Document kzLraoaJXo8eGEgjRaO1Lekq
S.V.cS
DATE PRINTED
.CG..04
CODE KO~99~D PKG
JUN 2 1982
/'"d a t e
F2H75
LOT NUMBER*^'
H
I
STD. 'HRS.
CG CODE YC-16--B
01 YC-16--B 1 YC-16--B
Wm r.r- Cti
TIME
PQ LOT
93 93 bJKSb 93 &3UtiS'
LBS //XV /p o p
'A
v
PROCESSES
APPROVED
< ) KO-909-D <C> FOP 3/25/82
( ).
:< )
<) < )'
JOB NAME: 04KO909DMC
yc~/td
/%? /OO
\5 is
/Po
EST. WT, 5243* LBS-
&
REGJ. NO - <
J^4
NON-BLEEDING
NAME "KROLQR* ORANGE Y
USE LBS
NCODE
A C OT LBS
"BEFORE USING SV, MAKE SURE THAT N-.28-D LINE
IF ANY IS BLANKED OFF."
JfRUN- 6" (99 G> WATER IN V-211. SET AGITATOR ON J^^HIGH SPEED
H IN DRUM AND POUR IN
Du mp in a n d s t ir ,,5* me n s . RECORD: STARTJi
FIN
3~<37tr.
ADJUST TO 75* <1275 G) *NOTE: VOLUife HIGHER
48 I 32-D | 48 7iX50. IYC1 6B | * 37,$"
I zifp:!::: ,i
THAN 75" MAY CAUSE DUSTING IN EXHAUST HOOD. WITH AGITATOR ON LOW SPEED PUMP V-211 THRU
HOMOG AT 2800-32PSI INTO V-208 WHEN V-211 MTY,WASH COLOR THRU HOMOG WITH MIN
F HOT WATER AT 2800-320 PSI INTO V-208 ECORD : V-208 VOL- X5___' & ADJUST TO 54 " <189G) INSPECT HOMOG STRAINER & CLEAN IF NECESSARY
349 4,
384
RUN ?" (514 G) WATER INTO V-2SS/ START
AGITATOR & INSTALL TEMP CHART
L0*T PUMP V-208 THRU HOMOG AT 480-52O PSI INTOJL
I RECORD.: .. TIME START
TOTAL MINUTES ' JE&3T
| NOTE: IF HOMOG' PRESSURE FALLS BELOW 480 PSI, ixS'-WAY VALVE'WILL RECIRCULATE SLURRY TO V-208
1 jr \ WHEN V-208 MT, RUN IN 5" <24 G) WATER & PUMP .THRU HOMOG AT 4800-5200 PSI INTO SV -r
II, WHJ.LE HOMOG, RUN 6* <284 G) WATER INTO V-349.
|1 N 1O0O* WATER INTO V-384 & HEAT TO 1i0-120*F
II. ftEIGH INTO V-384 4, PUMP TO V-349'
'1
10004 WATER INTO V-384 4. PUMP TO V-349
.____ V-349 TO 19* <899 G> 4t STIR 15 MIN
, RECORD DENSITY : /52_G/ML < 1.091 -1.094)
-Tx 1 I
*. I
2500 | 32-D
2500
HEN S-11 HOMO~COMPLETE, ADJ SV TO 6"(384G> RECORD: PH jML & ADJ TO 11.1-11.3 USING N-7-D
DILUTED TO 5% <10 PARTS WATER TO 1 PART N-7-D) ,.ASSUME 50%
SIPHON N-7-D INTO SV & RECORD: PH (2*. HEAT TO 190-194*F IN 55-65 MIN & REC:HT _____ *F 4, RECORD:___ ,_*F
NOTE: STRIKE MUST BE STARTED IMMEDIATELY ON COMPLETION OF HEATING.
J: .I
j 7-p
//
ctsjuir MENT I'.
i rout z uu 04 k u -v o v -u
COMTYF* JOB NAME: O4KQ909DMC
Uih. LBS
N- |HLLt
v CODE I LBS
WHILE HEATING SV, RUN 49* (1348 G) WATER INTO
343 ETER IN FROM V-386
.M&/G AL,&'_%GAL
STIR 15 MIN OR LONGER I RECORD: DENSITY ^03.G/ML (1.018-1.020)
I
27-D | 373
II II
WHEN S 20 HEATING COMPLETE, RECORD: PH/A#
SET V-343 ACID PUMP AT 69 SETTING (225 MIN)
SET V-349 SILICATE PUMP AT 54 SETTING (180 MIN)
IMMEDIATELY METER IN V-343 8 V-349. MAINTAIN SV
AT 190-194*F DURING STRIKE
RECORD:
START
V-343
&4f
MIND
V-349
&
TIME V-343
V-349
AL
. BINCHES INCHES
PH
AT 20 MIN ^1^(46 >42. (1?)j
(9.3-10.0)
40 nmt&jsfL (41 >=fe. (15 >iJL ^'^<9.3-10.0)
.1 HR
(37) stez. (13) -t_ 311(9.3-10.0)
2 HRS^feCf (23)44 ( 6) JL -&fc(9.3-10.0)
F3INIHSRHS *3i'^fe- (* a0>k __L
( 0)_*i-
9.3-1010)
- a> *7y_S-< 7.5-8.5)
NOTE: IF PH DROPS BELOW 9.3 IN FIRST HOUR, STOP
PUMPS & SEE SUPV. IF FINAL PH IS ABOVE
8.5; ADJ TO 7.5-8.5 & RECORD: _____PH
ASSUME 77% I___ ____
- 180** I
I '50-
27-D 4.aa~Ai -5ir
S^'TSPVADD 80* (485 G) WATER TO V-385
13^1 ADD t, STIR FOR 2 MIN FOR S 83
ASSUME 50% 296 I 7-D 148
!33T>H&tJRING STRIKE CHEC1C LEVEL IN V-387. 387 |34n^ LOW LEVEL LIGHT IS NOT LIT, GO TO S-37
8 |3rT IF LOW. LEVEL LIGHT IS LIT, VERIFY BY CHECKING
I LOW LEVEL PEG IN VAT IS ABOVE SURFACE \ 138-H IF VISUAL CHECK CONFIRMS LOW LEVEL, FOLLOW
STEARATE MAKE-UP PROCEDURE.
l-
\
I .1
RUN IN 27* (268 GAL).' DO NOT MAKE UP THIS SOLUTION MORE THAN 30 MINUTES IN ADVANCE. DELAY BETWEEN END OF STEP 43 HEAT-UP AND START OF STEP 53 HOMOGENIZATION SHOULD BE LESS THAN 30 MINUTES. N ON STEAM 8 AGITATOR
|39^1^W"JUST TO 37* (366 GAL) AT 178-182*F |40*T^SET BADGER METER FOR 5904
14JKH PUMP IN FROM 387 THRU UNDERSURFACE AS FAST AS POSSIBLE
HUT JDFF PUMP
'* ,
30 MIN AT 178-182*F FOR S 53
DO NOT SHUT OFF AGITATOR
482 54 54
i f 69-AI 482 I 155-AI 54 | 160-A1 54
WHEN V-349 MT, RINSE IN WITH MINIMUM WATER & SET PUMP AT ZERO SETTING
WHEN V-343 MT, RINSE IN WITH MINIMUM WATER 8 TURN OFF PUMP MOTOR
STIR 60 MIN AT 190-194*P
DUP050046958
EQUIP MENT!
PAGE 3 CG 04 K0-90?-/ 1 COMTYP JOB NAME: 4K0909DMC
I USE I LBS
N- i ACCT CODE I LBS
hi TO 198~200*F IN 5-10 MIN
CLOSE WATER LINE & DISCHARGE VALVES AT STEARATE
Imp 5( OPEN V-388 DISCHARGE VALVES TO STEARATE PUMP
-E,T" OPEN WATER VALVE AT STEARATE PUMP 4. RUN WATER '
THRU HOMOG AT 2900-3100 PSI TO SEWER WHILE HOMOG WATER, OPEN HOMOG DISCHARGE VALVE
SV 4, CLOSE VALVE TO SEWER ` IMMEDIATELY OPEN STEARATE PUMP DISCHARGE VALVE,
TURN ON PUMP 4t HOMOG V-388 TO SV AT 2900-3100 PSI, MAINTAIN SV AT 1,,98~200*F, WHIJJE HOMOG V-388 TO SV, SHUT OFF WATER VALVE
"*a t SHTF&RATF PUMP* AVAP1
WHEN HOMOG COMPLETE, RINSE IN V-388 WITH HOT
iATER FROM HOT WATER MIXER
t OFF HOMOG & STEARATE- PUMP
5 MIN AT 198-200*F
ISa^r^HUT OFF STEAM'
i IN ALUM USING BADGER METER
|6rCLUSH.ALUM LI&E WITH WATER
VO 160&RD: PHZl
<3,4-3.8)
IF NECESSARY, ADJ PH TO 3.4-3.8 (DOWNWARD ONLY)
& RECORD: PH'_____. NOTE: USE LIQUID ALUM,
N-115-D. ADD TO SV VIA BADGER METER, STIR
5 MIN, AFTER EACH ADDITION.
ASSUME 507.
IN N-7-D. FROM S-32 IN 4-6 MIN 4, STIR 5 MIN RECORD: PHJ^Z(6.2-6.4) 4, IF NECESSARY, ADJ
| TO PH 6.2-6.4 4, RECORD: PH&_3*" ASSUME 78%
I (DILUTE 10 PARTS TO 1 WITH WATER) ASSUME 50%
l^-SIPHON N-7-D INTO SV
DO NOT STOP AGITATOR
,.
j
950 115- D | 475 11 5-1 27-1 7-1 I^Eil
$r> Zr,
6
. J 2^6
II II I)
II II
I1 I I .1 I
DUP050046959
DUP050046961