Document kp5ODqmgvjJVEzzaqvwkRZxV

C.A. Dunham Company Specialties, Heating The "D" series Dunham Central Station Heating Differential Vacuum System is for the heating of office buildings, hotels, apartment --y/Difr~ensbal~\hcm The Dunham Differential Vacuum Heating System is houses, schools and groups of especially adapted to Central buildings, etc., of more than Station Steam Supply. It 3,000 sq. ft. of equivalent di The Dunham Differential Vacuum offers great economy of steam rect radiation. Heating Sjratem and individual consumption and very low The boiler serves as a heat storage from which steam is supplied according to the de parts of the apparatus used in that system are fully protected by United States Patents Nos. 1,644,114 and 1,706 401, and.Can* condensate temperatures. Another advantage is com plete circulation even though mand of the Sub-Atmospheric Pressure Reducing Valve or Temperature Control Valve. adian Patents Noe. 282,193,282,194 and 282,195. AdditionaJ patents in the United States. Canada and foreign countries are now pending. the pressure carried on the distributing mains from the boiler plant is low. This sys The manually controlled sys tem therefore is ideal both tem uses two sub-atmospheric pressure re from the standpoint of the Central Station ducing valves. The small valve "A" supplies Company and the Consumer. steam in mild weather, valve " B " in cold weather. In extreme weather both valves Exhaust Steam may be used, if necessary. By shifting the weights of the valve in use, the steam pres sure (vacuum) is controlled in accordance with outside weather conditions. In the automatically controlled system a Temperature Control Valve "C" is sub stituted for valve " B." The Dunham Differential Controller starts and stops the pump maintaining, under all steam supply conditions, a greater vacuum in the returns than in the radiators. This assures complete circulation at all times. In severe weather when steam pressure above atmospheric is required (to maintain the room temperature) the Dif ferential Controller automatically stops the pump until pressure conditions in the system make its operation necessary. Exhaust steam may be circulated under vacuum, thus saving steam formerly wasted. The application of this system re duces the back pressure to a vacuum and greater power output will be obtained. In installations where high steam pres sures and temperatures are necessary for process work the building heating system can be operated more economically by ap plying the differential principle to it. By reducing the high steam pressure through reducing valves the heat input may be con trolled and the overall economy of the plant improved. ' Dunham Differential Vacuum Pump, ``D" Series The Dunham Differen tial Vacuum Pump oper ates on the Jet Exhauster principle. The Dunham Exhauster is a special de sign and has great air and vapor handling capacity. Under high pressures water is supplied from the receiving tank to the ex hauster by a motor driven enclosed impeller type centrifugal pump of high efficiency. The pump exhausts air and water from return piping under very high vacuums and discharges condensate to the boiler. It is a completely assem bled compact unit ready for piping and wiring con nections. 792 C. A. Dunham Company Specialties, Heating Dunham Thermostatic Radiator Trap Sectional View of Trap Sectional view of Dunham Differential Thermostatic Radiator Trap, sixes, etyles and specifications, see Dunham Hand Book. All traps used in connection with the Dunham Differential Vacuum Heating System are known as "D" Series. They function uniformly over a wide range of pressures*and temperatures from 25 in. of vacuum to 25 lb. gauge pressure. Dunham Packless Radiator Valve Types of Control The system of control is arranged so that: A single valve may be controlled by a single thermostat. A single valve may be controlled by several thermostats. Several valves may be controlled each by its own thermostat. Several valves may be controlled each by several thermostats. The control panel in each case is cen tralized in the boiler room. Where heating systems are divided into complete zones (or for systems where only one thermostat is intended to control one valve) Control Panel Type 391 is used. Either control provides the following advantages: It centralizes control of the entire steam supply. It permits either automatic or manual operation. It gives the attendant the information he desires regarding temperature condi tions prevailing in various parts of the building, in addition to informing him whether or not the valve is admitting, steam to the system. Each panel is provided with a red and a green light for each thermostat and valve. Switches are provided for transferring the Sectional View, Type 105, Dimham Packlut Radiator Valet with Regulating Platt For sixes, styles and specifications, see Dunham Hand Book. Dunham Packless Radiator Valves with Regiilating Plate must be used on all radia-; tors to secure proper balance. Either Type 105 (lever handle) or Type 145 (wheel handle) njay be used. The valve is made packless by means of the bellows construction. The plate orifice is calibrated to the number of feet of radia tion in each radiator. Dunham Regulating Plate, Type 192 793 Type 891