Document mBMj49myNGgda3XJYr0Lm6RzB
rest conditions.
3 This may explain in part why no significant
difference exists between half facepiece negative pressure and
pressure-demand respirators.
PROCEDURE
Prior to testing, each person was trained in the
selection and fit testing of respirators using the National
\Paint and Coatings Association Training Program^4
Each was
then fit tested using the saccharin fit test^. Respirators
selected for use by participants are listed above and in
Table I.
Two individuals were also trained in use of a
pressure-demand self-contained breathing apparatus. Fit
testing was not done, as it i6 not required for pressure-demand
equipment in the ANSI Z88.2 (19B0) standard. During sample collection, each participant was
observed continually to ensure that the sample train remained
intact and did not interfere with the respirator se>l on the
face, and to note occurances which might have affected
respirator performance, such as movement of the respirator on
the face. The participants were very busy with their work
activities and soon ignored the presence of the researchers.
AIR SAMPLING AND ANALYSIS
To determine the workplace protection factors,
concurrent samples were taken from inside the respirator
(in-mask) at nose level and outside the respirator at the
DUP 0907357