Document kvMMDddDgDQnDDomYgmX5kX0

PLAINTIFF'S EXHIBIT FOAM P017 17------ ip _!=lj] CERTAIHTEEO DESCRIPTION: TECHNICAL SPECIFICATIONS CERTAIN-TEED PRODUCTS CORPORATION PIPE DIVISION SPECIFICATIONS CLASSIFICATION: Standard Purchasing Specification T.C.O. REF. NO. h SPECIFICATION NO: 501 PAGE NO.: 1 SUPERSEDES: May 15, 1968 OATE OF ISSUE: September 11, 1969 Pulverized Silica A. GENERAL 1. Description Pulverized silica, for purposes of this specification, consists of a high purity grade of natural occurring crystalline sand or silica which has been subjected to grinding and classification processes in order to control its fineness. In some cases it may be necessary to wash the sand or silica in order to improve its purity and color. The re fined pulverized silica shall be white to light gray in color. B. USE Pulverized silica reacts chemically with free calcium hydroxide formed during high pressure steam curing of Portland Cement. C. LOT SIZE For sampling and inspection purposes, a lot shall be defined as the quantity of pulverized silica shipped in a single carrier, or in one day. D. REQUIREMENTS 1. Special 1.1 Initial Approval All pulverized silica suppliers shall be approved in writing by the Technical Services Manager - Materials of Certain-teed Asbestos and Plastics (CAP) Division. Any change in the source of the silica or in its processing by an approved supplier must be authorized in writing by the Technical Services Manager - Materials before the end product may be supplied to CAP Division plants. 2. Chemical and Physical Requirements Chemical and physical requirements shall be in accordance with Tables A and B. CTD014953 PREPARED BY: APPROVED BY: r\y m n a o MFQ. SALES I.E. OTHERS CONFIDENTIAL DOCUMENT - NO^TO RE DISTRIBUTED TO UNAUTHORIZED PERSONNEL FORM P027 1 I CESTAKL'J description: TECHNICAL SPECIFICATIONS SPECIFICATIONS CL ASS 1 F 1C AT ION : CERTAIN-TEED PRODUCTS CORPORATION PIPE DIVISION Standard Purchasing Specification T.C.O. REF. NO. h | SPECIFICATION NO: 1 501 { PACE NO. : 12 SUPERSEDES : DATE OF ISSUE: Kay 15, 1968 September 11, 1969 Pulverized Silica E. TEST METHODS 1. Chemical and Physical The follovjing tests viill be conducted in accordance with the applica ble CAP Division Test Kathods. Test Free Moisture Content Loss on ignition Total silica (Si C^) Per cent available Si O2 Surface area Wet sieve analysis F. ACCEPTANCE AND REJECTION Test Kethod TK - 30 TK - 31 TK - 25 TM - 23 TK - 3 I'M - 2h CAP Division reserves the right to reject any lot of pulverized silica which does not conform to the requirements of this specification. If any lot is rejected,the supplier shall be advised within 2a hours and the reason for the rejection explained. G. PACKAGING AND MARKING Pulverized silica shall be supplied in bulk shipments by railroad car, truck or.direct pipe line. Unless otherwise specified, each lot shall be marked as CPC 501 Silica and identified by the delivery date. All invoices shall include this information. PREPARED BY: c CTD014954 j APPROVED. BY: -- r) (/' 0ft & MFG . SALES I.E. j'lt- CONFIDENTIAL DOCUMENT - NOT^TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL OTHERS TECHNICAL SPECIFICATIONS SPECIFICATION* CLASSIFICATION: CertairifeedU A/C Standard Purchasing Specification T.C.O. NEF. NO. SPECIFICATION NO! PAOE NO.: CertainTeed Corporation Pipe and Plastics Group oncmmoN: 8 April 25, 1973 501 3 DATE OF ISSUE: January 19* 1984 Pulverized Silica TABLE A Chemical Requirements - Type A and Type B Ingredient or I tern Max. % Min. % Free Moisture Content Loss on Ignition Total SiO2 Avaliable SiO2 1.0 1.0 95.0 90.0 I tern TABLE B Physical Requirements Surface Area, Blaine sq. cm./gram a. 98 + % Si02 (Total) b. 96 - 38% Si02 (Tota1) c. 95 - 36% SI02 (Total) , idue on U.S, Std. No. 220 Mesh Sieve, %, Max. lidue on U.S. Std. No. 325 Mesh Sieve, %, Max. Requirement Type A Type B -- 3200 A00 3300 300 -- 3600 300 -- 10..0 15-0 35..0 10.0 02- CTD014955 * ft o MFO. SALES I.E. o.c. OTHERS Q4S t- -ac-D ItTKIBin to unauthokiiio pmaoNNCC OOTCNIPTIONI Pu1verI zed Silica AT* OP IMUC January 19, 1984 qHwincATiOM no: 501 THIS PAGE INTENTIONALLY LEFT BLANK PAOC NO.l 3-A CTD014956 FORM PS27 1 . JLi CERTAtNTEED ocscrirtion: TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: Standard Purchasing Specification CERTAIN-TEEO PRODUCTS CORPORATION PIPE DIVISION T.C.O. REF. NO. SPECIFICATION NO: 501 Addendum supersedes: . May l5j 1968 PAGE NO.: 1 | DATE OF ISSUE: September 11, 1969 Pulverized Silica NOT TO BE DISTRIBUTED TO VENDORS 1. General This addendum describes the following: 1. Approved suppliers of pulverized silica 2. Testing 3. Rejection 2. Approved suppliers of pulverized silica: Plant - Pennsylvania Glass Sand Corp. Mapleton, Penna. Plant 3 Penn Center Pittsburgh, Penna. 15206 Plant 56 - (1) Pulverized Sand of California, Inc. Box 321$ Riverside, California 92509 (2) Del Monte Properties Co. 2607 Russ Building 235 Montgomery St. San Francisco, California 9U101: Plant 57 - Heart of Texas Mining Corp. 2510 Fidelity Union Tower Dallas, Texas 75201 Plant 58 - (l) South River Sand Old Bridge, New Jersey 08857 (2) National Glass Sand Co. P. 0. Box 1U5 Millville, New Jersey 08332 PREPAREO by: APPROVED BY! <50f R ft D 3E CONFIDENTIAL DOCUMENT NO MFO. AL SALES I.E. CTD014957 OTHERS FORM P9 27 CERlWNTtfO .description: TECHNICAL SPECIFICATIONS CERTAIN-TEED PRODUCTS CORPORATION PIPE DIVISION SPECIFICATIONS CLASSIFICATION: Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO. : 7 501 Addendum 2 SUPERSEDES: Sept. 11, 1969 DATE OF ISSUE: FEB 1 2 1974 Pulverized Silica HOT TO BE DISTRIBUTED TO VENDORS Plant 59 - (1) Pioneer Silica Products Pacific, Missouri Order from: I Pennsylvania Glass Sand Corp. 8000 Bonhomme Road St. Louis, Missouri 63105 (2) Wedron Silica Co. Wedron, Illinois. 60557 Plant 60 - Pulverized Sand of California, Inc. I Box 3215 I Riverside, California 92509 3. Testing 3.1. 3.2. Plant Testing The Quality Control Engineer at each CAP Division plant shall conduct the following tests each week on a representative sample. a. Surface Area - Blaine in accordance with Test Method TM - 3. b. Wet Sieve Analysis in accordance with Test Mfethod TM - 2h. For sampling purposes, the lot sample shall be composed of at least three randomly selected sub-samples of approximately two pounds each, properly composited `and quartered. The sampling may be done on the carrier prior to discharge, or at reasonably spaced intervals during the discharge operation. Caution should be exercised during sampling to prevent stratification of the sub-samples. Samples should be stored in a clean, air-tight, dry container. PREPARED BY: (._ C--^ rx /L-APPROVED BY: --' <w R aO MFG. SALES I.E. (MS CONFIDENTIAL DOCUMENT - NOT tS/"E DISTRIBUTED TO UNAUTHORIZED PERSONNEL OTHERS CTD014958 FORM P927 I l- CEKTAINTTED description: TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: CERTAIN-TEED PRODUCTS CORPORATION PIPE DIVISION Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PACE NO.: b 901 Addendum 3 supersedes: DATE OF ISSUE: May l, 1968 September 11, 196? Pulverized Silica b. Rejection Lots of pulverized silica which do not conform to the requirements of this specification may be rejected by the Plant Quality Control Engineer after consultation with the Plant Manager. In some cases the Plant Manager may decide to use substandard silica rather than stop production. If a lot does not conform to this specification (even though it is used), Plant Purchasing, Quality Control Manager, Technical Services Manager - Materials and Central Purchasing shall be informed as soon as possible and the reason for nonconfor mance explained. Plant Purchasing will notify the supplier of all rejections and sub-standard material. PREPARCO BY: APPROVED by: R&D z MFC. SALES I.E. CTD014959 OTHERS