Material Safety Data Sheet
CertairiTeedH
CertainTeed Corporation P.O. Box 860 Valley Forge. PA 19482 (215) 341-7000 (24 Hour Telephone)
DATE PREPARED: September 14, 1990
PRODUCT IDENTIFICATION:
FLUID-TITE* Asbestos Cement Pipe and Fittings
Chemical Name: CAS No.: Common Name (s):
Asbestos Cement Pipe None A/C Pipe and Fittings
NFPA Rating: HMIS Rating:
Health
Fire
Reactivity
00
0
1* 0
0
(See Section 8 for acronyms/definitions.)
Degree of Hazard 0 - Minimal (Insignificant) 1 - Slight 2 - Moderate 3 - Serious (High) 4 - Severe (Extreme) `Chronic Health Effect(s)--See section 5.
1. INGREDIENT INFORMATION:
Chemical Name:
Asbestos (Chrysotile and Croddolite)
CAS No.:
1332-21-4 (12001-29-5 and 12001-28^1)
Common Name:
Exposure Limits:
OSHA
ACGIH TLV
Other
8 hr. PEL - 0.2 fibers
Chrysotile - 2 fibers
None
> 5 um/cc
> 5 um/cc
30 min. EL - 1 fiber
Croddolite - 0.2 fibers
> 5 um/cc
> 5 um/cc
in,This chemical is listed on EPA, SARA, Title' Section 313 but not Section 302, and is listed on California's
Proposition 65. 1
Chemical Name: CAS No.: Common Name: Exposure Limits:
Quartz 14808-60-7 Crystalline Silica OSHA PEL Respirable Dust: 0.1 mg/m3
ACGIH TLV Respirable Dust 0.1 mg/mJ
Other None
This chemical is not listed on EPA, SARA, Title III, Section 302 or 313, but Crystalline Silica is listed on California's Proposition 65, with a qualifier for airborne partides of respirable size.
2. PHYSICAL DATA
Boiling Point (F): None Melting Point (F): None Odor None Colon Cement Gray Vapor Density (Air=l): N/A
Specific Gravity (H20=I): 2.35 Evaporative Rate (ethyl ether=l): N/A Vapor Pressure (mmHg @ 20C): N/A % Volatile by Volume: N/A % Solubility: Negligible
Appearance: Cement gray-colored pipe and fittings
Page 1 of 4
01-08-0020 9/90
CTD030191
3. FIRE AND EXPLOSION HAZARD DATA
Flash Poinl (F) and Method: Does not support combustion.Flammable Limits:
LEL' N/A
UEL: N/A
Autoignition Temperature: Does not support combustion.
Extinguishing Media: Use that which is applicable to surrounding fire. This material is non-combustible.
Special Fire Fighting Procedures: None
Unusual Fire and Explosion Hazard: None
4. PHYSICAL HAZARDS
Corrosivity: None Reactivity: None Reactivity with water: None
5. HEALTH HAZARD DATA
Health effects from storing and handling asbestos cement pipe and fittings should not be a problem if industry recommended work practices are used. (See section 7 for information on industry work practices.) Failure to follow these practices may result in the airborne release of the entrapped asbestos fibers and silica dust ingredients. Exposure to the ingredient dust and fiber may cause the following health effects:
Primary Routes of Entry: Inhalation, skin and eye contact
Acute Effects:
Inhalation: Dust from cutting/grinding may cause irritation and coughing.
Skin contact: Dusts may cause irritation and itching. Eye contact: Dust may cause redness and irritation.
Chronic Effects:
Inhalation: Excessive exposure to silica and asbestos dust causes a disabling scarring of the lungs, or pneumonoconiosis, called "silicosis" and "asbestosis," which gradually reduce lung capacity and efficiency. Symptoms, which appear 15-20 years after the first exposure include coughing, decreased vital capacity, basal rales, cyanosis, cor pulmonale, clubbing of the fingers, anorexia, weakness and weight loss. Radiologic studies may show diffuse increase in lung opacities and pleural calcifications.
Asbestos is classified as a human carcinogen by the 1ARC and NTP and is regulated by OSHA as a human carcinogen. Asbestos-exposed workers show an increased incidence of pleural or peritoneal mesothelioma and high rates of respiratory cancer. The incidence of pulmonary fibrosis and lung cancer in asbestos-exposed workers is greatly increased by smoking. Reports associating cancer to other body organs exist, although the evidence is not clear.
Skin Contact: Prolonged exposure to asbestos may cause asbestos warts and dermatitis, usually confined to the hands and forearm.
Eye Contact: Prolonged exposure to asbestos may cause conjunctivitis.
Page 2 of 4
CTD030192
Medical Conditions Which May be Aggravated: In groups of workers exposed to asbestos, 97.5% of asbestos-related lung cancers occur with those who also smoke cigarettes.
Carcinogenicity:
Ingredient: Asbestos NTP: Human [ARC: Gassified as Group 1, Carcinogenic to Humans OSHA: Regulated in 29CFR1910.1001
Ingredient: Silica, Crystalline NTP: Not Listed LARC: Classified as Group 2A, Probably Carcinogenic to Humans OSHA: Not Regulated as a Carcinogen
6. EMERGENCY AND FIRST AID PROCEDURES
Inhalation: Upper respiratory - remove from exposure. Get medical help if irritation persists. Skin Contact* Geanse with soap and water. Get medical help if irritation persists. Eye Contact: Flush well with running water for at least 15 minutes. Get medical help if irritation persists. Ingestion: Unlikely. Consult physician if unusual reaction is noted. Spills: Pipe fragments and installation debris must be handled in a manner which avoids airborne dispersion of asbestos or silica dusk Use wet or vacuum method with HEPA filter for cleanup. Avoid inhalation of dusts. Fires: Does not support combustion. Explosion: N/A Accidental or Unplanned Releases: Avoid generation of dust from cutting or grinding.
7. SPECIAL PROTECTION INFORMATION
Personal Protective Equipment:
Respiratory: OSHA requires the establishment of a respirator program using NIOSH and MSHA approved respirators in emergencies and in work situations where feasible engineering and work practice controls are not yet sufficient to reduce exposure to or below the PEL
The airborne concentration of asbestos dictates the appropriate respirators to be used:
Not in excess of 2 f/cc (10 * PEL) - Half-mask air-purifying respirator equipped with high-efficiency filters;
Not in excess of 10 f/cc (50 * PEL) - Full facepiece air-purifying respirator equipped with high-efficiency filters;
Not in excess of 20 f/cc (100 * PEL) - Any powered air-purifying respirator equipped with high-efficiency
filters, or any supplied-air respirator operated in continuous flow mode;
,
Not in excess of 200 f/cc (1000 x PEL) - Full facepiece supplied-air respirator operated in pressure demand mode;
Greater than 200 f/cc ( > 1000 x PEL) or unknown concentration - Full facepiece supplied-air respirator operated in pressure demand mode equipped with an auxiliary positive pressure self-contained breathing apparatus.
Page 3 of 4
CTD030193
Eye Protection: Wear eye protection (safety glasses or goggles) to prevent dust in eyes.
Special Clothing: When airborne exposures exceed the PEL, coveralls or similar full-body clothing, head and fool coverings and gloves must be worn.
Work Practices and Engineering Controls: Always use industry recommended work practices when handling or performing field operations with asbestos cement pipe. See Manufacturers' Installation Manual, American Waterworks Association Manual M-16, or Asbestos Cement Pipe Producers Association Publications for detailed information on industry recommended work practices.
See also the Occupational Safety and Health Administration Regulation 29CFR1910.1001 which regulates workplace exposure to asbestos dust and any state or local workplace codes regulating asbestos exposure.
Avoid generation of dusts, do not cut or bevel asbestos cement pipe or fittings with abrasive disc saws or abrasive disc sanders.
Storage: None
Waste Disposal Information: OSHA requires warning labels stating "DANGER, CONTAINS ASBESTOS FIBERS, AVOID CREATING DUST, CANCER AND LUNG DISEASE HAZARD" be affixed to all raw materials, mixtures, scrap, waste, debris and other products containing asbestos or their containers. Dispose of waste in accordance with federal, state and local regulations.
8. ADDITIONAL COMMENTS
Acronyms used in this MSDS:
A/C: ACGIH: CAS No.: EPA:
Asbestos/Cement American Conference of Governmental Industrial Hygienists Chemical Abstracts Service Number Environmental Protection Agency (USA)
f/cc:
Fibers per cubic centimeter
EL: Excursion limit Fibers > 5um/cc Fibeis greater than 5 microns in length per cubic centimeter of air
HEPA:
High Efficiency Particulate Air
HMIS:
Hazardous Materials Identification System
1ARC: LEL:
International Agency for Research on Cancer Lower Explosive Limit
mg/m3: mppcf:
Milligrams per cubic meter Millions of particles per cubic foot
MSHA:
Mine Safety and Health Administration
N/A:
Not applicable
NFPA: NIOSH:
National Fire Protection Association National Institute for Occupational Safety and Health
NTP:
National Toxicology Program
OSHA:
Occupational Safety and Health Administration
PEL:
Permissible Exposure Limit
SARA: Title III:
Superfund Amendments and Reauthorization Act Emergency Planning and Community Right to Know Act
Section 302: Extremely Hazardous Substances
Section 313: Toxic Chemicals
TLV:
Threshold Limit Values
UEL:
Upper Explosive Limit
Page 4 of 4
CTD030194