set ... 18/6 No. 10 CARLTON 1--2" Key Spanner i-r ,, ,, i-r .. .. 1--2" Hex. Plug Ring Spanner 1--|" Box Spanner 1 -- 1 lb. Hammer 1--j" Assembly Tool Price per set ... 24/6 No. 2 WHITEHALL 1 -- tV' & " Double Ended Spanner I1 __42" tt tt tt 1--Box Spanner 1--Fig. 840 Wrench 1--?r Key Spanner for C'sunk Plug 1--2 lb. Hammer Price per set ... 20/- No. 3 WHITEHALL 1--J" Whitworth Box Spanner 1--& %" Double Ended Spanner 1--Fig. 840 Wrench 1--Open End Spanner 1--Ij" Key Spanner for C'sunk Plug 1--2 lb. Hammer Price per'set ... 20/- No. 4 WHITEHALL 1--!%" & Double Ended Spanner 1--j" Open End Spanner 11 __4a." ' > 1--Box Spanner 1--!" Fig. 840 Wrench 1--Spanner for l" C'sunk Plug 1--2 lb. Hammer Price per set ... 21/6 See page 189 for illustrations of the above-mentioned Key Spanners and Fig. 840 Wrench. MUDHOLE JOINT RINGS FOR DOMESTIC BOILERS Boiler No. PRICE per boiler per set Boiler No. PRICE per boiler per set Ipswich No. 00 & 01 ,, No. 1 ... ,, No. 2 ... ,, No. 3 ... Regent No. 4 ... ,, No. 5 ... Circular No. 4C ... ,, No. 5C ... 1 2 2 4 5 5 5 5 1/6 Circular No. 8C ... 7 2/- ,, No. 9C... 7 2/- Sectional No. 3 ... 16 3/6 ,, No. 4 ... 20 4/- ,, No. 5 ... 24 4/- ,, No. 6 ... 28 4/- ,, No. 7 ... 32 4/- ,, No. 8 ... 36 4/9 4/9 9/3 10/II/11/9 14/16/3 MICA PANELS FOR IPSWICH BOILERS Per set of 6 for Nos. 01, I, 2, and 3 Boilers ...................................... Price per set lOd. BOILER CEMENT For jointing Smoke Pipes and Furnace Fittings 2 lb. tin, Price I/- 5 lb. tin, Price 2/- 82 CRANE CRANE DOMESTIC BOILERS RANGE. The range of Domestic Boilers described in the following pages includes Boilers suitable for all buildings from the smallest villa or bungalow up to the largest buildings usually served by Cast Iron Domestic Boilers. RATINGS. All Crane Domestic Boilers are based for rating on the actual Boiler heating surface above grate level multiplied by the following constants:-- ' " Ipswich " Domestic Boilers, 10,000 B.Th.U.s per square foot of Boiler heating surface. "Regent" and Circular Domestic Boilers, 11,000 B.Th.U.s per square .foot of Boiler heating surface. Sectional Domestic Boilers, 8,000 B.Th.U.s per square foot for normal firing and 11,000 B.Th.U.s per square foot for heavy firing. The above transmissions of 10,000 and 11,000 B.Th.U.s per square foot are for short periods of high output as normally occur in residences. But for a continuous duty the British Standards Institution recommends a trans mission of 6,000 B.Th.U.s be employed. TAPPING DETAILS. All Crane Domestic Boilers are tapped British Standard Taper Pipe Thread. ENAMEL FINISHES. " Ipswich," " Regent " and the 4c and 5c Cir cular Domestic Boilers are supplied in vitreous enamel finishes, the standard colour being grey mottled. Other mottled and plain colours can be supplied on request. " Ipswich " Boilers can be supplied in cream and black vitreous enamel. BOILER FORWARDING. " Ipswich " Domestic Boilers for the home market are delivered assembled in readiness for fixing. " Regent " and Circular Domestic Boilers are delivered as fire pots with plate work packed in open crate. Sectional Domestic Boilers are delivered unassembled with plate work packed in open crate. WORKING INSTRUCTIONS. Working instruction-cards sent with every Boiler, but additional copies may be had on request. Erecting instructions can be supplied if called for. 83 CRANE THE IPSWICH DOMESTIC BOILER OPEN FIRE FOR HOT WATER SUPPLY No. 00 Registered Design No. 829723 No. 00 ENAMELLED FINISH Size No. Fuel Capacity 00 50 Heating Surface sq. ft. 2-00 RATINGS B.Th.U.s per hour for Hot Water Supply only 20,000 50-110s F. 33 Gallons per hour maximum 50-130 F. 50-150 F. 25 * 20 PRICES Size All Black No. Finish s. d. 00 3 3 0 Black finish with polished top* s. d. 350 Grey Mottled enamel finish tfirepot painted aluminium)f s. d. Extra for Enamelled Sideplates s. d. 3 16 6 54 Extra for Bower-Barffing Firepot s. d. 1 50 Extra for Shaking Grate s. d. 33 Price of Boiler includes base feet and ash pan. Stoking Tools 1/4 extra * Hotplate dull nickel plated 7/9 extra. t Hotplate can be supplied ground and polished instead of enamelled at same price. Extra for dull nickel plated hotplate with enamelled boiler 7/9. 84 CRANE THE IPSWICH DOMESTIC BOILER OPEN FIRE FOR HOT WATER SUPPLY DIMENSIONS Size No. Height to Hotplate Size of Hotplate Overall projection, back to front Height to centre of Tapping FLOW RETURN Tappings at Back* Smoke Pipe size 00 23f" 17" X 15" 17*" 20f" 12*' ' Two 1*" 4" ^Alternatively 4--I*" Tappings can be provided at sides to special order, price 3/- extra. The No. 00 Ipswich Boiler is suitable for hot water storage up to 25 gallons, and a Towel Airer may be added. To ensure fuel economy it is not recommended that this duty be increased. Stoking Tools and *" Draw-off Cock sent with Boiler unless otherwise ordered. See pages 96 and 97 for Measurements and Prices of Smoke Pipe and Fittings in Black and Enamel finish. For MOUNTINGS see pages 100-104. 85 r CRANE------------------------------------------------------------ ------------ THE IPSWICH DOMESTIC BOILER OPEN FIRE FOR HOT WATER SUPPLY No. 01 Registered Design No. 829724 No. 01 ENAMELLED FINISH WITH SIDE PLATES RATINGS Size No. Fuel Capacity cu. ft. Heating Surface sq. ft. B.Th.U.s per hour for Hot Water Supply only 50-110 F. Gallons per hour maximum 50-130 F. 50-150 F. 01 55 2-25 22,500 38 28 23 PRICES Size No. Black finish with polished top s. d. Black Finish with nickelplated top.* s. d. Grey Mottled enamel finish (firepot painted aluminium)t s. d. Extra for Enamel Sideplates s. d. Extra for Bower-Barffmg Firepot s. d. Extra for Shaking Grate s. d. 01 4 10 0 4 18 0 600 60 1 76 33 Price of Boiler includes base, feet and ash pan. Stoking Tools I /6 extra * Dull nickel plated. f Hotplate can be supplied ground and polished instead of enamelled at same price. Extra for dull nickel plated hotplate with enamelled boiler, 8/6. Boilers can be supplied in Cream Enamelled finish and with Black Enamel hotplate. Price 15/- extra. 86 CRANE THE IPSWICH DOMESTIC BOILER OPEN FIRE FOR HOT WATER SUPPLY DIMENSIONS Size No. Height to Hotplate Size of Hotplate Overall projection, back to front Height to centre of Tapping FLOW RETURN Tappings at side Smoke Pipe Size 01 24i" 18" x I6i" 181" 20F Q'4l" Four IF 4" The No. 01 Ipswich Boiler is suitable for a 25-gallon hot water storage with a Towel Airer, and will also comfortably heat a Radiator up to 17 sq. ft. To ensure fuel economy it is not recommended that the above duties be increased. Stoking Tools and Draw-off Cock are sent with Boilers unless otherwise instructed. See pages 96 and 97 for Measurements and Prices of Smoke Pipe and Fittings in Black and Enamel finish. For MOUNTINGS see pages 100-104. 87 r CRANE ------------------------------------------------------------------------------- THE IPSWICH DOMESTIC BOILER OPEN FIRE FOR HOT WATER SUPPLY Nos. I, 2 and 3 No. 1 BLACK FINISH, WITH POLISHED TOP Size No. Fuel Capacity cu. ft. Heating Surface sq. ft. i 65 2-80 2 95 4-00 3 I-35 5-00 RATINGS B.Th.U.s per hour for Hot Water Supply only* 28,000 40,000 50,000 No. I ENAMELLED FINISH, WITH S,DE PLATES Go//ons per hour maximum 50-110 F. 50-130 F. 50-150 F. 47 35 28 66 50 40 84 63 50 * If used for Heating only the ratings are 12,500, 18,000 and 22,000 B.Th.U.s per hour respectively. PRICES Size No. Black finish with polished top Black finish with nickel plated top Grey Mottled enamel finish (firepot painted aluminium)* Extra for Enamel Sideplates Extra for Bower-Barffed Rustless Firepot Extra for Shaking Gratef s, d. 5. d. s. d. s. d. s. d. s. d. i 5 16 3 67 3 7 14 9 70 1 14 9 43 2 8 12 6 9 3 3 10 7 6 86 21 3 54 3 I MO 0 12 5 0 14 0 0 14 0 2 15 0 -- * Hotplate can be supplied nickel plated instead of enamelled at same price. f Shaking Grate fitted on all No. 3 Boilers. Prices of Boilers Nos. I and 2 include base and feet. No 3 Boiler has base but no feet. Stoking Tools, Nos. I and 2, 2/6, No. 3, 4/- per set. Boilers can be supplied in Cream Enamel finish with Black Enamelled hotplate. Prices on application. 88 CRANE THE IPSWICH DOMESTIC BOILER OPEN FIRE FOR HOT WATER SUPPLY DIMENSIONS Size No. Size of Hotplate Tappings Smoke A 6 C D E FH I K LM at Pipe Side* size 1 18j" x I6i" 27" isr 17*' 41" 231" 11 r 7V isr 7f 31" 17" Four 11" 41" 2 20'' X I9j" 29j" 20" 19" 4** 251" 91" 71" 20" 81" 41' 181" Four 15" 4V 3 20" x19*' 291- 2or 20J" 41" 24f 5f" 7" 261" I0f" 2V 18" Four 1^" 41" * 15" Tappings can be supplied to order on Nos. I and 2 Boilers. The No. I Ipswich Boiler is suitable for up to 30 gallons hot water storage or 25 gallons storage and Radiators up to 30 sq.ft., and the No. 2, 40gallons storage or 30 gallons and up to about 35 sq. ft. The No. 3 Ipswich Boiler is suitable for up to 50 gallons hot water storage or 35 gallons storage and Radiators up to 35 sq. ft. To ensure fuel economy it is not recommended that the above duties be increased. Stoking Tools and 5" Draw-off Cock are sent with Boilers unless otherwise instructed. See pages 96 and 97 for Measurements and Prices of Smoke Pipe and Fittings in Black and Enamel finish. For MOUNTINGS see pages 100-104. 89 CRANE REGENT DOMESTIC BOILER FOR' HOT WATER SUPPLY No. 4 ENAMELLED FINISH, AND WITH FEET RATINGS No. 5 BLACK, WITH POLISHED HOTPLATE No. Heating Surface sq. ft. Fuel Capacity cu. ft. Water Content galls. B.fh.U.s* per hour for Hot Water Supply only Gallons per hour 50-110* F. 50-130 F. 50-150 F. 4 3-63 65 6 40,000 67 50 40 5 4-55 81 8 50,000 84 63 50 * If used for Heating only the ratings are 16,000 B.Th.U.s per hour and 20,000 B.Th.U.s per hour respectively. PRICES Boiler with polished top s. d. Boiler with nickel plated top s. d. Grey Mottled Enamel Finishf s. d. Baseplate s. d. Grey Mottled Enamelled Baseplate s. d. Extra for Bower-Barffed Rustless Firepot s. d. 4 5 10 6 6 4 0 8 10 6 12 6 1 3 3 2 9 0 5 6 6 0 6 19 9 9 19 6 12 6 1 3 3 2 12 0 * Hot plate can be supplied nickel plated instead of enamelled at same price. Detachable feet for No. 4 Boiler (as illustrated): Black, 5/-; Enamelled, 10/-. Stoking Tools, 4/- extra. Cleaning Chisel, 5/10 Boilers ordered for Damper Regulator have lifting ashpit draught door and J" tapped boss on right-hand side of Boiler. 90 CRANE REGENT DOMESTIC BOILER FOR HOT WATER SUPPLY *Height Diameter Overall Size of No. to of Diameter of A 6 c D Smoke Tappings Hotplate Hotplate Baseplate Pipe 4 2ir i9r 20*" 17#" 9" 28*" I8f" L**2I" Four!*" s 25r 19*' 20*" 21|" 9" 28*" is#" 4-L" Four 1*" * Including Baseplate. Legs for No. 4 increase height 4*". All Boilers have two 35-'' dia. clean-out openings at bottom and three 2" dia. on top. APPROXIMATE DUAL CAPACITIES The No. 4 Regent Boiler is suitable for up to 50 gallons hot water storage or 40 gallons storage and Radiators up to 35 sq. ft., and the No. 5 for up to 65 gallons hot water storage or 50 gallons and up to 40 sq. ft. Stoking Tools and one *" Draw-off Cock sent with Boiler unless otherwise instructed. See pages 96 and 97 for Measurements and Prices of Smoke Pipe and Fittings in Black and Enamel finish. For MOUNTINGS see pages 100-104. CRANE THE CIRCULAR DOMESTIC BOILER FOR HOT WATER SUPPLY OR CENTRAL HEATING RATINGS No. Heating Surface sq* ft. Fuel Capacity cu. ft. Water Content galls. fi.T7i.Us per hour for Hot Water Supply only* Gallons per hour 50-110 F. 50-130 F. 50-150 F. 4C 3-63 65 5C 4-55 81 8C 6-35 1-20 9C 9-10 2-00 6 40,000 67 50 40 8 50,000 84 63 50 12 70,000 117 88 70 17 100,000 167 125 100 * If used for Heating only the ratings are 16,000, 20,000, 28,000 and 40,000 B.Th.U.s per hour respectively. . PRICES No. Boiler only s. d. Grey Mottled Enamel Finish s. d. Baseplate s. d. Grey Mottled Enamelled Baseplate s. d. Extra for Bower-Barffed Rustless Firepot s. d. Stoking Tools s. d. 4C 5 10 6 8 10 6 12 6 1 33 290 40 5C 6 6 0 9 19 6 8C 8 2 9 -- 12 6 12 6 I _3 3 2 12 0 339 40 40 9C 12 5 0 -- 1 10 -- 4 14 6 10 0 All sizes can be fitted with lifting ashpit draught door for Damper Regulator. When ordered for Damper Regulator Nos. 4C and 5C, Boilers are provided with f" tapped boss on right-hand side. 92 CIRCULAR DOMESTIC BOILER Boilers 4C and 5 C have circular waterway baffle overhanging fire. DIMENSIONS No. A B C D E F G H 1 K L M sc4C I8f" 2or 25" 4r 7f 21" 1ST 8|" 4f 5" w 28f I8f" 2or 29" 4f w 25" 23J-" I2f" 4f' 5" 6V 28f' 8C 19" 22" 43" 4f 7r 32X" 3 If' 22f' 12" 7|" 7" 34" 9C 22J" 25r 49" 5" 9" 36i" 35" 24" 14" 9" 9" 34" Stoking Tools and f Draw-off Cock sent with Boiler unless otherwise instructed. TAPPINGS AND MUDHOLES Number and Size No. Tappings Mudholes Flow Return Top Bottom Front 4C Two If Two If Three 2" Two 3f 5C Two If Two If Three 2" Two 3f _ -- 8C Two If Two If Four 2" Two 3f One 3f 9C Two 2" Two 2" Four 2" Two 3f One 3f See pages 96 and 97 for Measurements and Prices of Smoke Pipe and Fittings in Black and Enamel finish. For MOUNTINGS see pages 100-104. 93 k. CRANE---------------------------------------------:------------------------------- SECTIONAL DOMESTIC BOILER FOR SOLID FUEL Boiler No. Heating Surface sq. ft. 3 13-5 4 18 S - 22-5 6 27 7 31-5 8 36 RATINGS Heavy Firing (At 11,000 B.Th.U.s per sq.ft.) Normal Firing (At 8,000 B.Th.U.s per sq. ft.) B.Th.U.s per hour for Hot Water Supply Gallons per hour 50-100 F. 50-150 F. B.Th.U.s per hour for Hot Water Supply Go//ons per hour 50-100 F. 50-150 F. 148,500 300 150 108,000 220 no 198,000 400 200 144,000 290 145 247,500 500 250 180,000 360 180 297,000 600 300 216,000 430 215 346,500 700 350 252,000 500 250 396,000 800 400 288,000 580 290 PRICES Extra for Galvanized No. Price of Boiler Bower-Barff Rustless Process Insulated Jacket Stoking Tools s. d. s. d. s. d. s. d. 3 23 19 0 7 19 0 3 II 6 4 31 17 6 9 18 0 416 5 39 16 0 II 17 0 4 II 6 6 47 14 6 13 16 0 516 7 55 13 0 15 15 0 5 II 6 8 63 II 6 17 14 0 616 36 13 6 16 4 16 4 19 0 19 0 Prices of Oil Burning Boilers on application. Extra Middle Sections and Nipples forextending Boilers .............. each 7 18 0 Jacket Extension Pieces ......................................................................... per section 19/- 94 CRANE SECTIONAL DOMESTIC BOILER FOR SOLID FUEL No. Length of Boiler A Water Content gallons 3 20ir" 4 27$" 5 35" 6 421" 7 491" 8 56|" 270 34-8 41-6 48-3 55-0 61-8 DIMENSIONS Fuel Capacity cu. ft. Grate Area sq. ft. Smoke Pipe Size Screwed Tappings Mudholes 2-4 3-8 5-0 6-3 7-65 8-85 1-45 7" Four 3" Sixteen 4-j" 2-23 7" Four 3" Twenty 4j" 3-0 7" Four 3" Twenty-four 41" 3-8 8" Four 3" Twenty-eight 4|" 4-6 8" Four 3" Thirty-two 4i" 5-4 8" Four 3" Thirty-six 4j" All mudhole covers have joints made with india-rubber rings. Low return tappings can be supplied screwed up to 2" giving 2j" from floor to centre. Heavy and normal firing ratings are listed so that boiler may be selected according to the requirements of the installation as regards stoking attention, efficiency, etc. The normal rating is based on 8,000 B.Th.U.s per sq. ft. boiler surface, and heavy firing on 11,000 B.Th.U.s per sq. ft. Stoking Tools and one f" Draw-off Cock sent with Boiler unless otherwise instructed. See pages 96 and 97 for Measurements and Prices of Smoke Pipes and Fittings. For MOUNTINGS see pages 100-104. 95 CRANE CAST IRON SMOKE PIPES .COLLAR DIMENSIONS Ins. Ins. Ins. Ins. Ins. Ins. Ins. Ins. Ins. Ins. a. Internal diameter ... Approx, external diameter 3f 4* 4* 4* 56 7 5* 6* 7* 8 8* 10 10-2- 12 14 16 12* 14* 16* Diameter of Spigot Band 5* 6* 7* 8* 10* 12* 15* 17* HLU Internal diameter U Internal depth ... lo/> Diameter of Bends ... H 4* 5# 6* m m Mi 12* 15* 17* ... 3* 3* 3* H 3^- 4 4* 4* 4* 4* ... 5* 5* n m 0-rV 12* 14* 17* 19* PRICES BLACK 4" 4*" 5" 6" 7" 8" 10" 12" 14" 16" 2 ft. length, plain ... each 3 ft..................... ............ 4 ft............................................... 6 ft. ,, ,, ... ,, 2 ft. ,, with Check draught, etc. ... ,, 3 ft. ,, ,, ........... 4 ft............................................... Collar for Covering Plate ,, Cowl with Socket ... ,, 3/1 3/4 4/7 5/6/1 6/8 8/10 9/4 4/5 4/11 7/6 8/- 15/1 19/9 36/11 40/6 6/3 7/5 11/3 12/- 22/7 29/8 55/4 60/9 9/11 10/- 15/8 16/- 30/1 39/7 73/9 94/11/7 14/2 21/3 22/2 41/0 54/8 93/10 116/8 6/7 7/6 7/5 7/11 10/1! 11/2 9/- 9/6 13/7 13/8 1/8 I/ll 2/- 2/1 4/10 5/8 6/7 9/1 2/2 -- -- -- -- 9/5 11/3 15/1 19/5 -- -- -- VITREOUS ENAMELLED* 2 ft. length, plain 3 ft..................... ... each 7/1 8/7 12/6 12/10 ... ,, 10/8 12/11 18/9 19/3 4 ft............................................... 14/3 17/3 25/- 25/8 6 ft. ,, ,, ........... 19/4 25/2 37/6 38/- -- -- -- -- -- 2 ft. ,, with Check draught, etc. ........... 10/8 13/7 3 ft..................... ........... 14/8 17/9 24/1 25/4 4 ft............................................... 17/10 22/1 31/3 31/9 Collar for Covering Plate ,, 2/S 2/7 3/1 3/3 -- Smoke Pipes 5" to 12" inclusive, are manufactured to British Standard Specification No. 41. * See note at foot of page 97. 96 CRANE CAST IRON SMOKE BENDS DIMENSIONS ELBOWS WITH SOCKETS ONLY. Internal diameter .. Face of socket "1 90 to centre of > Elbows spigot J only Face of spigot to centre of spigot Centre to centre of offset internal diameter of socket Internal depth of socket 4" 7f' 7r 6" 4F 3" 4*" Sy" 8" 6" 54" 3" 5* 6" 77" ar 10" ir __ sr 6f" 3F 34" 7" 9*" 8" ior 10" 12" 14" 16" 12*' I3" 14*" 16*' 12" 13" 15" 17" 19" 21" _ ___ _ 74F 8+F nr 13*" 15*" 17*' 4" 4F 4*" 4F 4F PRICES BLACK ENAMELLED* 4" 4F 5" 6" 7" 8" 10" 12" 14" 16" 4" 4r 5" 6" Bends (90) with door .. .. ,, ,, with 2 spigot ends .. ,, (135) with door .. .. ,, ,, withspigotend I2"lg. ,, ,, with two spigot ends, one 12" long .. ,, (I I2) with door .. ,, ,, withspigotend 12" Ig. ,, ,, with two spigot ends, one 12" long -. Offsets, 6" projection .. .. Adaptor to 6" size .. .. 4/10 5/8 ---- 4/10 5/8 7/6 8/9 __ -- 4/10 5/8 7/6 8/9 ---- 5/1 5/8 2/1 6/11 8/5 11/3 11/8 25/9 36/3 56/6 94/10 9/6 10/6 12/6 15/11 10/3 13/4 --- -- -- -- -- -- -- -- 21/4 6/11 8/5 11/3 11/8 25/9 36/3 56/6 94/10 9/6 10/6 12/6 15/M -- -- -- -- -- -- -- 12/6 14/1 -- -- 14/2 18/2 -- -- __ -- -- 6/11 8/5 11/3 13/2 -- -- -- ---- -- -- -- -- -- 21/2 26/1 -- 9/6 10/6 12/6 15/11 -- 12/6 14/1 -- -- 14/2 18/2 -- -- -- -- -- -- -- -- 21/2 26/1 -- -- -- -- -- -- -- -- 10/4 11/6 -- -- 3/9 * Prices for enamelled smoke fittings are for Grey Mottle only Plain green, plain brown and black 25% extra on Enamelling Charge. 97 G r CRANE BOILER FITTINGS SOCKET OUTLETS Figs. 842, 843 and 844 HOT WATER SOCKET ELBOW, FLANGED, FLOW TO SIDE OR VERTICAL RETURN Figs. 845,846 and 847 HOT WATER SOCKET . STAND-PIPE, FLANGED, FLOW OR RETURN Figs. 848,849 and 850 HOT WATER SOCKET ELBOW, FLANGED, FLOW TO REAR OR HORIZON TAL RETURN Fig. 851 HOT WATER STRAIGHT SOCKET, SCREWED DIMENSIONS AND PRICES Fig. 852 HOT WATER ELBOW SOCKET, SCREWED Size for Fig No. "Whitehall" Boiler A 8 C D H Price 842 4" for No. 2 m" 4" 7_3_" 10/8 843 4" ,, No. 3 & 4 sir -- -- -- 4--" 7t' 10/8 844 14/1 845 4" ,, No. 2 -- 4" 6r -- -- 6V 7/2 846 4" ,, No. 3 & 4 -- 4" 6r -- -- 6V 7/2 847 5" ,, ,, ,, 848 4" ,, No. 2 sir -- 849 4" ,, No. 3 & 4 8tr -- -- -- 10/8 -- -- 4" 4*" 77'I_T23 _"" 10/8 10/8 850 14/1 851 3" ,, No. 1 -- 4" w 2" -- 6" 4/3 852 3" ,, No. 1 5#* 5r 2" 6/7 The above prices are for these fittings when supplied separ ately. In the case of Series Nos. 2, 3 and 4 Whitehall Boilers, when ordered in lieu of ordinary tapped flanges Fig. Nos. 845, 846 and 847, are supplied at no extra charge, and Figs. 842, 843, 844, 848, 849 and 850 are supplied at 50 % of the above prices. 98 k. BOILER FITTINGS CRANE FLANGED OUTLETS Figs. 853, 354 and 859 Figs. 857, 858 and 861 Figs. 855, 856 and 860 FLANGED ELBOW, SIDE FLOW OR VERTICAL RETURN FLANGED STAND-PIPE FLANGED ELBOW, FLOW TO REAR OR HORIZON TAL RETURN. DIMENSIONS AND PRICES FigNo. Size for "Whitehall" Boiler A E H Price , 853 4" for No. 2 7" 7" II*' 14/- 854 4" ,, No. 3&4 8" 8" 12*' 14/- 859 5" No. 3&4 8" 8" 13" 25/- 855 4" ,, No. 2 -- -- 856 4" ,, No. 3 8<4 -- -- 860 5" ,, No. 3&4 -- -- 6" 5" 6" II/- II/14/6 857 4" .. No. 2 7" 7" II*' 14/- 858 4" ,, No. 3&4 8" 8" 12*' 14/- 861 5" ,, No. 3&4 8" 8" 13" 25/- 862 3" ,, No. 1 -- -- -- 4/3 All outlet flanges are to British Standard Table D 3" C.I. THREADED FLANGE FOR No. I WHITEHALL BOILERS 99 Fig. 862 CRANE CRANE SPRING RELIEF VALVES Fig. H23I Suitable for use with all hot water heating and hot water supply boilers. Valve and seat of non-corrosive metal. DESCRIPTION Full bore lock-up spring relief valve suitable for both hot water heating and hot water supply boilers. Constructed of gun metal with stainless steel spring. Valve guide is situated well above inlet and is therefore unaffected by scale. The valve can be tested by rotating or lifting and a tapped boss is provided for draining above seat. NOTE.--Tank height must be specified when ordering. Sizes: Ratings .. Prices .. i" up to 400,000 B.Th.U.s 1 13 6 I" up to 800,000 B.Th.U.s 1 15 6 IF ' IF up to 1,200,000 up to 1,500,000 B.Th.U.s B.Th.U.s 2 5 0 2 16 0 2" above 1,500,000 B.Th.U.s 3 17 6 GUN METAL SAFETY VALVES Sizes: Standard Pattern to blow off at 30 feet head 43" 1" ir r 2" 14/- 16/- 20/3 24/- 33/9 Extra for Weights to increase resistance by 5 feet.......................... -16 -IB -19 1/- 1/3 DEADWEIGHT PATTERN CAST IRON WEIGHTS SPRING PATTERN G.L.C. PATTERN Fig. H242 FOR PRESSURES FROM 30 FT. TO 45 FT. HEAD OF WATER Fig. H226 DESIGNED TO LIFT AT 28 LBS. PRESSURE Fig. H225 DESIGNED TO LIFT AT 25 LBS. AND 50 LBS. Size: H 226 H 225 V 3/6 -- 430 1" 3/9 4/7 12/6 -- ENCLOSED DEADWEIGHT SAFETY VALVES FOR HEATING AND HOT WATER BOILERS Fig. H 245 Size No. i la lb 2 2a 2b X3 X3a X3b 3 3a 3b X4 X4a X4b 4 4a 4b Socket Screwed Gas Tank Height in feet 3" 4 35 4 50 3" 4 70 3// 4 60 3" 4 80 3 4 110 1" 60 J // 80 no 1 " 60 80 110 60 ir 80 i r no i r 60 ir 80 ir no Radiating Capacity in sq. ft. 50 to 700 700 to 3,000 3,000 to 6,000 6,000 to 8,000 8,000 to 11,000 11,000 to 16,000 Price of Valve s. d. i 14 6 i 14 6 i 19 6 2 II 6 2 II 6 2 15 6 45 6 456 4 12 6 556 556 5 16 0 7 13 0 7 13 0 8 18 0 9 19 0 9 19 0 II 16 0 Price of Valve with Padlock s. d. i 15 6 i 15 6 206 2 12 6 2 12 6 2 16 6 466 466 4 13 6 566 5 66 5 17 0 7 14 0 7 14 0 8 19 0 10 0 0 10 0 0 II 17 0 "NABIC" ENCLOSED SPRING SAFETY VALVES Size Size of Inlet and Outlet Radiating capacity of Boiler for which Valve is suitable Price of Valve with Padlock s. d. 17 gas thread Up to 100,000 B.Th.U.s 1 6 0 18 43" it ,, ,, 500,000 ,, 1 13 0 19 ,, ,, 900,000 ,, 270 20 1 41" it it 21 1* 12" * ) ,, ,, 1,300,000 ,, ,, 1,800,000 ,, ,, 2 14 0 440 22 2" ,, ,, ,, ,, 3,200,000 ,, 520 Note.--Tank height must be specified when ordering. See page 107 for Safety Valves for Low-Pressure Steam Heating Boilers. 101 CRANE THERMOMETERS MERCURY WELL 1 Fig. EI70. Fig. EI7I. Straight. Angle. 8/- each. 9/- each. Iron--White enamelled. Screwed Y male. Scale--6" AngleThermometers similar to E173 but with scale at side:-- Fig. E195, left hand\ Fig. El96, right hand/ Price 19/6 each. Fig. E191. For use with figs. El76, El77 and El 78. Screwed male 1" Female Price 5/6 each. Fig. EI72. Fig. EI73. Straight. Angle 12/- each 17/- each. Polished brass case with Opal scale. Screwed Y male. Scale--5". "THERINDEX ' Fig. E204. Price 12/6 Diameter 2f". For clipping to flow-pipe near boiler. Supplied nickel plated complete with bolt and nut and adjusting key. In sizes for pipes up to 2", 3" and 4". Fig. El76. Fig. El86. Straight. Angle. Fig. El77. Fig. El87. both above with revolving shield. EI76 EI77 EI86 EI87 8" 20/22/32/34/- 10" 24/27/- 36/39/- EI78 EI88 19/3 26/6 New H.M.O.W. Pattern. 5j" Cast Brass Frame. Opal Scale. Range 40/260 Fahr. NOTE.--It is necessary to fit a mercury well (Fig. El91) with Figs. E176, E177, and E178 102 t BRASS CASE CRANE THERMOMETERS CIRCULAR DIAL MERCURIAL PATTERN Angle Pattern is fitted with Patent Detachable Brass Cup Sockets which allow the Thermometer to be screwed into position without re moving the Dial. Dial reading from 30 to 260 Fahr. 6" Dial reading from 30 to 260 or up to 500 Fahr. PRICES Fig. No. Description Dial: 4" 6" E200 E20I Vertical Pattern with 1" steel Mercury Well .............. Angle Pattern with i" Patent Detachable Brass Cup Socket ......................................................................... 44/ 35/6 59/ 51/6 ) ALTITUDE GAUGES COMBINED ALTITUDE GAUGE AND H.M.O.W. TYPE THERMOMETER ALTITUDE GAUGE i Diameter of dial .......................... 3j" Screwed Price ... 18/6 each Temperature range 60F. to 260F. Graduated up to 70 ft. head. Can be supplied for any greater head at slightly increased charge. Fig. E2I5. Diameter of dial ........................... 6" Brass Case with flanged back, H.M.O.W. Specification, screwed " Price ... 30/- each Cock, Fig. E97, 3/10 extra Marked in feet head of water and lbs. per square inch, can be supplied graduated to 40 ft., 70 ft., 100 ft., or 150 ft. See General Catalogue for additional altitude and vacuum gauges. 103 CRANE DRAW-OFF COCKS PLUG COCKS GUN METAL MALE AND HOSE UNION GLAND COCKS* GUN METAL FEMALE AND HOSE UNION Fig. D342. Sizes ins. ... i 34. 1 Fig. D342 ... 4/- si- 8/- -- -- ,, D344 ... V- 9/- II/- 16/3 24/6 ,, D345 ... V- 9/- II/- 16/3 24/6 ,, D343 ... 1/10 -- -- -- Prices for stamping Fig. D345 are extra-- see separate price list Fig. D344. Fig. D345 Stamped " M.W.B." DRAW-OFF PLUGS BRASS Fig. D343 Size Fig. 995. Gas Poker for Crane Ips wich and Carlton Boilers, complete with length of flexible tube and rubber connection Price each - 4/6 Fig. 996. Connecting Plug and Socket, as shown on the left, recommended instead of the rubber connection. Fig. 995 Price each - 7/10 * See page 123 for female end gland cocks. 104 CRANE STOKING TOOLS Crane specially designed hardened Scraper for Whitehall Boilers. PRICES AS TABLE Clinker Tongs for Small Boilers. Small, I' 10* long, 2/3 each. Large, 2' 3" long, 3/- each. Spare Flue-brush Heads. No. I and 2 Whitehall Boilers, 2/6 each No. 3 and A Whitehall Boilers, 3/- each For Whitehall Boiler with Rack. HEATING BOILERS Boilers No. Shovel .. Poker .. Slicer .. Flue Brush .. Scraper .. Clinker Hook Hoe .. .. Complete Set CARLTON ------------------------------ - WHITEHALL 03--05 s. d. 14--15 16--17 18 06--07 104--105 I4LW--15LW 106--109 24--25 24 LW--25 LW I6LW--I7LW 26--27 26 LW--27 LW I8LW--I9LW 35--36 28--29 35LW--I9LW 28 LW--29 LW s. d. s. d. s. d. s. d. s. d. s. d. 20 16 16 26 16 90 20 19 19 26 50 23 23 26 19 99 23 14 3 69 18 18 36 22 50 18 19 0 69 2 10 2 (0 3 II 28 50 2 10 21 3 69 46 46 43 36 50 46 24 0 90 27 27 39 22 50 27 22 6 Boilers No. Shovel .. Poker .. Slicer .. Flue Brush* .. Scraper .. Clinker Hook Hoe .. .. Complete Sec 37--38 37 LW--38LW 39--310 39 LW--3I0LW 311--312 311 LW-- 3I3LW 47--48 47 LW--48 LW 49--410 49 LW--4I0LW 411--415 41 [LW-- 4I6LW s. d. s. d. s. d. 5. d. s. d. s. d. 90 46 46 40 36 50 46 26 0 90 66 66 . 59 50 50 66 31 6 90 66 66 70 60 50 66 33 6 90 50 50 49 43 50 50 28 0 90 66 66 66 59 50 66 32 6 90 66 66 70 60 50 66 34 0 * With the Nos. 3 and 4 Whitehall Boilers a second flue head is provided without extra charge. DOMESTIC BOILERS Boilers No. Poker .. Complete Set 3--5 Sect. Sect. Sect. 00 01 1--2 lc.5c. 8c. 9c. 3--5 6--7 8 -18 -no 1/2 112 1/2 4/8 6/9 6/9 6/9 -18 18 -18 -18 -18 -18 -18 -18 1/5 3/3 4/1/3 -- -- 5/6 -- ____ -- 1/6 -- -- 3/3 4/- 5/6 ___ ___ 1/6 2/8 3/3 At- 5/5 1/4 1/6 2/6 4/- 4/- 10/- 13/6 16/4 19/- STOKING TOOL RACKS For Whitehall Boilers ,, Carlton ,, 8/6 each. 7/- For Carlton Boiler 105 CRANE CRANE DAMPER REGULATORS FOR HEATING AND HOT WATER SUPPLY BOILERS 1 Can be fixed on top, front, or side of Boiler. Fig. 865 DAMPER REGULATOR (Patent No. 387,897) Screwed Price complete 14 6 Chromium Plated, 2/6 extra. PROVISION FOR FIG. 865 REGULATOR ON BOILERS Carlton Boilers have " tapping on face of front section. Regent Boilers have " boss on right-hand side of boiler. Circular Domestic Boilers have a f" tapping in clean-out cover. Fig. 866 DAMPER REGULATOR (Screwed 1^") Price complete - 18 6 Range I00F-240F. Chromium Plated 3/6 extra 106 CRANE CRANE DAMPER REGULATOR FOR LOW PRESSURE STEAM BOILERS This Regulator is ^designed for opening and closing the ashpit draught door alone, or together with the smokehood check draught on Low-Pressure Steam Boilers. Can be adjusted to operate at any pressure between zero and the pressures per square inch given below. Fig. 868, Screwed I", for pressures up Fig. 869, ,, r. .. - AUTOMATIC BOILER FEEDER The McDonald Miller Automatic Boiler Feeder has a considerable advantage over other types in that the raw feed water does not come in contact, under heat, with the valve seat. Thus possi bility of scale causing failure of opera tion is eliminated Size of inlet from cold supply ... Connections to Boiler ............... I" Price ... 6 13 6 "POP" SAFETY VALVES FOR LOW PRESSURE STEAM HEATING BOILERS MALLEABLE IRON BODY. GUN METAL SEAT AND DISC SET TO LIFT AT 5, 10, OR 15 LBS. PRESSURE Size ins. 43" r <v IV 2" 7"L2 " _Fig. H2II 18/9 21/- 25/6 34/6 -- FigH2I3 16/- 18/- 111- 25/6 33/- 57/6 Fig. H2I3. These Safety Valves were specially designed for use on low-pressure steam heating boilers, and are widely employed for this purpose. Please state required pressure when ordering 107 CRANE TOWEL AIRERS CHROMIUM PLATED Fig. 870 Fig. 871 Dio. of Tube in. i i i i* i* i* i* i* i* Width in. 30 36 42 30 36 42 30 36 42 Height in. 36 36 36 36 36 36 36 36 36 Fig. 870 s. d. 2 113 2 12 9 2 14 3 2 16 6 2 18 3 300 3 10 3 3 13 3 3 16 3 Fig. 871 s. d. 2 19 30 32 34 36 38 40 43 46 3 9 3 9 6 3 3 3 3 Made from I8G. Solid Drawn Brass Tube and tested 100 lbs. Hydraulic. Nickel Plated before Chromium Plating is applied. Height to bottom tappings 4", tappings supplied " size pointing outward unless otherwise instructed. Diameter of floor flanges, 3" on I", 3j" on !", 4" on 1^". Distance from wall to centre of rail, Fig. 871, 6". NOTE.--Towel Airers of similar design to Fig. 870, constructed of Galvanized Tubes with ball fittings can also be supplied. Prices on application. 108 TOWEL AIRERS CHROMIUM PLATED CRANE Dia. of Tube in. i i i i i i* i* i* i* i* i* i* Width in. 30 36 42 36 36 30 36 42 36 36 30 36 42 Height in. 36 36 36 24 30 36 36 36 24 30 36 36 36 Fig. 872 s. d. 323 343 363 -- -- 393 3 12 0 3 14 9 -- -- 493 4 13 3 4 17 3 Fig. 873 s. d. _ -- -- 303 313 -- -- -- 3 10 0 3 113 -- -- -- Made from I8G. Solid Drawn Brass Tube and tested 100 lbs. Hydraulic. Nickel Plated before Chromium Plating is applied. Height to bottom tappings 4" on Fig. 872, tappings supplied " size pointing outward unless otherwise instructed. Diameter of floor flanges, 3^" on I", 3^" on l", 4" on l-j". Distance from wall to centre of rail is 6" on Fig. 873. 109 r CRANE--------------------------------------------------------------- TOWEL AIRERS CHROMIUM PLATED Fig. 879 Dio. of Tube in. i Width in. 30 Height in. 36 Fig. 874 s. d. 1 17 9 Fig. 879 s. d. 239 Made from I8G. Solid Drawn Brass Tube and tested 100 lbs. Hydraulic. Nickel Plated before Chromium Plating is applied. Height to bottom tapping 4", tappings supplied J-" size pointing outward unless otherwise instructed. Diameter of floor flanges, 3". Fig. 875 TYPE Dia. of Tube in. Circulating ........................... Non-circulating.......................... i i Width in. 36 36 Fig. 875 ,s. d. 1 06 17 9 With circulating type, " size connections are provided through wall. Distance from wall to centre of rail is 6" on Fig. Nos. 875 and 879. 110 i CRANE TOWEL AIRERS CHROMIUM PLATED HEXAGONAL TUBES Fig. 877 as Fig. 876 but with double top similar to Fig. 872. Across Flats in. 1* 1* 1* Width in. 30 36 42 Height in. 36 36 ' 36 Fig. 876 s. d. 583 5 12 0 5 15 6 Fig. 877 s. d. 6 14 9 6 19 9 749 Fig. 878 s. d. 639 673 6 11 0 Made from Solid Drawn Brass Tube and heavy cast gun metai fittings. Nickel Plated before Chromium Plating is applied. Height to bottom tappings 4", tappings supplied f" size pointing outwards unless otherwise instructed. Diameter of floor flanges, 3J". Distance from wall to centre of rail is 6" on Fig. 878. m i L A CRANE RADIATOR TOWEL AIRERS CHROMIUM PLATED Fig. 886 Fig. 887 Dio. of Tube in. Width in. Height in. Approx. Heating Surface Fig. 886 s. d. Fig. 887 s. d. 1 i 30 36 8* 4 12 3 5 0 3 1* 1i 36 36 9 4 IS 9 539 42 36 9'2 4 19 3 5 7 3 Extra for Radiator in rustless Bower-Barffed Process, II/- Made from I8G. Solid Drawn Brass Tube and tested 100 lbs. Hydraulic. Nickel Plated before Chromium Plating is applied, except Radiator which is suitably treated. Height to bottom tapping 4", tappings supplied f" size pointing outward unless otherwise instructed. Diameter of floor flanges, 3". 112 CRANE TOWEL AIRER SUNDRIES CHROMIUM PLATED AND POLISHED VALVES AND UNIONS Fig. D202 WITH LOCK SHIELD - Fig. D243 STRAIGHT UNION Fig- D20I D202 D22I D222 X" 4/10 4/10 6/1 6/1 3" 6/2 6/2 7/8 7/8 \" 7/5 7/5 9/5 9/5 WALL STAYS Fig. D22I COMPOSITION WHEEL Fig. D222 WITH LOCK SHIELD D24I 2/1 2/8 3/4 D243 1/10 2/5 3/4 FOR ROUND TUBE FOR HEXAGONAL TUBE Fig. No. 895 896 Length, wall to centre of rail 1" i Up to 8" It II 10/- 10/6 16/6 When ordering state length required--Stock length, 6" ir n/- FLOOR FLANGES Fig. No.................... 897 899 J" size, per pair ... 41- 2/2 900 2/7 Fig. 897 These Flanges and Sleeves fit over wrought iron Pipe Connections and the height of Fig. 897 is suitable for use with our Fig. D20I Angle Valve and Fig. D24I Elbow Union. Fig. 899 FOR ROUND TUBE TOWEL AIRERS OR ROUND TUBE AIRERS Fig. 900 FOR HEXAGONAL TUBE 113 H CRANE RADIATOR AIR VALVES , HOT WATER Fig. E50 Fig. E53 Fig. ESS Fig. E56 Fig. E57 No. E50 Per dozen E53 II ESS It E56 ES7 E60 II Size ... * Polished Brass 61" 1 4 9/ 10/ 5/8 6/3 9/2 9/8 5/2 5/8 61 2/6 2/6 Nickel Plated 8\" 1 // 4 10/ H/6/3 6/10 9/8 10/2 5/8 6/2 6/6 3/8 3/8 Chromium Plated V JL" 4 17I2 12/ 7/9 T10/6 6/6 475 7/6 4/5 < -OC jr: Fig. E60 Fig. E66. POLISHED BRASS SCHOOL BOARD PATTERN WITH BIB NOSE Size 1 /' 8 J f> 4 Price each ... 3/- j 3/2 Fig. E66 AIRLET PLUGS CAST IRON GUN METAL CRANE AUTOMATIC AIR VALVE FOR VENTING HOT WATER HEATING AND DOMESTIC SYSTEMS Fig. 925 Fig. 926 Size Fig. 925 ... each ,, 926 ........... 1" -/ 2/4 ir 1/1 2/6 Fig. 925. Airlet Plug supplied free on all Radiators save Copper. Fig. 926. Gun Metal Airlet Plugs. Customers' name can be cast on free of charge for lots of 50. 114 Fig. HIOI Size 2 Price ... 42/- 3" 4 86/6 CRANE HOFFMAN AUTOMATIC AIR VALVES FOR STEAM RADIATOR AIR VALVE i" CONNECTION Fig. E70 Price ............... 8/6 For pressures 0-10 lbs. RADIATOR SYPHON AIR AND VACUUM VALVE i" CONNECTION Fig. E70. Recommended for installations where moderate initial cost is desirable. It is similar in operation to the widely used E75, but has not the adjustable Venting Port. This valve is suitable for lowpressure steam heating systems up to 10 lbs., but not for vapourvacuum systems. RADIATOR SYPHON AIR VALVE i" CONNECTION Fig. E75. Designed for all sys tems of low-pressure steam. Through its use all air is vented from the radiator without loss of steam, and maximum heating efficiency is assured. After con tact of water with the valve the syphon drains all water from the valve, and venting occurs with out the slightest "spit" even if the radiator is under pressure. Fig. E78. Similar in construction to the No. E75, but in addition, when the radiator is once freed from air, return of air through the vent port is prevented. It is thus particularly suitable for vapour-vacuum systems. Fig. E7S Price ... 14/ For pressures 0--10 lbs. QUICK VENT FLOAT AIR VALVE CONNECTION Fig. E78 Price ............... 28/ For vacuum or pressures up to 10 lbs. The E80 Automatic Air Valve is intended for venting the main steam pipe-line in low-pressure steam heating systems up to 10 lbs. working pressure. For 3--10 lbs. pressure the valve has a -fa" port and for 0--3 lbs. a ts" port. When ordering specify port size. Fig. E80 Price ... 59/- 115 CRANE RADIATOR VALVES with EASY CLEAN SHIELDS ANGLE VALVES Fig. D201 COMPOSITION WHEEL Fig. D241 ELBOW UNION Fig. D202 LOCK SHIELD Fig. D203 WITH CLOSED SHIELD GATE VALVES Fig. D22I COMPOSITION WHEEL Fig. D222 LOCK SHIELD Fig. D223 WITH CLOSED SHIELD Fig. No. Size D201-2-3 Matt Finish........................... > Polished ........................... ,, Nickel Plated on Polished Chrom. Plated on Polished D22I-2-3 Matt Finish.......................... Polished ........................... ,, Nickel Plated on Polished ,, Chrom. Plated on Polished D24I ,, Matt Finish.......................... Polished ........................... Nickel Plated on Polished Chrom. Plated on Polished 21" 1" 3/5 3/6 4/6 5/3 4/- 4/1 5/4 6/5 4/5 4/6 5/9 6/11 4/9 4/10 6/2 7/5 4/5 4/8 5/10 7/3 5/- 5/3 6/9 8/5 5/4 5/7 7/3 9/1 5/10 6/1 7/8 9/5 -- 1/3 1/7 2/1 -- 1/8 2/1 2/8 -- _ 1/10 2/4 2/1 2/8 2/11 3/4 ir 2" 6/10 8/5 9/0 9/10 9/3 10/10 11/5 12/1 3/1 3/11 4/2 4/7 _ -- -- -- 20/- 22/2 22/10 23/5 6/9 7/10 8/2 8/7 _ -- _ -- 29/6 32/2 33/3 34/8 9/9 11/2 11/6 12/2 116 RADIATOR VALVES CRANE Fig. D238 COMPOSITION WHEEL Fig. D239 COMPOSITION WHEEL Fig. D243 STRAIGHT UNION Fig. D2I2 COMPOSITION WHEEL RIGHT HAND CORNER VALVES Fig. D2I3, as Fig. D2II WITH LOCK SHIELD Fig. D2I4, as Fig. D212 WITH LOCK SHIELD Fig. D2II COMPOSITION WHEEL LEFT HAND Fig. No. \ 2 24." Each \" i r D238 D239 D2II -2-3-4 l ,, D243 ,, II With Composition Wheel* ,, ,, ,, Matt Finish .............. Polished .......................... Nickel Plated on Polished Chrom. Plated on Polished Matt Finish ............... Polished .......................... Nickel Plated on Polished Chrom. Plated on Polished 6/6 6/6 12/2 12/9 13/1 13/7 1/3 1/6 1/8 1/10 7/6 7/6 14/1 IS/- 15/6 15/11 1/7 I/ll 2/3 2/5 11/6 11/6 18/7 19/9 20/5 20/9 2/1 2/6 2/11 3/4 14/14/- 25/9 27/4 28/3 29/- 3/1 3/7 4/1 4/6 ir 2" ---- ---- ---- ---- -- --- ' 6/9 9/9 7/5 10/9 8/- 11/4 8/7 12/- * Figs. D238/9 can be supplied Polished, Nickel Plated on Polished, or Chromium Plated on Polished. Prices on application. 117 r1 CRANE RADIATOR VALVES GATE VALVES (FEMALE ENDS) EASY CLEAN HOFFMAN ADJUSTABLE MODULATING VALVE Fig. D23I COMPOSITION WHEEL Fig. D232 Fig. D233 WITH CLOSED SHIELD Fig. D78 Fig. D240 FOR "PALL MALL" RADS. Fig. D242 FOR HOSPITAL RADS. WITH COMPO. WHEEL CONCEALED VALVES Fig. D240 FOR "PALL MALL" RADS. Fig. D242 FOR HOSPITAL RADS. WITH LOCK SHIELD Fig. No. Each 2\" 43// 1" ir '** V D231-2-3 J> " > D240/2 ft D240/2 D78 Matt Finish ............... Polished .......................... Nickel Plated on Polished Chrom. Plated on Polished With Compo. Wheel-- Polished Brass ............... Chromium Plated ... With Lock Shield-- Polished Brass ............... Chromium Plated ... 4/6 5/4/11 5/7 S/4 6/1 5/6 6/5 -- -- "" -- -- -- -- -- -- 27/- 6f- 7/6 6/11 8/9 7/4 9/1 7/7 9/6 7/3 9/4 8/10 11/2 7/3 9/4 8/10 11/2 -- 10/3 11/10 12/1 12/7 13/6 15/4 16/16/il ---- ---- -- -- ---- ,-- Prices of Concealed Valves include fitting blind nipple to Radiator. LOCK SHIELD KEY Fig. D260 Price ... No. I -/7, No. 2 -/8, No. 3 -/9 When ordering state size of valve for which key is required. I 18 kJ af D20I RADIATOR VALVES DIMENSIONS r~i 1---c----u1 D202 D203 -|SEF Cj-J D22I CRANE n -sgW f-K*r--L~*n D222 D223 D236 D237 D240 D242 r CRANE GUN METAL VALVES GATE VALVES Fig. D236 COMPOSITION WHEEL Fig. D237 LOCK SHIELD Fig. DI5I IRON WHEEL Fig. DI60 IRON WHEEL (B.S. Tables D and E) Sizes: 1n 4 83" 3" 4 1" IF IF 2" 2412 " 3" D236-7 Matt Finish DI5I ............... DI60 ............... 41 5/ 6/3 3/10 3/10 3/10 4/9 8/1 10/- 14/6 61 7/8 | 9/5 13/10 22/4 27/10 15/- 22/6 26/6 37/- 51/3 63/- Flanged valves are supplied undrilled unless otherwise ordered. Drilling charge 2d. per hole. 120 GUN METAL GATE SOLID TAPER DISC STAMPED "M.W.B." CRANE VALVES 1 Fig. DI63. SCREWED Fig. DI64. FLANGED B.S. TABLES D & E Fig. No. Sizes: 21 " 43'/ 1" ir 1 1" 2" 2L2 " 3" DI63 Price ... 4/5 51- 6/5 8/10 11/4 15/- 25/3 32/- End to End ... 2" U" 2*' 2-2." 3" 3T W H" DI64 Price ... _ 15/- 22/6 26/6 37/- 51/3 63/- I Face to Face ... -- -- w w 4" 5" 5y 6&" The fee for stamping by the Metropolitan Water Board is extra to the above prices l See separate price list. Flanged valves are supplied undrilled unless otherwise ordered. Drilling charge 2d. per hole. THROTTLE VALVES WITH INDICATOR PLATE FOR HOT WATER Sizes: \" ir w Prices 11/8 14/- 20/- i j t ............... . 1.... ....... J i Fig. D76 .......... .1 ---i 121 . A CRANE GUN METAL GLOBE VALVES Fig. Dl FOR STEAM WORKING PRESSURES UP TO 200 POUNDS AND Figs. D5 and D6 UP TO 125 POUNDS PER SQ. IN. Fig. Dl Screwed GUN METAL DISC Fig. D5. Screwed Fig. D6. Flanged RENEWABLE DISC Sizes: 41 " r i" 43// 1" 1 i" 1V 2" 2V 3" Fig. Dl ... 2/3 2/6 3/4 4/6 6/8 9/2 11/9 16/9 29/6 47/6 Fig. D5 ... 4/- 4/4 4/8 5/- 9/6 12/6 19/6 -- -- Fig. D6 ... 10/- 11/6 15/6 23/3 27/6 41/6 FOR STEAM WORKING PRESSURES UP TO 200 POUNDS PER SQ. IN. UNION BONNET AND SLIP ON RENEWABLE DISC Sizes: 41 " Fig. D7. Screwed Fig. D8. Flanged B.S. Table E. Fig. Dll .. ,, ,, F. 83ft 2\ 43 I" |12 " 2" 21" 3" Fig. D7 ... 5/- 5/8 7/6 10/ 12/6 18/ 23/9 36/3 61/6 91/6 Fig. D8 ... 15/- 19/- 25/6 34/6 45/ 73/6 105/ 140/ Fig. Dll 28/6 37/6 48/- 81/- 117/- 155/- Renewable Disc Valves are provided with discs for steam, hot water, cold water, oil or compressed air. Please state on order which is required. Flanged Valves are supplied undrilled unless otherwise ordered. Drilling charge 2d. per hole. F CRANE SWING CHECK VALVES MAY BE USED IN A HORIZONTAL POSITION OR FOR UPWARD FLOW FOR STEAM WORKING PRESSURES UP TO 125 POUNDS WATER WORKING PRESSURES NON-SHOCK UP TO 200 POUNDS Sizes: 3" 2 3" 4 1" ir 2" 2i" 3" DI38 4/2 4/4 5/4 6/6 8/8 11/8 16/- 26/- 43/- With Gun Metal Disc DI39 4/9 s/- 6/3 7/9 10/6 14/6 19/6 33/- 53/- Fig. DI38 Fig. DI40 DI40 4/2 4/4 5/4 6/6 8/8 11/8 16/- 26/- 43/- Stamped "M.W.B." DI4I 4/9 5/- 6/3 7/9 10/6 14/6 19/6 33/- 53/- The fee for stamping "M.W.B." valves is extra. See separate price sheet. With Leather Faced Disc Fig. DI39 Fig. DI4I Stamped "M.W.B." PLUG COCK Fig. D300 Female Fig. D30I M. and F. PLUG and GLAND COCKS FOR STEAM WORKING PRESSURES UP TO 125 POUNDS Sizes: 21 *3// 1" ir D300/I 3/7 4/7 6/2 9/10 D320/I 4/8 6/- 9/- 12/6 GLAND COCK Fig. D320 Female Fig. D32I M. and F. Sizes: ir 2" 2*' 3" D300/I D320/I 12/6 19/2 35/- 52/6 15/6 23/- 46/- 64/- 123 F1 CRANE RADIATOR TRAPS THE "HOFFMAN" FOR STEAM WORKING PRESSURES UP TO 15 POUNDS Fig. H74 Angle Price 1/2/0 Hoffman Radiator Traps freely relieve air and con densation from radiators in Low Pressure, Vapour or Vapour-Vacuum systems without steam loss. They are also used as steam traps in industrial work and for cooking apparatus, sterilisers, etc., where pressure does not exceed 15 pounds. Hoffman Traps are absolutely non-adjustable, and thermostats can be changed from one body to another without "setting." Made in size only, capacity 200 sq. ft. The Fig. H77 vertical trap is recommended for concealed Radiators having bottom outlet or for draining other vessels with similar connections. Capacity 200 sq. ft. of direct radiation. Maximum working pressure, 15 pounds. Price 1/2/0 Fig. H77 Vertical THE " DRICO '' FOR STEAM WORKING PRESSURES UP TO 30 POUNDS Sizes : 2\'f 43// Capacities in sq. ft. radiation ... 400 560 Price ............... 20/- 25/- Capacities are based on I lb. differential pressure over trap. To obtain capacity in Ibs./hour, i divide by 4. Allow 2.1 margin. Fig. H70 Straight Fig. H7I Angle 124 CRANE CRANE INVERTED OPEN FLOAT STEAM TRAPS IRON BODY WITH GUN METAL WORKING PARTS DISC AND SEAT OF STAINLESS STEEL FOR USE ON STEAM HEATING SYSTEMS FOR DRAINING COILS AND FOR DRIPPING MAINS OR RISERS INTO RETURNS FOR PRESSURES UP TO 200 LBS. Crane Inverted Open Float Steam Traps fill a long-felt demand for an inexpensive yet efficient trap for draining heating coils, unit heaters, and a variety of steamheated apparatus used in indus trial cooking and laundry plants. Figs. H50 and H5I Fig. H52 PRICES AND CAPACITIES. POUNDS OF CONDENSATION PER HOUR No.: Size: Effective pres sure at Trap in lbs. per sq. in. 5 10 2105 25 30 40 50 60 75 (00 125 210500 Price: H.50 r 915 880 (.080 790 845 960 610 680 530 600 405 450 460 325 37/- H:5I v 3,050 3,500 4,300 3,(00 3,350 3,800 2,450 2,700 2,050 2,250 2,650 1,850 2,050 1,300 491- r (0,400 9,200 11,300 7.130 7,900 8,600 6,920 7,750 4,040 4,550 5,200 4,000 4,500 3,540 63/- H.S2 r If' ir&2* (2,300 (4,000 17,500 (2,500 (3,400 15,300 9,800 10,900 8,250 9,060 10,450 7,370 8,000 -7,000 98/- 20,000 20,800 24,800 20,000 21,200 24,000 (7,600 19,400 (1,800 13,100 (5,000 (1,700 12,500 (1,500 157/6 26,000 31,800 39,800 39,(00 4 (,600 47,200 39,900 43,800 21,100 23,800 29,600 22,600 24,600 20,500 225/- Above capacities are in pounds of water per hour based on continuous discharge to atmosphere 125 CRANE- THE "WELLDECK" STEAM TRAP Registered design No. 766460. Fig. H88 GUN METAL Fig. H89 CAST IRON The improved "Welldeck" Trap has the following advantages: Brass hot-pressed bolted-on covers for ", and sizes. High grade mall, iron bolted-on cover for I" size. Covers are easily and quickly removable. Rust-proofed, machine-moulded bodies of high grade cast-iron. Improved capsule construction giving large capacity, greater sensitivity and sharper action. Coarser thread on setting screw with less tendency to strip, or jam when hot. For Saturated Steam Pressures up to 125 lbs. per sq. in. PRICES AND CAPACITIES Sizes. Screwed Standard Gas Threads 3// 8 2\ 3// 4 1" Price Complete Cast Iron Gun Metal Female Ends Female Ends 19/6 19/6 21/9 24/6 27/6 27/6 37/53/- Spare Parts Condenser Valve 3/- 1/8 3/6 1/8 5/6 2/6 7/- 3/- Continuous Discharge. Galls, per hour at 212 F. 42 110 264 627 The capacities given above are for steady discharge after adjustment at 120 lbs. pressure. For intermittent discharge calculate 10 per cent, of these figures. PIPE STRAINERS CRANE Fig. HI2I CAST IRON Recommended on the inlet side of every Trap or Reducing Valve. Fig. HI 12 GUN METAL Sizes: Fig. HI2I ... Fig. HI 12 ... \>t 2 11/3 14/- 3 4 14/15/- 1" 18/22/- ir 22/6 39/9 \Y 27/9 40/9 See General Catalogue for Flanged Pipe Strainers. Y 47/6 57/- REDUCING VALVES "THE NEERFAIL " GUN METAL SPRING TYPE The Valve automatically closes in the event of the Boiler Pressure exceeding that to which it is set. NOTE.--This reducing valve can be supplied dead-weight as well as spring type. i rSizes: T1 # 2." 4 1" I \ff Fig. HI5I 113/6 Fig. HI52 133/6 123/6 144/6 139/6 158/- 157/6 189/6 197/6 237/6 If ordering Fig. HIS2 please specify if flanges are required B.S. Table D, F, or H, etc. 127 1 CRANE EXPANSION JOINTS GUN METAL SCREWED ENDS GUN METAL THROUGHOUT FOR STEAM WORKING PRESSURES UP TO 100 POUNDS Fig. H3II rSizes: F r IF IF 2" 2F 3" Price .. Traverse .. .. 9/6 r 11/6 17/6 20/6 25/6 35/- 47/- 63/- 2F 2F 2F 2V 2F 2F 3" End to End,Open 6|" 7r 7j" . 7" 7i" 8F 9F ior CAST IRON Fig. H3I2 SCREWED Sizes: Price...................................... Traverse .. .. .. End to End, Opened .. r 48/- CM 54/2F I2F 3" 66/2F I3F 3F 84/ 3" I4F 4" 90/3F I5F 5" 133/6 4" 18" 6" 157/6 5" 21" IRON BODY, FACED FLANGES GUN METAL WEARING PARTS WITH TIE RODS STEAM WORKING PRESSURES: UP TO 50 POUNDS TESTED TO 200 POUNDS HYDRAULIC Fig. H3I3 B.S. TABLE D FLANGES Sizes: Price .. .. Traverse .. F. to F., Opened IF 66/2j" 13" IF 71/2F 13" 2" 72/2F 13" 2F 78/ 13" 3" 102/ 3" i3r 3w 135/ 3" 14" 4" 135/ 3" 15" 5" 168/ 3" 16" 6" 180/ 3" 16" Fig. H3I3 is fitted with Brass Sleeve without Gun Metal, Neck Rings. Expansion Joints are not furnished packed unless so ordered, and then at a special price. If wanted packed, specify kind of packing required. For Dimensions of British Standard Flanges--see pages 210 and 211. 128 CRANE CAST IRON GLOBE VALVES GUN METAL WEARING PARTS FOR STEAM WORKING PRESSURES UP TO 125 POUNDS Fig. No. Sizes: 2" 2F 3" 3F 4" 5" 6" 8" F35I Price .. 58/6 75/- 104/- 127/- 158/6 225/- 312/6 600/- End to End 6F T 8" r 10" nr 13" I8F Fig. F35I SCREWED FigNo. Sizes: 2" 2f 3" ' 3F 4" 5" 6" 8" F352 Price .. .. 71/6 89/6 125/- 154/- 187/6 258/6 350/- 641/6 Face to Face .. 8" 8F 9F I0F nr 13" 14" I9|" Dia. of Flanges .. 6" 6F 7F 8" 8i" 10- i r 13*' F352. For larger sizes see General Catalogue. SWING CHECK VALVES IRON BODY WITH GUN METAL SEAT RING . BRITISH STANDARD TABLES D and E. FLANGES FOR STEAM WORKING PRESSURES UP TO 125 POUNDS FOR WATER WORKING PRESSURES UP TO 175 POUNDS Fig. F440 SCREWED Fig. F442 FLANGED Sizes: 2" 2^ 3' 3i" 4' S' 6" 8" F440. Price ... E442.................... Face to Face ... 56/6 56/6 10*' 62/ 62/ 12' 68/6 80/9 93/ 124/6 145/3 235/6 68/6 80/9 93/ 124/6 145/3 235/6 12" 12" -14" 16' 16' 20' Flanged Valves are supplied undrilled unless otherwise ordered. Drilling charge, 2d. per hole. 129 I A- CRANE STANDARD CAST IRON WEDGE GATE VALVES NON-RISING STEM IRON BODY WITH GUN METAL WEARING PARTS Size: V 2i" 3" 4" Price............... 36/- 39/- 45/- 59/6 w w wEnd to End ... 6" Centre toTop 9*" 10*' nr I4f" Fig. FSI SCREWED ENDS STEAM WORKING PRESSURE 100 lbs. WATER WORKING PRESSURE 175 lbs. TESTED TO 300 lbs. HYDRAULIC Fig. F52 SECTIONAL VIEW" Fig. FS2 FLANGED ENDS BRITISH STANDARD TABLES D and E FLANGES Size: 2" 21" 3" 31" 4" 5" 6" Price ... 36/- 39/- 45/- 55/- 59/6 82/- 94/6 Diam. of Flanges 6" ey 71" 8" 8*' 10" II" Face to Face ... 5T 6T 6r 7" 71" 7f" 8" Centre to Top ... o7_126_" 10*" nr I2f" I4f" 16*" 181" Flanged Valves are supplied undrilled unless otherwise ordered. Drilling charge, 2d. per hole. 130 . HEAVY CRANE CAST IRON WEDGE GATE VALVES IRON BODY WITH GUN METAL WEARING PARTS FOR WATER WORKING PRESSURES UP TO 225 POUNDS BRITISH STANDARD TABLE D and. E FLANGES Sizes: 2" O42l" 3" 3r 4" 5" 6" 8" Price Un stamped 46/6 52/6 64/- 76/- 90/- 123/- 142/- 226/- Dia. of Flanges 6" 6V w 8" 8*' 10" Face to Face ... 7" 7*' 8" sr 9" 10" Centre to Top nr 12j" ur 1 J 1 6 16*" I9|" II" 13*' ior II*' 2ir 26*" The fee for scamping by the Metropolitan Water Board is extra. See separate price list. For Prices of Valves with B.S. Table F, etc. Flanges and larger sizes-- see General Catalogue. Fig. F62 NON-RISING STEM FLANGED Fig. F65 M.W.B. OUTSIDE SCREW GATE VALVES GUN METAL WEARING PARTS FOR WATER WORKING PRESSURES UP TO 225 POUNDS. NON-SHOCK Fig. F89 Stamped "Heating only Tested by Met. W.B." Size: 2" 21" 3" 3* 4" 5" 6" 8" Price Un stamped 63/- 76/- 82/6 103/- 114/- 157/- 179/- 357/6 Face to Face 7" 71" 8" BV 9" 10" 10*' II* Dia. of Flanges 6" 61" 7* 8" 81" 10" II" 131" Fig. F8I Fig. F89 M.W.B. FLANGED B.S. TABLES D and E Centre to Top Open 15*" 16*" 19*" 21*" 24*" 29*" 32f" 41*' The Fee for Scamping by the Metropolitan Water Board is extra. See Separate Price List. Flanged Valves are supplied undrilled unless otherwise ordered. Drilling charge, 2d. per hole. r CRANE----------------------------------------------------------------------------- CAST IRON FLANGED FITTINGS BRITISH STANDARD TABLES D and E FLANGES TEST PRESSURE 200 POUNDS HYDRAULIC No. A5I FLANGED ELBOWS EQUAL AND REDUCING No. A53 FLANGED ELBOWS SIDE OUTLET No. A54 45 FLANGED ELBOW I No. A55 FLANGED ELBOWS WITH DUCKFOOT No. A56 FLANGED BENDS No. A57 FLANGED BENDS, 45 FLANGED SHORT SWEEP TWIN ELBOWS EQUAL AND REDUCING No. A6I FLANGED TWIN BENDS LONG SWEEP For Prices--see page 133. For Dimensions of British Standard Flanges--see pages 210 and 211. For General Dimensions--see page 138. See General Catalogue for Table F and Cast-steel Fittings. 132 CRANE CAST IRON FLANGED FITTINGS BRITISH STANDARD TABLES D and E FLANGES TEST PRESSURE 200 POUNDS HYDRAULIC FACED FLANGES Sizes A5I A53 A54 A55 A56 A57 A6I A59 F/ongeG Flangec Flangec Elbows Long Elbow 45 with 45 Sweep Flanged Flanged Elbows, Side Flangec Duck- Flanged Flanged Twin Twin Equal. Reducing Outlet Elbows foot Bends fiends Bends Elbows A59 Flanged Twin Elbows Reducing V 7/6 7/6 18/6 7/6 16/6 11/6 11/6 23/6 ii/91" 8/6 8/6 20/- 8/6 21/- 12/6 12/6 28/3 13/6 3" 9/6 9/6 24/- 9/6 22/6 14/6 14/6 33/3 16/3i" 11/6 -- 27/- 11/6 23/3 18/- 18/- 36/- 17/3 4" 13/3 13/3 30/- 13/3 24/- 19/3 19/3 37/3 19/9 5" 18/6 18/6 38/6 18/6 33/- 28/9 28/9 54/- 29/6" 22/6 22/6 52/- 22/6 36/- 36/- 36/- 63/- 37/9 7" 27/- 27/- 58/- 27/- 54/- 40/6 40/6 81/- 44/3 8" 34/- 34/- 70/- 34/- 60/- 50/9 50/9 97/3 56/9 2"x 2"x3" ... 16/-- 3"x3"x4" ... 19/9 3"x3"x6" ... 37/9 4"x4"x5" ... 29/5"x5"x7" ... 44/3 6"x6"x8" ... 56/9 7"x7"x8" ... 56/9 -- For Dimensions of BritisITStandard Flanges--seepages 210 and 211. For General Dimensions--see page 138. For Fittings under T and over 8" sizes, also for Fittings to Table "F," particulars--see General Catalogue. Flanged Fittings throughout are supplied undrilled unless ordered otherwise. Standard drilling charge is 2d per hole. CRANE CAST IRON FLANGED FITTINGS BRITISH STANDARD TABLES D and E FLANGES TEST PRESSURE 200 POUNDS HYDRAULIC No. A63 FLANGED TEES I SINGLE SWEEP FLANGED TEES EQUAL AND REDUCING No. A70 FLANGED LONG SWEEP TEES EQUAL AND REDUCING For Prices--see page 135. For Dimensions of British Standard Flanges--see pages 210 and 211. For General Dimensions--see page 138. See General Catalogue for Table F and Cast Steel Fittings. 134 CRANE CAST IRON FLANGED FITTINGS BRITISH STANDARD TABLES D and E FLANGES TEST PRESSURE 200 POUNDS HYDRAULIC Sizes 2" 2-j" 3" 31" 4" 5" 6" T 8" FACED FLANGES A63 Flanged Tees Equal and Reducing 10/- 12/- IS/- 17/3 18/9 27/6 33/- 42/- 52/6 A66 Flanged Tees Side Outlet 24/17/6 30/36/39/54/68/78/90/- A68 Flanged Single Sweep Tees II/- 13/6 16/- 17/3 19/9 29/- 34/6 44/3 56/9 A70 Flanged Long Single Sweep Tees 15/3 16/6 19/6 22/6 27/- 40/6 54/- 65/- 73/- For Dimensions of British Standard Flanges--see pages 210 and 211. For General Dimensions--see page 138. For Fittings under T size and over 8"--see General Catalogue. Flanged Fittings throughout are supplied undrilled unless otherwise ordered. Standard drilling charge is 2d. per hole. 135 CRANE CAST IRON FLANGED FITTINGS BRITISH STANDARD TABLES D and E FLANGES TEST PRESSURE 200 POUNDS HYDRAULIC No. A72 FLANGED CROSSES No. A72 REDUCING FLANGED CROSSES No. A76 FLANGED TAPER REDUCERS No. A74 FLANGED LATERAL " Y " BRANCHES No. A79 FLANGED CO-LATERAL " Y " BRANCHES For Prices--see page 137. For Dimensions of British Standard Flanges--see pages 210 and 211. For General Dimensions--see page 138. -------------------------------------------------------- ----------- CRANE CAST IRON FLANGED FITTINGS BRITISH STANDARD TABLE D and E FLANGES TEST PRESSURE 200 POUNDS HYDRAULIC FACED FLANGES Sizes A72 Flanged Equal Crosses 2" IS/- 2i" 18/- 3" 19/9 3i" 22/6 4" 24/9 5" 36/6" 48/- 7" 64/9 8" 72/- A72 Flanged Crosses Reducing 2" x ir... IS/2*' X Is" ... 18/21' x2" ... 18/3" xl" ... 19/9 3" X 2" ... 19/9 3" X21" ... 19/9 31' x2i" ... 22/6 4" X2" ... 24/9 4" X2i" ... 24/9 4" x3" ... 24/9 5" x4" ... 36/6" X3" ... 48/6" x4" ... 48/7" x5" ... 64/9 8" x4" ... 72/8" x6" ... 72/- A74 Lateral "7" Branches 13/6 IS/- 16/6 25/3 27/- 36/45/- S9/6 66/9 A79 Co-Lateral "7" Branches II/13/4 16/6 19/20/9 30/3 36/6 46/3 S7/9 NNo. A76 Flanged1 Taper Re< Length Sizes "G" PRICE 2" xli" 21"x|i" 2i" x 2" 3" xlf' 3" x2" 3" x2i" 31" x 2" 3i"x2i" 4" xli" 4" x2" 4" x2i" 4" x2i" 4" x3" 4" x3i" 4i"x2i" 4i"x4" 5" x2i" 5" x3" 5" x4" 6" x2i" 6" x3" 6" x4" 6" x4" 6" xS" 6" x5" 7" x2" 7" x3" 7" x4" 7" x5" 7" x6" 8" x4" 8" x5" 8" x6" 8" x7" 15/9 >21/9 / 28/9 1 For Dimensions of British Standard Flanges--see pages 210 and 211. For General Dimensions--see page 138. For Fittings under 2" and over 8" sizes--see General Catalogue. 137 CRANE CAST IRON FLANGED FITTINGS GENERAL DIMENSIONS No. A5I. Equal. Reducing. No. A54 No. A59. Equal. Reducing. No. A6I No. A63 No. A68 No. A72. Equal. Reducing. No. A79 Size: 2" 2F 3" A 5" Si" 6" C 3" 3" D 10" 10" 12" E 5" Si" 6" J 3" 3i" 4" M 8" 9i~ 10" N 2F 2r 3" 2rO 5" P Si" 2F 6" 3" 3r" 4" 5" 6" 7" 8" 6F 7" 8" 9" 10" U" 3r 4" 4F 5" Si" Si" 14" 14" 15" 16" 16" 18" 8" 8" 9" 10- II" II" 4" 4" 5" 6" 6" 7" nr 12" 3" 3" I3F I4r I6F I7F 3i" 3F 4" 4i" 6i~ 7" 8" 9" 10" II" 3r 3F 4" 4r 5" sr For ocher Dimensions--see General Catalogue 138 FLANGES r r rSizes: FFF r r r r r 1" r IF IF Diameter 3r 3}" 4" 4F 5F 6" Price 4" 4F 4F SF SF 6" 6F 4F 4F undrilled i/- l/3i 1/4 I/Si 2/2 2/4 I/s l/5i I/I0i 2/2 2/4 2/4 3/- 1/9 1/9 Sizes: if IF IF IF IF IF IF IF 2" 2" 2" 2" 2" 2" 2F Diameter 5" 5F 6" 5" SF 5F 6" F 6" 6F 7F 7F 8" 8F 6F undrilled 2/1 2/3 2/4 2/1 2/2 2/9 2/9 2/11 2/4 2/M 3/4 3/10 4/- 4/7 2/8 Sires: 2r 2F 2F 2F 2" 3" 3" 3" 3" 3" 3" 3F 3F 3i" 3F Diameter Price undrilled 7F 7F 8" 8i" 9" 7F 7F 8" 8F 9" 10" 8" 8F 9" 10" 3/4 3/10 4/- 4/7 S/2 3/3 3/10 4/- 4/7 S/2 5/10 4/- 4/1 5/2 5/10 4"Sizes: 4" 4" 4" 4" 5" 5" 5" 6" 6" 6" 7" 7" 8" 8" Diameter Price Undrilled 8" 9" 10" ir 12" 10" i 1" 12" ir 12" I3F 12" I3F I3F I4F 4/1 S/2 5/10 7/4 10/3 S/10 7/4 10/3 8/2 10/3 12/3 M/8 14/7 17/6 21/11 CAST IRON FLANGE UNIONS FOR STEAM WORKING PRESSURES UP TO 125 POUNDS FOR WATER WORKING PRESSURES UP TO 175 POUNDS Figure No. Sizes: r 2i" 3" 3' 4" 5" 6" 8" AI5I Price, Black ... 4/2 5/3 6/3 7/6 8/9 13/2 16/6 29/2 ,, Galvd. ... 8/4 10/6 12/6 IS/- 17/6 26/4 33/- 58/4 Diameter of Flanges H" Si" 6#" H" 7f' Qi/f I0|" 122" Number of Bolts 44445 5 68 See page 160 for malleable iron flanges 139 CRANE INDIRECT CYLINDERS FOR HOT WATER SUPPLY OPERATED BY A RADIATOR HEATING BOILER WATER TO WATER Can be fixed horizontally or vertically Fig. 935 galvanized steel Fig. 936 COPPER Fig. 935. Galvanized Steel Indirect Cylinders. Nos. 0, I, 02 and 2 with_Fixed Head, Nos. 3-8 with Bolted Head and India-rubber jointing ring, as illustrated Net Heat Test Working GAUGES No. Stor* ing pressure Pressure age Surface lbs. per ft. head Gails. sq, ft. sq. in. of water Body Ends PRICE s. d. Test Working Pressure Pressure lbs. per ft. head sq. in. of water GAUGES Body Ends PRICE s. d. 0 24 1 30 02 35 2 40 3 50 4 60 5 80 6 100 7 150 8 200 6* 40 10* 40 12 40 14 40 17* 76 20$ 76 27* 64 35 64 52 56 70 50 50 I4G I2G 4 7 0* 40 50 * 5 5 0* 50 I4G I2G 4 18 0* 40 50 6 3 0* 50 I4G I2G S 10 3* 40 50 6 18 0' 50 I4G I2G s 15 0* 40 50 * 7 9 0* 90 8 6 9 94 HO A H 14 0 90 9 12 6 94 110 A 13 3 0 75 * II 18 0 84 95 A 75 i 13 18 0 84 95 TV 15 12 0 18 12 0 65 18 18 0 76 90 24 5 0 60 23 18 0 70 80 A tV 30 0 0 * Extra for Bolted Head on application Sire of connections--24 and 30 gall., I"; 35 and 40 gall., I"; 50 and 60 gall., 1"; 80 and 100 gall., 2 ; 150 gall., 2";200 gall., 3" Fig. 936. Copper Indirect Cylinders, Inner Cylinder Corrugated, all with Fixed Head. Net Heat Test Working GAUGES No. Stor ing Pressure Pressure age Surface lbs. per ft. head Galls. sq. ft. sq. in. of water Body Ends 0 24 01 27* 1 30 02 35 2 40 3 50 4 60 5 80 6 100 7 150 8 200 6* 9 10* 12 14 I7 20 27 35 52 70 25 25 25 25 25 30 30 30 30 30 30 35 20 18 35 20 18 35 20 18 35 20 18 35 20 18 40 18 16 40 18 16 40 16 14 40 16 13 40 14 12 40 14 ` II PRICE s. d. 5 15 6 13 73 7 19 8 12 12 5 13 17 22 15 28 5 48 10 65 17 0 0 0 6 0 0 6 0 0 0 6 Test Working Pressure Pressure lbs. per ft. head sq. in. of water _ -------- -------- 50 70 50 70 50 70 50 70 50 70 50 70 GAUGES Body Ends __ -- -- ---- -- ---- ----- 16 14 16 14 14 (2 14 12 12 10 12 9 PRICE i s. d. -- ---- 14 12 16 10 26 IS 32 15 55 0 76 0 6 0 0 0 0 0 Size of Connections--24 to 30 gall., I", 35 and 40 gall., I*"; 50 and 60 gall., I*"; 80 and 100 gall., 2"; 150 gall., 2i"; 200 gall., 3" 140 CRANE COPPER AND GALVANIZED INDIRECT CYLINDERS GALVANIZED CANTILEVER BRACKETS For supporting Indirect Cylinders Fig. 937 Horizontal Fig. 938 Vertical State if required for Horizontal or Vertical fixing. Prices on application. DIMENSIONS IN INCHES A No. u. A cl <3 s 'J 0 30 30 01 34* --- 1 39 39 02 42* 42* 2 48 48 3 50 50 4 58 58 5 54 54 6 69 69 7 65* 65* 8 /6i 76* B L. i3 22 22 27 -- 31* 31* 32 32 38* 38* 39 39 45 45 41 4i 53 53 50 50 59 59 C 13 *2 >3 5* 5 5* -- 66 66 6* 6 75 75 7* 6 7* 6 96 97 D s 0> 18 18 18 18 18 18 18 18 18 20 20 20 20 24 24 24 24 30 30 32 32 E -g ij U 5* 5* 5* 66 66 6* 6* 75 75 7* 6 7* 6 96 97 F Q) d g U 25 25 29* -- 33 33 36 36 40* 40* 41 39 47 45 45 43* 60 58* 55* 54 66* 65* Size of Connections 6 <3 11 |-- 1I i* t* i* i* i* i* i* i* 22 22 2* 2* 33 PRIMARY CONNECTIONS SCREWED MALE, SECONDARY AND COLD WATER ARE FEMALE GALVANIZED FEED AND EXPANSION CISTERNS Fig. 939 FOR SMALL HEATING INSTALLATIONS COMPLETE WITH FLANGES FOR OUTLET AND OVERFLOW AND PLAIN HOLE CUT FOR BALL VALVE * Cap acity Gallons 10 15 20 25 30 DIMENSIONS Length ins. 18 24 20 24 24 Width ins. 12 12 15 17 18 Depth ins. 12 15 20 17 19 SIZE OF CONNECTIONS Gauges Ball Valve Outlet Overflow * * 1 18 1 18 * 1 16 * * 1 16 * * i 16 PRICE Without Cover PRICE With loose Cover (I8G1 18/3 21/8 25/7 27/- 29/- 20/6 24/8 28/6 31/4 33/7 * Total Nominal Capacity of Cistern. For larger Cisterns order Figs. 942/3. 141 i CRANE GALVANIZED HOT WATER CYLINDERS WELDED TOP AND BOTTOM. SIDES RIVETED OR WELDED Galvanized after manufacture and tested. WITHOUT HANDHOLE. Fig. No. 940. Go/fons Approx. 20 21 23 25 28 31 34 37 40 42 45 48 56 60 65 75 85 100 Dimensions 16 G. Diameter Height Inside Overoll Pressure = 10 ft. Head of Water Inches Inches / '5 X 30 \ \ 18 X 24 / 15 X 33 15 X 36 r 18 X 27 \ \ 15 X 39 J / 18 X 30 \ \ 15 X 42 / / 20 X 27 \ \ 18 X 33 J 18 X 36 r 18 X 39 \ \ 20 X 30 J 18 X 42 r 18 X 45 \ \ 20 X 36 J 18 X 48 20 X 42 20 X 48 20 X 51 22 X 48 24 X 48 24 X 54 24 X 64 s. d. i 15 i 16 i 17 i 19 0 3 8 1 i 19 9 204 228 245 263 283 2 10 | 2 12 9 2 16 0 -- -- -- -- -- 14 G. Tested to 15 lbs. Pressure -- 30 ft. Head of Water 12 G. Tested to 20 lbs. Pressure -- 40 ft. Head of Water i" Tested to 25 lbs. Pressure = 50 ft. Head of Water S. d. s. d. S. d. i 18 20 21 23 9 3 9 7 24 25 27 2 10 0 9 0 2 10 i 2 12 5 2 14 9 2 16 II 24 1 2 II 3 2 19 0 25 0 274 29 5 2 II 7 2 13 4 2 15 5 2 18 0 32 1 348 404 4 1_2 3 -- 2 12 9 2 15 1 2 17 7 30 1 323 340 377 3 12 3 3 14 II 4 12 5 547 5 18 II -- 317 335 357 3 7 II 3 10 3 3 13 | 3 17 7 4 2 II 4 6 II 557 5 19 5 6 18 1 779 Special Sizes. These are priced at next larger capacity. * Prices include up to 4-ly" Screwed Flanges or Bosses. See page 147 for extras. * In calculating the extra for Flanges or Bosses, the total price of such Flanges or Bosses shall be taken and the Price of 4-l" Flanges or Bosses deducted therefrom, provided the ultimate price is not lower than the list price. 142 CRANE GALVANIZED HOT WATER CYLINDERS RIVETED THROUGHOUT Galvanized after manufacture and tested before despatch. WITHOUT HANDHOLE. Fig. No. 941. Gallons Approx. Dimensions Diameter Height Inches Inches 16 G. Tested to 5 lbs. Pressure = 10 ft. Head of Water s. d. 14 G. Tested to 15 lbs. Pressure =* 30 ft. Head of Water s. d. 12 G. Tested to 20 lbs Pressure -- 40 ft. Head of Water s. d. A* Tested to 25 lbs. Pressure -- 50 ft. Head of Water s. d. 20 *|f is X 30 1!h l 18 X 24 J i 18 7 21 15 X 33 i 19 9 23 15 X 36 2 1 5 25 {r 1IS8 X 3297 }1 2 3 0 X 28 1r is l is X X 30 42 J1S- 239 31 !r 20 X 27 1 1 is X 33 J 245 34 18 X 36 2 7 1 37 if 18 x 39 1 V \_ 20 X 30 J 289 40 18 X 42 2 10 II 42 -<r is X 45 1 L 20 X 36 J 2 13 0 45 18 X 48 2 15 4 48 20 X 42 2 18 0 56 20 X 48 318 60 20 X 51 -- 65 22 X 48 -- 75 24 X 48 -- 85 24 X 54 -- 100 24 X 64 -- 228 24 1 260 279 287 297 2 12 1 2 14 5 2 16 8 2 18 II 310 339 383 3 II 1 487 517 -- -- 284 2 10 5 2 12 9 2 15 1 2 16 7 2 17 9 305 33 1 36 1 385 3 10 7 3 14 4 3 19 5 425 518 5 15 0 6 10 8 -- 2 15 4 2 17 9 303 327 3 4 II 379 398 3 12 3 3 15 0 3 17 7 40 45 4 II 4 15 5 16 6 II 7 II 82 7 1 3 9 1 4 9 5 Special Sizes. These are priced at next larger capacity. Prices include up to 4-l" Screwed Flanges or Bosses. See page 147 for extras. In calculating the extra for Flanges or Bosses, the total price of such Flanges or Bosses shall be taken and the price of 4-l" Flanges or Bosses deducted therefrom, provided the ultimate price is not lower than the list price. 143 1 CRANE.---------------------------------------------------------------------------------- - GALVANIZED OPEN TOP CISTERNS WITH INTERNAL ANGLE IRON AT TOP AND CORNER PLATES Nominal Capacities. Galvanized after manufacture, and tested before despatch. Fig. No. 942. CRANE GALVANIZED OPEN TOP CISTERNS WITH BENT-OVER TOPS AND CORNER PLATES Nominal Capacities. Galvanized after manufacture, and tested before despatch. Fig. No. 943. See page 147 for extras. Sizes marked x sent unless otherwise ordered. 145 K CRANE GALVANIZED HOT WATER TANKS WITH SET-PINNED HANDHOLE COVER AND I.R. RINGS Galvanized after manufacture and tested before despatch. Fig. No. 944. Gallons Approx. D mensions (Assumir g Handho fe Side is regar led as the Top). Length Width Depth Ft. In. Ft. In. Ft. In. 16 G. U G. 12 G. i" Tested to a Tested to a Tested to a Tested to a Pressure of 1 lb. Pressure of 3 lbs. Pressure of 7$ lbs. Pressure of 10 lbs. per sq. inch. persq. inch. per sq. inch. per sq. inch. For A Working For a Working For a Working For a Working Head of 1 feet Head of feet. Head of 10 feet Head of 15 feet s. d. s. d. s. d. s. d. f x2 0 i 4 i 31 20 6 12 i6 i io6 Jr 203 0 20 4f 1 7 1 7 i 71 25 \ x2 0 1 5 i 2 3 II l2 0 20 oj i x2 0 1 6 i 7 30 18 20 18 20 i8 i3 278 20 1 3 20 nrx2 3 1 8 1 40 l i 10 1 10 1 10/ 50 {f x22 5 0 1 10 20 1 1o01) 2 _ -- 2 3 11 278 2 11 7 317 3 11 5 278 2 12 9 2 17 9 390 404 2 12 9 2 17 9 329 3 16 8 49 1 f x2 6 1 II 2 01 60 l 2 2 2 2 2 2 / 70 1 3 0 2 0 1 ") 1x2 3 2 3 2 3 J n80 0 2 2 2 1x2 4 2 4 2 4/ 3)fx8 2 2 3 2 100 l 2 6 2 6 2 6/ -- _ Tested to a Tested to a Pressure of 5 lbs. Pressure of7\ lbs. per sq. inch. per sq. inch. For a Working For a Working Head of 7? feet Head of 10 feet - 4 19 3 555 5 12 II 657 _ _ 757 845 Special Sizes. These are priced at next larger capacity. If without Rubber Ring, lid. less. Extra for LARGER HANDHOLES ............... 14" 8/7 18" 14/2 See page 147 for extras. Sizes marked x sent unless otherwise ordered. 146 i* *> EXTRAS CRANE TO HOT WATER CYLINDERS TANKS AND OPEN TOP CISTERNS 1V T r 1/8 2h 2F 3" 8/4 14/3 SCREWED FLANGES OR BOSSES. r IF 2/4 2/11 3F 4" 16/9 19/3 IF 3/4 5" 30/1 2" 4/8 6" 45/1 I1 1[ JI1 Extra per Flange or Boss. PLAIN HOLES, cut in, 5d. each Hole extra. EXTRAS TO OPEN TOP CISTERNS LOOSE COVERS WITH HANDLE. 22 W.G. 1/3 20 W.G. I/S 18 W.G. 1/8 16 W.G. 2/1 14 W.G. 2/7 per sq. ft. H PARTITIONS ... 16 W.G. 3/3 14 W.G. 3/7 12 W.G. 4/- F 4/S per square foot of Partition fitted extra EXTRAS TO HOT WATER CYLINDERS HANDHOLE, with set-pinned lid and rubber ring (in the case of Ova! Handholes the mean diameter to be taken). Up to and including 8 ins. 12/8 Up to and including 10 ins. 16/4 Up to and including 12 ins. 18/11 Up to and including 14 ins. 21/4 Up to and including 18 ins. 28/9 BRIDGED* LIDS ............... Single with Cast Bridge, up to 8 ins. mean diam. I (Mean diameter of Hole) ,, ,, Wrought ,, ,, 8 ins. ,, ,, .. ,, ,, ,, ,, 10 ins. ,, ,, Double ,, ,, ,, ,, 12 ins. ,, ,, 25/1 extra. 50/1 56/7 94/2 THICKER BOTTOMS--15 ins. diameter 18 ins. ,, 20 ins. ,, 22 ins. ,, 24 ins. ,, With both ends CONVEX, 10/- extra. 16 and 14 W.G. with Bottom. 3/9 extra 4/5 ,, 5/- , 5/8 ,, 6/11 ,, 12 W.G. and V with &" Bottom. ,,ll/S extra 12/8 M/S ,, 14/4 ,, 17/7 ,, A. C. D. ORDERS FOR CYLINDERS CANNOT BE EXECUTED UNLESS POSITION AND SIZES OF FLANGES ARE SPECIFIED (SEND SKETCH WITH ORDER WITH SIZES MARKED THEREON) SIZE OF FLANGES IN FREQUENT USE 20 to 40 gallons .. 40 to 60 gallons .. 60 to 75 gallons .. 80 to 100 gallons .. PRIMARY F & R Ins. li li li 2 ............. ............. .............. ............. SECONDARY Ins. ... 1 ... ... 1* ... ... li ... ... 1* ... COLD FEED Ins. ............... 1 ............... 1 ............... li ............... li 147 1 CRANE WROUGHT TUBES AND TUBULARS No. C4 No. C5 No. C23 PRICES No. C2 and C3 Figure No. Nominal Internal Diameter r&r r V r r i r 1*" 2" 2*" 3" 3*" 4" 5" 6" Cl C2 C3 C4 C5 C23 C6 C7,C8, C9 TUBES. Tubes-- 2 ft. long & over, per ft. Pieces-- 12" to 23" long, each 4" to 1 \\" long ,, Long Screws-- 12" to 23" long ,, 3" to 11" long ,, Barrel Nipples............ Bends ............... ,, Springs, not Socketed ,, -14 -Hi -ISi -m -m I/I -/I0 -/n I/I -/7 -18 -19 1/5 i/ii 2/8 -/II 1/3 1/8 1/4* 1/10 2/10 3/3 41- 4/5 6/- 7/6 3/4 4/9 81- 10/6 13/6 15/6 24/4 32/6 2/2 3/- 5/3 6/9 9/3 10/9 18/- 25/3 -/'I 1/- 1/3 1/7 2/2 2/10 -18 -/5 -19 -/I0 I/I 1/5 -15 -*/6 ~/7 -19 i/ii i /- -18 -/ -/ii 1/2 1/7* 2/7* 3/9 2/6 1/4 3/2 5/3 3/6 1/9 5/2 91- 12/- 15/6 17/- 26/6 35/6 6/6 8/6 11/6 13/- 20/- 28/ 3/- 4/- 6/- 7/- 12/6 20/12/- 18/- 25/- 32/6 105/- ISO/- -n-IS -16 -19 1/1* I/II* 2/3* 3/11 9/6 14/6 20/- 26/6 93/- 132/- EXTRAS AND ALLOWANCES SUBJECT TO CHANGE WITHOUT NOTICE REVISED APRIL 1st, 1937. Screwed and Socketed Random Length Tubes (sizes in. to - in.--8 feet and up, and sizes in. to 6 in. --15 feet and up) at our option are charged at List Price, less current discount. ALLOWANCES. Random length tubes (sizes in. to $ in.--8 feet and up, and sizes in. to 6 in.--15 feet and up)-- (o) Screwed, without sockets, less 2 % on the net. (b) Plain ends, without sockets, less 3$ % on the net. EXTRAS. Random lengths under 15 feet are charged as follows:-- 2 ft. to 4 ft. to 6 ft. to under 4 ft. under 6 ft. under 8 ft. Screwed and Socketed .......................... 15% 7\ % 3J % Screwed without Sockets .. .. .. 7 % 3j % 2* % Plain Ends without Sockets.......................... 3J % l% U% Any restriction within the above ranges may be subject to a further extra. 8 ft. to under 15 ft. 2 % less gross. % ,, ,, i% ,, ,, N.B.--In i in., ? in. and $ in. sizes the extras indicated above for lengths 8 feet--15 feet do not apply. EXACT LENGTHS.--For Tubes in exact lengths, irrespective of length, an extra of 2 % less gross discount will be charged in addition to the extras for short lengths and to any other extras or allowances which may be applicable. Pieces, Longscrews and Barrel Nipples in exact lengths are charged at List Prices with an extra of 5 % less gross discount. Tubes and Fittings of intermediate diameters are charged at the List Price of the next larger size, and are subject to a special discount. Carriage on orders not amounting to 10 net value will be to buyer's account. 148 WROUGHT FITTINGS FOR STEAM. WATER AND GAS CRANE iMiiMIMliliiUUi No. CIO No. CI2 No. CI3 No. CI4 No. CI8 No. CI9 No. C20 No. C2I No. C22 PRICES Fig. Nominal Internal No. Diameter r V 34 " r \i" I r r 2i" 3" 3r 4" 5" 6" CIO CII CI2 CI3 CI4 CIS CI6 CI7 CI8 CI9 C20 C2I C22 FITTINGS. Each Socket Unions ... H- 116 31 41- 516 6/9 SI- 10/- 17/6 22/6 27/6 35/- 66/- 105/- Pipe Unions............... V- H6 31- 41- 5/6 6/9 SI- 10/- 17/6 22/6 27/6 35/- 66/- 105/- Elbows, Square - ... -/I0 -/II I/I 1/3 1/6 2/2 111 4/3 9/6 14/- HI- 28/- 95/- 150/- Do. Round ............... -/II 1/- 1/2 1IS 1/8 2/4 2/10 4/8 10/6 16/- 24/- 30/- 95/- ISO/- Tees........................... 1/- I/I 1/3 1/7 1/10 2/6 3/1 5/1 11/6 18/- 26/- 32/- 98/- 155/- Crosses ............... 2/2 2/4 2/9 3/3 4/1 3/6 6/7 10/6 22/- 40/- 56/- 66/8 220/- 350/- Sockets, Plain ... -13 -13 -/4 -is -16 -/8 -im 1/3 2/6 3/6 5/- /- 12/- 18/- Do. Diminished ... -14 -is -16 -11 -19 1/- 1/4 H- SI- 7/- 91- ii/- 35/- 55/- Flanges ... ... -19 -/I0 u- HI 1/4 1/9 n- 2/9 Si- 8/6 10/- 11/6 18/- HI- Caps........................... Plugs........................... -I3i -Hi -IS -16 -IB 1/- 1/3 n- 4/4 61- 9/9 10/6 30/- 45/-13 -13 -14 -IS -16 -IB -/I0 1/3 2/6 4/9 7/- 10/- 30/- 48/- Backnuts ............... -11 -n -13 -/3i -is -16 -is I/I 2/3 3/6 4/6 5/6 18/- 26/- Nipples ... ... -11 -11 -13 -13i -14 -16 -IS 1/- 2/3 3/6 4/6 5/6 18/- 26/- EXTRAS AND ALLOWANCES SUBJECT TO CHANGE WITHOUT NOTICE FITTINGS PAINTED RED will be charged ac sceam discounts. FITTINGS PAINTED BLUE will be charged ac water discounts. FITTINGS coated inside and outside, or outside only, with bituminous or other solution are charged 2% less gross discount. FLANGES of larger diameters than the standard for the screwing size ordered will be charged at the gross price of the standard Flange of the diameter required, and, in addition, Flanges varying from the standards in diameter will be charged an extra 2-*% gross for every inch or part of an inch either over or under the standard diameter of British Standard Tables A to E. , CRANE British Standard 100 lbs. Air Tested Under Water * MALLEABLE IRON FITTINGS PLAIN No. 101 ELBOWS, EQUAL AND REDUCING No. 102 SQUARE ELBOWS No. 103 ELBOWS, M. & F. No. 105 ELBOWS, 45 No. 110 SIDE OUTLET ELBOWS No. Ill FEMALE STRAPPED DROP ELBOWS No. 81" 4i// 38 " 101 -m -/s* -/6* 102 -/* 103 -in -m -in 105 -m -m -/* no -m -/H* III -- -m i/i* 112 1/2* 11> 2 -/* -m -m 1/2* 1/5* No. 112 MALE AND FEMALE STRAPPED DROP ELBOWS 43" 1" 1*" 1/- 1/I/I* 1/19 2/21 1/5* 1/5* 1/7* 1/5* 2/6 2/10* 2/2* 2/2* -- 2/21 3/9* 4 1* No. 101 3/ 102 3/ 105 3/ NO 5/21 V 41 41 41 6/9* 21' 7/6 7/6 12/9* 3" 11/6 11/6 19/9* 3*" 4" 5" 6" 16/ 21/ 53/- 79/16/- 21/- For Dimensions--see General Catalogue. * Fittings 2j[" size and over tested 300 lbs. hydraulic. 150 British Standard ^ CRA N E MALLEABLE IRON FITTINGS No. 131 No. 126 PARALLEL THREAD SOCKETS CROSSES, EQUAL AND REDUCING No. 133 TAPERTHREAD SOCKETS \No. V 4 83'/ 2 No. 132 SOCKETS, REDUCING 3// 4 1" 115 -IH -m -m -m I/ll 1/7! 121 i/- l/2-j l/5| 2/1! 2/IO| 122 -- i/ii l/4f 1/9! 2/8^ 3/7* -m -m126 -/ll| l/lf l/7| 2/2! -m -m -m -m131 -6 -/8 -m132 -/4 -/5| -/7i -/I0 -m -m -m -m133 -16 -/8 -is134 -/ io* l/0i 1/7! 2/4| No. 134 STRAPPED SOCKETS ir 2/4# 4/3! 4/2/IO| I/O! 1/3 I/O! 3/3! ir 3/3! 6/-- 4/2# 1/5! 1/8! 1/5! No. 2" 017/ 3" 3#' 4" 5" 6" -- 115 4/6 8/6 13/- 121 8/1! 15/3! 23/4| 126 5/9! 10/ 15/ 131 2/1! 3/6 5/7! 132 2/6! 4/1! 6/6! 133 2 1! For Dimensions--see General Catalogue. i i im 18/ 20/ 7/7! 8/9 24/ 27/6 9/7! io/io! 60/ 70/1 16/9! 20/8! 88/ ns/1 24/31/10# i * Fittings 2" size and over tested 300 lbs. hydraulic. r CRANE British Standard 100 lbs. Air Tested under Water * TESTED MALLEABLE IRON FITTINGS 100 POUNDS AIR TESTED UNDER WATER PLAIN No. 136 CAPS No. 140 HEXAGON BUSHES No. 137 CAPS SQUARE HEAD No. 141 FLUSH BUSHES No. 138 EXTENSION PIECES No. (42 ECCENTRIC BUSHES No. 144 HEXAGON NIPPLES EQUAL No. 145 REDUCING No. r r r r A4 " r If" If" 2" 2*" 3" 4" 5" 6" 136 -m -/2f -ft -/4f -I6i -in 137 -- -- -- -ISi -/8| -mi 138 -- -- -16 -ISi 1/- 1/3* 140 -- -m -fti -16 -18 -/I Of 141 -- -- -ISi -m -in l/li 142 -- -- -- i/- ipi 1/8* 144 -ISi -ISi -16 -m -in 1/145 -- -ISi -I6i -Pi -im l/u l/lf 1/5* l/7f 1/4* 1/7* 2/If i/n 1/9* I/7f 2/0* 3/6* 5/3* 8/0* 9/9* -- -- 2/If 2/8* -- -- -- -- -- - 2/2* 3/- 1/9* 2/8* 4/6 7/- 9/6 12/- 22/- 34/- 2/3/2/2* 3/- 5/4/- /2* 3/2* 5/4* 7/8* 10/8/7* -- 14/IO/7f ----18/6 -- 15/- 30/- 47/- 2/4* 3/6 5/9* 9/6 12/- 16/6 -- -- For Dimensions--see General Catalogue. * Fittings 2*" size and over tested 300 lbs. hydraulic. British Standard ^ I""'1 CRANE MALLEABLE IRON FITTINGS BANDED FOR STEAM WORKING PRESSURES UP TO ISO POUNDS FOR WATER WORKING PRESSURES UP TO 200 POUNDS No. 146 BEADED PLUGS SOLID . No. 147 (PLUGS HOLLOW) SOLID No. 148 No. 149 PLUGS (COUNTERSUNK) No. 150 BACKNUTS No. V \ 4 83" 21 // 3 4 i" ir 1*' 146 _ _ _ -in -in -/8* i/i* 1/7* 147 -m -m -/3 -in -16 -18 i/- 1/4* 149 -16 -in -m V- 1/6 2/- 150 -m -m -/3 -m -in ~/Sf -m -/ io* 151 -in -in -in -m 1/2* 1/8* 2/7* 3/6 152 -in -in -m -im 1/3* I/I0f 2/9* 3/9* 155 -in -in -in -m 1/2* 1/8* 2/7* 3/6 No. 2" 2*" 3" 3*" 4" 5" 6" 146 2/1* . - . _ . ____ .. __ 147 I/I0f 3/3* SI- 7/- 9/- 21/7* 30/7* 149 3/- s- 91- -- -- 150 >/5* 2/1* 3/4* 4/7* 6/- 12/- 18/- 151 si- 91- 14/- 18/- 24/- 63/- 94/- 152 5/6 10/- 16/- 21/- - 27/6 72/- 108/- 155 si- 9h 14/- 18/- 24/- 63/- 94/- Solid Plugs (No. 148) are charged ac Lise Prices of No. 147 plus usual extras. For Dimensions--see General Catalogue. * Fittings 2" size and over tested 300 lbs. hydraulic. -- . -- -- -- -- -- -- CRANE British Standard V Under Water * MALLEABLE IRON FITTINGS BANDED FOR STEAM WORKING PRESSURES UP TO ISO POUNDS FOR WATER WORKING PRESSURES UP TO 200 POUNDS 1 t No. 161 | EQUAL TEES, AND REDUCING No. 163 TEES, MALE AND FEMALE No. 167 TONGUE TEES, EQUAL AND REDUCING iNo. 8\ i 4 83" sj 3" 4 i" r '*" 161 163 -m -m -m m i'/m- \1m/4* 2/2/6 m 41m 4/9* 167 -- 1/6 1/9* 2/6 3/6. S/6 . 171 -- i/- 1/22 m 2/- m m 5/2* 175 -- -- -- -- 2/6 3/6 6/6 176 -- -m -Pi -in -m 1/3* 1/9* 177 178 -- -- -m -m -m -m --Pmi -in -m -i m 1/3* -/ii* 1/4* 1/9* 2/- For Dimensions--see General Catalogue. * Fittings 2\* size and over tested 300 lbs. hydraulic. 154 ki British Standard ^ CRANE MALLEABLE IRON FITTINGS BANDED FOR STEAM WORKING PRESSURES UP TO 150 POUNDS FOR WATER WORKING PRESSURES UP TO 200 POUNDS No. 179 REDUCING SOCKETS No. 180 ECCENTRIC SOCKETS No. 181 LONG M. & F. REDUCING SOCKETS No. 1" 8 1" 4 2." 8 i// 2 1" 4 1" ir 1*' 179 -- -m -m -/6f -19 /- 1/6 2/- 180 -- '/- l/4f 1/9* 2/4f 181 ---- -- '-- m I/4J 1/9* 3/- 4/- 185 -/3 -/3 -m -m -m -/** 1/2* 1/9* 187 1/- 1/- 1/2* 1/6 2/1* 3/- 4/2* 6/- 188 l/4f 2/2* 2/IO| m 6/- No. V 2*" 3" 3*" A" 5" 6" -- 179 3/- 4/9* 7/8* 10/4* 13/- 24/- 37/- ____ 180 3/2* 5/2* 8/6 -- 16- -- -- 181 5/9* 9/6 15/3 19/6 26/- -- -- -- 185 2/3* 4/- 6/- 91- 11/- -- -- -- 187 8/6 14/- 21/- 27/- 35/- -- -- -- 188 8/- 15/- 24/- 40/- -- -- -- For Dimensions--see General Catalogue. * Fittings 2*" size and over tested 300 lbs. hydraulic. 155 CRANE British Standard $ Under Water * d LONG SWEEP MALLEABLE IRON FITTINGS BANDED FOR STEAM WORKING PRESSURES UP TO 150 POUNDS FOR WATER WORKING PRESSURES UP TO 200 POUNDS No. 193 FEMALE BENDS No. 41 ff s3" 2 3// 4 191 -m -m 1/- 1/4* 192 -m -im 1/1* 1/6 193 -in 1/21 1/81 194 -16 -m -in 1/1* 195 -m -m -im 1/2* 196 -in -in /- 1/4* 1" 2/21 2/3* 2/6 i in i in 2/- No. 196 FEMALE SPRINGS 1*" 3/3* 3/6 3/10* 2/7* 2/9* 3/2* 1*' 4/9* 5/5/6 3/91 4/4/6 No. 2" 191 7/192 7/6 193 83* 194 56 195 6196 7/- 2*" 13/14/15/4* 10/6 H/2* 13/- 3" 19/21/23/15/2* 16/9* 18/4* 31" 28/30/33/22/6 24/27/- U" 38/42/46/30/33/7* 37/- 5" 80/87/92/69/76/81/- For Dimensions--see General Catalogue. Fittings 2y" size and over tested 300 lbs. hydraulic. 6" 120/130/140/110/120/130/- British Standard ^ CRANE LONG SWEEP MALLEABLE IRON FITTINGS BANDED FOR STEAM WORKING PRESSURES UP TO 150 POUNDS FOR WATER WORKING PRESSURES UP TO 200 POUNDS No. 197 TWIN ELBOWS, EQUAL AND REDUCING No. 199 PITCHER TEES, EQUAL AND REDUCING No. 201 PITCHER CROSSES, EQUAL AND REDUCING No. X" 4 3" 'S X2 " 3" A 1" 197 1/3* im 1/9* 2/10* 4/3* 199 I/I* 1/2* 1/6 2/4* 3/7* 201 -- - -- -- 4/- 5/7* 1*" 61- 5/7/2* 1*' 8/6 7/10/6 No. 2" o^2// 3" 3*" 4" 5" 6" 197 12/- 23/- 38/- 50/- 199 10/- 19/- 32/- 42/- 201 14/6 24/- 38/- 50/ - 60/55/65/- 250/170/- -- 320/270/- -- For Dimensions--see General Catalogue. * Fittings 2i" size and over tested 300 lbs. hydraulic. 157 J CRANE British Standard ^ Kr%wJ""`l MALLEABLE IRON FITTINGS BANDED FOR STEAM WORKING PRESSURES UP TO ISO POUNDS FOR WATER WORKING PRESSURES UP TO 200 POUNDS No. 21! CLOSE RETURN BENDS (PLAIN PATTERN) No. 21" 3" * 1" 1*" 211 { *"x 1" 1/- *'xl*' rxi*' 1/7* 2/4* 14'xlf' 3/4* 212 { i'x ir 1/3* rxir l/IOJ l"xlf" 2/9* 1*"x 2*" 4/- 213 j i*x W *"x2" 1l 1/4* 2/1* 214 \ -- s'xA" [m 215 j **xl*' rxr i 2/2* 2/10* i 216 { *'xl*' 2/1* rx2" 3/2* 1" x 2*" 3/- I"x4" 5/ 1" X 6" 8/ 1" x 2*" 4/1* I"x4" 6/I"x2-*" 4/6 I*"x3" 4/4* I*"x6" 10/- I*"x3" 5/8* I*"x3" 6/6 |1 J2." 2" 2-L" 3" 4" I*"x2*" 2" x 2*" 4/8* 6/8* _ _-- I*"x2*" 2" x 3" 5/6 9/- -- 2"x4" ---- I*"x3*" 6/- 9/2" x 5" 2*" x 4*" 3" x 5" 4" x 6" 15/3* 22/8* 47/6 12/6 I*"x6" 2" x 6" 3" x 8" 12/- 14/- 33/7* _ I*'x3*' 2"x4" 7/8* 14/6 1i"x 3*" 2"x4" 9/- 15/- -- ---- For Dimensions--see General Catalogue. * Fittings 21" size and over tested 300 lbs. hydraulic. 158 CRANE TESTED MALLEABLE IRON FITTINGS No. 229 PIPE SADDLE ONE BOLT No. 230 PIPE SADDLE TWO BOLT No. F r r li" 221 2/2* r 3/- x if 1"4x/2*1*" l*"~x 2" 222 2/7* 3/< 51- No. Size.of Main Tapped 229 for Branch ... Price ............... ir f-f 4/2 2" 2" 2*" *'-r i*"-ir r-ir 4/2 4/ S/3 3" r-r s/3 3" 1 *"-2" 6/3 4" f-if 7/3 4" 2" 8/4 No. Size of Main Tapped 4" 5" 229 for Branch ... 2r-3" ir-i*" Price ............... 16/8 7/6 5" 2" 91- 5" 2*"-3" 16/8 6" r-ir 9/4 6" 6" 2" 2^-3" 10/5 20/10 No. Size of Main Tapped 230 for Branch ... Price........................... IF 8/4 2" F-i F 8/4 2* F-IF 10/5 3" F-2" 10/5 4" r-2" 12/6 5' l'-3" 23/- 6" r-2" 23/- No. Size of Main Tapped 230 for Branch ... Price........................... 6" 2**-4" 48/- 7" r-4" 54/- 8" r-4" 34/- 9" IF-4" 71/- 10" 2"-5" 83/6 10" 6" 105/- 12" 2"-6" 117/- 159 CRANE TESTED MALLEABLE IRON FITTINGS No. 233 ROUND FLANGES B.S. TABLE D. DIAMETERS No. 234 OVAL FLANGES No. 236 TWO-BOLT UNIONS No. 237 THREE-BOLT UNIONS No. 238 THREE-BOLT UNIONS, WITH GROUND-IN BALL AND SOCKET JOINT No. r r r 1" 4 r 1}" i r 2" 2}" 3" 3}" 4" 5" 6" -tw Os r? 233 i/- i Pi 1/4} 2/- 2/2} 3/6 4/6 7/- /- 10/6 12/6 18/- 24/- -in234 -Pi 1/1} 1/8} 2/2} 31- 3/6 4/1} 5/8} 8/- 10/- 12/- -- -- 236 2/3 2/4 219 3It SI- V- 7/10 M/- -- -- -- -- - - 237 -- -- 3/2} 4/1} 5/6 7/- 8/- 11/4} 15/- 21/6 26/- 30/- -- - 238 -- -- 3/3 4/1 5/6 7/- 8/- H/5 15/- 21/6 -- -- -- -- W CRANE UNIONS AND UNION FITTINGS MALLEABLE IRON FLAT-FACED SEATING GASKETS EXTRA No. 246 UNION ELBOWS, FEMALE No. 247 UN-ON ELBOWS, MALE AND FEMALE No; 241 STANDARD UNIONS. GASKETS EXTRA No. 242 STANDARD UNIONS, M. & F., GASKETS EXTRA No. 249 UNION TEES, FEMALE - No. 25<K UNION TEES, MALE AND FEMALE No. i" r i" r r r l+" l+" 2" 2+" 3" 3+' 4* 241 242 246 247 249 1/7+ __--. 1/71 i1//8io5 i v1/10+ 2/- 2/3+ 2/1 + 2/4+ 2/2* 2/4+ 2/9+ 2/6 3/2/8+ 33//6- 3/3+ 3/10+ 3/7+ 3/7+ 4/2+ 4/3+ 84//8-+ 4/9+ 5/7+ 6/1 + 6/9+ 6/4+ 6/4+ 7/6 8/2+ 9/3+ 8/9+ 11910///6-7+ 13/12/2+ 16/- 25/- 1------8/7+ 30------/2+ 3------8/- -- 5------0/- -- 250 2/2+ 2/6 3/1 + 4/1+ 5/3+ 7/2+ 9/10+ 13/8+ " Prices of Gaskets for above are given on page 164. 161 L CRANE UNIONS AND UNION FITTINGS MALLEABLE IRON ALL IRON. GROUND SEAT No. 261 UNION ELBOWS, FEMALE No. 256 FEMALE UNIONS No. 262 UNION ELBOWS, - M. & F. No. 264 UNION TEES, FEMALE No. 257 MALE AND FEMALE No. 265 UNION TEES, M. & F. No. 4t" r V r r 1?" 1?" 2" 2?" 3" 3?" 4" 256 2/1? 2/4? 2/10? 3/7? 4/4? 5/9? 7/9? II/- 19/6 31/6 46/- 60/- 257 2/6 2/9? 3/4? 4/2? 5/2? 6/9? /2? 13/- 23/- 37/- -- 259 -- -- 3/3? 4/4? 5/9? 8/1? ---- 260 -- -- 3/9? 5/- 6/6 9/- _ ___ -- -- -- -- 261 2/1? 2/7? 3/- 4/- 5/2? 7/4? 10/- 14/- __ __ -- -- 262 2m 2/10? 3/7? 4/8? 61- 8/2? 11/2? 15/7? -- -- -- -- 264 -- -- 3/3? 4/4? 5/8? 7/8? 10/7? 14/8? -- -- -- -- 265 3/9? V- 6/4? 8/8? 12/- 16/3? -- -- -- CRANE UNIONS AND UNION FITTINGS MALLEABLE IRON RAILROAD PATTERN BRASS TO IRON SEATS No. 271 RAILROAD UNIONS, FEMALE No. 272 RAILROAD UNIONS MALE AND FEMALE No. 279 RAILROAD UNION TEES, FEMALE No. 280 RAILROAD UNION TEES,. MALE AND FEMALE No. rF FF 1" IF IF r 2F 3" 3F 4" 271 1/3 1/8 2/1 2/6 3/4 5/- 6/8 8/4 (3/4 2Of- 33/4 41/8 272 1/7 2/1 2/7 3/2 4/2 6/3 8/4 10/5 16/8 25/- -- -- 276 I/ll 216 3/2 3/9 5/- 7/6 10/- 12/6 -- ---- 277 I/ll 2/4 3/2 3/9 51- 7/6 10/- 12/6 -- -- -- -- 279 2/1 219 3/S 4/2 5/6 8/3 II/- 13/9 -- -- -- -- 280 2/1 2/9 3/S 4/2 5/6 8/3 II/- 13/9 163 CRANE MALLEABLE IRON UNIONS NAVY PATTERN FOR STEAM WORKING PRESSURES UP TO 250 LBS. TWO BRONZE SEATS TWO BRONZE SEATS No. 289 Sizes: \" 4 3" Q V 3H 4 I" 1*' 2" 2*" 3" Black ... 1/3 1/8 2/1 2/6 3/4 5/- 6/8 8/4 13/4 20/- Galv. ... I/ll 2/6 3/2 3/9 5/- 7/6 10/- 12/6 20/- 30/- GASKETS FOR FLAT SEAT UNIONS AND UNION FITTINGS No. Sizes: 81 n J." 4 21// 3// 4 1" ir 298 Lead ... 299 Cranite... 300 Rubber... -/2 -/2 -VI* -/2 -/2 -/I* -m -m -/2 -/3 -/3 -/2i -/3* -/3y -/3 -/4i -/3f -/3i -/s -m No. Sizes: ir 2" 2*' 3" 3j" 298 Lead ... 299 Cranite... 300 Rubber... -16 -m -m -19 -m -IH 1/2 1/-m 1/5 l/3i -/* 1/10 1/7* I/I* 4" 2/2 2/1/5* -- -- -- -- 164 CAST IRON SCREWED FITTINGS FOR STEAM WORKING PRESSURES UP TO 125 POUNDS FOR WATER WORKING PRESSURES UP TO I7S POUNDS BANDED No. Al ELBOWS, R.H. No. A3 ELBOWS R. & L No. A6 TEES EQUAL No. All CROSSES No. AI2 REDUCING CROSSES No. A30 DOUBLE BRANCH ELBOWS No. A32 PITCHER TEES. EQUAL No. A35 RETURN BEND (MEDIUM) For Complete Range and Prices of Cast Iron Screwed Fittings--see General Catalogue, CRANE PIPE BRACKETS SCHOOL BOARD PATTERN SHORT SHANK SCREW ON Fig. 502 Fig. 501 FigNo. Sizes: 1" 4 3M 8 5i,f 31> 4 1" i r i r 2" 2k" 3" 3*" 4" -m -m -in -in501 Black Japanned -/3 -/3f -14k II- 1/4 1/9 2/4 2/8 501 Galvanized -m -m -m -14 -in -m -in 1/2 1/7 2/1 2/7 3/- 502 Black - -m -m -inJapanned -m -IH -14k -is 11- 1/6 I/ll 2/6 3/- -in -in -m -in502 Galvanized -/3 -14 -I4i 1/2 1/9 2/3 2/10 3/6 LONG SHANK Fig. 503 FigNo. Sizes: 21" 3// 4 i" ir ir 2" 2*' 3" 31" 4" 503 Black Japanned ... _/6 -/6 -/8 -/I0i 1/2 1/6 2/- 2/4 4/- 4/6 503 Galvanized ... -/7 -m -/I0 I/I 1/4 1/9 2/6 2/10 5/- 5/6 Fig. 502 is also made... Black .......................................... 4/6 Galvanized .............................. 5/6 5" and6" 6/ 7/6 ' -v* PIPE BRACKETS MENTAL HOSPITAL AND PRISON PATTERN MALLEA8LE IRON CRANE 1 // 3" 24 1" i r -/5 -16 -n -/I0 These Brackets are offered for general use in Mental Hospitals, Prisons, etc., where the utmost protection against the illegal use of hooks, brackets, etc., by inmates is desired. STAMPED STEEL Fig. 507 BLACK AND GALVANIZED Fig. 508 BLACK AND GALVANIZED FigNo. 7 3// 8 2\ 3" 4 i" 1 i" li" 2" O \ 3" 3i" 4" 5" 6" 507 Galv. --1is4 -14 -1's -m -isi -m -16 -/Si -17 -16 -S -/7i -m -18 -1 ioi -no ii l/li l/5i l/2i 1/6 1/3 1/7 1/10 2/S 2/S 3/- -is -is508 -14 -4 -I4i -m -/si -16 -/7i -8 -10 l/li l/2i 1/3 i/10 2/S Galv. -/Si -16 -17 -8 -/9i -m i/i ' Si 1/6 1/7 2/5 3/- Fig. 508 can be supplied with Long Shanks at 25 % extra. 167 CRANE PIPE BRACKETS r rFig- No. Sizes: 2It' 3" 4 1" i V 0*21" 3" 3*" 4" 511 Black ... Galvanized ... _ -/4 -m -/s -/6i -18 11- ' __ -- -m -16 -/** -im 1/4 -- _ -- _-- ---- 512 Complete with Pipe-- Black ... -17 -18 -19 ~I9 -ni 1/5 1/6 2/4 2/10 31- 3/6 Galvanized -19 -im 1 /- I/O* im 1/10 l/lli 3/0* 3/8 3/11 4/6 Fig. 513 SOLID HOLDERS Fig. No Sizes: 513 Black ............... Galvanized ... 514 Black ............... Galvanized ... 1 7 -/3 -14 -16 -18 Off 4 -14 -m ~/7* -/*i Fig. 514 SPLIT HOLDERS 1" i r -16 -18 -18 -im -/7 -/, -/II 1/2 -/8 -/l* 1/2 1/6 2" 1/1/3* 1/4 1/9 Fig. 515 BACK PLATES Fig No. Sizes: 515 Black ............... Galvanized ... 516 Black ............... Galvanized ... 1" 8 -m -m -- i tr 4 -m ~/3* -m -m 3" 8 -14 -/si ~/2* ~/3* Fig. 516 CEILING PLATES 1 ft 3ft 24 -/5* -/7 -/4 -/si ~/7 -/? -- I" -/9* I/O* -- 168 1 -------------------------------------------------------------CRANE PIPE HANGERS Fig. No. 517 Black 520 Black 521 Black 522 Black Sizes: ............... ............... ............... ............... i" /-16 -- --' 3* 1/-16 -16 -m LAGSCREWS 38 " I/I* -m -m -m 3// 1" 4 1/3* -im -im -m 2/I/I* I/I* 1/- 3/1/6 -- -- GIRDER LUGS Sizes: 1" 8 \" 4 2." 8 2\" Screwed, with gim let point for wood -IS -/6* -m -m Fig. 524 To pass j" bolts for Hangers up to 3" ... per pair -/9 To pass bolts for Hangers over 3". Heavy Pattern - per pair -/II PIPE RINGS SOLID Fig. 526 Sizes: Screwed for Iron Pipe \ 21 z 3 4^ 4 1" 1 iir// 113?1" 2" r 44 8 ?r 2 3" 11 ft 3*" 1" 4" i" Prices ............... -is -14 -m -IS ~/6* -/7 -/io* I/I 1/4 1/5 169 A- CRANE PIPE HANGERS Fig. 527 MALLEABLE IRON HINGED (COMPLETE) Fig, No. r r 4* r IF if 2" 2i" 527 -m -H -m -is -16 -p -IB -/m 528 -Pi -/4 -Hi -/Si -p -Pi Fig. 528 STAMPED STEEL 3" 3F 4" 1/2 -/I0 l/l'O 1/- V1/2i 5" 6" 8" 2/10 3/4 4/ 1/54 1/7 Fig. 529 PIPE RINGS (split) Fig. 530 PIPE RINGS (DOUBLE) Fig. Sizes: r r r 1" ir 1 i" 2" 2r 3" 3f 4" 5" 6" No. Screwed: r r f r r r r h" 7" F 7,/ r 529 Black Galvd. 530 Black Galvd. ... -/4 -/4 -/4i -/5 -/Si -/Si -n i/- 1/2 1/6 1/10 3/- 4/- ... -/44 -Hi -/54 -16 ... -/4i -Hi -/Si -16 ~Hi -/74 -Hi 1/3 -Hi -/'i -Pi 1/34 1/5 1/11 2/4 1/7 2/- 2/3 3/9 s<4/6 5/6 ... -IS -is -/< -Pi -8 -/i -/ll 1/7 2/- 2/ 2/10 5/7 6/10 Fig. 532 CALLIPER HOOKS Fig, No. Sizes: F i" IF 1 i" r 24" 3" 34" 4" 5" 6" 531 _ _ -Pi -/3 -/4 -IS -/ -/8 1/- 1/3 1/6 2/- 532 Per pair ... -/2 ~Pi -Pi -H -Hi -Pi -/8 -/I0i 2/- 2/4 3/- 4/- 170 -------------------------------------------:----------------------------------------------- CRANE MALLEABLE IRON PIPE HANGERS Fig. 551 Fig. 552 Fig. 553 Fig. 566 Above are combinations built up from separate units Any combination quoted for on receipt of Specification 171 r CRANE---------------------------------------------------------------------------------- ROLLER BRACKETS AND CHAIRS Figure No. Sizes: No. 1 Small For Pipe Sizes up to .............. Vertical Adjustment on largest size pipe .......................... Minimum Distance from Face of Wall Plate to Centre of Roller Maximum ditto ... 3" 2" OX" H" No. 2 Medium 4" 3" 2-jV' No. 3 Large No. 4 Extra Large T 10" 4" 5" 3" 3jf" 7f" 9t%" 577 Single Roller, Bracket and Wall Plate ...................................... 578 Double ditto ditto ... 573 Extra Rollers and Chairs for Figs. 577 and 578 ............... 5/91- -m 8/6 13/6 -/II 13/24/- 2/4 25/39/- 3/3 Fig. 574 Number 1 2 3 4 567 For Pipe Sizes: 2" 2i" 3" 3*' 4" 5" 6" Roller and Chair Complete ... 3/- 3/4 3/6 3/10 4/2 5/- 6/- 172 PATENT CRANE ROLLER PIPE BRACKET BRITISH PATENT 426415 BRACKET ASSEMBLED WITH PIPE LAGGED This entirely new design of Support and Roller Bearing allows for expansion or con traction of Pipe without interfering with or damaging insulating material with which it is covered. For Pipe Sizes: ir 2" 2j" 3" 3T" Pipe Cradles with Clamps, Roller and Plate ...................................... 8/6 9/- 9/- 10/3 10/9 ! For Pipe Sizes: 4" 5" 6" 7" i Pipe Cradles with Clamps, Roller and Plate ...................................... 12/- 16/6 23/- 28/6 BUILD-IN WALL BRACKETS Drilled to receive horizontal flanged base plate of Fig. 591 For Pipe Sizes: i r r2" 2 3" sr Wall Bracket to sup port cradle ... 8/6 8/6 8/6 9/6 9/6 For Pipe Sizes: 4" Wal 1 Bracket to sup port cradle ... 12/- 5" 6" 7" 12/- 15/6 15/6 173 CRANE FLOOR AND CEILING PLATES j Fig. 581 CAST IRON ' Fig. 582 ROLLED STEEL, HINGED Fig. 585 ROLLED STEEL, ONE-PIECE Fig. 588 CAST IRON Figure No. For Pipe Sizes: . Black ............... 58) Nickel Placed ... Chromium Plated Black ............... 582 Nickel Plated ... Chromium Plated r -no 1/8 1/10* -/A -/I0+ 1/2* Fr -/II 1/9 i/m -Hi -im 1/3 -/m 1/9+ V-HOii -mi 1/4 1" 1/1 + 2/1 2/4 -IB 1/0$ 1/6 ir 1/3 2/3 2/6 -m 1/2 MU IF 1/5 2/5* 2/9 -no 1/3* 1/9* 1/8* 2/11 -3/3* 1/1/6 2/1* CM 2/10 4/2 4/9 1/8 2/2 3/0* 3" 3*" 3/9 5/2 _-- 5/10 -- 2/2 2/8 2/8 3/4 3/9 4/8 4" -- -- -- 3/4 4/2 5/10 F/gure No. For Pipe Sizes: 585 Black ........................... Nickel Plated ............... V -/3* -/4* . r -/3* -/5* r -14 -/5* IF --/4* -16 IF -/4| -m V --/5* -Hi No. For Pipe Sizes: r IF IF 2* 2t* 3" 3*" 4" 588 Per doz.................. 2/9 3/- 4/- 5/6 7/- 8/- 15/- 18/- 22/- 26/- Fig. 589 Thimbles tapped for Pipe To pass Pipe ... ... r |ir / IF r ir IF 2" r 2" 2" ir ir 2F IF 2V 2" 3" 2" 3*" 4" 2*" 3" Black ............... each --/5* I -/6 -/A* -/8 | -IB -/9 -/9 | -19 -/I0 -no 1/5 1/10 2/9 5" 4" 3/2 174 CRANE LOUVRED REGISTERS Fig. 90S. PLAIN LATTICE DESIGN PRICES OF COMPLETE REGISTERS laraas-ra-MiST naaaaaBfiaa'' niw=i=fl=fl=ra~i Size of Opening in. 6x8 6x9 8 x 10 Black Japanned * s. d. 75 7 10 10 9 Size of Opening in. 9x9 9 x 14 10 x 12 10 x 14 Black Japanned s. d. 98 10 7 11 6 12 5 Size of Opening in. 10 X 16 12 x 14 12 X 18 Black Japanned s. d. 15 7 15 7 20 8 Fig. 906. Fig. 907. Fig. 908. Extra for White Enamelled Registers and Faces .............. Pulleys for Registers .............................................................. Extra for Fixing if required .................................................. Indicator Handles, blackjapanned, lettered "Open"and "Shut" lOd. each. I/-per pair. 6d. per pair. I Id. per pair. REGULATING QUADRANTS Top action or Side action, state if right or left hand. Rod included up to 3 ft. in length. Fig. 909. Malleable Iron, Black, with Iron Rod ...................................... 3/-each. Fig. 910. Brass or Gun metal, ditto .................................................. 4/6 each. Fig. 911. All Brass, Polished and Lacquered, ditto .......................... 8/-each. Extra for Brass Rods, 3 ft. long ...................................... 1/3 each. PULL-UP ACTION, WITH GUIDE Fig. 912. Brass Knob, Guide and Iron Rod Fig. 913. Brass Knob, Guide and Brass Rod ...................................... 3/8 each. ... ... ............... 5/8 each. DETACHABLE FRONT WALL GRATINGS AND FRAMES SCHOOL BOARD PATTERN WITH FOUR BRASS SCREWS Gratings and Frames are of cast iron, Black, or Galvanized for external use. The front can be detached from the body by removing the Brass Screws. C.l. AIR BRICKS--BLACK 9" X 6* s. d. rxr s. d. 12" x 6" s. d. 12" x 9" s. d. 38 42 46 51 C.I. AIR BRICKS--GALVANIZED to X O' 4 r x 6" s. d. rxr s. d. s. d. 12" X 9" s. d. S6 6A 69 78 12" X 12" s. d. 64 12" x 12" s. d. 99 14" x r , s. d. 60 14" X 9" s. d. 95 18" x 6" s. d. 62 18" x 6" s. d. 9 10 18" x 9" s. d. 74 18" X 9" 5. d. 11 10 175 CRANE SOLID STOCKS AND DIES MALLEABLE IRON LIGHT IN WEIGHT STRONG COMPACT PERFECT CUTTING Fig. TS FOR SCREWING PIPE BRITISH STANDARD PIPE THREAD Fig. T6 FOR SCREWING BOLTS WHITWORTH STANDARD THREAD Figure No. T6 Solid Die-stocks for Bolts-- VNo. OSL2 r. no. osl3 r. no.isli i", 1". r. r, rr.. rr.. r r .................................................... r,no. isl4 no. isls r. r. r. r. r, i". irf.. irf. ......... r. ... no. i{sl2 i", r, i", ir, ir, if......................... s. d. 2 5 10 2 5 10 326 3 19 2 4 15 10 476 For Spare Parts--see General Catalogue. 176 V CRANE ADJUSTABLE STOCKS AND DIES GENUINE ARMSTRONG Fig. TIS FOR SCREWING BRITISH STANDARD PIPE THREADS Set No. 1 2 2A H 3 3A For Screwing Pipes a\//> 4\//> 8\/f 1 4 // 1 // 4 3"5'7 r> r. s3'// | // 'S 8Z"* l" "i * l // 2 34-7 rxr. ** 43" \" 1 I* 7/ rxif *** ** ** ** ...................................... If', If', 2" ......................................................................... 1", If', If', 2" .............................................................. Price each complete 37/6 58/4 50/79/2 75/87/6 Sets are packed in substantial wooden boxes, complete with dies and guides. Fig. TI6 FOR SCREWING WHITWORTH STANDARD BOLT THREAD Set No. _For Screwing Bolts Price each complete 1 > > 1" 5" 1" 4 T7 8 jj* \ 16 2 2." 2." 84 *** 62/6 1 r. *". r. v, r. r- with7TaPs........ 81/3 2 2 * $ >1ff S" 3" t4 7" 8 \" \\ 1 *8 * \" *4 ** ** "* 83/4 2 f, |", r. 1". 1". ir. It'. With 7 Taps........ 133/5 !, , i . Dies are interchangeable in the Stock without altering the adjusting screws. 5 Sets are packed in substantial wooden boxes, complete with dies and guides. For Spare Parcs--see General Catalogue. 177 M CRANE OSTER STOCKS AND DIES " BULL-DOG " The list prices include the stock or die holder, a complete set of right-hand pipe dies and a set of tubular handles. Set Nos. Ill to 1145- Nos. 115 to 117 are made with four handles in the body " Bull-Dog " Sets are not made with cut ting-off appara tus. These Tools can be equipped with dies for left hand. "BULL-DOG" RATCHET TYPE These sets are made with two handles in the body and with one handle in the ratchet part, so that the tool may be used at wi 11 with two hand les as a regu lar or with one hand le as a ratchet. Two handles are supplied with each tool. Set No. 117R. is made with four handles in the body of the tool and with two handles in the ratchet part, so that the tool may be used at will with four handles or with two handles as a ratchet. Four handles in separate box are supplied with each tool. For Spare Parcs--see General Catalogue. OSTER STOCKS AND " BULL DOG " CRANE DIES For Screwing Iron Pipe: Fig. T40 PLAIN Fig T4I RATCHET Set No. Except No. 1I4X, which is for B.S.T.I Copper Pipe No. of Dies Price per Stock Complete Set Sets of Dies Price No. per Stock Complete in in* 112 113 114 II4X 114* 115 115* 117 117* and 4"; " and 4"........................... *", *" and i"; *" and i" .............. i" and 4"; 4" and 4"; T and 14" ... I"andT"; 14" and 2" ............... 4" and i"; \" and 14"; 14" and 2" ... i'. 1". 1*". I*"and2" ... *" and *" and 1" and 1*"; 1*" and 2"...................................... 14" and 2"; 24" and 3" ............... 1" and 1*"; 1*" and 2"; 2*" and 3"... 24"and 3": 34" and 4" ... ... 14" and 2"; 2\* and 3"; 34" and 4"... 2 3 3 2 3 3 4 2 3 2 3 70/10 83/4 91/8 100/116/8 141/8 133/4 175/-' 204/2 208/4 241/8 112 R 113 R 114 R -- 114*R 115 R 115R 117 R 117*R -- 3 2 --3 4 2 3 2 3 -- 116/8 125/141/8 -- 158/4 250/279/2 291/8 325/- * No. II4X is supplied with Dies for B.S.T.I Copper Pipe, but is graduated for both Iron and Copper Pipe CONDUIT STOCKS AND DIES Set No. INC No. of Threads per inch II2C No. of Threads per inch 113C No. of Threads per inch 4" and To Screw Pipe: 4" and 1" ...................................... No. of Sets of Dies per Stock 2 18 16 4" and 4" and 4"; l" and l"; 14"............... 4 18 16 16 14 4" and 4"; 1" and 14"; 14"; 2".......................... 4 18 16 14 14 Fig. T42 Price Complete 83/4 135/5 166/8 Fig. T46 Dies per set 18/9 21/11 75/- DIES FOR OSTER " BULL DOG " DIESTOCKS Fig. T45 . Set Nos. To Thread Pipes r. & rr 4". & r4" r& r rir& r& ir 14" & 2" V 24"& 34" & 3" 4" 111 ...............' ... M2 and 112 R ... 113 and M3 R ... 114 and 114 R ... M4X .......................... 1144 and I I44R ... 115 and M5 R ... 1154 and 115|R ... 117 and 117 R ... 1174 and M7*R ... per set ,, ,, ,, ,, ,, ,, ,, ,, 12/6 14/7 25716/8 12/6 14/7 14/7 16/8 16/8 16/8 16/8 16/8 29/2 25/- 16/8 16/8 > 16/8 29/2 29/2 25i- 33/4 29/2 29/2 33/4 33/4 33/4 33/4 The list prices include the tool or die holder, a complete set of right-hand dies and a set of tubular handles. The tool is delivered ready for use. For Spare Parts--see General Catalogue. 179 CRANE OSTER RECEDING STOCKS AND DIES "LEADER " " RECEDER" Fig. T50 PLAIN AND RATCHET TYPE Nos. I and I A. Fig. TSI GEARED TYPE Pipe Threading Sizes: Number of Sets and Dies: Tool complete with one set of Dies for each size Pipe ........................... Extra Dies per set (any size) ... Fig. T50 No. 1 No. 1A Plain Type Ratchet Type With Universal Chuck With Chuck \" to 2" 4 1" to 2" 4 4 0 0 4 pieces 6/3 5 0 0 4 pieces 6/3 Fig. T5I Geared Type With Universal Chuck 2 to 4" 4 20 16 8 5 pieces 33/4 Fig. T50 is an easy screwing tool having dies which are only half the usual width, so that there is only half the friction to overcome. These dies are double taper, the first few teeth do the roughing, the others the finishing, and the dies automatically expand as the thread progresses, so producing the correct taper for pipe threads. The tool is made in the plain and ratchet types. Fig. T5I is made in the geared type. The lead screw pulls the dies on to the thread without any effort on the part of the operator. This screw is protected by a chip shield which prevents chips getting into it. When the thread is finished the lead screw is unwound. The back ends of the dies, instead of being square, are bevelled or cut at an angle. This bevelled end of the die bears against a fixed post, so that, by moving the die sideways it is drawn in or out. The tool is quickly adjusted to screw over or under size threads as rotating the die head one way or the other permits the die to automatically expand or contract. CRANE OSTER PORTABLE HAND-TOOL DRIVE "POWER BOY" A PORTABLE DRIVE FOR PIPE TOOLS Fig. T60 Size No. 412 (with Electric Motor) Size No. 412. For Screwing, Cutting and Fitting Pipe up to 2". ,, No. 414. ,, ,, ,, ,, ,, ,, to 4" TOM THUMB MACHINES For further particulars of above Machines--see General Catalogue. 181 CRANE TOLEDO STOCKS AND DIES RATCHET ADJUSTABLE No. T84 Capacity \" to 2" Equipped with a Ratchet, this is one of the most popular I" to 2" threading devices on the market. Excellent for work at close quarters. PRICE.......................... 4 3 0 EXTRA DIES: I", l" or 1-i" ... per set, each size ............... ... 2" .............. ,, ,, .................................... 7/6 H/6 No. T85 Capacity 2" to 3" Light and compact, weighs about 37 lbs. Direct acting and using "TOLEDO " receding die principle, operates more easily on these sizes than other direct-acting tools. PRICE .......................... 9 7 6 EXTRAS: Dies, each size ... ... per set 1 I 6 182 CRANE TOLEDO STOCKS AND DIES GEARED ADJUSTABLE Considered by many to be the easiest operating large stocks and dies on the market and have been standard with experienced operators for years. Easily operated and produce smooth, perfectly tapered standard threads. Will work in restricted quarters. Operated either by ratchet handle or instantly converted into power machines with a "TOLEDO" Power Drive. Driving pinions with an oil reservoir assure proper lubrication. Gears are guarded and all tools are strongly built. Size No. 2 weighs 84 lbs. net, uses a separate set of dies for each size pipe within its capacity. Size No. 25 weighs 200 lbs. net and uses one set of dies to thread all sizes from 2?" to 6". Easy, positive die change. An extra set of die? is furnished with each tool. Size No. 3 weighs 215 ibs. net and uses a separate set of dies. Special 4" dies and 4" bushing can be supplied. - Size No. 2. No. 25. No. 3. R.H., threads 2{" to 4" inclusive R.H., threads 2{" to 6" inclusive R.H., threads 4j" to 8" inclusive List Price 16 4 0 38 0 0 50 0 0 183 A r THREE-WHEEL PIPE CUTTERS Fig. TIIO Figure No. Size No.: 101 102 103 104 105 106 To Cut Pipe ins. i~l 4--2 14-3 24-4 4-6 6-8 TIIO Complete ... .. each 18/9 25/- 42/- 84/- 125/- 166/- Till Wheels (Smooth) ,, I/I 1/3 1/8 2/1 3/2 3/2 TII2 Wheels (Knurled) Tl 13 Pins ... ) >> 1/7 -/5 1/10 2/6 -IS -is 3/1 4/9 4/9 -/84 -m -m CHAIN PIPE CUTTERS Fig. TI20 This Cutter is particularly suitable for cutting cast iron pipe in confined spaces. Figure No. Size No.: 3 4 5 6 7 8 9 10 11 12 13 14 TI20 TI2I TI22 No. of Wheels ... To Cue Pipes ... Complete ... Wheels............... Pins ............... 5 6 7 8 9 10 5 6 7 8 9 to 2"~3" 2"-4" 2"-5" 2w-4" 2"-7" 2"-8" 5"-6" 5"-7" 5-ff8" 5"-I0" 5w-i r 5"-l3" 40/- 45/- 50/- 55/- 60/- 65/- 65/- 72/6 80/- 87/6 95/- 102/6 1/4 1/6 1/6 1/6 1/6 1/4 2/3 2/3 2/3 2/3 2/3 2/3 -16 -H -It -It -/ -It -17 -/7 -/7 -/7 -/7 -/7 184 PIPE WRENCHES STILLSON'S PATTERN CRANE Fig. TI25 TI26 (with Wood Handle) Fig. No. Length: Takes pipe from TI2S Steel Handle ... 6" 81 >f to 2t" -- 8" 10" 14" 18" 81" 1a " 1" 4 |/' 4 to to to to 3" 4 1" 1V 2" 9/3 12/- 16/- 23/- TI26 Wood Handle Price ... each 8/4 9/6 13/3 17/9 -- 24" \'t 4 to 91" 39/6 -- 36" 1 >' 4 to 3*' 83/6 -- 48" \n 4 to 5" 125/- -- CHAIN PIPE WRENCHES DROP-FORGED STEEL DOUBLE-ENDED REVERSIBLE JAWS With Double-Ended Reversible Jaws for gripping pipes, pipe-fittings, etc., from -g" to 12" diameter. The Connecting Link swings freely on a sleeve or bush, which is tightened between the prongs of the lever head by the centre stud passing through it. This holds the Jaws absolutely rigid and prevents working loose. The Chain is made from High Tensile Steel, subjected to special heat treatment, and is tested and guaranteed to give dependable service. The Jaws are carefully hardened and tempered to ensure long life. All parts are interchangeable with standard make, and are fully guaranteed against defect in material or workmanship. Figure No. Size No.: 230 TI36 Price .......................... 21/- Capacity, Size Pipe ... y" to Length over all............... 14" Weight, approx, (lbs.) 2i Average Breaking Strain of Chain (lbs.) ... 2,500 231 232 233 233* 234 235 29/- i" co It" 20" 41/6 i" to 2i" 27" 10 58/6 }" to 4" 37" 16 75/- 1" to 6" 44f" 24 91/6 ir to 8" sor 32 ISO/- 2" to 12' 64" 50 6,800 9,600 12,600 14,100 15.800 21,600 185 CRANE------------------------------------------------------------------------------------------------------------ CHAIN PIPE VICES " VULCAN " PATTERN for Size Taking No. Pipes Jaws per pair Prices, Complete and Parts Chain Handle with Screw and Screw Nut Nut Price com plete 181 r-2" 12/6 10/6 3/6 9/3 5/9 29/182 r-4" 29/3 20/- 5/9 17/6 11/3 62/6 183 *"-6" SO/- 37/6 10/6 29/3 16/9 112/6 184 r-8" 75/- 50/- 10/6 29/3 16/9 150/- Fig. TI55 Sizes Nos. 181 and 182 are packed in boxes for convenient transit and storage. Orders for chains include screws unless otherwise stated. OPEN SIDE PIPE VICES Figure No. Size No.: TI57 To take Pipe ............... Price........................... 61 8 *4 17/6 62 ^1 O'/ 4 25/- Fig. TI59 MALLEABLE IRON 63 64 r-3" 34/- r-4" 48/- 66 l"-6" 100/- Figure No. Size No.: TI59 To take Pipe ............... Price........................... 31 r-t" 13/- 31* r-ir 17/6 32 r-2" 22/- ' -- -- 186 T CRANE HINGED PIPE VICES To take Pipe V Up to: 1" ir 2" 2i" 3*" 4*" 6" Size Nos.: 91 914 92 92* 93* 94* 96 TI6I each 12/6 15/- 17/9 20/9 31/3 45/9 98/- Extra Jaws (set of 3) 5h 6/3 7/6 7/6 10/6 IS/- 25/- Size 91 is only suitable for electrical conduits For Spare Parcs--see General Catalogue. BURRING REAMERS TANK CUTTERS Fig. No. T200 No. For Pipe Sizes Ins. Price s. d. 1 i t * 46 2 i,,1 3 1 11 4. *4 66 80 4 1 ,,2 13 0 Fig. No. T204 Complete with Cutters and Pads for holes to suit *" to I*" wrought Pipe inclusive. Price ... 2 14 0 UNION WRENCHES For Union Tail-pieces of Crane Radiator Valves. Fig. T209 Malleable Iron black japanned. Price ... 2/- each. Sizes * in. to I* in., inclusive. 187 1 Fig. TI73 Figure No. Size Nos.: 00 0 1 2 3 4 5 6 7 8 Width of Jaws TI73 Jaws, open r H"O 1 M 9cJ2." 3" 3 4" 5" 6" 7" 8" H"24X4 " 2" H" 4" 4J' 6i" 8" 9i" 9*' Price, each ... 10/6 12/- 14/6 19/6 25/- 33/- 41/- 55/- 65/- 72/- PORTABLE VICE Figure No. Description Price TI65 With Pipe Vice for Tube up to 2" (illustrated) ............... TI67 With Bench Vice and Pipe Vice TI69 With self-locking hinged Pipe Vice for pipes to 2" ... 48/72/- 54/- TI7I With "Vulcan" pattern Chain Pipe Vice ... No. 1 r-2" 58/- No. 2 r-i" 95/- HACK SAW FRAMES ADJUSTABLE 8 IN. TO 12 IN. CRANE Price 3/4 each Fig. TI87 HACK SAW BLADES Fig. TI89 For cutting Solid Steel or iron Tubes, Brass and Soft Metals, etc. Stock Sizes 8" X i" x 23g 9" x x 23g FOR HAND Per Gross Stock Sizes 33/4 10" x X 23g 37/6 12" x X 23g Per Gross 41/8 50/- DOUBLE-EDGED BLADES Fig. TI93 Length (I" wide) x 21g. 9" Price per gross............... 81/- 10" 90/- 12" 108/- 14" 126/ Specially recommended for cutting soft metals, such as Lead, Copper, Brass, etc. They are made of very best quality Tungsten Alloy Steel, hardened in the teeth only. KEY SPANNERS FOR RECESSED PLUGS CARLTON AND WHITEHALL BOILERS. --r A For f" and Plugs. No. T85I Price ... 2/3 For I*', 1" and 2" Plugs. No. T852 PRICE ' ... 2/3 1" ... 3/6 r - 3/6 2" ... 5/- BOILER WRENCHES For Assembling Whitehall Sectional Boilers. Fig. 840. Wrench, J" for Nos. 1, 2, and 3; l" for No. 4, each 7/9 189 1 CRANE ----------------------------------------------- SUNDRIES CRABENITE ASBESTOS COMPOSITION SHEET PACKING This High Pressure Jointing is particularly suitable for flanged joints on high and low pressure, super heated and saturated steam, acids, ammonia, oil, alkaline and hot liquid pipe lines. The weight of a sheet 40" square by -fa" thick is about 7 lbs. The weight of a sheet 40" square by " thick is about 14^- lbs. Best Quality 5/- per lb. 400 lbs. S.W.P. Junior 3/4 per lb. 200 lbs. S.W.P. Usually supplied in sheets and rolls of 40" by 40". Sheets of 48" by 48" can be supplied. Prices for Gaskets made from above Packing will be given on application, stating dimensions. TAYLOR'S BRASS CORRUGATED JOINT RINGS (TO LIE INSIDE BOLTS) Bore of Pipe 2 2" 3"3" 1" i r ir 4 W B.S.Tables D&E -16 B.S. ,, F,H,&J -16 -19 -19 1/1 /- 1/3 1/3 1/6 1/6 y2/3- 2/6 3/- 3/3/6 -- .-- -- Bore of Pipe B.S. Table 1 B.S. Table 2 3** 4" 5" 6" 7" 8" 9" 10" 12" 3/6 4/- si- 61- 71- 8/- 91- 10/- '2/; 3/9 4/3 5/9 6/3 7/3 8/9 9/3 10/3 12/3 Fig. CHI Prices are per dozen Rings to cover the full diameter of British Standard Flanges can be supplied. BOLTS AND NUTS Fig. C97 Hex. round hex.--Black Size ir i r Length 2" 9441" 2i" 2" 3" \ 2 25/9 26/10 27/11 29/- 30/1 31/2 32/3 8S 391- 40/6 42/- 43/6 45/- 46/6 48/- 3// 4 591- 61/- 63/- 65/- 67/- 69/- 71/- Prices are per gross. 190 T1 CRANE SUNDRIES PIPE JOINT COMPOUNDS Fig. E290 GRAPHITE Fig. E292 "BOSS WHITE" GRAPHITE Fig. E290. Superior to red or white lead and more econo mical. The Compound is put up in I lb., 2 lb., 5 lb., 7 lb,, and 10 lb. tins, mixed ready for use. It is absolutely non-poisonous; is largely used on Taylor's Corrugated Joint Rings, and ail Screwed or Flanged Connec tions for steam, water, gas, air, etc. "BOSS WHITE" High grade non-poisonous White Compound, for Screwed and Flanged Joints on steam, water, gas, oil, ammonia, etc. Especially suitable for exposed pipework in interiors. Price per Tin or Keg: E290 \ E292 J 1 lb. 2 lbs. 5 lbs. 7 lbs. 10 lbs. 28 lbs. 56 lbs. 112 lbs. 1/3 2/3 S/3 6/9 */- 24/- 46/- 90/- THE UNDERMENTIONED ARTICLES ARE OF FOREIGN MANUFACTURE. MADE IN U.S.A. No. Page / Sizes No. Page Sizes No. Page Sizes 121 151 1" 4* 3." 8 > OX." ^W 222 159 ri , iix4" F35I/2 129 Al 1 sizes 6"138 152 3" ||# I | // rt// F '4 * 12 L 241 161 Wi" 140 152 3", H", 5", A1 165 1" 3" 4 '8 rHI0I 114 ' HI2I 127 r, IF. IF. 2" 152 153 2"x IF A6 165 1 4 " 3" 8 H2II/3 107 All sizes 163 154 Jr a."* 34 " i*"* ii" All/12 165 All sizes T5/6 176 All Nos. \ 2", 2f". 3" A35 165 All sizes TI5/6 177 All Nos. 221 159 JL" 3" J" 24 E2I0 103 -- All "Oster" and "Toledo" threading devices, pages 178 to 183, made in U.S.A. Nos. TI6S and. TI67, page 188, MADE IN GERMANY 191 CRANE 1 I CONDITIONS OF SALE Customers are respectfully informed that all quotations are subject to these conditions unless specifically varied by us in writing. NEW ACCOUNTS.--New customers wishing to open accounts should forward Trade and Bankers' references with their initial orders. ORDERS.--When ordering goods the exact size, catalogue figure number, and descrip tion should be stated. PRICES AND DISCOUNTS.--The prices and discounts quoted, whether in this catalogue, or in any other list or quotation, are subject to alteration without notice. The right is reserved to make any increase in quoted prices rendered necessary by or arising from a labour award or other cause beyond our control. STOCK.--Goods offered from stock are subject to remaining unsold. DELIVERY.-- . GREAT BRITAIN.--Either by our own lorries (within our delivery area), by Public Carrier, or to nearest Railway Goods Station ONLY, unless free delivery to des tination is included in the rates charged by the Railway Companies. Goods, when sent by our own lorries, will be delivered free (within our delivery area) on regular delivery days; otherwise carriage for orders under minimum carriage-paid values will be charged on invoice at usual rates whether sent by our own lorries, public carrier or rail. IRELAND.--To Seaport only (not including delivery, and excluding Irish Free State Customs Duties) except by arrangement. Radiators. Carriage paid on orders of 4 net value and over. Combined Orders for Radiators and Heating Specialties (except W.l. Fittings, Tanks and Cylinders) delivered Carriage Paid on orders of 4 net value and over. Concealed Radiators with Cabinets, Fronts, or Grills, Carriage Paid on orders of 7 net value or over. Boilers. (All) irrespective of value, Carriage Paid. Parts of Boilers. 4 net value and over, Carriage Paid. Heating Specialties (except Tube and W.l. Fittings, Tanks and Cylinders), supplied with Boiler, delivered Carriage Paid. Combined Orders for Radiators and Boilers of 4 net value and over, delivered Carriage Paid. Oster Screwing Machines. Carriage Forward. Galvanized Storage Cylinders. (Not Indirect). Tanks and Cisterns. Carriage Paid in England, Scotland, Wales, and to approved Irish Ports. Tubes and Wrought Fittings delivered Carriage Paid only on orders of 10 value and over. Compression Joint Fittings delivered Carriage Paid on orders of 10 net value and over. Copper Pipe delivered Carriage Paid on orders of 3 cwt. lots and over. Other Goods delivered Carriage Paid on orders of 7 net value and over, except where otherwise quoted. EXPORT.--Packing and Delivery to Wharf or Ship will be charged extra at cost, unless otherwise specified when quoting. TIME OF DELIVERY.--Every endeavour is made to ensure prompt delivery, but lateness in delivery shall not entitle customers to cancel contracts unless we specially agree thereto in writing, and no claims for consequential damages, loss of time sustained, cost of repairs executed without previous consent or any claim whatever in conse quence of late delivery shall be made by customers. DELAY.--When a delivery date is named, this is subject to strikes, lockouts, accidents, government requirements, delay occasioned by the procuring of material or com ponent parts, and all other unforeseen circumstances and causes beyond our controlWe accept no contingent liability on account of delays in delivery. These conditions are subject to amendments appear ing from time to time in our discount sheets. ' j ! 192 CRANE CONDITIONS OF SALE-continued. PACKING.--Radiators and Boilers. Packing crates, cases and protecting strips are charged for at nominal prices only and are not returnable. Crates for Whitehall Boiler Jackets will be credited if returned in good condition to Ipswich Works Carriage Paid. PACKING.--General. Bags are charged at half-cost and are not returnable. Cases, where not included in price, also containers for Copper Indirect Cylinders and for Towel Airers, are charged at cost and full credit will be allowed if returned in good condition to Ipswich Works, Carriage Paid Home. BREAKAGES AND SHORTAGES.--No goods damaged in transit will be replaced unless Carriers are advised within 24 hours of receipt of goods. Contents of packages should be examined on arrival and checked with Advice Notes, and Carriers advised imme diately of any breakage or shortage. At same time as Carriers are advised duplicate advice must be forwarded to us. Damaged goods should be returned by same Carrier who delivered, consigned "Carriage Free: Broken in Transit." WORKING PRESSURES--REPLACEMENTS.--Test or Working Pressures stated in our Catalogues, printed matter, quotations or correspondence are only mentioned as a guide and for the assistance of our customers. We accept no responsibility should the fittings fail in practice, even though the pressures stated are not exceeded. All goods found defective, when used for the purpose for which they were manufactured, will be replaced free of charge, at point of original despatch, provided the defective goods are returned to us for examination within 10 days of their receipt. No claim for consequential damage is to be made nor will be entertained. Goods not of our manufacture are guaranteed only to the extent of the Maker's warranty and without any further responsibility on our part. RETURNS.--Goods returned by customers (other than those which are defective) will, if accepted by us, be credited at the price charged by us, less a charge for handling and expenses of 10 per cent. Goods may not be returned without our permission. DIMENSIONS AND ILLUSTRATIONS.--The dimensions and illustrations appearing in our catalogues have been prepared with every care, but the correctness thereof is not guaranteed and we reserve the right to vary the details. Exact dimensions can be had on application. TERMS OF PAYMENT--HOME TRADE.--All accounts are due for payment on or before the end of the month following that in which the goods are despatched.Wrought Iron and Steel Tubes, Wrought Iron Fittings and Wrought Iron Flanges: STRICTLY NET. Other Catalogue items are subject to 2 per cent settlement discount if paid by the due date as stated above. TERMS OF PAYMENT--EXPORT TRADE.--Goods for shipment are sold on the basis of cash against documents or cash within 7 days from the date of Invoice, whichever is the shorter period, and in either case net unless otherwise quoted. In all cases of goods for shipment the date of the invoice will be the day when the goods, whether a portion or the whole of the order, are packed in our warehouse ready for despatch. Where shipment is made through customers' own Shipping Agents, "Documents" is understood to mean Wharfingers ' or Port of London Authority Receipt when goods are shipped from London, and signed "Railway Receipt" when goods are shipped from any other port. . SPECIAL ORDERS.--Whenever an order has been given and accepted for goods to be specially manufactured, no cancellation of such order is to be demanded and will not be permitted until the written undertaking of the customer to pay for the special work performed in respect of such order has been received. EXPORT (SPECIAL NOTE) INSPECTION.--The goods offered herein are open for inspection at our Warehouse or Works before despatch, and our responsibility ends with clean receipts from either the Forwarding Company or Shipping Company. These conditions are subject to amendments appear ing from time to time in our discount sheets. 193 N CRANE USEFUL DATA FOR ARCHITECTS AND HEATING ENGINEERS The following tables and data compiled from the findings of various accepted authorities and, in the case of heat losses - through building materials, either from the results of tests conducted by the Department of Scientific and Industrial Research, or from information given by Manufacturers of certain materials. All Data has been reviewed and brought up to date where necessary. The Data has been prepared with an in timate knowledge of the requirements of Heating Engineers in preparing their schemes, and it is hoped that as such the contents will be found acceptable. In addition to matter contained in previous catalogues, tables on chimney flues, pipe sizing, etc., have been added. Whilst every care has been given to their preparation, the information and figures can not, of course, be guaranteed. -CRANE HEAT LOSS COEFFICIENTS (AIR TO AIR) B.Th.U.s per hour per square foot of surface per degree difference (Fahr.) Brick WauuS. Brick Wauls. Plastes orvieT Side . K Q.4-5 9 0.55 I5*la 0,25 18 O.gg gg 0.13 gg. Q. IT <D br ICK WAt-US . @ BRICK 2 Air Space. - Puast'o X. K. II 025 IG 0-20 go 017 34 0-15 28 0*14 Hollow Flextons. Pln T. K. 4''2 0-42 3 0*30 I3`'2 0*23 Brick Wauls Portland Stoine Stohb & Brick Plast'd T Ti K. 9 0*31 9 9 0*2jT 12 9 0-23 Concrete Walls Pl_A.lfN|. if ktf U-T -*l T K. A 0-70 > 0-58 8 0-51 lO 0-45 IS 0-4! l> 0*34 *-T -h-T- &) Concrete Walls, Plaster one Side.. gM n K!1)*. A L-T-* T. K. 4- 062 Q> 0-52 8 0-46 IO 0*41 IS 0-38 IG 0-32 195 CRANE HEAT LOSS COEFFICIENTS (AIR TO AIR) B.Th.U.s per hour per square foot of surface per degree difference (Fahr.) .Sa.(sosTone a. Granite Wauls. ^ANDsroNE Wauls. Pi_/xtrs. With Battens latw* plast . T. K. & 0.56 IS 0.4-7 IG, 0.4-3 IS 0.33 24 o.33 Walls. K--T --*i Limestone T. K 8 o.5o IS 0.40 16 0.35 IS 0.33 24 0.28 Walls. PL.A1f>l. With Battens Lath & Plast X K. X. K. 6 0.60 8 0.50 IS 0.45 IS 0.40 IS 0.4S IS 0.41 24- 0.35 16 0.36 0.34 24* 0.30 ASBESTOS WALLS. STEEL WAULS '<4* Thick Corrugatso K. 1-25 >6" THICK CORRUGATED K. 1.50 $ Steel Walls. Steel. Walls. Plain 3/i6 Thick. k. 1.20 CRANE HEAT LOSS COEFFICIENTS (AIR TO AIR) B.Th.U.s per hour per square foot of surface per degree difference (Fahr.) WEATHER BROS. LATHS PuAST, \3) Hollow Partitions. ,24) hollow Partitions. 4" Pi_ast'o one Side.. 4" Plast'd Both Sides. *r. K. 4 0.35 CRANE HEAT LOSS COEFFICIENTS B.Th.U.s per hour per square foot of surface per degree difference (Fahr.) FLOORS--Heat loss downwards 1 Fig. 25 4 In. Concrete on earth.............................................................. 6 In. Concrete on earth.............................................................. Coefficient 0.55 Coefficient 0.49 Fig. 26 l-in. Wood Blocks, -jn. Screed and 5-in. Concrete on earth Coefficient 0.25 Wood Block Floor in. thick on Cement Screed and 6-in. Hollow Tile Fireproof floor plastered under ............... ........................... Coefficient 0.15 Ditto, but not plastered under ... ... ... ... Coefficient 0.18 Boarded Floor I in. thick on Joists with 9-in. Air Space under and 4-in. Surface Concrete .......................................................................... Coefficient 0.07 Board Floor I in. thick on Joists with unheated and enclosed room under. Coefficient 0.20 Board Floor I in. thick on 7-in. Joists with plastered ceiling and unheated enclosed room under .................................................. ............... Coefficient 0.08 198 CRANE HEAT LOSS COEFFICIENTS (AIR TO AIR) B.Th.U.s per hour per square foot of surface per degree difference (Fahr.) FLOORS--Heat loss downwards (contd.) Fig. 33 Wood Block Ii in. chick on Cement Screed and Concrete 6 in. chick with piaster under ...................................................................................... Coefficient 0.20 Ditto Concrete 7 in. thick .................................................. Coefficient 0.19 Ditto Concrete 8 in. thick .................................................. Coefficient 0.18 ROOFS (flat) AND FLOORS (Heat loss upwards) Fig. 32 Asphalt in. thick on Cement Screed and Concrete 6 in. thick with plaster under Coefficient 0.32 Ditto Concrete 7 in. thick ... ....................................... Coefficient 0.30 Ditto Concrete 8 in. thick ... ... ... ............... Coefficient 0.28 Ditto Concrete 9 in. thick ... ... ........................... Coefficient 0.27 Fig. 34 Lead or Zinc Roof on $-in. Boards and 9-in. Joists with plaster under, Coefficient 0.20 Fig. 35 Asphalt in. thick on Cement Screed and 6 -in. Hollow Tile Fireproof Roof with plaster under .......................................................................... Coefficient 0.22 Fig. 36 Board Floor I in. thick on Joists. Cold air above Coefficient 0.44 Fig. 37 Boarded Floor I in. thick on Joists with Lath and Plastered Ceiling. Cold air above Coefficient 0.18 199 CRANE HEAT LOSS COEFFICIENTS (AIR TO AIR) B.Th.U.s per hour per square foot of surface per degree difference (Fahr.) CEILINGS AND ROOFS 1 (Closed Roof Spaces) Fig. 38 Fig. 39 Fig. 40 "'d- Slates or tiles on battens and rafters only. Lath and plaster ceiling to room Ditto, with l-ln. tongued and grooved boards under tiles ............... Ditto, with Roofing Felt between tiles and boards...................................... Coefficient 0.35 Coefficient 0.25 Coefficient 0.19 Fig. 41 Fig. 42 Fig. 43 Fig. 44 Slates or tiles on battens and rafters only ............... ............... ... Coefficient 0.80 Ditto, but with l-in. tongued and grooved boards......................... . ... Coefficient 0.35 Ditto, with Roofing Felt between tiles and boards ... ... ... ... Coefficient 0.25 Slates or tiles on I-in. tongued & grooved boards, & lath & plaster ceiling as shown Coefficient 0.30 HEAT LOSS COEFFICIENTS (AIR TO AIR) B.Th.U.s per hour per square foot of surface per degree of difference (Fahr.) GLASS Single Windows .. Double ,, .. Single Skylight .. t Double ,, .. 1.07 tt 0.60 it 1.16 0.62 DOORS All wood................................................... Ditto. Upper portion glass panels .. All glass, wood framing .. .. All steel................................................... Ditto. Upper portion glass panels .. All glass, steel framed........................... 0.45 a 0.75 a 0.95 tt 1.20 it 1.15 a 1.05 FACTORY ROOFS Corrugated Iron (unlined) .. .. Corrugated Asbestos Cement Sheeting (unlined) ....................................... Glass North Lights ........................... a 1.80 a 1.45 a 1.20 CRANE AVERAGE RADIATOR TRANSMISSIONS B.Th.U.s per square foot per degree difference per hour. Position of Rodiotor Radiator fixed from Fitted with Crane De flecting Shield * ... In open recess not less than 3" clear of radiator top and sides ... 2-Col. 4-Co/. 6-Cal. Window Walt Hospital Hospital Hospital 3" wide 5$" wide 7V' wide w2 co 2? ES k. o 2-9 U to 2 $2 SlO o CM $22 eEOo ijio L. O 2 c n'0 2^ 2 S uO.'OO DO CO SW 't?o uo 2 1v ?to UDCJ li co Io -t?o } 1.85 2.10 1.70 1.95 1.60 1.82 1.58 1.80 1.71 1.9! 1.85 2.10 1.58 1.80 1.51 1.71 } - - 1.75 2.00 1.65 1.90 1.65 1.89 -- - - - - -- - - l 1.70 1.95 1.55 1.76 1.47 1.66 1.45 1.67 1.55 1.78 1.70 1.95 1.45 1.67 1.40 1.60 J * Represent equivalent heating effect at lower levels of room (see page 14) TRANSMISSION TABLE FOR RADIATORS FIXED 2f" FROM WALL British Thermal Units per sq. ft. per hour Radiator 2-Col. Pall Mall 4-Col. ,, ,, 6-Col. ,, ,, Window ... Wall .............. 3" Hospital r5 ,, 7r -... - 70 116 105 100 99 106 116 99 94 Temperature Difference (Degrees Fahrenheit) Water Steom 80 90 100 no 120 155 160 140 162 185 208 233 327 340 128 150 170 192 215 300 312 120 140 160 180 200 282 294 119 138 158 178 200 278 290 128 150 171 192 215 300 312 139 162 185 208 234 327 340 119 138 158 178 199 278 290 113 132 151 170 190 266 275 HANDY RADIATOR TRANSMISSION TABLE FOR RADIATORS FIXED 2f" FROM WALL Room Temperature 2-Column ... 4-Column ... 6-Column ... Wall ............... Window............... 3" Hospital ... S3." 7V ,, Hot Water Gravity Circulation (mean Rad, temp, assumed I556F.) Accelerated Circulation (mean Rad. temp, assumed 170F.) 55F. 60F. 65F. 55F. 60F. 65F. 185 174 162 215 208 194 170 159 150 196 192 179 160 150 140 185 180 168 171 159 150 196 192 179 158 148 138 183 178 166 185 173 162 215 208 194 158 148 138 183 178 167 151 142 132 175 170 159 Steam LP or Vapour Systems (Rad. temp. assumed 2I5F.) 55F. 60F. 65F. 138 327 315 310 292 300 282 290 270 310 300 290 288 338 278 327 270 315 290 275 278 266 2/u 253 It is recommended that radiators be fixed as far from the wall as the situation will allow, in order to obtain the maximum heating effect. 2j" is suitable if space permits. Radiators painted with metallic bronzing paints such as aluminium have less efficiency than radiators painted with flat paints or with enamels. See separate Folder for Concealed Radiator Transmissions. TRANSMISSION TABLE (Wrought Iron Pipes) UNCOVERED B.Th.U.s per lineal foot per hour Size of Pipe J. 3 I l l ' 2 2 3 4 5 6 80 42 53 60 73 82 97 115 140 174 212 250 TEMPERATURE DIFFERENCE (Deg. Fahr.) Water Steam 85 90 95 100 105 110 150 155 160 45 48 51 56 59 63 95 98 103 56 60 64 70 . 75 80 118 123 130 64 70 74 80 85 90 135 140 147 78 85 90 98 103 110 168 175 180 87 96 102 110 116 124 185 195 202 103 113 120 130 137 145 220 228 238 122 135 142 155 165 175 260 272 283 150 165 175 188 200 212 320 330 345 185 203 215 232 245 262 395 410 426 225 247 265 282 300 318 480 500 522 270 290 310 330 350 375 560 585 610 The above is for single pipes freely exposed. For three or more pipes installed one above the other in the form of a pipe coil, reduce by 10% for pipes under l in. size, and by 20% for pipes l in. and over. COVERED PIPES The transmission from covered pipes varies according to the efficiency and thickness of the non-conducting material employed. For pipes covered with 5 in. hair felt allow one half, I in. asbestos one-third, and 1^ in. magnesia one-quarter of the above values. AIR CHANGE A natural interchange of air or air leakage is continuously taking place from any enclosed space which is being heated, exclusive of air provided by ventilating schemes, mechanical or natural. This leakage is dependent on the character of the construction, the number of windows and doors, etc., and is a purely arbitrary figure. The following, however, are useful examples assuming buildings of normal good con struction and with natural ventilation only:-- Very large Halls and Churches ...................................... Large Halls, and smaller Churches, etc................................. Rooms with one exposed wall with one window ... ,, ,, two ,, walls with one window ..' ,, ,, one exposed wall with two windows ... ,, ,, two ,, walls with two windows ... ,, ,, three ,, walls with two windows ... Entrance Halls, Corridors .................................................. Schools and Hospital Wards with natural cross ventilation Air Change, i per hour 3. *4 2 2 3 One cubic foot of air heated one degree Fahr. at 62 requires 0.02 B.Th.U. per hour. 203 r 7 CRANE EXPOSURE AND WIND VELOCITY The aspect of the exposed walls of a heated building has an important bearing on the calculation of heat losses. The following minimum quantities should be added to the heat losses for the under mentioned exposures:-- North, North-east and North-west ........................... 10% East .......................................................................... 5% For isolated buildings in very exposed positions as at the top of a hill or on the coast line, add a further 5% to all heat losses. BUILDINGS NOT CONTINUOUSLY HEATED An apparatus of larger capacity is required when a building is only intermittently heated, than when continuously heated. For buildings heated during the day only, add 10-15%, and for buildings such as Lecture Halls or Churches, where the apparatus is not in use daily, 25-30% should be added to the capacity of radiators, boiler and mains. TEMPERATURES FOR VARIOUS ROOMS The following temperatures are frequently specified for the warming of various rooms:-- GARAGES (not workshops) ............... ... 45 deg. F. CHURCHES, LECTURE HALLS ............... ... 58 > BEDROOMS, private houses ............... ... 55 FACTORIES (save as under) ............... ... 55 > FACTORIES, female workers, seated ... BEDROOMS, hotels and flats ............... ... 60 ... 60 tt it CORRIDORS AND ENTRANCE HALLS ... THEATRES, CINEMAS AND CONCERT HALLS ... 60 ... 60 it it OFFICES .................................................. ... 62-65 it LIVING-ROOMS AND DAY NURSERIES ... 65 it HOSPITALS AND SCHOOLROOMS ... ... 65 tt OPERATING THEATRES .......................... DRYING ROOMS ...................................... ... 70-73 it ... 80 tt WARMING HIGH ROOMS For rooms above 12 ft. in height some authorities state a percentage should be added to the heating surface of the radiators as follows:-- ft. per cent. , ft. per cent. 14 ... ............... 4 25 ... ............... 20 16 ... ............... 7 30 ... ............... 25 18 ... ............... 10 35 ... ............... 30 20 ... ............... 15 40 ... ............... 33 204 CRANE EXPANSION TANKS The water content of a hot water heating system expands one twenty-third when fully heated, and the tank should have ample capacity to accommodate this expansion without overflowing. The inlet to the ball valve should be fixed so that when cold there is only two inches of water in the bottom of the tank. To determine the approximate tank capacity for estimating purposes, allow two gallons for every 100 square feet of radiating surface in the installation (radiators and circulating pipes) with a minimum of 10 gallons. Thus, a system with a boiler of 1,100 square feet rating requires a tank of 22 gallons capacity. See page 5 for water content of " Pall Mall " Radiators. EXPANSION OF WROUGHT IRON Temperature when Pipe Fitted Deg. F. 32 40 50 64 Length of Pipe when Fitted ft. 100 100 100 100 120 deg. in. 0-73 0-64 0-56 0-45 Expansion of Pipe when heated to 160 deg. in. 215 deg. in. 250 deg. in. 0-90 0-96 0-88 0-77 1-45 1-41 1-33 1-20 1-72 1-69 1-61 1-50 265 deg. in. t -87 1-80 1-71 1-63 Nominal Bore in. 3 x 3 1 4 4 Outside Diameter in. -4 22 1-4 in 1-4 in WROUGHT IRON PIPE APPROXIMATE MEASUREMENTS Contents Approx. Weight Nominal Outside Bore Diameter Contents Gallons per ft. Pounds - per ft. in. in. Gallons per ft. 0047 0084 019 0339 053 0763 58 81 1-16 1-6 2-36 3-00 2 2* 3 4 5 6 2# 1356 3 212 3* 3053 4* 5426 5* 848 4 1-221 Approx. Weight Pounds per ft. 4-1 5-334 6-326 8-282 10-17 12-57 Nominal Size of Pipe Inches 3, 1 4 4 2 PIPE FACTORS For converting lineal feet to square feet Wrought Iron Copper for converting square feet to lineal feet Wrought Iron Copper Nominal Size of Pipe Inches For converting lineal ft. to square ft. Wrought Iron For converting square ft. to lineal ft. Wrought Iron 21 13 4-76 7-64 2i 75 1-32 28 20 3-63 5-09 3 92 1-09 33 26 2-90 3-83 3* 1-05 95 43 33 2-30 3-05 4 1-19 84 50 39 2-01 2-55 5 1-46 68 62 -- 1-61 -- 6 1-75 57 Multiply quantities by constants shown in respective columns 205 CHIMNEY FLUES The importance of having a chimney which fulfills the requisite requirements is almost as great as the choice of the boiler. These requirements are:-- (a) Sufficient height to permit the chimney to exert enough "puli'' by reason of the difference in temperature between the gases in the chimney and the cold air outside. (b) Sufficient cross sectional area to enable the chimney to easily carry away the products of combustion. (c) A complete avoidance of air leakages or openings which would reduce the temperature of the gases in the chimney and thus diminish the draught, The height of the chimney is of necessity generally determined by the height of the building but it should never be less than 20 ft. and 25ft. is preferably the minimum. The precise cross sectional area cannot be determined with exactness owing to such indeterminate factors as the condition of the inner surfaces of the flue, barometric changes, fluctuating flue gas analysis, etc., but the undermentioned table gives capacities of chimney flues for various heights and sizes which will in general be found satisfactory under ordinary working conditions. ~ APPROXIMATE CHIMNEY' CAPACITIES FOR HEATING BOILERS IN THOUSANDS OF BRITISH THERMAL UNITS PER HOUR Size of Flue Inches Area Square Inches 20 -- 9x 9 14x 9 I8x 9 I4x 14 18x 14 I8x 18 22 x 18 24 x 18 36 45 50 87 81 160 126 -- 162 -- 196 -- 252 -- 324 -- 396 ____ 432 -- HEIGHT IN FEET ABOVE GRATE 25 30 40 50 60 70 80 100 55 62 80 90 105 115 ___ 100 115 140 165 185 200 220 -- 185 210 250 290 310 330 350 400 275 300 420 460 500 560 615 765 375 425 525 615 700 775 825 950 -- 500 675 775 875 975 1075 1250 -- ____ 900 1025 1075 1275 1400 1600 -- ____ 1250 1350 1475 1600 1750 2000 --____ ____ 1550 1700 1850 1975 2100 2600 -- -- 1750 1900 2100 2400 2750 For Circular Brick Flues with fire tile lining increase capacities by 10 per cent. For exposed iron flues decrease capacity by 10 per cent. Minimum size of exposed iron flue, 6 ins. diameter. CRA N E CHIMNEY FLUES--continued The top of the flue should not be unduly restricted by using a pot having a s diameter appreciably less than the width of the flue. Also the top should pot be overshadowed by a higher building or roof line adjacent, or down > draughts will result when wind is in a certain direction. 1 In the case of boilers standing in range or fireplace opening, the lower end of the flue should be tighly sealed off by means of a sheet iron covering-in / plate. CARE OF HEATING BOILERS IN I SUMMER MONTHS* ' It is common when inspecting a heating boiler during the summer months to find the boiler left exactly as it was when the fire went out for the last time, with the remains of the fuel on the grate and ashes beneath in the ashpit. There is nothing more conducive to shortening the life of a Cast Iron Sectional Boiler than leaving it in this condition, for during the summer . months, especially when the boiler is fixed in a basement heating chamber, condensation collects on the cold cast iron surfaces and mixing with the sulphur in the flue dust and ashes forms a corrosive acid, which eats into the boiler metal. To prolong the life of the boiler, and to maintain its efficiency when the next : heating season arrives the following steps are necessary:-- ; I. Remove all ashes, clinker, unburned fuel, etc., from the grate and ashes from the ashpit. 2. Have the chimney swept and the cast iron smoke pipe connecting the boiler to the chimney scraped and swept free of soot and flue ; dust. 3. Scrape and brush clean all firebox and flue surfaces of the boiler. (In Crane Boilers all heating surfaces are very accessible.) 4. Leave the smokehood damper and the whole of the ashpit door wide open, so that a current of air passes through the boiler, and thus minimizes the possibility of condensation being deposited on the iron. 5. Clean off and oil all movable parts, such as hinges, dampers, etc. Do not permit the heating system to be emptied down unless this is neces sary for making alterations. This is of special importance in hard water districts. * Extract from Crane pamphlet supplied free of charge to Heating Engineer customers with their name overprinted. 207 CRANE s a 1 Ft. 2 3 4 5 6 7 8 9 10 II 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 60 70 80 90 100 43" 0 275 0-5 0-8 II 1-4 1-6 1-9 2-2 2-5 2-7 3-0 3-3 3-6 3-8 4-1 4-4 4-7 5-0 5-2 5-5 5-8 6-0 6-3 6-6 6-9 7- 1 7-4 7-7 8-0 8-3 8-5 8-8 91 9-4 9-6 9-9 10-2 10-5 10-7 II-0 11-3 11-5 11-8 12-1 12-4 12-7 12-9 13-2 13-5 13-8 16-5 19-3 22-0 24-8 27-5 \" 0-346 0-7 1-0 1-4 1-7 2-1 2-4 2-8 3-1 3-5 3-8 4-1 4-5 4-8 5-2 5-5 5-9 6-2 6-6 6-9 7-3 7-6 8-0 8-3 8-6 9-0 9-4 9-7 10-0 10-4 10-7 III 11-4 11-7 12-1 12-5 12-8 13-2 13-5 13-8 14-2 14-5 14-9 15-2 15-6 15-9 16-3 16-6 17-0 17-3 20-8 24-2 27-7 31-1 34-6 IV 0-434 0-9 1-3 1-7 2-2 2-6 3-0 3-5 3-9 4-3 4-8 5-2 5-6 6-1 6-5 6-9 7-4 7-8 8-3 8-7 9-1 9-6 10-0 10-4 10-911-3 11-7 12-2 12-6 13-0 13-5 13-9 14-3 14-7 15-2 15-6 16-1 16-5 16-9 17-4 17-8 18-2 18-7 19-1 19-5 20-0 20-4 20-8 21-3 21-7 26-0 30-4 34-7 39-1 43-4 SIZE OF PIPE IS INCHES ir V 2i' 3" 3r 4" 0-494 0-622 0-753 0-916 1-046 1-175 1-0 1-5 2-0 2-4 2-9 3-4 3-9 4-4 4-9 5-4 5-9 6-4 6-9 7-4 7-9 8-4 8-9 9-4 9-9 10-4 10-9 11-3 11-9 12-3 12-8 13-3 13-8 14-3 14-8 15-3 15-8 16-3 16-8 17-3 17-8 18-3 18-8 19-3 19-8 20-3 20-8 21-3 21-8 22-2 22-7 23-2 23-7 24-2 24-7 29-6 34-6 39-5 44-5 49-4 1-2 1-9 2-5 3-1 3-7 4-4 5-0 5-6 6-2 6-8 7-5 8-1 8-7 9-3 10-0 10-6 11-2 11-8 12-5 13-0 13-7 14-3 14-9 15-6 16-2 16-8 17-4 18-0 18-7 19-3 19-9 20-5 21-2 21-8 22-4 23-0 23-7 24-3 24-9 25-5 26-1 26-8 27-4 28-0 28-6 29-2 29-9 30-5 31-1 37-3 43-5 49-8 56-0 62-2 1-5 2-3 3-0 3-8 4-5 5-3 6-0 6-8 7-5 8-3 9-0 9-8 10-5 11-3 12-0 12-8 13-5 14-3 15-0 15-8 16-5 17-3 18-0 18-8 19-5 20-3 21-0 21-8 22-5 23-3 24-1 24-8 25-6 26-3 27-0 27-8 28-5 29-3 30-1 30-8 31-6 32-3 33-1 33-8 34-6 35-3 36-1 36-8 37-6 45-2 52-7 60-2 67-8 75-3 1-8 2-7 3-6 4-6 5-5 6-4 7-3 8-2 9-1 10-0 11 -0 11-9 12-8 13-7 14-6 15-5 16-5 17-4 18-3 19-2 20-2 21-1 22-0 22-9 23-8 24-7 25-6 26-6 27-5 28-4 29-3 30-2 31-1 32-0 33-0 33-9 34-8 35-7 36-6 37-6 38-5 39-4 40-3 41-2 42-2 43-0 43-9 44-8 45-8 55-0 64-1 73-3 82-4 91-6 2-0 3-1 4-2 5-2 6-3 7-3 8-4 9-4 10-5 11-5 12-5 13-6 14-6 15-7 16-7 17-8 18-8 19-9 20-9 21-9 23-0 24-0 25-1 26-1 27-2 28-2 29-3 30-3 31-4 32-4 33-4 34-5 35-5 36-6 37-6 38-7 39-7 40-8 41-8 42-9 43-9 45-0 46-0 47-0 48-1 49-1 50-2 51-2 52-3 62-8 73-2 83-7 94-1 104-6 2-4 3-5 4-7 5-8 7-0 8-2 9-4 10-6 11-8 12-9 14-1 15-3 16-5 17-6 18-8 20-0 21-2 22-3 23-5 24-7 25-9 27-0 28-2 29-3 30-5 31 -7 32-9 34-1 35-3 36-4 37-6 38-8 40-0 41-1 42-3 43-5 44*6 45-8 47-0 48-2 49-4 50-6 51-7 52-9 54-0 55-2 56-4 57-6 58-7 70-5 82-3 94-0 105-7 117-5 ------- 5" ~&r~ 1-455 ^739 2*9 4-4 5-8 7-3 8-7 10-2 11-6 13-1 14-6 16-0 17-4 18-9 20-3 21-8 23-2 24-7 26-2 27-6 29-1 30-5 32-0 33-5 34-9 36-3 37-8 39-3 40-7 42-2 43-6 45-1 46-5 48-0 49-5 50-9 52-4 53-8 55-2 56-7 58-2 59-6 61-1 62-5 64-0 65-5 67-0 68-4 69-8 71-2 72-7 87-3 101-9 116-4 131-0 145-5 5-2 7-0 8-7 10-5 12-1 13-9 15-7 17-4 10.1 20-9 22-6 24-3 26-| 27-8 29-6 31-3 33-1 34-8 36-5 38-3 40-6 41*7 43-5 45-2 47-0 48-7 50-4 52-1 53-9 55-6 57-4 59-1 60-8 62-6 64-3 66-0 67-8 69-5 71-3 73-0 74-8 76-5 78-2 80-0 81-7 83-5 85-1 87-0 104-3 121-7 139-1 156-5 173-9 208 CRANE COMPARATIVE THERMOMETER SCALES Degrees Fahr, 0 +i 2 3 4 5 6 7 8 9 10 ii 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 Degrees Centigrade --17 *78 17*23 16*67 16-11 15*56 15-00 14*45 13-90 13*34 12-78 12*23 11*67 ii-ii 10*56 10-00 9*45 8-89 8*34 7-78 7-23 6*67 6-11 5*56 5*00 4*45 3*90 3*34 2*78 2*23 1-67 Ml 0*56 0*00 +0-56 Ml 1*67 2-23 2*78 3*34 3*90 4-45 5*00 5-56 6-11 6*67 7-23 7-78 8-34 8*89 9*45 10-00 10-56 II-II 11*67 Degrees Fahr, 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 Degrees Centigrade 12-23 12-78 13-34 13*90 14*45 15-00 15*56 16*11 16-67 17*23 17-78 18*34 18*89 19*45 20*00 20*56 21*11 21*67 . 22*23 22*78 23*34 23*90 24*45 25*00 25*56 26*12 26-67 27-23 27*78 28-34 28*89 29*45 30*00 30*55 31-11 31*67 32*22 32*78 33*33 33*89 34-45 35*00 35*56 36*11 36*67 37*23 37-78 38-34 38*90 39-45 40*00 40-56 41-11 41-67 Degrees Fahr, 108 109 no in 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 1.30 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 Degrees Centigrade 42-32 42-78 43*34 43-90 44-45 45*00 45*56 46-11 46-67 47-23 47-78 48*34 48-90 49*45 50*00 50*56 51-11 51*67 52*23 52*78 53*34 53*90 54*45 55*00 55*56 56-11 56*67 57-23 57-78 58*34 58*90 59*45 60*00 60*56 61-11 61*67 62*23 62*78 63*34 63*90 64-45 65*00 65*56 66*11 66*67 67*23 67*78 68*34 68-90 69*45 70*00 70-56 71*11 71-67 Degrees Fahr, 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 Degrees Centigrade 72*23 72*78 73*34 73-90 74-45 75*00 75*56 76-11 76*67 77-23 77-78 78*34 .78*90 79*45 80*00 80*56 81-11 81*67 82-23 82-78 83*34 83*90 84*45 85*00 85*56 86*11 86*67 87-23 87-78 88*34 88*90 89-45 90*00 90-56 91*11 91*67 92*23 92*78 93*34 93*90 94*45 95*00 95-56 96*11 96-27 97*23 97*78 98-34 98-90 99-45 100*00 O J _ Jv^' CRANE DIMENSIONS OF BRITISH STANDARD PIPE FLANGES REPORT No. 10, PART 1--1928 TABLE B FOR WATER PRESSURES SO TO 130 POUNDS PER SQUARE INCH (SUPERSEDING TABLE I OF REPORT No. 10--1914) TABLE C FOR WATER PRESSURES 130 TO 175 POUNDS PER SQUARE INCH (SUPERSEDING TABLE I OF REPORT No. 10--1904) Tables B and C 1 2 3 4/5 6 (a) 6 (b) Thickness of flange (f) Nominal Pipe Size in. 21 4 1 1* 1* 2 2* 3 3* 4 *4 5 6 7 8 9 10 *11 12 *13 14 15 16 *17 18 *19 20 21 22 *23 24 Diam. of Flange in. 3* 4 4* 4* 5* 6 6* 7* 8 8* 9 10 II 12 13* 14* 16 17 18 19* 20* 21* 22* 24 25* 26* 27* 29 30 31 32* Diam. of Bolt Circle in. 2f 2* 3* $76 3| 4* 5 5* 6* 7 7* 8* 9* 10* II* 12* 14 15 16 17* 18* 19* 20* 21* 23 24 25* 26* 27* 28* 29* Number and Dia. of Bolts in. L 4 -L 4- 4* 4* 4a 41 41 4 4# 8I 8I 81 8I 81 8t 8* 8* 12 * 12 * 12 * 12 * 12 12 * 12 I 12 i 16 I >6 I 16 1 16 1 16 1 Cast Iron Table Bc in. in. 2 2T 58. f 5____ 4146- 3 11 3 16 4 a 44 3, 7 37 48 J1_63 5 ZZ Z z 18 7 S | i1 i1 i i* i l1 *8 1 14- li 1* i* 1* i* 1* i* 1* i* 1# '! 1* 1* it 18 1* [1/ 1* If If >1 Cast Steel and Bronze Table 6c in. in. 33 8 'S Z 1 1 2 9 16 5 1 ZZ 11 16 ttt 3. 3 4 24 i Z 8 1 1 1 1* I* 8 3 'S j. fL 9 16 1% 9 JL 4 6 44- . a4 43 7 8 S' z I 1 1 h 1* h* 14 u la If 18 /mn or Steel (Stamped or forged) Table 6C in. in. 3 'i TS _126_ _L I6 16 _5_ 16 3 3 3 23 | % 1\ 6 2 7 71 ? 2 z1 * ? 2 1 2 1a aa a 8 5 a 8 S3 a 53 84 a7 48 3z 48 4 If 11 7 28 1 I I8 1* 1 * The Association recommends that the use of these sizes be discontinued. THICKNESSES . The thicknesses given In this Table include a raised face of not more than -jV inch high If such be used. BOLT HOLES For i-inch and |-inch bolts the diameters of the holes to be tV inch larger than the diameters of the bolts, and for larger sizes of bolts inch. Bolt holes to be drilled off centre lines. 210 Fo CRANE DIMENSIONS OF BRITISH STANDARD PIPE FLANGES REPORT No. 10, PART 2--1926 TABLE D FOR STEAM PRESSURES UP TO 50 POUNDS PER SQUARE INCH (SUPERSEDING TABLE I OF REPORT No. 10--1904) 1 23 A 5 Nominal Pipe Size Diameter of Flange Diameter of Bolt Circle Number of Bolts Diameter of Bolts in. 1 2 3. 1 1* 1* 2 2-L 3 3* 4 *4* 5 6 7 S 9 10 *11 12 *13 14 15 16 *17 18 *19 20 21 *22 *23 24 in. 3* 4 4* 4 5* 6 6* 7* 8 8* 9 10 II 12 13* 14* 16 17 18 19* 20* 211 22* 24 25* 26* 27# 29 30 31 32* in. 2| 2* 3* 3* 4* 5 5* 6* 7 7* 8* 9* 10* 11* 12* 14 15 16 17* 18* 19* 20* 211 23 24 25* 26* 27* 28* 29* 4 4 4 4 4 4 4 4 4 4 8 8 8 8 8 8 8 8 12 12 12 12 12 12 12 12 16 16 16 16 16 in. i 5 5, 5 I f 1 5 S f 1 s. 3. 3, 3. 3 z 7 s 7_ z 7 2 7. s 7 i 1 1 1 6 (o) 6 (b) 6(e) Thickness of Flange Cast in. Cast Steel and Bronze in Iron or Steel (stamped or forged), screwed or riveted on with boss, or welded on with fillet in. 1 2 2c 3 i6 e tV i 5 3 8 16 85 2 4 81 4 3 4 43 _11966_ 16 T6 4 6 38 247.. 6 8 7 1*i6 8 78 16 I 6 36 2T i 43 4 i i 3. i* i li i* 7 87 i* 1 i* 1 i* 1 i3 If | 3 If If u J2L .5 5 5 f 24. 43 4 3, i 1 7_ 1* 1* 1* 1* 1* Id_ 1 1 If If If 1-ii If * The Association recommends that the use of these sizes be discontinued. THICKNESSES , The thicknesses given in this Table include a raised face of not more than -jV inch high if such be used. BOLT HOLES For -inch and |-inch bolts the diameters of the holes to be -jV inch larger than the diameters of the bolts and for larger sizes of bolts inch. Bolt holes to be drilled off centre lines. CRANE PIPE SIZES LOW PRESSURE HOT WATER GRAVITY SYSTEMS In a natural circulation low pressure hot water system, pipes should be sized to carry sufficient quantities of water to maintain the Radiators at approximately an even temperature throughout. There are three factors which control the sizes, viz., (1) temperature difference between flow and return, (2) the heights of the Radiators above the Boiler, and (3) the length of the circulation, referred to below as "travel." Temperature difference may vary between 25 for one pipe ring main to 50 for overhead two-pipe drop systems. Generally 30 F. is most suitable for one-pipe systems, and 40 F. for two-pipe; the chart opposite is based on these temperature differences. The heights of the Radiators above the Boiler affect the pipe sizing for the reason that the circulating pressure in a low pressure hot water system is in direct proportion to the height of the vertical flow and return columns. It is not necessary to size a system on the height of the most unfavourably situated Radiator as this ignores the assistance given to the principal circuits by Radiators which are favourably placed. Accordingly, the mean effective height of each circuit should be the mean common denominator of each Radiator height, multiplied by the B.Th.U.s of each, as illustrated in example under. The travel represents the distance which the water has to flow from the Boiler to the Radiator and back, and thus is the total length of flow and return in a circuit plus a margin for the additional friction caused by Tees, Bends, Offsets, etc. Illustrating the application of height and travel factors to a simple example, consider a circuit with one radiator of 2,500 B.Th.U.s 20 ft. above boiler, another 3,000 B.Th.U.s 11 ft. above, and a third 3,500 B.Th.U.s 1 ft above. The total actual length of this circulation is, say, 95 ft., to which adding 10 per cent, for fittings gives 105 ft. travel. Radiator 2,500 x 20 ft. = 50,000 86,500 4- 9,000 ,, 3,000 X 11 ft. = 33,000 gives mean effective , ,, 3,500 x I ft. = 3,500 height 9-5 ft. Total 9,000 B.Th.U.s 86,500 9-5 Height -- travel is = -09 From the chart it will be seen that for a load of 9,000 B.Th.U.s, ignoring pipe losses, a 1-in. pipe will be required. The above example, of course, does not take into account heat lost from :irculating pipes which should actually be added to the radiators to obtain :he circuit load, afterwards checking the pipe size from the chart. 212 PIPE SIZES to C4 o 30 > z m a ; a1 CRANE PIPE SIZES, LOW PRESSURE STEAM TABLE 7. Pipe Sizes for Two-Pipe, Gravity, Low Pressure Steam, where Equivalent Length of Run from Boiler or Source of Supply to Farthest Radiator does not exceed 200 ft. Capacity in sq. ft. of Equivalent Radiation Based on Total Pressure Drop of I oz. per 100 ft. i I Pipe Sizes Inches Supply Main Dripped and Branches to Risers Dripped Steam and Condensate Flowing in same Direction Supply Risers Up-Feed Branches to Supply Risers and Radiators Not Dripped Return Risers Wet Return Main Dry Return Main Radiator Supply Valve Radiator Return Valve A B C D* E F G H i ~~ i_ 30 _ 122 _ _ 30 122 1 56 56 26 320 700 320 56 190 n 122 122 58 670 1200 670 122 386 i* 190 190 95 1058 1900 1058 190 2 386 386 195 2300 4000 2300 386 _ _'2 635 635 395 3800 6700 3300 _ _,3 1163 H29 700 7000 10,700 7000 3 1737 1548 1150 10,000 -- 10,000 -- -- 4 5 2457 4546 2_042 1700 3150 _ _ _ __ _ _ _. 6 7462 -- -- -- --* -- -- -- COPYRIGHT 1927 S American Society of Heating and Ventilating Engineers \ Reprinted by Special ' ' \ Heating and Piping Contractors' National Association, J Permission * Radiator branches more than 8 ft. in length should be one size larger than shown in Col. D. NOTE I.--These tables apply where pipes are properly reamed. No allowances for defective material or workmanship have been made. NOTE 2.--Capacities based on lb. condensation per square foot per hour equivalent radiation and actual diameter of standard pipe. ' NOTE 3.--Extra length to be added to straight run of pipe for various fittings and valves to determine equivalent length (see Table 4). NOTE 4.-- Where it is necessary to drip a supply main, supply riser or branch to a supply riser, same should be dripped separately into a wet return or through an adequate seal into a dry return. Never drip a supply pipe into a dry return except through an adequate seal. NOTE 5.--Pitch of mains should not be less than in. in 10 ft.*, on horizontal branches to radiators and risers at least in. in 10 ft. c c t TABLE 4. Length in Feet of Pipe to be Added to Actual Length of Run to Obtain Equivalent Length. Size of Pipe 2" 2}" 3" 3i" 4" 5" 6" 7" 8" r 10" 12" 14" St'd, Elbow 5 7 10 12 14 18 22 26 31 35 39 47 53 | Side Outlet Tee Gate Valve Length in feet to be Added in Run 16 2 20 3 26 3 31 4 35 5 44 7 50 9 55 10 63 12 " 69 13 76 15 90 18 105 20 Globe Valve 18 25 33 39 45 57 70 82 94 105 118 140 160 Angle Valve 9 12 16 19 22 28 32 37 42 47 52 63 72 c 214 CRANE TABLE 13. Pipe Sizes for Vacuum Pump Systems, where Equivalent Length of Run from Boiler or Source of Supply to Farthest Radiator Exceeds 200 ft. Capacity in Sq. Ft. of Equivalent Radiation Equivalent length of Pipe from Boiler to Farthest Radiator, Including Main and Riser. (See Note 4.) Maximum Capacities Inches Steam and Condensate flowing in same direction* Based on 4 or. Total Pressure Drop** 100 Ft. 200 Ft. 300 Ft. 400 Ft. 500 Ft. 600 Ft. Supply Up-Feed Branches to Supply Risers and Not Dripped A B cDE F G H i* 3 a i III 79 65 56 49 46 56 la 245 173 141 122 no 100 122 1* 380 269 220 190 165 155 190 2 771 546 446 386 345 315 386 26 58 95 195 2* 1270 898 734 635 568 518 3 2326 1645 1342 1163 1040 948 3* 3474 2457 2006 1737 1552 1419 4 4914 3475 2828 2457 2196 2011 5 9092 6429 5250 4546 4062 3712 6 14,924 10,553 8618 7462 6669 6094 8 31,066 21,967 17,935 15,533 13,880 12,682 10 56,689 40,085 32,730 28,345 25,334 23,144 12 90,985 64,336 52,530 45,492 40,660 37,145 635 1129 1548 2042 -- _ -- -- -- 395 700 1150 1700 3150 _ ------- -- TABLE 13--continued Capacity in Sq. Ft. of Equivalent Radiation. . Different makes of supply and return valves, steam traps and other specialties vary as to capacity, therefore use size as recommended for any particular make. Vertical connection to be of same size as valve and trap used. Return horizontal runout to be no less than in. Pipe Size Inches Riser Main JK 100 Ft. L 200 Ft. M Return Mains and Risers 300 Ft. N 400 Ft. 0 500 Ft. p 600 Ft. Q 3 800 568 462 400 358 326 21 1400 994 810 700 626 570 i la 2400 1704 1387 1200 1073 976 ii li 3800 2696 2195 1900 1698 1547 2 8000 5680 4622 4000 3575 3256 2 2* 13,400 9510 7745 6700 5990 5453 2i 3 21,400 15,190 12,360 10,700 9565 8710 3 3 32,000 22,710 18,490 16,000 14,300 13,020 3* 4 44,000 31,220 25,430 22,000 19,660 17,910 COPYRIGHT Notes and Explanation of Tables on following page. * Sped., Person CRANE TABLE 13--continued Radiator branches more than 8 ft. in length should be one size larger than shown in Column I **ltis not generally considered good practice to greatly exceed I or. drop in pressure in each lOOft.equival length of run nor to exceed I lb. total pressure drop in any system. * ent NOTE I.--These tables apply where pipes are properly reamed. No allowances for defective material workmanship have been made. 0r NOTE 2.--Capacities based on lb. condensation per square foot equivalent radiation and actual diameter of standard pipe. NOTE 3.--Extra length to be added to straight run of pipe for various fittings and valves to determine equivalent length. (See Table 4.) NOTE 4.--Mains are to be proportioned according to the equivalent length of run from the boiler or source of supply to the farthest radiators supplied by the main. Determine equivalent length of run, then use figures in corresponding Column (6 to G) for sizing the entire run. Supply risers are to be proportioned according to the equivalent length of run from the boiler or source of supply to the farthest radiator on each riser. Determine the distance to the farthest radiator, then use figures in that corresponding Column (6 to G) for sizing each riser; provided the amount of radiation for that riser does not exceed amounts shown in Column H. Where riser capacities are found to be in excess of amounts shown in Column H, step up to necessary size indicated in that column. NOTE 5.--Return mains and risers are to be proportioned according to the equivalent distance in feet from farthest radiator to the vacuum pump; using capacities in that corresponding Column (L to Q) for sizing entire return riser (Column J) and return main (Column K). NOTE 6.--Where it is necessary to drip a supply main, supply riser or branch to a supply riser, same should be dripped separately through a steam trap into vacuum return. Never drip a supply riser into a vacuum return except through a steam trap. NOTE 7.--Pitch of mains should be not less than in. in 10 ft.; on horizontal branches to radiators at least 4 in. in 10 ft. RADIATOR CONNECTIONS Two-Pipe Gravity and Vacuum Line Heating Systems Square Feet Direct Radiation 1- 25 26- 80 81-100 101-140 141-180 181-300 301-450 451-700 Inlet Valve `Inches i ? 2. 3. 1 1 1* 1* 2 SUPPLY Vertical Pipe ' to Inlet Valve Inches i 3 4 3 1 1 1* 1* 2 Horizontal Runout to Riser or Springpiece to Main from a First Floor Radiator Inches 3 i i* i* i* i* 2 2i RETURN Stub to Trap and Size of Trap i J i t 2 1 i 3 4 Horizontal Runout to Riser or First Floor Radiator 1 2. 3, 3 4 3. 2. 3 2 4 Table reproduced by the courtesy of the C. A. Dunham Company. Use pipes one size larger for horizontal connections over 8 ft. long. Grade with a fail not less than in. per foot. 216 STEAM--USEFUL FIGURES CRANE Vacuum, inches of Mercury 23-81 21-78 19-74 17-70 15-67 13-63 11-60 9-56 7-52 5-49 3-45 1-42 Abso/ute Pressure Lbs. per sq. inch 3-0 4-0 5-0 6-0 7-0 8-0 9-0 10-0 11-0 12-0 13-0 14-0 Temperature Fahrenheit 141-52 153-01 162-28 170-06 176-85 182-86 188-27 193-22 197-95 201-96 205-87 209-55 Total Heat above 32 f. In the Water Heat Units per lb. In the Steam Heat Units per lb. 109-4 120-9 130-1 137-9 144-7 150-8 156-2 161-1 165-7 169-9 173-8 177-5 1121 -6 1126-5 1130-5 1133-7 1136-5 1139-0 II4I-I 1143-1 1144-9 1146-5 1148-0 1149-4 Latent Heat Heat Units per lb. 1012-3 1005-7 1000-3 995-2 991-8 988-2 985-0 982-0 979-2 976-6 974-2 971-9 Lbs. Gauge 0-0 0-3 1-3 2-3 3-3 4-3 5-3 6-3 7-3 8-3 9-3 10-3 15-3 20-3 25-3 30-3 40-3 50-3 60-3 70-3 80-3 91-3 101-3 125-3 151-3 175-3 200-3 225-3 255-3 14-7 15-0 16-0 17-0 18-0 19-0 20-0 21-0 22-0 23-0 24-0 25-0 30-0 35-0 40-0 45-0 55-0 65-0 75-0 85-0 95-0 106-0 116-0 140-0 166-0 190-0 215-0 240-0 270-0 212-0 213-0 216-3 219-4 222-4 225-2 228-0 230-6 233-1 235-5 237-8 240-1 250-3 259-3 267-3 274-5 287-1 298-0 307-6 316-3 324-1 332-0 338-7 353-1 366-5 377-6 388-0 397-4 407-9 180-0 181-0 184-4 187-5 190-5 193-4 196-1 198-8 201-3 203-8 206-1 208-4 218-8 227-9 236-1 243-4 256-3 267-5 277-4 286-3 294-5 302-7 309-6 324-6 338-7 350-4 361-4 371-4 382-5 1150-4 1150-7 1152-0 1153-1 1154-2 1155-2 1156-2 1157-1 1158-0 1158-8 1159-6 1160-4 1163-9 1166-9 1169-4 1171-6 1175-4 1178-5 II8I-I 1188-4 1185-4 1187-4 1189-0 1192-2 1195-1 1197-3 1199-3 1200-9 1202-6 970-4 969-7 967-6 965-6 963-7 961-8 960-0 958-3 956-7 955-1 . 953-5 ' 952-0 945-1 938-9 933-3 928-2 919-0 911-0 903-7 897-1 890-9 884-7 879-3 867-7 856-4 846-9 837-9 829-5 820-1 VOLUME One cu. in. of water evaporated at atmospheric pressure is converted into approximately 1 cu. ft. of steam. One pound of steam occupies 26-79 cu. ft. and the density is 0-373 lbs. at atmospheric pressure. 217 J CRANE AREAS AND CIRCUMFERENCES OF CIRCLES Dia. Circum. Area Dia. Circum. Area Dia. ----------------- Circum. Area 1 16 1963 00307 2* 7-2649 4-2 6f 19-63 30-67 1 8 3927 01227 2f 7-4613 4-4302 6f 20-42 33-18 3 i6 589 02761 2* 7-6576 4-6664 6f 21-20 35-78 1 4 7854 04909 2* 7-854 4-9087 7 21-99 38-48 S 16 9817 0767 2* 8-0503 5-1573 7f 22-77 41-28 3 8 11781 -1104 2f 8-2467 5-4119 7f 23-56 44-17 7 T6 1-3744 1503 2ff 8-443 5-6723 7f 24-34 47-17 1 2 1-5708 1963 2f 8-6394 5-9395 8 25-13 50-26 J1 L6 I-7771 i8 1-9635 11 16 2-1598 3 4 2-3562 13 16 2-5525 7 8 2-7489 15 16 2-9452 1 3-1416 2485 3068 3712 4417 5185 6013 6903 7854 2ff 8-8357 2f 9-0321 o4x1s6. 9-2284 3 9-4248 3f 9-8175 3f 10-21 3f 10-602 3f 10-995 6-2126 6-4918 6-7772 7-0686 7-6699 8-2957 8-9462 9-6211 8f 8f 8f 9 9f 9f 9f I0f 25-91 26-70 27-49 28-27 29-06 29-84 30-63 31-41 53-45 56-74 60-13 63-62 67-20 70-88 74-66 78-54 Iflg. 3-3379 8866 3f 11-388 10-32 101 32-98 86-59 1* 3-5343 994 3f 11-781 11-044 II 34-56 95-08 1* 3-7306 1-1075 3f 12-173 11-793 Mf 36-13 103-87 li 3-927 1-2271 4 12-566 12-566 12 37-69 113-09 1-ft 4-1233 1-353 4f 12-959 13-364 I2f 39-27 122-71 If 4-3197 1-4848 H 13-351 14-186 13 40-84 132-73 1* 4-516 1-6229 4f 13-744 15-033 I3f 42-41 143-13 If 4-7124 I-7671 H 14-137 15-904 14 43-98 153-93 1* 4-9087 1-9175 14-529 16-8 14f 45-55 165-13 If 5-1051 2-0739 4f 14-922 17-72 15 47-12 176-71 Iff 5-3014 2-2365 H 15-315 18-665 I5f 48-69 188-69 If 5-4978 2-4052 5 15-708 19-635 16 50-26 201-06 Iff 5-6941 2-58 5f 16-1 20-629 I6f 51-83 213-82 If 5-8905 2-7611 5f 16-493 21-647 17 53-40 226-98 (1 J1J6. 6-0868 2-9483 5f 16-886 22-69 I7f 54-97 240-52 2 6-2832 3-1416 5f 17-278 23-758 18 56-54 254-47 2Vr 6-4795 3-3410 5f 17-671 24-85 '8f 58-12 268-80 2f 6-6759 3-5465 5f 18-064 25-967 19 59-69 283-53 2* 6-8722 3-7584 5f 18-457 27-108 I9f 61-26 298-64 2* 7.0686 3-976 6 18-85 28-27 20 62-83 314-16 USEFUL CONVERSIONS CRANE CONVERSION OF AREAS Sq. in. to sq. cm. Sq. cm. to sq. in. Sq. ft. to sq. m. Sq. m. to sq. ft. Sq. yd. to sq. m. Sq. m, to sq. yd. Acres Hectares Sq. mi. to to to hectares acres sq. km. Sq. km. to sq. mi. 1. 6-452 0-1550 0-0929 10-76 0-8361 1-196 0-4047 2-471 2-590 0-3861 CONVERSION OF VOLUMES OR CUBIC MEASURE Cu. in. to cu. cm. Cu. cm. to cu. in. Cu. ft. to cu. m. Cu. m. to cu. ft. Cu. yd. to cu. m. 1. 16-39 0-06102 0-02832 35-31 0-7646 Cu. m. to cu. yd. 1-308 Gallons to cu. ft. 0-1337 Cu. ft. to gallons 7-481 CONVERSION OF VOLUMES OR CAPACITIES Liquid ounces to cu. cm. Cu. cm. to liquid ounces Pints to. litres Litres to pints Quarts to litres Litres to quarts Gallons to litres Litres to gallons Bushels to hecto litres Hecto litres to bushels 1. 29-57 0-03381 0-4732 2-113 0-9464 1-057 3-785 0-2642 0-3524 2-838 CONVERSION OF MASSES Grains to grams Grams to grains Ounces (avoir.) to grams Grams to ounces (avoir.) Pounds (avoir.) to kilo grams Kilo grams to pounds Short Metric Long tons tons tons (2000 lb.) (1000kg.) (2240/6,) to to to metric short metric tons tons tons Metric tons to long 1. 0-06480 15-43 28-35 0-03527 0-4536 2-205 0-907 1-102 1-016 0-984 CONVERSION OF PRESSURES Pounds per sq. in. to kilograms per sq. cm. Kilograms per sq. cm. to pounds per sq. in. Atmospheres to pounds per sq. in. 1. 0-0703 14-22 14-70 Pounds per sq. in. to atmospheres 0-0680 Atmospheres to kilograms per sq. cm. 1-033 Kilograms per sq. cm. to atmospheres 0-9678 CONVERSION OF ENERGY, WORK, HEAT Ft.-lb. to kilogrammetres Kilogrammetres to ft.-lb. Ft.-lb. to B.Th.U.s B.Th.U.s to ft.-lb. Kilogram- metres to large calories Large calories to kilogram- metres Joules to small calories Small calories to joules 1. 0-1383 7-233 0-001286 777-5 0-002344 426-6 0-2390 4-183 CONVERSION OF POWER Horsepower to kilowatts Kilowatts to horsepower 1. 0-7457 1-341 Metric horsepower to kilowatts 0-7354 Kilowatts to metric horsepower 1-360 Horsepower to metric horsepower 1-014 Metric horsepower to horsepower 0-9863 CRANE USEFUL DATA WATER One imperial gallon = 277*274 cubic inches = 16 cubic foot = 10 lbs. = I *2 U.S,A. gallons = 4*537 i- One cubic inch of water = *03607 lb. = *003607 imperial gallon. ,tpe$. One cubic foot of water = 6*23 imperial gallons = 7*48 U.S.A. gallons = *028 ton = 28*375 litres. One pound of water = 27*72 cubic inches -- * 10 imperial gallon = *4573 kilogramme. * One ton of water -- 35*9 cubic feet = 224 imperial gallons -- I cubic metre approximate. One litre of water = *22 imperial gallon = 61 cubic inches = *0353 cubic foot = I kilogramme, PRESSURE One pound per square inch = 2*31 feet of water = 27*71 inches of water -- 703*03 kilogrammes per m2 One atmosphere = 14*7 lbs. per square inch = 2116*3 lbs. per square foot = 33*947 feet of water. ` One kilogramme per square metre = *00142 lb. per square inch. HEAT One B.Th.U. is the amount of heat required to raise I lb. of water I deg. Fahr. I B.Th.U. equals 0*252 Calorie = *294 watt hour = 777*5 foot pounds. One Calorie (Kcal) or Great Calorie is the amount of heat required to raise one kilogramme of water I degree Centrigrade. I Calorie equals 3*97 B.Th.U.s. One Petit Calorie is the amount of heat required to raise one gramme of water I degree Centigrade. One Calorie per m2 One B.Th.U. per square foot One Calorie per m2 per degree difference Cent. One B.Th.U. per square foot per degree Fahr. One B.Th.U. per lb. One Calorie per kilogramme *3687 B.Th.U. per square foot 2*712 Calories per m8 *2048 B.Th.U. per square foot per degree diff. Fahr 4*882 Calories per m8 degrees difference Cent. * *556 Calorie per kilogramme 1*8 B.Th.U.'s per lb. LENGTH One foot One metre One inch One centimetre 12 inches 39*37 inches = 0-0833 foot = 0*3937 inch 0*3048 metre = 3*281 feet 0*02454 metre -- 0*0328 foot AREA One square foot One square metre One square inch One square centimetre = -- = = 144 square inches 1550 square inches 0*0069 square foot 0* 1550 square inch = 0*0929 square metre = (0*76 square feet -- 6*452 square centimetres VOLUME One cubic foot One cubic metre One cubic inch One cubic centimetre z= 1728 cubic inches -- 61030 cubic inches =s 16*39 cubic cm. = 0*0610 cubic inch = 0*0283 cubic metre = 35*32 cubic feet ss 0*0164 litre WEIGHT One kilogramme One pound One cwt. One ton 2-2 lbs. 16 o?s. = 112 lbs. = 20 cwt. _ 0*454 kilogramme t= 50*80 kilogrammes = 10-16 kilogrammes ELECTRICAL One kilowatt = 1000 watts = 737*3 foot pounds per sec. = I *34 horse power. One B.O.T.U. (unit) = I kw. hour = 3412 B.Th.U.s One unit of electricity will raise 5 galls, of water 68*24 F. in one hour. POWER One horse power = 550 foot pounds per sec. = 33,000 foot pounds per minute. = 746 watts = I *014 metric horse power. 220 FIGURE NUMBER INDEX CRANE No. Page No. Page No. Page No. Page No. Page No. Page No. Page 101 102 103 105 no Ml 112 115 121 150 150 ISO 150 150 150 150 151 151 233 234 236 237 238 241 242 246 247 160 160 160 160 100 161 161 161 161 581 582 585 588 589 591 592 800 801 174 174 174 174 174 173 173 25 25 887 895 896 897 899 900 905 906 907 112 A66 134 D236 120 H 89 126 113 A68 134 D237 120 HIOI 114 113 A70 134 D238 117 HI 12 127 113 A72 136 D239 117 HI2I 127 113 A74 136 D240 118 HI5I 127 113 A76 136 D24I 113/6 HI52 127 175 A79 136 D242 118 H2II 107 175 AI42 139 D243 113/7 H2I3 107 175 AI5I 139 D260 118 H226 100 122 126 131 132 133 134 136 137 138 140 141 142 144 145 146 147 148 149 ISO 151 152 155 161 163 167 171 175 176 177 178 179 180 181 (85 187 188 191 192 193 194 195 196 197 199 201 211 212 213 214 215 216 221 222 229 151 151 151 151 151 151 152 152 152 152 152 152 152 152 153 153 153 153 153 153 153 153 154 154 154 154 154 154 154 154 155 155 155 155 155 155 156 156 156 156 156 156 157 157 157 158 158 158 158 158 158 159 159 159 249 250 256 257 259 260 261 262 264 265 271 272 276 277 279 280 289 298 299 300 501 502 503 506 507 508 511 512 513 514 515 516 517 520 521 522 523 524 526 527 528 529 530 531 532 551 552 553 560 561 566 573 574 577 161 802 iii 803 162 804 162 805 162 806 162 807 162 808 162 809 162 810 162 811 163 812 163 813 163 814 163 820 163 825 163 826 164 827 164 830 164 840 164 842 166 843 166 844 166 845 167 846 167 847 167 848 168 849 168 850 168 851 168 852 168 853 168 854 169 855 169 856 169 857 169 858 169 859 169 860 169 861 170 862 170 865 170 866 170 868 170 869 170 870 171 871 171 872 171 873 171 874 171 875 171 876 172 877 172 878 172 879 25 908 25 909 13 910 (3 911 25 912 25 913 13 914 22 925 22 926 22 935 22 936 22 937 22 938 25 939 23 940 23 941 23 942 32 943 189 944 98 970 98 971 98 972 98 974 98 975 98 976 98 978 98 980 98 982 98 983 98 984 99 985 99 986 99 987 99 988 99 989 99 995 99 996 99 A 1 99 A 3 99 A 6 106 All 106 AI2 107 A30 107 A32 108 A35 108 A5I 109 A53 109 A54 110 A55 no A56 in A57 hi A59 hi A6I no A63 175 C 1 148 D300 123 H23I 100 175 C 2 148 D30I 123 H234 101 175 C 3 148. D320 123 H242 100 175 C 4 148 D32I 123 H245 101 175 C 5 148 D342 104 H311 128 175 C 6 148 D343 104 H3I2 128 175 C 7 148 D344 104 H3I3 128 114 C 8 148 D345 104 T 5 176 114 C 9 148 E50 114 T 6 1 /6 140 CIO 149 E53 114 T15 177 140 CM 149 E55 114 TI6 1 // 141 C12 149 E56 114 T40 178/9 141 CI3 149 E57 114 T4I 178/9 141 CI4 149 E60 114 T42 179 142 CIS 149 E66 114 T45 179 143 CI6 149 E70 115 T50 180 144 CI7 149 E75 IIS T5I 180 145 C18 149 E78 115 T60 181 146 CI9 149 E80 115 T70 181 81 C20 149 E170 102 T84 182 81 C2I 149 EI7I 102 T85 182 81 C22 149 EI72 102 T86 182 81 C23 148 EI73 102 T110 184 81 C97 190 E176 102 Till 184 81 CIOI 191 EI77 102 TII2 184 81 cin 191 EI78 102 T1I3 184 81 D 1 122 E186 102 TI20 184 81 D 5 122 EI87 102 TI2I 184 81 D 7 122 El 88 102 T122 184 81 D 8 122 E200 103 T125 185 81 Dll 122 E201 103 TI26 185 81 D76 121 E204 102 . TI36 185 81 D78 118 E2I0 103 ' TI55 186 81 DI38 123 E2I5 103 TI57 186 81 DI39 123 E290 190 TI59 186 104 DI40 123 E292 190 T16I 187 104 DI41 123 F5I 165 DI5I 120 F52 130 TI65 188 130 TI67 188 165 D163 121 F62 131 TI69 188 165 DI64 121 F65 131 TI71 188 165 DI69 120 F8I 131 TI73 188 165 D201 113/6 F89 131 TI87 188 165 D202 113/6 F35I 129 TI89 188 165 D203 116 F352 129 TI9I 188 165 D2II 117 F440 129 T193 189 132 D2I2 117 F442 129 T200 187 132 D213 117 H SO 125 T204 187 132 D2I4 117 H 51 125 T209 187 132 D22I 113/6 H 52 125 T83I 32 132 D222 113/6 H 70 124 T832 32 132 D223 116 H 71 124 T833 32 132 D23I 118 H 74 124 T834 32 132 D232 118 H 77 124 T85I 189 134 D233 118 H 88 126 T852 189 230 159 578 172 886 112 Old No. D305 D360 EI41 E146 EI48 EI5I New No. D342 D343 H226 H23I H234 H242 FIGURE NUMBERS REVISED Old No. New No. Old No. New No. EI55 E295 E300 F40 F42 H245 C10I cm F440 F442 H20 H22 H35/7 H90 H95 H89 H88 H70/I H121 H122 Old No. K5 K6 K50 K55 K6I New No. HI5I H152 H311 H3I2 H3I3 INDEX Page Air Cocks .......................... ... 114 ,, Valves .......................... 114, 115 Airlet Plugs.......................... ... 114 Altitude Gauges .............. Asbestos Sheet Packing ... ... 103 ... 190 Automatic Air Valves ... ,, Boiler Feeders ... Baffle Plates.......................... ... 114 ... 107 ... 15 Boiler Cement ,, Fittings ,, Headers ,, Mountings ,, Ratings ............... ............... .............. ............... ............... ... 82 98, 99 ... 81 100--107 34, 83 ,, Regulators ............... 106, 107 ,, Smoke Pipes ... 96,97 ,, Stokers, Automatic ... 64 ,, Stoking Tools ... ... 105 ,, Tappings, Whitehall 78, 79, 81 ,, Tools.......................... ... 82 ,, Wrenches .............. ... 189 Boilers-- Carlton .......................... 35--50 Circular Domestic ... 92, 93 Domestic.......................... 83--95 Gas Fired.......................... 50, 51 Heating .......................... ... 34 Ipswich .......................... 84--89 Oil Burning ............... 65--73 Open Fire Domestic ... 84--89 Pulverized Fuel .............. 64, 77 Regent .......................... 90, 91 Sectional Domestic ... 94, 95 Steam .......................... 75, 76 Whitehall.......................... 52--81 Bolts and Nuts ............... ... 190 "Boss-white" ............... ... 191 Bower-Barffed Boilers ... 84--94 British Standard Flanges ... 210, 211 Cast Iron Flanged Fittings ... 132--138 ,, ,, ,, Unions ... ... 139 ,, ,, Flanges............... ... 139 ,, ,, Screwed Fittings ... 165 Ceiling Plates ............... 168, 174 Check Valves, Cast Iron ... ... 129 ,, ,, Gun Metal ... ... 123 Cisterns ...............141, 144 145, 147 Cocks, Air.......................... ... 114 Cocks, Draw-off .............. ,, Gland .............. Page ... 104 104. 123 Plug.......................... Concealed Valves .............. 104,123 ... 118 Conditions of Sale.............. 192, 193 Corner Valves "Crabenite" .............. .............. 117 ... 190 Cylinders, Storage ... 140--143, 147 Damper Regulators.............. 106, 107 Data...................................... 194--220 Deadweight Safety Valves ... 100, 101 Draw-off Cocks ............... ... 104 Elbows, Union ............... 113, 116 Expansion Joints ............... ... 128 ,, Tanks ............... ... 141 Flanges, Threaded............... ... 99 Flanged Fittings ............... ,, Unions ............... Flanges, Cast Iron............... 132--138 ... 139 ... 139 ,', Floor, Towel Airer Floor Plates ... ... ... Flue Brushes.......................... Gas Pokers.......................... Gate Valves, Cast Iron ... ... 113 ... 174 ... 105 ... 104 130, 131 ,, ,, Gun Metal ... 120, 121 ,, ,, M.W.B. ... ... 121 ,, ,, Radiator ... 116, 118 Gland Cocks.......................... 104, 123 G.L.C. Safety Valves ... ... 100 Globe Valves, Cast Iron ... ... 129 ,, ,, Gun Metal ... ... 122 Graphite .......................... ... 191 Gratings and Frames ... ... 175 Hack saws .......................... ... 189 Hall's Pipe Thimbles ... ... 174 Headers .......................... ... 81 Hoffman Air Valves.............. ... 115 ,, Modulating Valves ... 118 ,, Traps ............... ... 124 Indirect Cylinders............... ... 140 Jackets, Insulated and Non-insulated 55 Joint Rings, Mudhole ... ... 82 Key Spanners ............... ... 189 Keys, Lockshield ............... ... 118 Malleable Iron Fittings ... 150--164 Mercury Wells ............... ... 102 M.W.B. Valves ............... ... 121 222 CRANE INDEX--continued Page Mica Panels for Boilers ... ... 82 Modulating Valves.............. ... 118 Oil Burning Boilers............... 65--73 Painting Radiators.............. ... 33 Pipe Brackets and Hangers 166--173 ,, Compound .............. ... 191 ,, Cutters.......................... ... 184 ,, Fittings, C.l. Flanged ... 132--138 ,,,, >, Screwed ... 165 ,, ,, Malleable Iron 150--164 ,, Flanges.......................... ... 139 ,, Hangers and Brackets 166--173 ,, Saddles ............... ... 159 ,, Strainers ............... ... 127 ,, Unions.......................... 160--164 ,, Vices .......................... 186--188 ,, Wrenches ............... ... 185 ,, Wrought ............... ... 148 Plug Cocks.............. ... 104, 123 Plugs, Airlet ............... ... 114 ,, Draw off ............... ... 104 Pokers, Gas.......................... ... 104 Pop Safety Valves ............... ... 107 Radiator Air Valve Keys ... ... 114 ,, ,, Valves ... ... 114 ,, Angle Valves ... ... 116 ,, Baffle Plates ... ... 15 ,, Brackets ... 13, 22, 23, 25 ,, Bushes ............... ... 32 ,, Corner Valves ... ... 117 ,, Deflecting Shields ... 14 ,, Dimensions ... ... 5 ,, End Sections ... ... 33 ,, Gaskets ............... ... 32 ,, Gate Valves ... 116, 118 ,, High Legs ... ... 32 ,, Invisible Shields ... ... 14 ,, Nipples ............... ... 32 ,, Painting ............... ... 33 ,, Pedestals............... ... 32 ,, Plugs ............... ... 32 ,, Regulating Valves ... 117 ,, Shields ............... 14, 15 ,, Sundries............... ... 32 ,, Tappings............... ... 33 ,, Testing ............... ... 33 ,, Towel Airers ... ... 112 Page Radiator Traps .............. ... 124 ,, Valves ............... 116--119 m Washers............... ... 32 ,, Wrenches............... ... 32 Radiators, Concealed ... 26--30 ,, Copper .............. ... 31 ,, Four Column ... ... 8,9 ,, Hospital ... 16--21 ,, Long ... ... 33 ,, Six Column ... 10, II ,, Two Column ... ... 6,7 ,, Wall ............... ... 24 ,, Window............... ... 12 Reamers .......................... ... 187 Reducing Valves .............. ... 127 Registers, Louvred.............. ... 175 Regulating Quadrants ... ... 175 ,, Valves............... ... 117 Roller Brackets .............. 172, 173 Rubber Rings for Mudholes ... 82 Safety Valves ............. 100,101,107 Shovels .......................... ... 105 Smoke Bends ............... ... 97 ,, Cowls .............. ... 96 ,, Elbows .............. ... 97 ,, Pipes .............. ... 96 Spring Relief Valves ... ... 100 ,, Safety Valves ... ... 100 Steam Traps .............. 124--126 Stocks and Dies .............. 176--183 Stoker Fired Boilers ... 64--73 Stoking Tools ............... ... 105 ,, Tool Racks ... ... 105 Storage Cylinders ... 140--143,147 Straight Unions ............... 113, 117 Strainers .......................... ... 127 Tank Cutters ............... ... 187 Tanks .......................... 141--147 Taylor's Ring's ............... ... 190 Thermometers ............... 102, 103 ,, Circular Dial ... 103 ,, H.M.O.W. ... 102 ,, "Therindex" ... 102 Throttle Valves .............. ... 121 Tongue Crosses .............. ... 154 ,, Tees.......................... ... 154 Tools ............... 82, 176--189 223 CRANE IN DEX--continued Page Towel Airers ... ... 108--112 ,, ,, Sundries .............. 113 Traps, Radiator ... .............. 124 ,, Steam ... ... 125, 126 Tubes, Wrought ... .............. 148 Union Elbows ... ... 113,116 ,, Wrenches ... .............. 187 Unions, Malleable Iron ... 160--164 ,, Straight ... ... 113, 117 Vacuum Steam Air Valves .............. 115 Valve Keys................ .............. 114 Valves, Air.............. ... 114,115 ,, Angle ... .............. 116 ,, Check ... ... 123, 129 ,, Concealed ... .............. 118 ,, Corner ... .............. 117 ,, Dimensions .............. 119 ,, Easyclean ... ... 116--118 ,, Gate 116, 118, 120, 121, 130, 131 ,, Globe ... ... 122, 129 Valves, Iron Body .............. ,, Modulating.............. ,, Pop Safety.............. ,, Pressure Reducing ,, Radiator .............. ,, Reducing .............. ,, Regulating.............. ,, Relief .............. Page 129--131 118 ... 107 ... 127 116--119 ... 127 ... 117 ... 100 ,, Safety ... 100, 101, 107 ,, Swing Check ... ,, Throttle .............. ,, Towel Airer ... Ventilators.......................... Vices...................................... Wall Gratings and Frames ,, Stays, Towel Airer ... Water Capacities, Radiators 123, 129 ... 121 ... 113 -- 175 186--188 ... 175 ... 113 ... 5 Wells, Mercury .............. ... 102 Welldeck Steam Traps ... ... 126 Wrought Tubes and Fittings 148, 149 DATA Page Air Changes ... .............. 203 Area of Circles ... .............. 218 Boilers, care of ... .............. 207 B.S. Pipe Flanges ... ... 210,211 B.Th.U.s per hour ... .............. 213 Building Temperatures .............. 204 Care of Boilers ... .............. 207 Ceiling Heat Losses ... 199,200 Chimney Flues ... .............. 206 Circle Areas and Circumferences... 218 Conversion Tables ... 219,220 Covered Pipe Transmissions ... 203 Doors, Heat Losses .............. 201 Electrical .............. .............. 220 Expansion of Pipes .............. 205 Expansion Tanks ... .............. 205 Exposure Losses ... .............. 204 Factory Roof Heat Losses ... 201 Flange Dimensions ... 210,211 Floor Heat Losses ... ... 198, 199 Glass Heat Losses ... .............. 201 Heat.......................... .............. 220 Heat Loss Co-efficients ... 195--201 INDEX Page High Rooms, Warming ... . ... 204 Metrical Equivalents ... 219,220 Pipe Dimensions .............. ... 205 ,, Expansion of.............. ... 205 ,, Factors .............. 205 ,, Flanges .............. 210,211 ,, Sizing, Hot Water ... ... 212 ,, ,, Steam.............. ... 214 ,, ,, Vacuum Pumps 215, 216 ,, Surfaces .............. 205, 208 ,, Transmissions.............. ... 203 Power .......................... ... 220 Pressure ... .............. ... 220 Radiator Connections, Steam ... 216 ,, Transmissions ... ... 202 Steam Constants .............. ... 217 Temperatures .............. ... 204 Thermometer Scales ... ... 209 Transmission Tables ... 202, 203 Wall Heat Losses .............. 195--197 Water .......................... ... 220 Wind Velocity Losses ... ... 204 Wrought Iron Pipe Dimensions ... 205 224 Printed in England by Unwin Brothers Limited W. . i-