Document kok2qmojNzDrxX1VLerLNd9O

CL & ^c> PYDRAUL' AC saves maintenance costs A serious problem facing air compressor operators has been the hiv^h maintenance costs of cleaning valve deposits caused by petroleum lubricants. Further difficulties are high exhaust temperatures resulting from mal-function of valves and high cylinder temperatures that cause varnish deposits on cylinder rings and walls. With years of experience in the synthetic lubricant field behind them, Monsanto researchers sought the answer to this plaguing problem. After testing many types of fluids, they found a fire-resistant lubricant that proved to be ideally suih-d for air compressors. They called it Pydraul AC. Pydraul AC reduces exhaust valve and air compressor piping deposits to a minimum in all types of air compressors. Fewer carbon deposits on exhaust valves and in interstage equipment means a substantial savings for the operator who must pay the cost of cleaning as well as the co6t of down time on the equipment. Lower maintenance cost alone usually justifies the use of Pydraul AC in air compressors. KQI*S 0 7 2 3 0 4 removes explosion threat There are nearly as many theories as there are men voicing opinions as to why fires and explosions happen in air compressor systems, but one point is generally agreed upon: petroleum oil lubricants are directly involved. - Apparently, oil mist and films gradually accumulate throughout the air system. These break down into combustible gases and carbonaceous residues that can ignite to produce an explosion or receiver fire, or both. Pydrtutl AC has proven its ability to reduce these hazardous residues to an absolute minimum or eliminate them completely! By minimizing residues, Pydraul AC effectively reduces the threat of compreasdr fires and explosions. And Pydraul AC is fire-resistant It provides safe operation, protecting not only the equipment, but the lives of workers as well. MOW HONS 0 7 2 3 0 5 COMPRESSOR EXPLOSIONS.... UNPREDICTABLE The history of compressor explosions shows an unfortunate fact--they are entirely unpredictable. They can occur in small compressors operating at 50 psig. and in large installations operating at very high pressures. There is no pattern, no way to predict the safety of a particular compressor operation. Such explosions and fires are considered infrequent by some people- In fact, an air compressor operator might go along for yean without an accident. However, when they happen, these explosions and fires can blow entire compressor systems apart and even rip yard piping out of the ground. The cost for equipment loss and down time from these accidents can be staggering. Fire-resistant Pydraui AC essentially eliminates the basic cause for most fires and explosions by minimizing the carbon deposits. Its superior oxidation resistance adds to its ability to reduce explosions: by resisting burning in air, Pydraui AC holds the explosion threat to a minimum. PYD R AU L AC fm/ri' TT-s r rrr :r \ . '* ICC (Viiipn 'M)! np. r.iloi'- hive k*'|>( ;i < watch on the development of Vyilnml AC. seeking the nn-wor to one paramount question "How well (|(h> I'ydraul At lubricate?' With lobricnl intz qualities proven equivalent to tho>e of the highest grade pclri drum oil. I'ydraul AC has demonstrated its operating efTuienev in air compressors of almost every conceivable ty|K\ The statement of a lubricating engineer quoted below typifies its reception as a lubricant. Thr compressor was a Coni>or-Bpssomcr .J M-5 Ineated in a large Midwestern plant. "Lubricating pro[?ertie> of Pydraut AC hal f hern rrry satisfactory. Wear measurements an Maly/xik rings taken approximately free months later indicate 0/X).t" U '-ar. Till- is normal and considered eery good. So rornxior, of cylinder liner*, calces and piping has hren t-rpcni-rv ed. and service <> eery <nt ~}mloiy . l .uC N ihii'. Kn-iin '-r 6 T in o *0 rv u o O' LOZZLO SNOW Or iOOUSTRiAL A'R COUPRzSOO v VAL VF HONS 0 7 2 3 0 8 PYDRAUL (. AR&ON DL PCS/To The photos on the opposite pace compart exhuu-t \nhe deposits formed during (hr ."iOn-hoar o|H ration on two lubricants: one. a premium crude pep'oleum nit. and the other, f'xdraul AC. Deposits former! from the ".IKl hour o|x-ration on ixdroleum oil were reirrnvxl before the \nhr began o|ernting on Pvdnwl AC so the valve w;r- perfectly clean lieforo each operation. A glance at the photo on the left shows that a considerable amount of cnrlx>n formed in the normal ">(X) hour take-down period for petroleum oil. The photo on the right shows the great improvement when the valve o|>ernted ufH) hours on Pydraul AC. In this particular case, (he compressor operator exfxtts to get TaOO to 10,0<X) hours of service from Pydraul AC without shutting down a 1-V to 20-fold increase of operating time without a shut-down. Thais a substantial saving of time and money due t<> Pydraul AC SONS 0 7 2 3 0 9 VDRAUL AO , America^ Messer Corporation Bury Comoressor Company Chicago Pneumatic Tool Company Clark Brothers Company Cooper-Bessemer Corporation De Laval Steam Turbine Company Fuller Company Gardner-Denver Company IngersoM - Rand Company Joy Manufacturing Company Norwalk Company. Inc. Schramm. Inc. Worthington Corporation Pyrirnu! AC ha* heen list'd as an air compressor lubricant for jK-riods up to five year* and is now successfully luhricalini: hundmfs of compressors of all tvpos and sires prcnluccd bv all of (he* major compressor manufacturers. I V'lM-ndiibfc iM'iformam*** is the reason for its wide aixeulanie. Pvtfrniil AC' is Iwinc user? to lubricate air cylimlers in a numlw'r of compri-wors at pn'ssures over k'Oft (rsii: Mnnv compressors h\e ofrrat*d continually uith exhaust air lemjieraturos of :Vtt> F !| ~V I Kxtonsive field experience has proven that the required lubrication rate with Pydraul AC closely approximates that of fx'troleum oils. When installing new equipment, it is well to start with an increased lubricant feed rate and reduce by successive increments. Inspection of cylinder walls and valves indicates the proper degree of wetting. On installations converted from petroleum oil to Pydraul AO, the same feed rate as for the petroleum fluid should be adequate. 0................................... < JX o 32 MAS NORMAL USE RATE (/) < KO u N> Q O 1 HONS 012311 GNVERVNQ TO PYDRflUL AO /S EASY The conversion of air compressor systems from petroleum lubricants to fire- and < \p|osir>n-resi?tant Pydraul AC i simple, but one procedure is vitally important to insure smooth, efficient operation with Pvdraul AC. Exhaust valves and interstage equipment should be thoroughly rlcnncd before installation, because Pydraul /AC will loosen carbonaceous deposils. which may cause unnecessary maintenance down time and production loss. Once the valves have been thoroughly cleaned of harmful carton deposits. Pydraul AC keep* them clean--lets you run longer between maintenance shutdowns. standard check for compressors plastic separator bewts Not all plastic separator bowls are suitable for Pydraul AC service because certain plastics are "crazed" or softened when exposed to it. Though separator bowls can be molded of plastics that are totally resistant, for the present it is safest to use glass, brass or steel bowls. If there is a question as to the resistance of a particular plastic, Monsanto will be happy to advise if the material is suitable. diaphragm valves Pydraul AC has a softening effect on the "Neoprene" or Buna N rubber diaphragms that are normally used for petroleum oil service. These rubbers should be replaced with butyl rubber materia! which is resistant to Pydraul AC. Butyl diaphragm sheeting is available from normal sources of supply. All diaphragms in unloading valves or downstream control valves should be replaced at the time of changeover. Diaphragms in valving downstream from separator systems or drying systems need not be replaced at changeover time, but should be changed on a preventive maintenance schedule as soon as practicable after operation on Pydraul AC is begun. special check for splash - lubricated compressors crankcase pa-nt Sin<t the paint ll'Cd on crankcase interior' of some compressors wili in nnM < is<>-. I>< -iifon.-.l .<rjf| eventually removed by Vydraul AC. the point should Is- removed. W f<iI. tin p.unl p.uh li - miclif p.i^ thmugh the lubricant pump, they could conceivably block the lubricant 'l u< ii fou . ton-ovir.e this paint i> good practice Standard paint solvents are adequate for removing the paint special check for force-feed lubricators sight-glass fluid If a separate force-feed lubricator of the type normally fillet! with water and glycerine is used, one of two chances is necessary: either replace the sight-glass fluid with one heavier than Pydnmt AC or irwrt a metal hohtver in the sight-glass. f'ydraut AC is heavier than water or glycerine and will not rhe through these standard sight-glass liquids. "Fluorochemica! 101." a dear liquid supplir'd hv the Minnesota Mining and Manufacturing Company, has a higher density than Pydraul A(' and is a completely satisfactory replacement. metal bobbers The alternate to using "Fluorocheniical 101" is to modify the sight-glass lubricator by inserting a simple metal bobber. The bobber is installed by draining the sight-glass liquid, removing the guide win' and inserting the bnblier. Operation of the lubricator is then indicated by movement of the Imblrer with each stroke of the pump plunger instead of counting the drops as with guide win's Bobtwrs are available for (`it her McCord or Man/ell lubricators .as McCord put number or Man/el) part nmnU r K2 I02I-B. Modification of tin* Madison-Kipp lubricator requires replacement of (lie entire sight-glas.- with (heir numlx'r C-CV-300 oil feed indicator vacuum-sight lubricators Vacuum-sight lubricators require no modification for Pydraul AC usage. HONS G7 2 3 1 2 i i RYDRAUL AC /S SAFE TO USE "Pydraul AC ha? .an extremely low order of oral toxicity to experimental animals. This, together with experimental data which shows that rats survived a 6-hour exposure to an atmosphere saturated with Pydraul AC vapors, attests to its safety for use in air compressor systems. The material is irritating to the eyes and can cause smarting and burning, but no permanent damage has rpsulted." Monsanto Medical Department 1/1 111 h ltat ill A BU fVt K AQ. J V fl. > h o Z (/> U> Viscosity, 'SUS) 50 F lbJ F. 1005 F 130 F. 2105 F. Pour point, 0 F. Neutralization number Specific gravity, 605/60' F. Auto-igniting temperature Solubility of water in Pydraul AC 75` F 210' F. Solubility of Pydraul AC in water 15,000 1,650 410 127 43 20 015 maximum 1 35 1.100' F. 0 1 per cent 0.4 per cent Negligible For applications requiring significantly different properties, such as intermittent operation of a portahlc compressor in areas of low ambient temperature, a fluid similar to Pydraul AC con be provided. Contact Monsanto s Functional Fluids Department jor details. 1 H 1 B 1 _____ 11 Shipping Information Cliissifiuliun, U S.A Regulations Standard < *inlain<`i> Chemicals. NOIBN None Vt-gal Ion. itonfvturn.iMc. til.uk iron drums. <i|0 Hs mi ` gallon drums -Vi Ihs. m-l MONS 0 V 2 3 1 5 r PYDRAUL ACcroev CONTACT THF. SAITS OFFICE NEAREST YOL- For samples or nddi'inrnl inform.ilkm. urifr Mnnvinlo Chrmic.d Conni.-inv. 0ri-'.Tnf<- fhomk.-ils Division Funrlion.t) Fluid- f>. <) |F)X 47s. c, [ynij- ) m<, AKRON ATLANTA BOSTON CHICAGO CINCINNATI CLEVELAND DETROIT HOUSTON LOS ANGELES MINNEAPOLIS NEW YORK SAN FRANCISCO SEATTLE WILMINGTON LONOON MELBOURNE MONTREAL TORONTO VANCOUVER 920 ---OWN STREfT AKRON 11 OHIO 'AO' PEACHTREE STREET NE ATLANTA 5 GA EVERETT STATION BOSTON A3 MASS 520 N MICHIGAN AVENUE. CHICAGO 11. ILL 2330 VICTORY PARKWAV CINCINNATI 6. OHIO 427 HANNA BU'LOING. CLEVELAND 15 OHIO 18230 GRAND RIVER AVE - DETROIT 23. MICH 90^ CITY NATIONAL BANK BLOG . HOUSTON 2. TEXAS 66TO E FLOTILLA STREET. LOS ANGELES 22. CALIF FOSHAY TOWER. ROOM 409 MINNEAPOLIS 2. MINN 445 PARK AVENUE. NEW YORK 22. N V in SUTTER STREET. SAN FRANCISCO A. CALIF 911 WESTERN AVENUE. SEATTLE 4. WASH 4335 GOV PRINT! BOULEVARD WILMINGTON 99. DEL MONSANTO CHEMICALS LTD , MONSANTO CHEMICALS (AUSTRALIA) LTD MONSANTO(CANADA)LTD Representatives in the Fnnvipnl i itirs / (hr W'nrM <o H m U> * O X