Document kmYr9gO9oZYyweLV4E96Jgp4B

FROM (NAME & LOCATION f D. G. Glasgow-EASC-Dayton-1250 DATE SUBJECT ; September 5, 1979 PCB CONTENT OF OIL SAMPLES .cc; D. J. Dahm/File F. N. Hodgson D. Q. Douglas REFERENCE MRC JOB NO. 409.3380 TO : James Finch Akron - 1010 The samples of oil which you submitted recently for determination of PCB content was analyzed under the conditions given below. The following PCB concentrations were found (reported as Aroclor 1254). Sample Designation PCB Level,ppm Therminol 55 No. 1 Therminol 55 No. 2 Therminol 55 No. 3 Therminol 55 No. 4 Therminol 55 No. 5 Therminol 55 No. 6 21,100 19.500 20,000 20.500 20,500 19,000 The oils were diluted with hexane and analyzed by electron capture gas chromatograph under the following conditions: GC Model: Column: , Column Temperature: Injection Port Temp: Detector Temperature: Carrier Gass PCB Screened for: Varian 3700, Model 8000 10' x 2mm glass packed with 3% OV101 on Supelcoport 210C " 250 C 350C CH4/Ar (10/90) at 60 psig on column Aroclor 1242, 1254, and 1260 The PCB present was identified by comparing the sample chromatogram to those of Aroclor 1242, 1254, and 1260 to establish which of these three was the most likely PCB present. The PCB level was then cal culated using the corresponding calibration curve. Also included is a copy of our report on the accuracy and precision of PCB analyses in oil matrices. Please contact me at ext. 328 if you have any questions. DGG/bap Enclosure D. Gerald Glasgow EASC Project Manager PCB-ARCH-EXT0376441