Document kmxg2xQ12nVMEeK1b5xvpyXQE
Report No. A2210057913101001 Test Report
Page 1 of 4
Company Name shown on Report Address
CHANGZHOU XCF POLYMER MATERIALS CO., LTD. NO.999 DINGJIAN ROAD, DINGYAN TOWN, CHANGZHOU, 213025 CHINA
The following sample(s) and sample information was/were submitted and identified by/on the behalf of
the applicant
Sample Name
PTFE White Staple Fiber
Color
White
Sample Received Date
Feb. 26, 2021
Testing Period
Feb. 26, 2021 to Mar. 4, 2021
Test Conducted: As requested by the applicant. For details refer to next page(s).
Tested by
Reviewed by
Approved by
Hill Zheng
Technical Manager
Date
Mar. 4, 2021
No. R187213774
Centre Testing International Group Co.,Ltd.
CTI Building, Xing Dong Community, Xin'an Sub-district, Bao'an District, Shenzhen City, Guangdong Province, P.R. China
Report No. A2210057913101001 Executive Summary:
Test Report
Page 2 of 4
TEST REQUEST Refer to FDA 21CFR 177.1550 Perfluorocarbon resins
- Total extractives - Fluoride extractives
CONCLUSION
PASS PASS
PASS (FAIL) means that the results shown on the report (do not) comply with the required limits.
************* For further details, please refer to the following page(s) *************
Report No. A2210057913101001 Test Report
Refer to FDA 21CFR 177.1550 Perfluorocarbon resins
Total extractives
Test Method: Refer to FDA 21CFR 177.1550
Test Item(s)
Distilled water extractives 50% ethanol extractives N-heptane extractives Ethyl acetate extractives
Result
001 N.D. N.D. N.D. N.D.
MDL
0.5 0.5 0.5 0.5
Fluoride extractives
Test Method: Refer to FDA 21CFR 177.1550
Test Item(s)
Fluoride extractives in distilled water Fluoride extractives in 50% ethanol Fluoride extractives in n-heptane Fluoride extractives in Ethyl Acetate
Result
001 N.D. N.D. N.D. N.D.
MDL
0.05 0.05 0.05 0.05
Page 3 of 4
Reference Limit
3.1 3.1 3.1 3.1
Unit
mg/dm mg/dm mg/dm mg/dm
Reference Limit
0.46 0.46 0.46 0.46
Unit
mg/dm mg/dm mg/dm mg/dm
Remark: - MDL = Method Detection Limit - N.D. = Not Detected (<MDL)
Sample/Part Description 001 White plastic staple fiber
Note: - The testing data and result(s) in this report is(are) just for scientific research, education, internal quality
control and product development etc.
Report No. A2210057913101001 Test Report
Photo(s) of the sample(s)
Page 4 of 4
Statement: 1. This report is considered invalid without approved signature, special seal and the seal on the perforation; 2. The Company Name shown on Report and Address, the sample(s) and sample information was/were
provided by the applicant who should be responsible for the authenticity which CTI hasn't verified; 3. The result(s) shown in this report refer(s) only to the sample(s) tested; 4. Without written approval of CTI, this report can't be reproduced except in full; 5. In case of any discrepancy between the English version and Chinese version of the testing reports (if
generated), the Chinese version shall prevail.
*** End of Report ***