Air Conditioning Chicago Steel Furnace Co. 9326 S. Anthony Ave., Chicago 17, 111. Manufacturers and Designers Artcraft Heating & Air Conditioning Equipment ired DIRECT-FIRED SPACE HEATERS 350,000 Btu to 2,000,000 Btu UNIFORM AIR DELIVERY BLOWERS--Three standard up-blast discharge, multi-vane Blowers, each in dividually powered, are provided'to sup ply the correct amount of air to properly cool the Heat Exchanger. Individuallydriven Blowers are.used because of the great flexibility of operation obtainable. Uniform bonnet temperature may be enjoyed by the simple expediency of in creasing or reducing the amount of air driven around any particular section of the Heat Exchanger. Performance Data Direct Fired Model A Units MODEL OUTPUT BTU AIR DEL. CFM 350-A 500-A 750-A 1000-A 1250-A 1500-A 2000-A 350,000 3000-4200 500,000 000-7800 750,000 *`-'00-0600 1,000,000 12500-15500 1,250,000 15000-17500 1.500,000 17500-21000 2,000,000 21000-24000 L 72 92 100 114 124 128 144 W 40 42 50 54 56 62 66 H 84 90 99 no 114 115 125 ARTCRAFT SUSPENDED UNITS Fired with Gas or OH Ratings and Specifications Suspended Units MODEL 75-S 75-SL 100-S 150-S 200-S 250-S 350-S 400-S 500-S 750-8 OUTPUT AIR DEL. BTU CFM-*"S.P. 85.000 85.000 100,000 150,000 200,000 250,000 350.000 400.000 500.000 750,000 800-1000 800-1000 1000-1600 1200-2000 2200-2600 2400-3200 3000-4200 4200-5200 4600-6200 8200-9600 L 63 78 76 79 86 90 104 107 114 146 WH 24 34 22 22 24 34 31 36 31 40 35 42 40 54 42 54 45 62 52 66 1182 Factory Inctallation Model tOOS-t Air Conditioning Automatic Equipment; Direct-Fired Heaters, Unit Heaters Lee Corporation 1011 Tatnall Street, Wilmington, Delaware Baltchobe, Md. New-York, N. Y: ' Chicago, III. Manufacturers and Designers of Complete Line of Industrial and Commercial Warm Air Heaters Representatives in all Principal Cities Exclusive Representation to the Railroads: Railroad Supply and Equipment, Inc., First Federal Bldg.. Scranton 3, Pa. In Canada: Comstock Lee Heating Division, Canadian Comstock Company. 206 Laird Drive North. Leaside, Toronto, Canada Lee Heater Number Output Capacity (Btu per hr) Total Heating Surface in so ft Cu ft of Air per Min. (Approx.)* Fan Motor HP External Static Pressure (Std ) Maximum External Static Press Available for Duct Work (larger Motor Required) Temperature Rise (Degree F) Fuel Consumption** A-cu ft Gas per hr (App.) B-gal Oil per hr (Approx.) Shipping Weight (Approx.) Lbs Refractory Comb. Chamber Stainless Steel Comb. Chamber LEE HEAVY DUTY HEATERS LEE HEATERS have been in continuous operation since 1918. Lee Heater in stallations have been, made in most of the States of- the United States, in Canada, Alaska, Yukon . Territory, Northwest Territory, Labrador, Iceland, Norway, Mexico and South America. Firing Equipment manufactured spe cially for us by leading Companies with International service organization. There is a Service man near you if and when you require assistance. In addi tion Lee maintains a competent field serving staff. Replacement and Spare Parts Service is maintained. Most items are carried in stock. 300 300,000 92 3500 Y l- 400 400,000 106 4500 i Y 500 500,000 126 6000 2 Y Y 600 600,000 202 7000 3 jY 750 750,000 235 8500 5 r V 79 380 2.6 3000 2100 82* 500 3.5 3100 2200 77 630 . 4.3 3300 2400 79 750 5.2 4500 4000 82 940 6.5 4700 4200 Leo Heater Number Uutput Capacity (Btu per hr) lotal Heating Surface in sq ft Cu ft of Air per min. (Approx.)* -ban Motor hp External Static Pressure (Std.) Maximum External Static Press. Available for Duct Work _ (Larger Motor Required) Temperature Rise (Degree F) Fuel Consumption** A-cu ft Gas per hr. (Add.) B-gal Oil per hr. (Approx.) Shipping Weight (Approx.) Lbs Refractory Comb. Chamber Stainless Steel Comb. Chamber 1,000 1,000,000 278 11,500 5 Y Y 1250 1,250,000 333 14,000 7* Y Y 1500 1,500,000 375 17,000 10 Y Y 1750 1,750,000 423 20,000 15 1' 2000 2,000,000 470 22.000 15 j* r 80 1250 8.6 6000 5200 83 1560 10.8 6300 5500 82 1880 . 13.0 . 7500 6200 81* 2190 15.0 8600 7400 84* 2500 17.2 9800 8600 *Bssed on Standard Air at 70 F Free Delivery. Fuel Consumption Based on 1000 Btu per cu It Cas, 145,000 Btu per Gal Oil, and on 80 per cent Effi ciency for the heater. 1183