Illinois Testing Laboratories, Inc.
422 N. LaSalle Street, Chicago, Illinois
TESTING ENGINEERS AND MANUFACTURERS "Alnor" Indicating Pyrometers--Portable and Wall Type. "Alnor" Sur face Temperatures, "Alnor" Distant Reading Resistance Thermometers, "Alnor" Pyrometer Controllers, "Alnor" Velometers--Air Velocity Meters.
Instruments
Leeds & Northrup Company
General office and works: 4941 Stenton Avenue, Philadelphia, Pa.
Boston Cleveland
Hartford
Chicago Detroit
Houston
Branch Offices:
/
Los Angeles Pittsburgh
San Francisco
New York St. Louis
Tulsa
RUGGED, NULL-TYPE INSTRUMENTS THAT ARE RELIABLE
Fig. 1--Showing Tube Type Velometer with No. SSSO Angle Jet taking air velocity of grille.
Fig. --Showing Tube Type Velometer with No. 31^25
Duct Jet taking readings directly in the duct. Duct Jet furnished standard 18 in. or 36 in. long. Other
lengths available on special order.
"ALNOR" VELOMETER
The Instantaneous Direct Reading Air Velocity Meter
The Velometer is a direct reading instrument which gives accurate and instantaneous
readings of the speed of air measured in feet per minute.
The indicator or meter is housed in an attractive black Bakelite case
x 2% in. and weighs approximately 2 lb.
in. x 5% in.
The movement consists of a swinging vane to which the indicating pointer is attached,
control hair springs and a magnetic damping system. The air which enters the port or
jet of the instrument exerts an impact or pressure on the vane which causes it with the
pointer to deflect across the scale and is read directly in feet per minute velocity.
No mathematical calculations or stop watches are necessary to determine the velocity
reading as the pointer indications are a direct measurement of air speed.
While the Velometer is offered in three types, the Tube Type is by far the most popular.
This type uses attachments called jets for most of the velocity readings. The style of jet
to be used depends on the requirements or purpose for which it is used.
Ranges--Standard Range 0 to 300 fpm low scale, 0-3000 fpm high scale 0 to 2 in. static
or total pressure. Other ranges available up to 18,000 fpm velocity and 20 in. pressure.
No. 2215 Averaging Jet--This jet is offered for obtaining velocities of ordinary duct openings or grilles. With this jet, average velocity readings over a 4 in. circle can be quickly obtained.
No. 2220 and No. 2240 Jets--These jets, angle and straight, have small orifices to give spot velocities over a in. diame ter. The Velometer with these jets pro vides accurate spot velocity readings of irregular shaped or slotted openings or other small velocity streams, locates leaks in duct systems and other similar service that would be difficult by other means.
No. 2425 Duct Jets--These jets are offered for direct velocity readings in ducts. The Duct Jet is, in effect, a double jet using two tubes and two
meter fittings. With this jet, static pressure is balanced out or subtracted from total pressure and the net result or velocity pressure is read directly on the scale of the Velometer in feet per minute. Thus no calculations are neces sary. Inch marks are provided on the jet for the convenience of the user.
No. 2460 Static Pressure Jet--This jet provides direct readings of static pressures of ducts, plenum chambers or pipes in inches of water.
No. 2485 Total Pressure Jet--This jet gives direct readings of total pressure, in inches of water. Inch marks are provided on this jet to enable the user to place the jet at the desired distance in the duct.
Write for Complete Folder
1014
Model S Micromax Recorder
Records from 1 to 16 points on a single stripchart. Extremely open record. Can operate
signals. (About l/loth size) '
Model R Mieromaz Recorder
Records 1 or points on a roundchart. Has extremely readable diaL Can operate signals. (About l/16th
size)
Switchboard Indicator
Hand-operated. Can be connected through selector switches to any number of points. (About l/10th size)
Electrical Thermometers for Air Conditioning
Electrical Instruments for the Heating Plant
No method for measuring temperatures fits the specific needs of air conditioning as
does the three-lead null-type resistance thermometer method. It is independent of distance and disregards all tempera tures except those right at detector loca
tions. The detectors (resistance thermo meter bulbs called Thermohms), can be placed anywhere--in rooms, air ducts or water lines. They are connected by simple electrical wiring to instruments at a central location. Instruments may be: Micromax Recorders, Model S for up to sixteen Thermohms; Micromax Model R, for related pairs such as wet and dry bulb; indicators with switches for any number of
Thermohms; or indicating and recording combinations.
The facts needed to operate a modern heating plant so as to save fuel, to protect equipment, and to operate efficiently at varying loads are provided reliably by rugged L&N instruments. Readings can be indicated or recorded or both. Re corders can be equipped to operate signals or alarms that warn the operator of extreme conditions. In some cases the instruments control automatically.
Micromax Model S provides a per manent record of conditions at from 1 to 16 points on one wide-scale chart. Micro max Model R concentrates on conditions at one point, provides a permanent record, and has a giant indicating dial that can be read at a glance. The switchboard in
This equipment is fundamentally re liable. Instruments and Thermohms are highly responsive, yet rugged in construc tion. A complete system is easy and economical to install, regardless of dis tances. It is easy to operate and demands
minimum maintenance. Thermohms and instruments are interchangeable, and can be replaced without disturbing wiring or returning anything to the factory.
dicator provides intermittent checks on conditions at one or several points.
In the heating plant, L&N measuring, signalling or controlling equipment is used for:
Metermax Combustion Control. Furnace Pressure Control. Smoke Density Analysis.
L&N Resistance Thermometers make it possible to operate efficiently; to main tain comfort or correct process atmosphere constantly ... so that maximum return is realized on the conditioning investment. J-N-225(2)
Flue Gas Analysis (Percent COj). Flue Gas Temperatures. Steam and Water Temperatures. Boiler-Furnace Temperatures. Electrolytic Conductivity of Water.