Document kmp26zaKRnYjLgN9ye8eNB6ND

EXHIBIT I DUP-256 E. I. du Pont oe Nemours S Company Wilmington. Delaware PASRIC> ANO FINISHES department January 2, 1969 J. A. ZAP?, JR. EMPLOYEE RELATIONS DEFT HASSELL LABORATORY ASBESTOS ETBER As tha rasulc of a recant article in The Delaware A.C.S. Bulletin, copy attached, a question has been raised as pertains to our current handling precautions of asbestos fiber. We employ approximately 100 tons of asbestos fiber annually as a raw material in our division, primarily as an ingredient in radiator stop leak compounds and as a filler in cement block primers. This implies that a limited group of operators who charge these materials into mixers are exposed to asbestos dust for a fairly short period of time but on a regular repetitive basis. Currently, we have these materials classified "S-L", which imposes the wearing of a cartridge filter type dust respirator during handling, but do not require any other extra ordinary precaution. We would appreciate your comments as regards the actual degree of risk involved in handling asbestos fiber and the adequacy of our current procedures. ABN:ejy Attachment / RECEIVED jAN 3 1555 HASKELL LABORATORY PAR means Safmtv -- First a Foremost DUP 1200009 ------------------ C>' "> YEAR 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 I960 1961 1962 1963 1964 1965 1966 1967 1968 Total TOTAL 51 54 62 41 67 61 88 73 79 68 79 86 100 100 84 118 126 104 120 l,56l DECEASED PULMONARY 7,-' 2 2 5 2 3 8 6 5 5 9 14 . . .9 8 15 10 18 ^ 11 12 21 165 CA OP L (2) (2) (2) (2) (2) (5) W (2) (2) (3) (5) (1) (4) (7) (3) (6) (1) (*) (H) (68) V 'J 2 ACTIVE EMPLOYEES WITH CA OF LUNG T - Salary J1 - 52093 2-21-69 mew Ralph D. Jaquett William S. Leuallen .j .A* ^ DUP 1200010 iBia-v iajai1iai.faiiliaaaa. EQUIPMENT AMD PROCEDURES FC ACT COUNTING ASBESTOS FISEES BY PHASE CONTRAST MICROSCOPY Stephen G. Beyer Ralph D. Zutnvalde Thomas A. Brevet Bureau of Occupational Safety and Health 1014 Broadway Cincinnati, Ohio 45202 JULY 1969 IT. S. DEPARTMENT OF HEALTH, EDUCATION, AND WELFARE Public Health Service Consumer Protection and Environmental Health Service Environmental Control Administration DUP 1200011 TAV." OF CONTr"S Tntroduct{on---------------------------- ------------- ------- - ------------------------- -------------------------- i Equionent L**t-------- ----------------------------------------------------------------- .................................. j Uboricery Set-uo--------------------------------------------------------------------------------------------- l Preliminary Microseone Sec-uo-- ------------- ....------------------ ....------------ -------... 2 Microscope set up end the Procedure for obtaining Kohler Illumination---- 3 Detailed Instructions for Bausch and Lomb Binocular Microscopes------------ 5 filter Mountina Set-up prior to mounting------------------------------- ...........------------ 5 Mounting procedure------...............------ --------..........-- ---------- 5 Microscone Precautions and Maintenance-- -- --------------------------------------- -------- 7 Counting Procedure-------- ------------ ------- ------- -----------------------------------------------------7 Field Monitor Discussion-------------------------------*---------------------- S Calculation of Concentration-------------------------------*---*--*------ 9 Addresses------------------------------------------------------------- -- ...................-------------- ; 1 DUP 1200012 *i 70RrV2PD To determine eoncentraf'ors of asbestos dys: in air for eonoarfson with established hygiene Units, a sinolc reoroducible method is required. A simoie anH inexoens've sarnlir.q method uses d'`soosab!e (reloadable if desired) olast'c ner.b-e.ne filter holders, ore* loaded with membrane filters. These membrane filters may be rendered trsnsoarent and the asbestos fibers counted with a nhase-ccntrast microscooe at &30X (or &00X). This method has been used bv the Asbestosis Research Council ir Creat Britain and the U.S. Public Health Service in the Urited States of America. It is soeci in the oronosed change for asbestos in the 1968 Threshold Limit Values ( of the American Conference of Governmental Industrial Hygienists. Uniform orocedures must be used for carrying out these counts is reproducibl results are to be achieved. Detailed equinnent and orocedures used by the U.S. Public Health Service are described here. \ DUP 1200013 -1 INTPOLt'CTTCW For fever*1 years, a set method for counting and siring airborne particulate matter, vhieh has been deoosited uoon membrane filters, has been used. The filters used in this technique are 37 ms diameter cellu lose ester membrane Alters manufactured by Millioore Corporation, (cat. bo. MVP03700). The slide mounting technique refers only to these filters, and will not work for any others. The filters may be ourchased oremounted in convenient field monitor eases, and are ready for samoting. The filters are nearly ICOT efficient for any asbestos dust, even for fibers v<th diameters much smaller than the 0.8 micron (u) pore size. Samole nreoaration for electron and optical examination are both relatively sim.ole. Slid* mounts of the filters are semi-oermanent. The following procedures and reeoraendatlons will produce accurate results, if each step is performed exactly as indicated. PQUiprerr T-TS~ 1. Table 2. Adjustable chair 3. Phase contrast microscope 4.. Ribbon filament illuminator or (built-in illuminator) 5. Rye oiece reticle (Porton tyre) 6. Lens tissue 7. Small camels hair brush 8. Slides 9. Cover slips 10. Spatula 11. Tweezers 12. Scalpel 13. Vbaaton Balsam bottle LABORATORY SET-UP Tt is important to provide a suitable counting area, for the room in vhieh the countina is eo be done has a great baar<ng uoon the microscopist. It should be out of the way of normal traffic, and ba kept as fret from dust and smoke as possible. The cables on which ehc microscopes are olaee should ba as free from vibrations and shoeks as oossible. An adjustable chair will do much to add to the comfort of the counter. DUP 1200014 - 2- psnTvriJisv VTrv^?COPT STT .VP Before any dusr sizing or counting cm be done, proper equipment must be at hand. This section describes the required equipment. The illuminator should be small and reasonably comoact. Ribbon filament illuminators are generally much easier to use. The illuminator must ir.coroorate a condensing lens, so that the enlarged image of the lame fila ment may be focused <n the olane of the substage condenser diaohr'agm. The illuminator must also have an iris diashragm located as near as possible to the condensing lens. The iris serves as a field diaohragn and is focused in the olane of the soeeimen. The microscooe used must have a substage condenser fitted vith an iris diaphragm. This iris serves rs an aperture diaphragm. The microscooe should have a calibrated reticle inside the non-adjustabie eyepiece. The reticle should bs small enough that all the counting field is in focus (if the flat field objective and eyepieces are used, essentially the en tire field will be in focus). The microscopes must be equipped with phase contrast accessories. Using phase contrast, even objects with almost the same refractive index as the mounting media can be seen. Light waves which travel through such a specimen are retarded by a fraction of a wave length to produce a change in phase. The phase contrast ootieal system reveals these phase changes as light or dark contrast against the back ground. This procedure was written by a user of Bausch and lemb ohasa-equioned microscopes, so that microscope set-uo procedures correspond with these. However, any good mieroscooa with phase contrast accessories will be satisfactory. For continual routine examination of filters, the binocular type microscope is much more comfortable. The use of a first surface mirror is racommended, but not necessary.. By utli.zing a second surface mirror, multiple images of the illuminator field lr's era formed which will detract from the crisp ness of the final image. As mentioned previously, the microscope must contain a reticle. Any reticle, auch aa the Porton or Patterson Globe and Circle, which projects a constant counting area and has provision for sizing, will work. The Porton reticle which we use outlines a raerangle that fits easily within the periphery of focus. The raeeanalc is divided into two squares. The left square is divided into six rectangles which constitutes tha counting arts. Above anc below the large rectangles art a scrlts of circles in which every other circle doubles in diameter. Her.ee,the third is twice ehe diameter of the first; the fourth is twice the size of the second, etc. The right half of the rec tangle contains a scale for extending the size above the number nine circle. The formule t>*L v/2^ describes the circles sizes. The diameter 0 is fpur.c from L which is the unit of length, and S which represents the number c: :he circle. L Is determined by calibration with a stage mieromeeer. The er.cire DUP 1200015 length of the rectangle is 200 L units. By measuring the length end dividing by 200, "I" is obtained and the circle sites may be calculated. Whenever a microscooe is disassembled or cleaned, the reticle calibration should be checked. Another fact to take into consideration is that changing the in.terpuoillary distance of the binocular will change the calibration, so the microsconist may want to check the calibration at both extremes of adjust ment. The counting area on the reticle should be kept as clean as possible, at dirt on the reticle is in focus and may be counted. MTCROSCP?? ST? T? AMD TF.F. PROCEDURE 70? OBTAINING KOHL23 TIIUMINATICN By utiliring equipment that meets the requirements just mentioned, any counter may achieve eomoarable counts after some oractice. This section will deal with setting the microscooe uo and obtaining kohler illumination. It is extremely important that every steo be followed exactly as indicated. 1. Place the microseooe on a flat, level surface at a height such that the eyepieces may be observed without strain cr discomfort. 2. Place a moderate dust sample upon the stage. 3. Place the illuminator directly in front of the aicroacooe. Sight across the two and be sure they are aligned. For coil filament bulbs the illuminator iris should be two inches from the center of the microscope mirror. For ribbon filament bulbs, the front of the filter holder should be seven inches from the center of the pltne s<de of the mirror. Never use the curved side. 4. Remove all diffusing filters from the system and insert a neutral density filter and a clear blue filter. Blue or green colored fil ters may be used at the discretion of the mieroseoplst. ROTE: Where the microscope includes a built-in illuminator to give Kohler illumination, the above steps will not all be necessary. REVIEW A. Cheek mieroseooe end illuminator alignment. B. Cheek the distance beeveen the microscope and the Illuminator. C. Be aura that you are using the flat side of the mirror. O. Make sure that there ere only two filters in the system. 5. By seans of the focusing knob on the side of the substage con denser eescr.bly, raise it until the upper lens nearly touches the bottom of the slide. Remember that the free working disiar.ee of the condenser is in the order of 1.2 am and that the slide is about 1 mm thick. DUP 1200016 -4- 6 . Turn on the illuninetor. Using the tilt controls, direct the beem onto the center of the nicrror. Then by tilting the mirror direct the beer, upward into the condenser. 7. Close the substaee iris completely. Open the illuminator ''ris all the way. 8. By means of the focusing controls on t he side of the nominator, focus the image of the filament on the bottom of the subseage ir s. This may be done by leaning over the mlcroscooe and observing the substage iris in the mlcroscooe mirror. (On such mode's r* the Bausch & Lo'.r.b P3-27, there is a f*n focus knob at the rear of the illuminator). In that case, move the condensing lens all the way forward and trim the focus with the fine focus knob. 9. Onen the substage iris about half way. ggVTEV A. Check the distance between the slide and condenser. B. Be sure that the beem is striking the center of the mirror, and that it is being deflected uovard into the condenser. C. Please reneat sreo 7. D. Cheek sten 8. Tf the image is not in focus now, correct it. Do not continue untit the filament is correctly focused. *. Please reseat sten 9. 10. Put the 10X objective in olace and focus on the samole. This is done as follows: First, looking from the side of the mieroscooe, lower the objective until it gets very near to the slide. Then, by looking through the eyeoicees, fees un. Never focus dour, with eoarsa focus when looking through cycoleces. A word o* caution; The objective lenses are very expensive, so be careful not to grind them through the slide. Always focus us. Now trim the focus with fine focus knob. Focus sharoly on the sample. Secondly, close the field iris fully. Tf the condenser is nearly in focus, you should set a bright snot of light. By using the condenser focus knob, bring the field ir4s into share focus. New, both the field iris and the- objective are in focus on the sample. Tf there appear to be multiple images of the field iris, it is because of the second surface mirror. Some of the light waves art raflectad from the first surface, resulting in secondary images. 11. If the image of the field Iris is not centered, re-center it by tilting the mirror. If the color around the field ir,-s is not uniform, re-eheck the tilting of the illuminator. DUP 1200017 Wi pry? t\j - 5- A. Check end he sure you re focused on rhe sample. lOX objectives have a relatively long foes1 length and it may be noss'ble to focus on: (a) the ton of the cover slio. (b) the semole. (c) the bottom of the filter, (d) the too of the s1<de. (e) the bottom of the sl'de. (f) the too of the condenser. So be sure of the focal olane. B. Be sure that Che field iris is focused In the samole plane. Check this often when examining samples. As the samole focus changes, so does the condenser focus. C. Re-check the centering and tilt of the illuminator. psta^lfp irstfvcttoks fo? bacsch and lcmb birocvlap microscopes 1. Leave the microscope phase ring on 0. Insert the telescooe that is suoolied with the kit into the right eyepiece tube. Focus on the dark phase ring. Onen and elose the substage iris to be sure that it is centered in relation to the objective phase ring. If it is not in the center, loosen the set screw on the condenser mount and orooerly sec the condenser. Then re-tighten the set screw. This should very seldom be necessary. Po not force anything and be careful and patient. Vhen you are satisfied that the condenser is aligned, ooen it all the way. 2. Turn the nhase wheel to 10. This shows chat the 10X phase ring is in place. Look through the telescooe again. By using the adjustment screw on the side of the condenser, move the rings, until they are perfectly concentric. When changing phase rings, move them carefully, so as not to knock the condenser out of alignment. 3. Turn to the 43X objective. Carefully turn the wheel to the 43 nhase ring. Align the two rings in the same manner as performed in step 2. 4. Remove the telescooe and reolace the eyepieces. Again, check the conden ser focus. You are now ready ro examine the samole at 430X, assuming that you arc using 10X eyeolcces. FILTER MnUNTTVG Set uo ?rior to Mounting Rave available at hand a quality scaloal and a suooly of Ro. 10 curved blades, a pair of tweezers (fine oointed are oreferred), a snaeule or fire polished glass rod end e box of lens tissue. Slides (1" x 3" or 25 x 75 am) with DUP 1200018 mm -6 - the date, sasmle number, etc. It i* advisable to use quality number 1-1/2" cover silos. Most dry objectives are corrected for this thickness cover glass. The mounting media should be kept in a Wheaton Balsam bottle. The edge around the lid should be coated with stopcock grease to keeo out the surrounding a<r. The mounting solution may now be prepared. A one to one solution by volume of dimethyl phthalate end diethyl oxalate is poured into the balsam bottle. Then add 0.05 gram of filter material for each milliliter of solution. The added filters increase the viscosity of the solution. Before using the solution, all of the filter material must be dissolved and the solution must be of uniform consistency. This may require a day or so with frequent stir ring. Refrigeration may add to the shelf life of the solution. Mounting ',oeedure Keen in mind that cleanliness is important, first, lay down two pieces of lens tissue; one directly in front of you and the other to the left or right for the mounting tools. Next, wipe the scaloel, tveerers and glass rod or spatula with the frosted end toward you. Sven precleaned slides must be cleaned this wav. Hold a cover slin by the edges between the index finger and the thumb, and clean <t in the same manner as the sl'de. Place the cover slip so that one edge rests on the unfrosted end of the slide and the other edge rests on the lens tissue. Be sure that the lower surface does not come into contact with the lens tissue. Using the glass rod, or drcpoer, dispense a small drop of the mounting media onto the center of the slide. Replace the rod or dropper into the solution bottle and cover it. Using the soatuta, spread the solution into a triangular shape. While the fluid is spreading, cut a wedge of corresponding site from the filter. Place it upon the mounting media, sample side uo. Pick up the cover slip and place it on too of the filter. Press lightly on the cover slip to be sure the mounting media has made contact with it. Label the slide before completing any other slide. Sometime, after an hour or sc, the filter may not hava cleared. Usually, this ean be cured by pressing lightly on the cover slip with a pencil eraser thae has been wranoed with lens tissue. If the filter has been used to filter liquids or is damp, it will require drying, for it will not clear unless completely dry. Use only enough solution to clear ehe filter. If too much solution is used the sample may spread and give an erroneous count per unit area. The filter should be counted as soon as possible because ehe solution may tvencually form crystals ehae look like fibers and may be mistaken for part of Che sample. DUP 1200019 imniw i urtiw*w:--- f -7- After a little practice anti exoericnee, several samples may be mounted at the sane time with excellent results. Remember to Veen the area `n which mounting is done as clean as possible to prevent contamination of the filter. MICROSCOPE PRECAUTIONS AN3 MAINTENANCE Quality lens tissue is a must. The micrscopist should use it for any Vir.d of lens cleaning. It should be as l<nt free as possible. It may be wrapped around the blunt end of a small eamels hair brush and used to clean the eyenieces. Never wine the inside of the microscope body. If It is necessary to remove dirt from the inside of the tubes, blow it out with an asnirator bulb. Vhenever you are using imxerision oil, be sure that you wipe all surfaces that were in contact with the oil. Generally, solvents ehould not be used when cleaning lenses. Alcohol, li'<e most solvents will dissolve the lens mounting cement, which may ruin the lens 'system. Xylene should be used sparingly to remove immersion oil. Use a camels ha*r brush to clean first-surface mirrors and non-cr<t'cal lens surfaces. Never wipe first-surface mirrors with lens tissue. Avo<d touching a lens surface with fingers as the finger prints has a ten dency to etch into the lens surface. COUNTING ?PQCr3;TPg Place the samnle on the stage and focus on it. Since the limit is retained in the ton ten fifteen microns of the filter, be sure that you are focused in the orooer nlane. The reticle in the left eyeotece is used to define the counting area. The reticle should be calibrated prior to being used. The total fiber count (a fiber is anything three times as long as It is vide) should be at least 100 fibers, or twenty fields, whichever is less. Tt Is advisable to make as large a count as practical to get cn accurate average. If a fiber corssed the limits of the counting field, only those crossing either or both of two adjacent sides are counted. For example, s fiber erosing the toe or right, or possibly both sides would be counted. The sides chosen are at the discretion of the counter, but any counter must always us* the seme sides. The fibers counted sre estimated as to length, using the circles at the too of tha reticle. Our oractiee has been to record all fibers seen, all fibers longer than five microns and all fibers longer than 10 microns. However, for comoarisen with tha ACGIH TVJ Cl96S), only the longer than 5u fibers need be counted. DUP 1200020 - 8- FTr!.D O'SC**SST7'' Membrane fi'ters may be purchased Te-londed in plastic holders (Aeroso' Analyses Monitors). The '-'cnitors eons`t of three sections. The fi'tey t* he'd betveer the middle and bottom sections. Between the membrane fi'ter and the bottom sect*on lies a sun"ort old. The cci'hratcd ourno, designed to drew a known and constant sunplv of air, is alvays connected to the bottom of the field monitor case. When many loaded cases *r taken into one particular area for sampling, a blank or control filter (meaning a loaded fie'e monitor ease) should be taken out to the area, brought hack unused and counted. This will determine what degree of general contamination is oresent on the filters. We have found that handing the fteM monitor cases w<th cellulose bands greatly reduees the genera' contamination of the filters. The bands may bt purchased from Waiter H. Jelly and Cor.oany, Inc. They are white, ooaque, sire 41 x ?5 and come necked <n solution S-132. Unon removal from the solution, the bands are sHnoed around the middle and bottom joints, or around all joints, depending upon whether the sample is going to be drawn through the ton section nlu* hole, or the entire ton section removed for "onen" sampling. The latter procedure <$ recommended for asbestos dust sa-o'.inc since it results in a more even samnle distribution over the entire exnosed fiTter surface. Convenient nerson*! samoling oumns, such as thosa distributed by Mine Pafery Annlfanees Comnany, Willson Products Division or Union Industrial are excellent for short term, low rate (around 2 lam) samoling. A samni<ng numn is connected to a 3 foot length of non-co'laosabie. one quarter inch, rubber tubing vith a male T.eur slip adanter (stork number LH/L, available from Beeton, Dickson and Comnany) inserted into the other enc. This enables one to connect the hose direct'y to the case by sirn'y insert ing ehg adaoter into the plug holt at the bottom of the case. Field monitor eases may easily be re-used. The plugs and all sections are separated and placed in warm detergent water. The parts should be scrubbed thoroughly and rinsed in tap water. However, if the filters art to receive any chemical analysis, tha eases should also be rinsed in distilled water. The cases should be allowed to dry in a clean area (a clean room is preferable), to reduce contamination. The clean area if equally important when loading the filters into the eases. The filter sac (the thicker, fibrous disc) is placed in the bottom section. The filter is nlaced directly on the nad. The middle and ten sections arc added, the ease is pressed tightly together, and the ton nlug is inserted. Se-lacersr.r of the bottom plug is not necessary. A eellulose band is then place around the case and after the band drias, tha unit is ready for sampling. Sample eode numbers, etc. aav be written on the band or upon the filter ease, first making sure the markings can be removed when and if it It necessary. Additional information concerning filters and field monitors mav be obtained from Mi 11inore Cornoration. DUP 1200021 9 CA^rviArmN' p~ When a sample is taken, pertinent ir.femitJon about the sample shou'd be recorded at the sampling site, first, the samole number should be fritter, on the fie'd nor/tor ease and the s.mole ticket. Next, eneer a descrlotion of his operation in the sooronriate space. If the sample is a general a-.r samole and does net certain to any oarticular enoloyee, write ''general air samole" in the employee's r.ane soace. Information about the area may be vrritten in the "description of oneration" soace. If you have several nur:s which are identical in aooearance, but have different flew rates, it would he a good idea to assign then instrument numbers. This enables you to keen accurate records of maintenance and calibration. When instrument numbers are keot it is not necessary to enter the flow rate at the saraoling s'te. Tt may he entered later from the record cards. Otherwise, enter the flow rate at the sampling site. When a number of filters are taken into a general area a control (or blank) is taken along. This should be assigned a number and entered <n the blank number soace. Do not assign blank fil ters dunlicate numbers. When the sampling num.o is turned on, enter the tine <n the "time on" soace. While the sample is being taken make notes of controls, i.e. exhaust hoccs, fans, window ventilation, etc. These notes should be entered, in the "description of controls". The samole should then sign his name or initials at the bottom of the sheet. After sufficient time has passed, the samr'ir.g instrument should be turned off and the time recorded <n the "time off" soace. The differer.ee between "time on" and "time off" should be expressed in minutes ar.e should be en tered in the "total ti-e" soace. The "total air voi'jme" may be found by multio1 y'ng the flow rate (expressed liters oer minute) by the total time and recorded in the aoorooriate snaee. After the samole has been taken, brought back into the lab and mounted, the counting procedure is next. The microseooc must be oroserly set uo. ?lact the slide to be counted er. the mechanical stage, focus on the sample a short distanea away from the edge. Never count dose to the edres of the filter because the filter will oread a little and lower the count. Now, enter the date, samole number, blank number and field area on the count sheet. The counter should initial tha form, ip the "initial" soace. The sized fibers are entered from right to left across tha form, first entering the >lCu fibers, then ehe >5u fibe-s and finally, ell fibers seen, celled the total. Aftar 100 fibers or 20 fields ere counted and recorded, ell of the vereieel columns ere added uo and the totals are entered under their corresponding columns. Divide the totals at the bottom by the number of fields counted to determine the average number of fibers oer size range oer field. 3y using Information on these two sheets the eoneentrstion in fibers per cub{c milliliter may be ealeu'steh end entered in the "ec::." space on the count sheet. DUP 1200022 10 Concentration (Av. Fiber Cnt.) (filter area) (field area) (Samole volume) (1000) Av. Fiber Count: Filter area: Counting area: fanrnle volume: 1000: Average fiber count ner size range 855 mm2 for 37 cn dia. membrane filters Reticle calibrated in total time x flow rate, exoress in liters Converts liter to milliliters Tf blanks are used, subtract the average blank cout of the same sire range *rnra the average f-'ber count. DUP 1200023 - 11 ADDRESSES Millioore Field Monitor Cases Cat. No. MAW? 037AO Millioore filter Pads) Cat. No. AAW?03700 Millioore Filter Corporation Bedford, Massachusetts 07130 (complete) Portan Reticle Cat. No. 30084 Patterson Globe & Circle Reticle Cat. No. 300S3 Edmund Scientific Co. 701 Edscoro Building Barrington, New Jersey 08007 Wheaton Balsam Bottle Cat. No. 2244 Arthur H. Thomas Comoany Post Office Box 779 Philadelohia, Pennsylvania 19105 \ Adasters, hose end for 1/4" tubing to male leur slip Cat. No. LH/L Beeton, Dickinson end Company Rutherford, New Jersey White, ooaque, cellulose bands, 41 x 25 No. 28 Walter H. Jelly & Co., Inc. 2822 Birch Sereet Franklin Park, Illinois 60131 Personal .'ampler Mk. IT Willson Products Division Reading, Pennsylvania Monitaire Sampler Mine Safeey Appliances Co. Pittsburgh, Pennsylvania Unico Telematic Model C-110 Onico Environmental Industries, Ine. Fall River, Massachusetts DUP 1200024 DUP 1200025 SAMPLE TICKET COUNT SHEET