Document mB7M1RVq2ZGqjGp1va5v89BvQ
>218
Controls and Itutna^jl
CX/ft/L/ Instruments... for quick, precise
measurement of air flow--surface temperatures
6fa,VEL0METER'
a sensitive instrument that will give instant direct reading of air flow in feet per minute. Readings as low as 20 f.p.m. can be made. The triple graduated scale on the dial can register a high of up to 24,000 f.pjn. or 20 in. of water.
The Velometer will give direct reading of static pressure in ducts, plenum chambers, or pipes. Register pressure loss-across heater and filters, friction loss at ells and deflectors. Many government and munic ipal jobs require Velometer checking before acceptance.
For general use in air conditioning, warm air heating and ventilating, Velometer set No. 3G is recommended. Consists of the Velometer with rugged reinforced carrying case, supply jets, return jets, static pressure jet, duct jet and diffuser jet. Price f.o.b. Chicago $194.00.
For quick, simple, checking on circulation
in halflTMTing duct outlets the
seif-
tained Velometer Jr. (4' i3'11M') can
be used, where the work does not require
the use of jet attachments. Available in
three double air flow ranges, 0-200 f.p.m.
and 0-800 f.p.m., 0-400 f.p.m. and 0-1600
f.p.m., 0-500 f.p.m. and 0-2500 f.p.m. Price
f.o.b. Chicago $44.00 Bulletin 2448 gives
- completeinformationon the VelometernnH
all attachments.
mnor PYROMETER Model 2300B
Registers surface temperatures accurately and instantly by simply touch ing the thermocouple tip to any surface, or will register air temperatures at grills, inside ducts etc. with the air temperature thermocouple tip. Saves time with quick, positive readings. Can be used to set thermal expansion valve on cooling coils in less than a minute.
Balance hot water systems accurately. Test insulation and temperature of walls, floors and ceilings.
Locate hot water pipes in cement floors. Use it any place where surface temperature readings are required. Has full 6 inch mirrored scale.Temper ature range --40 F. to 200 F. Complete unit in attractive durable case. Price from $195.00 f.o.b. Chicago.
^v^PYROCON
A compact hand held pyrometer with heavy-duty shock-resistant construction and with a firm grip handle balanced for easy handling. Accurate temper ature readings are registered immediately on touching the tip to any surface. Can be used for practically the same service as the Alnor Pyrometer described above on tempera tures within the range of the instrument.
Can be furnished in eight temperature ranges, 0-300 F., 400" F., 500 F., 600 F., 800 F., 1000 F., 1200 F., 2000 F. and also
sub-zero ranges. The 0-300 F. is recom mended for general heating and venti
lating service. Price with case and shielded ther
mocouple $125.00 f.o.b. Chicago Bulletin No. 4257 gives com plete information on Pyrocon models and accessories. .
ALNOR INSTRUMENT CO-
Division of Xlllnola Tasting Laboratories, Inc.
Room 516 * 420 North LaSalle Street Chicago 10, Illinois
end Instruments
219
AMERICAN TUBE AND CONTROLS
West Warwick
Rhode Island
For Hot Water Heating Systems
O FILL-TOOL
EXTROl* diaphragm type expansion tank with automatic fill vulva for positive control of fill pres sure end system expansion. Supplied with Vi" FPT for System Connection and K" Solder. Union for Water Supply.
Write for Buffetin #!00-A.
0 AIR PURGERS
Scientifically designed to continuously eliminate air from the system. Use with Extra! and American Float Vent.
Available In sixes up to 4". Sizes up to 3" ore threaded, 4" have 125 lb. standard flange
e Write for Bulletin JJ400-E. FLOAT VENTS
Advanced design for effectively venting air from Hydronk Heating end CooGng System.
Available in two pressure ranges.
0-30 PSI
0-100 PSJ
Write for Bulletin J700-E.
BASE SUDE EXPANSION JOINTS
A Smooth sliding |ont suitable for temperatures from 40* to 240* and working pressure up to 125PSI on Hot Water end 10 PSI on low Pressure Steam Systems.
Available in -Nominal Capper Tuba sizes from Vi" to 2" and Nominal Female Pipe Sizes from V" to 2". Expansion Movement minimum of 2".
Write for Base Slide Bulletin.
0 WATER HAMMER ELIMINATORS
Hoamertrof* Shock Suppressors for eliminating water hammer in ad piping systems. Available in 3 series and 33 sizes.
Write for Bulletin #511-E.
O AX(ASME) and SX SERIES EXTROL
Pressurized diaphragm-type expansion tank for positive control of expansion. Air, Pressure and Fil ling in Commercial and Industrial Hydroaic Sys tems. Available to IS sizes to meet all requirements.
The AX Series b designed and constructed in
accordance with the requirements of the ASME Un-
fired Pressure Code, and may be stomped with the
appropriate Code Symbol.
-------
Write for liilUin #I!7-F.
For Volume Water Heating
O TANK UNITS
For Volume Water Heating and for installation in Fresh Water Storage Tanks. Constructed to ASA Flange standards and ASME Code requirements.
Available in 4 series to meet afl requirements using V* and l\i" Copper Tubing for Conventional and Cement Lined Fresh Water Storage Tanks.
Write tor Bulletin #4000-F.
! HEAT EXCHANGERS
For Heating Fresh Water Instantaneously or Heat ing Radiation Water for Hydroaic System using Steam or Hot Water as the Heating Medium.
Constructed to ASA Flange Standards ASME Code FOWHMA Standard
Available in sizes up to 20" diameter and capoble of heating 1000 gpm of fresh water.
Write for Buffefin #4D0O-F.
|