Document mBKXqZ2B0qopGB82Ja4ZdLwGQ

Boilers Molby Boiler Company 41 East 42nd Street Incorporated NEW YORK New Molby Magazine--Feed, Downdraft, Smokeless Boilers with the new adjustable side grate--for steam, vapor and hot water. tvitht ^lOLBY The new `Molby* will heat home--large apartment house --or commercial building-- having a good chimney, just as successfully and just as easily with this low-priced small coal as ordinary boilers burning the expensive sizes. New adjustable side grate permits regulation of fire to suit kind of coal used. Low draft resistance. The new ` Molby* is easy to operate, is self feeding, and gives a steady, even heat over long periods with low-priced No. 1 Buckwheat Anthracite, as well as larger sizes. Also burns sized free-burning bituminous with proper chimney draft. Also coke. Magazines need re-filling only once every 12 hours. Cast iron sectional construction throughout. Ratings are based on the assumption that a good grade of No. 1 Buckwheat Anthracite is to be used and that the chimney is of such area, height and tight ness as to produce the required draft; also that the boiler, mains and connections shall be covered with an insulating material. These ratings, under the same conditions, may be used for sized soft coal, of the free-burning and non-caking variety. Should larger sizes of good grades of Anthracite be used, a given boiler--other conditions being the same--would burn with equal efficiency. 20 per cent more coal. Thus, when such larger sizes are regularly used, the ratings shown are increased 20 per cent. The new `Molby* boiler is built throughout in accordance with the codes of the American Society of Mechanical Engineers and the American Society of Heating and Venti lating Engineers. 1 Water Line Returns Steam Rating Height Outlets Chimney Flue Approximate Shipping Weight Returns | Water Rating Number SIZES, CAPACITIES, DIMENSIONS AND PRICES OF NEW MOLBY BOILER STEAM STEAM AND WATER WATER Size-- nches Steam Cipher List Price ji 45 & -C to Vc -1 V O E CO Number Water Cipher List Price 26" Series S- 4026 S- 5026 S- 6026 S- 7026 S- 8026 Adageo Addleo Adnuto Adzo Adelo 43 2-3 43 2*3 43 2-3 43 2-3 43 2-3 500 $2801 54 675 340 54 850 400 54 1025 460 54 1200 . 520 j 54 41 41 41 41 41 35% 10 2-3 8x12 1890 W- 4026 Domo 2-3 850 $270 42 10 2-3 8x12 2230 W- 5026 Doseo 2-3 1125 330 48% to 2-3 8x12 2580 W- 6023 Doffo 2-3 1400 390 55 to 2-3 12x12 2950 W- 7025 Dovco 2-3 1700 450 61% 10 2-3 12x12 3300 W- 8026 Uocko 2-3 2000 510 31" Series S- 4031 S- 5031 S- 6031 S- 7031 S- 8031 S- 9031 S-I003I Bugo Buffo Bullo Burto Buibo tJuoyo Bungo 54 2-3 1000 4701 62% 61 54 2-3 1350 580 m 61 54 2-3 1700 667 j 62>A 61 54 2-3 2050 814 62% 61 54 2-3 2400 904 62% 61 34 2-4 2750 984 62% 61 54 2-4 3100 1064 62% 61 37% 14 2-4 8x12 3320 W- 4031 Edamo 2-4 1650 470 44 14 2-4 12x12 3820 W- 5031 Edgeo 2-4 2250 580 50% 14 2-4 12x12 4290 W- 6031 Edito 2-4 2850 667 56% 14 2-4 12x16 4690 W- 7031 Edicto 2-4 3425 814 63% 14 2-4 12x16 5100 W- 8031 hdeno 2-4 4000 904 69% 14 3-4 16x16 5510 W- 9031 Educeo 3-4 4575 984 75% 14 3-4 16x16 5930 W-10031 Eduxo 3-4 5150 1064 47" Series S' 5047 S- 6047 S- 7047 S- 8047 S- 9047 S-10047 S-t 1047 S-12047 S-13047 Calxo Callo Caro Carpo Casco Cadio Cabo Uando Camo 61 2-4 2550 960 80 61 2-4 3200 1120 80 61 2-4 3850 1280 80 61 2-4 4500 1446 80 61 2-4 5150 1600 80 61 3-4 5800 1760 80 61 3-4 6450 1940 80 61 3-4 7100 7100 80 61 3-4 7750 2260 80 75% 50% 14 2-4 12x16 5990 W- 5047 Fluxo 2-4 4250 960 25% 59 14 2-4 16x16 7150 W- 6047 Fledo 2-4 5325 1120 75% 67% 16 3-4 16x16 8310 W- 7047 Klipo 3-4 6400 1280 75% 76 16 3-4 16x20 9500 W- 8047 Flowo 3-4 7500 1440 75% 84% 18 3-4 16x20 10650 W- 9047 Flungo 3-4 8575 1600 75% 93 18 4-4 20x20 11640 W-10047 Flusho 3-5 9650 1760 73'A 101% 18 4-4 20x20 13000 W-II047 1* Unto 3-5 10725 1940 75% no 18 4-4 20x24 14150 W-12047 Flato 3-5 11800 2100 75% IIS'/, 18 4-4 20*24 15320 W-13047 Meigo 3-5 12925 2260 Note.--In ordering 26-in. boilers state whether you wish same fitted up with right hand or left hand end to the chimney. Length includes Smoke.Box. Equipment.--Each steam boiler is equipped with a full set steam trimmings (26 in. series. 1 pressure regulator; 31 in. and 47 in. series, 2 pressur regulators). Water boilers are furnished with two water temperature regulators; except 26 in. series which are equipped with one. A complete set of firing and cleaning tools, together with an instruction card for its operation, accompanies each steam and water boiler. 216 Boilers OilCitt BoilerWorks Oil Cit y/ New York, 501 Fifth Ave. Chicago. 1224 Marquette Bldg. Los Angeles. 404 Union Bank Bldg. Pittsburgh, 1116 House Bldg. Baltimore, Dukehart Bldg., McComas and Race Sts. Detroit, 242 W. Larned St. Kansas City, 410 E. 43rd St. Minneapolis, Metropolitan Life Bldg. Philadelphia, Room 1043 Rea! Estate Trust Bldg. Atlanta, 50 S. Forsyth St. Boston, 66 Broadway, Cambridge. Toronto, Ont., 45 Jarvis St. "0*7 City" Direct Draft Boiler "0*7 City" Smokeless Boiler "OIL CITY" low pressure boilers are offered to the trade as the last word in "Heating Economy" comprising in one unit all the elements of a modern plant for steam or hot water heating, especially adapted for Schools, Office Buildings, Hotels, Churches, Club Houses, Hospitals or for any purpose where the service of a universally recognized fire box boiler of high merit is desired. "OIL CITY" boilers are designed and constructed to meet all requirements of modern engineering as formulated by the American Society of Mechanical Engineers, the boiler laws of the various states and cities, and are backed by thirty-five years of successful practical experience. Description--"OIL CITY" boilers are built in smokeless and straight draft types for portable and brick settings, self con tained with all steel construction thor oughly braced, stayed, inspected, and tested for 15 lb. working pressure. These boilers have large fire boxes thereby insuring ample combustion space in which heat-giving gases and air freely mix before entering tubes. The arrangement of tubes in relation to shell allows free circulation of water at all times, together with large steam space, insuring dry steam and steady water level. All parts of the boiler are made ac cessible for cleaning by the use of man holes,* handholes, and wash-out plugs. Ratings--Ratings are very conservative, only such parts of the boiler coming in actual contact with passage of the hot gases, and lying below the zone of normal water level being considered as heating surface. Equipment--Equipment with all boilers includes, in addition to complete set of shaking grates, all the necessary castings, safety valves, steam gauge, water column, etc., required for a complete installation. In General--In addition to the foregoing, the object of the OIL CITY BOILER WORKS is to furnish a boiler that has embodied in it the best feature of modern construction and free from the recognized faults. Every "OIL CITY" boiler bears the official stamp, or symbol of the A. S. M. E. Boiler Code, indicating the pressure at which the boiler may be worked. At a small increase in cost "OIL CITY " boilers are furnished, braced and stayed, for a safe working pressure of 100 lb. Complete- specifications, measurements and weights shown in Catalog H-9. SPECIFICATIONS AND GENERAL DIMENSIONS ON NEXT PAGE. 217