Document m1vygkNyZko6or3xv1zDD7m4

M. H. PETR1CK CO M PAN Y insulation division TECHNICAL DATA SHEET class 13.8 p a r. r 1. DETRICK THINSULINER CEMENTS Hi tl D 'A Q'Z) Thinsuliner Cements are semi-refractory products used as an internal lining ma terial in ducts, breechings and stacks carrying heated air. These cements contain hydraulic setting binders to develop the strengths required for such applications. Furnished in dry form, Thinsuliner Cements are ready to be mixed with water at the job site. TWO TYPES For various operating conditions and installation techniques, two formulations of Thinsuliner are available. Regular Thinsuliner Cement is stronger, heavier and has higher resistance to abrasion. In contrast, Thinsuliner "SL" has better ther mal value and greater resiliency. Comparative properties of the two types are given in the table below. APPLICATION Regular Thinsuliner Cement generally is troweled 3/4" to 1" thick, over Detrick GRIPTEX Blocks previously attached to the internal surface of the breeching or stack. (Note: Using special Meehanite studs and castings to attach the block in sulation in place, this is identified as "Detrick Thinsuliner Construction", and is designed individually by Detrick's Arch and Wall Division.) Thinsuliner "SL" has proved adaptable to steel stack lining applications made on the ground, i. e. , before the stack is hoisted into position as a unit. Reinforcing steel mesh is first attached to the inside of the stack, spacing it away from the steel surface approximately one-half the total thickness of the lining. Thinsuliner "SL" is mixed with water to a stiff consistency, then slap-troweled through the reinforcing mesh and built up to total thickness. After Thinsuliner "SL" has set, the stack is rotated on the ground and successive quadrants are lined in the same manner. PHYSICAL PROPERTIES (Trowel Application) THINSULINER THINSULINER "SL" Temperature Limit Fusion Temperature Water Ratio Setting Time Coverage (Applied and Dried) Material Requirements Density (Applied and Dried) Shrinkage (Wet to Dry, By Vol.) Compressive Strength (Air Cured) Density (Fired at 1500 F) Shrinkage (Fired at 1500 F) Compressive Strength (Fired at 1500 F) Thermal Conductivity (k) @ 500 F Mean Temperature Shipping Container (Sewn Closure) 1800 F 2150 F 4 gals./50 lb. bag 4-6 hours 25 bd. ft. /100 lbs. 4 lbs. /bd. ft. 50 lbs. /cu. ft. Less than 2% 850 psi 46 lbs. /cu. ft. 2% (Linear) 325 psi 1.4 Btu 50 lb. paper bag 1800 F 2250 F 5-1/2 gals. /50 lb. bag 4-6 hours 33 bd. ft. /100 lbs. 3.3 lbs. /bd. ft. 41 lbs. /cu. ft. Less than 2% </) 260 psi 38 lbs. /cu. ft. fc 2. 3% (Linear) X 90 psi X111 oi a s 0. 95 Btu 50 lb. paper bag STORAGE - Store in a cool, dry location until ready to use. June 1, 1959 INSULATIONS FC E HEAT ENCLOSURE.