SM-32 l#**
to ALL 'MANAGERS
SHELL OIL COMPANY
istneNcc
o*rt FEBRUARY 18, 1972
f*o* MAitAGER SAFETY HOUSTON REFINERY
subisa RESPIRATORY PROTECTION
Many types of respiratory protective devices are provided toe routine and emergency conditions throughout the refinery. Each department in the refinery has respiratory equipment available where the possibility exists for employees to be exposed to organic vapors, acid or toxic gases, dust and asphyxiants. Respira tory protection for maintenance work is available from the tool room.
In order to provide an additional training aid in the use of selfcontained breaching apparatus - Scott air-pak - an operating instruction sheet is attached. These instructions should be placed in permanent order books, training manuals, bulletin boards, or some suitable place for ready reference by all concerned.
Each type of respiratory equipment has certain advantages and dis advantages, and these must be considered in relation to such consideration as the type of gas which will be encountered, degree of concentration, length of exposure, etc. When any question exists in regard to the best type of mask for a particular job, consult your supervisor or the Safety Department.
The self-contained air mask enables the wearer to work in virtually any situation in the refinery. A special face piece is required when used under a welding hood. Fresh air masks are provided with demand-type regulators and are iden ical to those used with self-contained masks such as Scott air-pak.
A canister mask acto-as-sn air filter and purifier. The canister elemes^t contains filters and special chemicals which absorb or neutralize harm ful gases contained in the atmosphere as the wearer inhales and draws outside air through the canister.
The use of canister masks is restricted to conditions when the concen tration of gas does not exceed 2%. by volume in the atmosphere. Higher concentra tions of gases will overload the absorbing rate of the chemicals, and some of the gaa will pass on through the canister. A concentration as great as 27a is con sidered very high and will seldom be found in outdoor areas. A warning that the mask is being worn in too high a concentration will be manifest by the odor of gas coining through the mask. When any such odor is detected, or the canister begins to feel warm, the wearer should leave the gassy area ieimediately.
A canister gas mask must not be worn at any location where the per centage of air contained in the surrounding atmosphere is limited or questionable, such as an excavation which has been made to repair a gas leak or when an inert gas (nitrogen) has bean used for purging. The wearer obtains his oxygen tram the atmosphere in which he is working, and an adequate supply must be present in the atmosphere when a canister mask is used.
WV-12983
ALL MANAGERS
2
Chemical cartridge respirators are small devices that cover the mouth and nose and are equipped with a cartridge or filter which is designed to remove harmful dusts or vapors from the atmosphere. In operation they are quite similar to a canister gas mask.
Dust respirators screen out particles of dust, sand, grit, asbestos, catalyst, and powdered chemicals, such as sulfur or lime. They shall be worn in atmospheres that contain these and other materials in harmful concentrations.
General Precautions in Use of Masks
1. Before using any gas mask, be certain you understand the correct way to use it.
2. Check all fittings of gas mask apparatus to make sure they are tight.
3. Always put on a gas mask in pure air before entering a hazardous atmosphere.
4. When putting on the face piece, first place one hand on each of the bottom straps and pull at the same time; next tighten the pair of middle straps and lastly the top straps. To test for tightness of the face piece, block or squeeze the inhalation hose and inhale. If the face piece then is drawn in on the face without admitting air, the fitting is satisfactory.
5. If, while using any gas mask, the odor of gas is detected, leave the gaasy area immediately.
fiLB/rg Attachment
ASS-013884